Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.6 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹36.9 L+₹1,756 (0.05%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹37.9 L+₹1.1 L (2.86%)Rejected-Finance | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹39.1 L+₹2.3 L (6.18%)Rejected-Finance 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹39.2 L+₹2.4 L (6.44%)Rejected-Finance | L5 | Rejected-Finance Being other than lowest |
Tender Value
₹45.5 L
EMD Value
₹91,000
Closing Date
1 Aug 2023, 6:00 pmClosed
GE (EAST) Delhi Cantt-10
GE (EAST) Delhi Cantt-10
REPAIRS /REPLACEMENT OF ELECTRIC WIRING, LIGHT FITTINGS AND CONNECTED E/M ITEMS AT MANEKSHAW MARG, URBAN VILLAGE, CASSEL ROAD AND CHURCH ROAD UNDER GE (EAST) DELHI CANTT-10
2023_MES_607152_1
GE/DE-46/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Delhi Cantt-10
Class D Cat b(i)
8 documents required · 8 mandatory
₹500
GE (EAST) Delhi Cantt-10
₹91,000
Yes
30 Sept 2023
30 Jun 2023
3 Aug 2023
30 Jun 2023
1 Aug 2023
18 Jul 2023
Amount
Taking down/ out carefully copper/aluminium point wiring for light/fan/bell/ sockets 5/15 Amps complete without accessories as switches,Sockets, holders,ceiling roses,light fitting regulators etc ( to be measured separately) and making good the disturbed surface all as directed.
M&L for point wiring with single core fire retardant low smoke PVC insulated, unsheathed multi stranded copper conductor of size 1.5 sqmm alongwith 1.5 sqmm earth wire of multi strand copper conductor (with same specification) connected to common earth dolly and drawing through existing surface/concealed conduit pipe and in existing MS box/modular box covered with existing hylem sheet / modular plate (top cover) for mounting switches, sockets or fan regulators etc for the following :-
(a) One light point/ fan point/ bell point controlled by one switch
(b) One socket outlet 5 Amps controlled by one switch on same board
(c) One socket outlet 5 amps controlled by one switch on independent board
(d) one light point controlled by two 2 way switches
All as per item No.2 here in before but wiring with 2.5sqmm copper wire and 2.5sqmm earth wire for socket out let on independent board.
S&F in repair switch piano flush type, 6 amps one way,SP,230 volts AC all as directed.
S&F in repair switch piano flush type, 6 amps two way,SP,230 volts AC all as directed.
S&F in repair switch piano flush type, 16 amps one way,SP,230 volts AC all as directed.
S&F in repair switch piano bell push flush type, 6 amps one way,SP,230 volts AC all as directed.
S&F in repair socket outlet 6 amps 5 pin , all as directed.
S&F in repair socket outlet 6&16 amps 6 pin all as directed.
S&F in repair piano type Step fan regulator, 120 watts single module all as directed.
S&F in repair modular switch flush type, 6 amps one way,SP,230 volts AC all as directed.
S&F in repair modular switch flush type, 6 amps two way,SP,230 volts AC all as directed.
S&F in repair modular switch flush type, 16 amps one way,SP,230 volts AC all as directed.
S&F in repair modular switch bell push flush type, 6 amps one way,SP,230 volts AC all as directed.
S&F in repair modular socket outlet 6 amps 5 pin 2 module all as directed.
S&F in repair modular socket outlet 6 & 16 amps 6 pin multipurpose combined 2 module all as directed.
S&F in repair modular Step Fan regulator, 120 watts single / double module all as directed.
