Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.1 LAccepted-AOC | ₹24.1 L Quoted ₹25.4 L | L1 | Accepted-AOC Lowest one |
| 2 | L2₹28.3 L+₹2.8 L (11.2%)Rejected-Finance | ₹28.3 L+₹2.8 L (11.2%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹29.7 L+₹4.3 L (16.9%)Rejected-Finance E 84 OF HQ CWE NW MUMBAI AGE 87 1 3 GEETA NAGAR NAVY NAGAR COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | ₹29.7 L+₹4.3 L (16.9%) | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹32.0 L+₹6.5 L (25.7%)Rejected-Finance | ₹32.0 L+₹6.5 L (25.7%) | L4 | Rejected-Finance Other than lowest |
| 5 | L5₹39.8 L+₹14.4 L (56.5%)Rejected-Finance NOT AVAILABLE | ₹39.8 L+₹14.4 L (56.5%) | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
21 Aug 2021, 6:00 pmClosed
GE NW NOFRA
Dr Homi Bhabha Road, Navy Nagar Colaba, Mumbai-05
REPAIR AND MAINTENANCE OF CEILING FAN EXHAUST FANS INCLUING ELECTRIC WIRING WITH MCBS AT NOFRA UNDER GE NW NOFRA, COLABA, MUMBAI.
2021_MES_465619_1
8954
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Mumbai
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE NW NOFRA
₹80,000
Yes
21 Jan 2022
5 Aug 2021
25 Aug 2021
5 Aug 2021
21 Aug 2021
9 Aug 2021
5 Aug 2021 - 7 Aug 2021
Amount
Material & labour for unscrewing body parts of fans of any make/brands and description and opening of the stator & rotor of following sizes of fans and taking out down rod canopy, shackle, condenser housing with rubber reel bushes, ball bearing, metal bush and carry out repairs as directed and as required as under:- (a). M&L for opening the stator & rotor of the 1200mm / 1400 mm sweep ceiling fan cutting the exsisting worn winding & rewinding the fan with superior quality rewinding wire & filling the varnish as insulation between each winds & covering each loops of winding by sleeves & paper & reassembling of complete fan by fixing servicable old and new parts of fans i.e. rubber bush of condensor & shackle housing , condensor, gun metal bushes, ball bearings twin twisted copper cable down rod assembly with its shackle condenser housing & canopy ,split pins complete all as per manufacturers design air delivery including greasing,oiling & testing of fans all as per manufacturers design & speed, complete all as directed by Engineer in charge & approved for 1200mm/1400mm sweep.
Notes:- (i). The quoted unit rate shall be deemed to be inclusive of taking out defective parts and fixing of new parts. All new parts shall be measured and paid vide relevant items of the schedule. (ii). The rates for refixing & taking out servicable parts shall be deemed to be included in quoted unit rates. (iii). New parts shall be of respective makes of fans. (iv). The quoted unit rates shall also include writing of MES No of fans. (v). Unservicable / defective retrived parts shall be credited vide sch of creidt. (vi). After assembling all fans shall be tested for the speed as directed. (vii). All the fans are laying in store yard of AGE E/M and shall be repaired at store yard only.
All as per srl item No 1 here-in-before but for wall mounting fans/air circulation fans of any size
All as per srl item No 1 here-in-before but for Exhaust fans of 225/250mm/ 300 mm sweep
All as per srl item No 1 here-in-before but for Exhaust fans of 450 mm sweep
Supply & Fix in repair elctronic Fan regulator 400 watt step type heavy duty complete all as specified and directed by Engineer in charge. Make: Havells,CG,Indo Asian
supply and fix in repair GI U clamp heavy duty rubber reel of superior quality and nut and bolts with locking arrangement complete all as specified and directed by Engineer in charge.
Supply only PVC canopy cover superior quality complete all as specified and directed by Engineer in charge.
M&L for cleaning the fan motor assembly body, blade of ceiling fan, filling the cavity & painting with existing colour the ceiling fan / Exhaust fan with one coat of superior quality synthetic enamel paint by spraying appratus and spraying process including writing the MES number on the ceiling fans of 1200mm /1400 mm sweep with black colour synthetic enamel paint complete all as specified and directed by Engineer in charge.
All as per srl item No 8 here-in-before but for wall mounting fan / air circulator of any size complete all as specified and directed by Engineer in charge.