S&F in repair Modular white cover plate with frame 1 module all as directed
S&F in repair Modular white cover plate with frame 2 module all as directed
S&F in repair Modular white cover plate with frame 3 module all as directed
S&F in repair Modular white cover plate with frame 4 module all as directed
S&F in repair Modular white cover plate with frame 6 module all as directed
S&F in repair Modular white cover plate with frame 12 module all as directed
S&F in repair Modular white cover plate with frame 18 module all as directed
S&F in repair Modular Metal Flush Box 1/2 module duly embedded in wall in cement mortar 1:4 after chase cutting/cutting of wall tile or marble with cutter and matching/making good the existing surface complete all as specified and as directed
S&F in repair Modular Metal Flush Box 3 module duly embedded in wall in cement mortar 1:4 after chase cutting/cutting of wall tile or marble with cutter and matching/making good the existing surface complete all as specified and as directed
S&F in repair Modular Metal Flush Box 4 module duly embedded in wall in cement mortar 1:4 after chase cutting/cutting of wall tile or marble with cutter and matching/making good the existing surface complete all as specified and as directed
S&F in repair Modular Metal Flush Box 6 module duly embedded in wall in cement mortar 1:4 after chase cutting/cutting of wall tile or marble with cutter and matching/making good the existing surface complete all as specified and as directed
S&F in repair Modular Metal Flush Box 12 module duly embedded in wall in cement mortar 1:4 after chase cutting/cutting of wall tile or marble with cutter and matching/making good the existing surface complete all as specified and as directed
S&F in repair Modular Metal Flush Box 18 module duly embedded in wall in cement mortar 1:4 after chase cutting/cutting of wall tile or marble with cutter and matching/making good the existing surface complete all as specified and as directed
Supply and fixing in replacement of lamp holder PVC/ Polycarbonate type insulated body with back plate suitable for batten fittings complete all as specifed and as directed.
Supply and fixing in replacement of Ceiling rose, insulated body, 3 terminal, 240 volts complete all as specified and as directed.
Supply and fixing in replacement of electric bell of DINGDONG type, 6 Amps, 240 volts, single pole and making all necessary connections complete all as directed.
Supply and fixing in replacement of wall light fitting comet type suitable for LED lamp complete all as directed.
Supply and fixing in replacement of LED bed side light, 5/6 Watts, wall mounted type and making all electric connections complete all as specified and directed.
S & F in replacement LED energy efficient integrated battens fittings, PVC extruded heat sink with shatter proof opal shell of polycarbonate compound, 20 Watts, cool/warm white as per site requirement complete all as specified and directed..
S & F in replacement of LED energy efficient integrated battens fittings, PVC extruded heat sink with shatter proof opal shell of polycarbonate compound, 10 Watts, cool/warm white as per site requirement complete all as specified and directed..
S&F in replacement of bulk head fitting 6.5 W with PMMA diffuser complete all as specified and directed.
Supply and fixing in replacement of LED ceiling light fitting 15 watt, in round shape, surface/recess type cool/warm white with inbuilt driver as per site requirement and making all electric connections complete all as directed.
Supply and fixing in replacement of LED ceiling light fitting 10 watt, in round shape, surface/recess type cool/warm white with inbuilt driver as per site requirement and making all electric connections complete all as directed.
S & F in replacement of energy efficient LED fittings 45W LED suitable for building security light pressure die cast aluminium roadway luminaire with high power LEDs and HF electronic driver complete all as directed.
Supply and fixing in replacement of street light fitting bracket, 1.0 mtr long made out of galvanized iron pipe of 25 mm dia size light grade complete with nut, bolts, washer, clamps etc inclusive of one primer coat, one under coat and one finishing coat of silver paint complete all as directed.
Material and labour for replacement of submain wiring complete with 2 x 4.0 sqmm (nominal area) FRLS, PVC insulated, unsheathed and multistranded copper conductor cable ISI marked, and 1 x 4 sqmm( same specification ) as earth wire in existing PVC conduit complete all as directed.
Material and labour for replacement of submain wiring complete with 2 x 10.0 sqmm (nominal area) FRLS, PVC insulated, unsheathed and multistranded copper conductor cable ISI marked, and 1 x 10 sqmm( same specification ) as earth wire in existing PVC conduit complete all as directed.
Material and labour for replacement of submain wiring complete with 2 x 16.0 sqmm (nominal area) FRLS, PVC insulated, unsheathed and multistranded copper conductor cable ISI marked, and 1 x 16 sqmm( same specification ) as earth wire in existing PVC conduit complete all as directed.
Supply and fixing in replacement of MCB C Curve type, 10 kA, 10 to 32 Amp, Single Pole with over load and short circuit protection complete all as directed.
Supply and fixing in replacement Isolator SPN 32/40 A including connections complete all as specified.
Supply and fixing in replacement Isolator SPN 63 A including connections complete all as specified.
Supply and fixing in replacement Isolator TPN 40 A including connections complete all as specified.
Supply and fixing in replacement Isolator TPN 63 A including connections complete all as specified.
Supply and fixing in replacement of Modular AC 25 Amps SP mini MCB, 230 Volts, 50Hz for module sheet complete all as specified and as directed.
S&F of MCB DB confirming to IP 43 - IK 09 with double door, SPN 16 way, double door complete with din rail, Neutral and Earthing bar after taking out the old unserviceable DBs, connection complete and making good the disturbed surfaces.
S&F of MCB DB confirming to IP 43 - IK 09 with double door, SPN 08 way, double door complete with din rail, Neutral and Earthing bar after taking out the old unserviceable DBs, connection complete and making good the disturbed surfaces.
S&F of MCB DB confirming to IP 43 - IK 09 with single door, SPN 04 way, double door complete with din rail, Neutral and Earthing bar after taking out the old unserviceable DBs, connection complete and making good the disturbed surfaces.
Supply and fixing in replacement of MCCB incommer Distribution Board ( Vertical Load line DB) double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, VTPN 04 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCCB as incommer and MCB as outgoing and making all necessary connections and taking out the old unserviceable DB complete all as directed.
S&F in replacement of TPN DB 04 way double door confirming to IP43 & IK 09 protection complete with din rail, Neutral and Earthing bar after taking out the old unserviceable DBs, connection complete and making good the disturbed surfaces.
S & F in replacement of MCCB, 415 volts, three pole of cap 100/125 Amps, 10 KA, ICS = 100% ICU, with Thermal - Magnetic Release, including necessary spreader / thimbles of suitable size and making connections complete all as directed. Make : C&S/Havells/Legrand/Siemens/L&T
Supply and fixing of PVC casing & caping ( ISI marked) 20 mm width double lock type inclusive of all fittings such as tees, bends, elbow, etc and all fixing accessories complete all as directed.
Supply and fixing of PVC casing & caping ( ISI marked) 25 mm width double lock type inclusive of all fittings such as tees, bends, elbow, etc and all fixing accessories complete all as directed.
S&F in replacement of rigid non metallic PVC conduit 20 mm dia inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook etc complete for surface mounted / concealed including cutting chases in wall and making good the surface all as specified and and as directed.
S&F in replacement of rigid non metallic PVC conduit 25 mm dia inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook etc complete for surface mounted / concealed including cutting chases in wall and making good the surface all as specified and and as directed.
Supply and fixing in replacement of Ventilating fan 250 mm sweep plastic body type including self cosing louver and making all electric connections complete all as directed.
Supply and fixing in replacement of Ventilating fan 200 mm sweep plastic body type including self cosing louver and making all electric connections complete all as directed.
Supply and fixing in replacement of Wall Mounted Fan 400 mm sweep plastic body type including making all electric connections and depositing the old u/s to MES store yard complete all as directed.
S&F in replacement of ceiling fan (BLDC)1200mm sweep, 5 Star rating, regulator operated, service value not less than 6.0, 240 Volts. 50 Hz complete all as specified and directed and depositing the old unserviceable to MES store yard.
Supply and fixing exhaust fan upto 300 mm sweep metalic body type and making all electric connections complete all as directed and depositing the old U/s item to MES store yard.
M&L for rewinding of exhaust fan(300mm)/wall mounting fan(400mm) with super enamelled copper wire of required size duly varnishing including greasing/oiling and commissioning/testing to the entire satisfaction of Engineer-in-charge.
M&L for rewinding of Ceiling fan 1200/1400mm sweep with super enamelled copper wire of required size duly varnishing including greasing/oiling and commissioning/testing to the entire satisfaction of Engineer-in-charge.
S & F in replacement plastic body capacitor of capacity 2.5 mfd with wire suitable for single phase motor and making connection complete all as specified and directed
S & F in replacement plastic body capacitor of capacity 3.15 mfd with wire suitable for single phase motor and making connection complete all as specified and directed
S&F in replacement of ball bearing No 6201/6202 suitable for ceiling fan complete all as specified and directed.
M & L for ceiling fan down rod fabricated out of MS pipe medium grade 15 mm dia cut to length as per site requirement duly painted white with synthetic enamel paint over a coat of red oxide primer having through hole and cut of suitable size at both end for fixing ceiling fan and clamp etc complete all as specified and as directed
S&F MS clamp with rubber real including nut, bolt and split suitable for ceiling fan to hook complete all as specified and as directed.
S&F PVC Gang Box suitable for one No 5 Amps Switch and one No 5 Amps Socket complete all as specified and as directed. Make : Presto plast/Pressfit/Polyplast.
S&F PVC Gang Box suitable for two No 5 Amps Switch and two No 5 Amps Socket complete all as specified and as directed. Make : Presto plast/Pressfit/Polyplast.
S&F PVC Gang Box suitable for one No 15 Amps Switch and one No 15 Amps Socket complete all as specified and as directed. Make : Presto plast/Pressfit/Polyplast.
S & F in replacement of plug top 3 pin 10/20 amp earth metal clad suitable for industrial type DB complete all as directed.
S & F in replacement of socket 3 pin 10/20 amp earth metal clad suitable for industrial type DB complete all as directed.
Supply and fixing in replacement of 'T' cover Bakelite sheet 2 mm thick in round shape complete all as specified.
Supply and fixing in replacement of Bakelite sheet 3mm thick of size 5"x5" duly wire cut for switches, sockets, regulator etc as per site requirement as directed.
S&F in replacement of Bakelite sheet 3mm thick of size 8"x5" duly wire cut for switches, sockets, regulator etc as per site requirement as directed.
S&F in replacement of Bakelite sheet 3mm thick of size 8"x10"duly wire cut for switches, sockets, regulator etc as per site requirement all as directed.
S&F in replacement of Bakelite sheet 3mm thick of size 10"x12" duly wire cut for switches, sockets, regulator etc as per site requirement all as directed.
Taking down old unserviceable LT U/G cable any size and core complete all as specified.
S&F XLPE insulated armoured heavy duty U/G aluminium conductor cable served with an inner sheathing of PVC tape armoured with galvanised steel strip wire or tape and overall PVC sheathed of size 10 Sqmm 2 core. Make:Polycab/Gloster/Havells/Plaza/Finolex.
All as per item sl No 85 but 25 sqmm, 4 core.
All as per item sl No 85 but 50 sqmm, 3 1/2 core.
Excavation in trenches in soft / loose soil not exceeding 1.5 meter depth and not exceeding 1.5 meter wide and getting out including trimming of sides complete all as directed.
Material and labour for brick protection to cable using old size class 'B' bricks, laid flat, dry butt jointed, laid lengthwise perpendicular to the axis of cable complete all as directed.
Material and labour for sand cushioning with a layer of fine sand 8 cm thick before laying the cable and 15 cm after laying the cable in trenches to cover under ground cable complete all as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as directed.
Removal of excavated material n exc 50m and depositing n exc 1.5m above starting point complete all as specified and as directed..
S&F in replacement of Galvanised Steel tubing light grade of size 50mm bore under floor/road etc complete all as specified and as directed.
Supply and fixing in replacement of Geyser 25 ltre capacity vertical type with steel tank and glass inner linen , 5 star rating, minimum 8 bar withstanding pressure complete including taking down the old u/s geyser and depositing to MES store yard complete all as specifed and directed.
Supply and fixing in replacement of heating element 1.5 KW capacity round/triangular/banana/inbuilt thermostat pipe type for geyser of any type/Make and capacity including making necessary electric connections and testing the geyser complete all as directed. Note : The petty items such as nut, bolt, clamps etc are deemed to be included in quoted rates.
Supply and fixing in replacement of thermostat ISI marked for geyser of any type/Make and capacity , including making necessary electric connections and testing the geyser complete all as directed.
M &L in replacement Stainless steel Geyser tank 25/35 Ltr capacity suitable for fixing in 6/9 nut assembly complete all as specified and directed.
M &L in replacement Stainless steel Geyser tank 50 Ltr capacity suitable for fixing in 6/9 nut assembly complete all as specified and directed.
M &L in replacement of base plate assembly of 6/9 holes suitable for fixing on a geyser tank 25/35/50 Ltr capacity incl Nuts & rubber packing for water tight joint complete all as specified and directed.
Supply and fixing in replacement of steel wired connection 600mm long and C P brass adopter 15 mm dia with washer for geyser of any type/Make and capacity complete all as directed.
Supply and fixing in replacement of CP non return valve in position internally screwed on one end and externally screwed on other ends, suitable for iron pipe of size 15mm dia, suitable for geyser of any type/Make and capacity complete all as directed.
Supply and fixing in replacement of indicator lamp red/green suitable for geyser of any type/Make and capacity including making necessary electric connections and testing complete all as directed.
Supply and fixing in replacement of PVC insulated PVC sheathed 3 core 1.5 sqmm copper conductor multistranded cable complete all as specified and as directed
S&F in replacement PVC plug top, 3 pin 16 Amps, 230 Volts, 50 Hz. Complete all as specified and directed
S&F Steel fastneer of 4" long and 8mm dia with Nuts & washer complete all as specified and as directed.
S & F in replacement of PVC flexible pipe 20mm dia complete all as specified and directed.
S& F in replacement of Static Energy Meter single phase electronic type with LCD display of capacity 10-40A including connection with seal and sealing wire including taking out the old u/s and depositing to MES store yard complete all as specified and as directed Make Benlo/L&T/Havells/HPL
S& F in replacement of Static Energy Meter three phase electronic type with LCD display of capacity 10-60A including connection with seal and sealing wire including taking out the old u/s and depositing to MES store yard complete all as specified and as directed Make Benlo/L&T/Havells/HPL
Material and labour for earthing complete with GI earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground not less than 2.25 mtrs below ground level with top edge of plate not less than 1.5 mtr deep below normal ground level connected to galvinised earth wire 4 mm by means of nuts, bolts and check nut to earth plate and to main board or DB including necessary PCC 1:2:4 type B-1 pit, cover frame , GI pipe 15 mm dia light grade for protection and GI pipe 20 mm dia medium grade for watering with funnel, wire mesh, salt and charcoal dust all over the plate all as specified and as directed.
Taking down Window/Split Type Air Conditioner of any make, size of 1.5/2 Ton capacity from existing site for servicing by dismantling all electrical items/connected parts and spray cleaning by means of electric air blower and water descaling by using acid on both side of cooling coil and condenser cleaning with nylon brush and washing with clean water to ensure proper cleaning before reassembling complete unit and refixing at site including testing and commissioning complete all as specified & as directed at site to the entire satisfaction of GE. Note :- (a) Parts found defective after dismantling of ACs requiring replacement will be measured and paid separately under relevant items described here in after however other parts required for dismantling/reassembling of the ACs will be deemed to be included in the quoted rate.
Material and labour for replacement of rotary type compressor for window type AC cap 1.5 TR Make and type as per existing compressor making suction pipe and discharge pipe connections with copper welding/brazing making it leak proof. Pressure testing vacuuming complete all as specified and as directed.
Material and labour for replacement of rotary type compressor for Split AC cap 1.5 TR Make and type as per existing compressor making suction pipe and discharge pipe connections with copper welding/brazing making it leak proof. Pressure testing vacuuming and charging of refrigerant, complete all as specified and as directed. Make LG / Voltas
Material and labour for replacementof rotary type compressor for Split AC cap 2 TR make and type as per existing compressor making suction pipe and discharge pipe connections with copper welding/brazing making it leak proof. Pressure testing vacuuming complete all as specified and as directed.Make LG/Voltas
Material and labour for replacement of starting relay with connecting leads suitable for any type and make of window / Split air conditioner of 1.5 / 2 Ton capacity, complete all as specified and as directed.
Material and labour for detecting leakage in window type/Split AC’s cap 1.5/2 TR by pressure testing and making it leak proof by copper welding/brazing, vacuuming and charging of refrigerant any type as per previous to pressure as per manufacturer specification complete all as specified & directed
Material and labour for replacement of front grill suitable for any type and make of window air conditioner 1.5 T R capacity having good aesthetic look good quality complete all as specified and as directed.
Material and labour for replacement of double shaft fan motor 1/5 HP for Window AC 1.5 TR Make and type as per existing motor, complete all as specified and as directed.
Material and labour for replacement of single shaft fan motor 1/5 HP for Split AC 1.5 / 2 TR Make and type as per existing motor, complete all as specified and as directed.
Material and labour for replacementof capacitor Running Cap 36 to 45 Mfd suitable for operating voltage 240 Volt, 50 HZ, complete all as specified and as directed.Make : Surya/Usha/TIBCON/Tibcap
Material and labour for replacement of starting capacitor 80-100 Mfd, complete all as specified and as directed. Make : Surya/Usha/TIBCON/Tibcap
Material and labour for replacement of starting capacitor 120 Mfd, complete all as specified and as directed. Make : Surya/Usha/TIBCON/Tibcap
Material and labour for replacement of blower motor capacitor 6 mfd suitable for operating voltage 240 volt, 50 HZ, complete all as specified and as directed.Make : Surya/Usha/TIBCON/Tibcap
Material and labour for replacementof air filter element for 1.5 / 2 ton window/ Split type air conditioner of any make and type as per sample, complete all as specified and as directed.
Material and labour for replacement of thermostat suitable for any type and make of window/ Split type Air conditioner 1.5/2 ton capacity, complete all as specified and as directed.Dasspass/Theeta/ Denfos / Indfos
Material and labour for replacement of blower motor 0.5 HP with blower blade assembly complete in all respect for operating voltage 240 volts, 50 HZ and for any type or make of split air conditioner of 1.5/2 ton capacity, complete all as specified and as directed.
Material and labour for replacement of swing motor assembly complete in all respect for operating voltage 240 volts 50 HZ and for any type and Make of window /Split type air conditioner of 1.5/2 Ton capacity, complete all as specified and as directed.
Supply and fixing in replacement of Remote suitable for window/split AC of 1.5/2 TR capacity complete all as specified Make LG / Voltas
Supply and fixing in replacement of PCB card suitable to run window AC any capacity and indoor unit of Split AC any type or capacity complete all as specified and and as directed
Supply and installation of Voltage stablizer 4KVA Capacity, range 170V to 270 Volts, 50 HZ, including depositng the old u/s stabliser to MES store yard complete all as specified and as directed.Make Bluebird/ V guard / Volini
Supply and fixing in replacement of Outdoor unit mouting bracket fabricated out of MS sheet including nuts and bolts complete all as specified and directed
Supply and fixing in replacement a bunch comprising of copper tube 3/8 inch in liquid line and copper tube 1/8 inch in gas line duly insulated including single run of 3 core pvc sheathed copper conductor cable 2.5 sqmm complete all