All as per srl item No 8 here-in-before but for Exhaust fans of 225mm / 250mm / 300 mm sweep complete all as specified and directed by Engineer in charge.
Supply only bearing No 6201 for 1200/1400mm sweep ceiling fans complete all as specified and directed by Engineer in charge. Make : NBC or SKF or equivalent as approved by GE.
Supply only bearing No 6202 for 1200/1400mm sweep ceiling fans complete all as specified and directed by Engineer in charge. Make : NBC or SKF or equivalent as approved by GE.
Supply only capacitor 2.5 MFD dry type complete all as specified and directed by Engineer in charge.
Supply only capacitor 4.00 MFD dry type complete all as specified and directed by Engineer in charge.
Supply only gun metal bush suitable for 1200 / 1400mm sweep ceiling fan complete all as specified and directed by Engineer in charge.
S&F Clamp nut , bolt incliding safety pin for ceiling fan including taking down old pin complete all as specified and directed by Engineer in charge.
Taking down old unserviceable rusted extaust fan shutter and supply and fixing shutter of size 255 to 450 mm sweep complete all as specified and directed by Engineer in charge.
Making round/ squar hole cutting in the kitchen wall with the help of cutting machine / chisel / hammer etc for fixing of exhaust fan of size 225 mm to 300 mm & making good to the distrubed surface including plaster, distumper , white wash complete all as specified and directed by Engineer in charge.
Checking serviceability of all ceiling fans/ exhaust fan in each quarter and checking clamps nut, bolts, pins are in helthy condition If any problem in any items will be note down by electrician and informed concerned JE E/M and rectify the problem next day. NOTE : All items will be paid separetly and as directed by Engr -in-charge
Taking down carefully aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators sockets etc to be measured separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed by Engineer in charge.
Material and Labour for point wiring complete with 1.5 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors 1100 volts grade drawn through and including PVC pipe of size not less than 20 / 25 mm dia including PVC bend, tee joints etc as per site requirement , ISI marked with accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI marked terminal boxes/ modular boxes surfacing on wall including one FRLS PVC insulated & sheathed multistranded green colour copper conductor 1.5 sqmm as earth continuity conductor connected to common earth as earth dolly for :-
(a) One ceiling fan point controlled with one 5A switch complete all as specified and directed by Engineer in charge.
(b) One exhaust fan point controlled with one 5A switch complete all as specified and directed by Engineer in charge.
Supply and fix Modular Switch, 6Amp, One way, 1 module complete all as specified and directed by Engineer in charge. Make : Legrand (Arteor) / Havells (Coral) / Gold Medal Electrical Pvt Ltd (NIXON).
Supply and fix support function blank plate single, 1 module complete all as specified and directed by Engineer in charge.
Supply and fix Modular type, electronic fan regulator (5 step), 450 Watts, 230 volts, 2 module complete all as specified and directed by Engineer in charge. Make : Legrand (Arteor) / Havells (Coral) / Gold Medal Electrical Pvt Ltd (NIXON).
Supply and fix ceiling rose surface bakelite with ISI mark , flush type with ISI mark three terminals complete all as specified and directed by Engineer in charge.
Supply and fix Modular metal flush box 1/2 module including cutting and chassing complete all as specified and directed by Engineer in charge. Make : Legrand (Arteor) / Havells (Coral) / Gold Medal Electrical Pvt Ltd (WEGA)
Supply and fix sheet metal enclosure 12 way Double door type having protection IP-42, with 200 Amps rated bus bar connecting with existing wiring circuits by providing copper pin terminals of suitable size complete all as directed by Engineer in charge & comprising of the following :- Make: ABB , Strandard , Legrand
Supply and fix sheet metal enclosure 8 way Double door type having protection IP-42, with 200 Amps rated bus bar connecting with existing wiring circuits by providing copper pin terminals of suitable size complete all as specified and directed by Engineer in charge. Make: ABB, Strandred/ Legrand
MCB SPN 63 Amps, 240 Volts - 01 No Make - Legrand , Siemens , Standard , Havells
MCB SP 6-32 Amps, 240 Volts - 01 No Make - Legrand , Siemens , Standard , Havells
Angrahit Services Trading Co
shree arihant constrution
DHARMESH ENTERPRISES
SHREE JAGDISH FURNITURE CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .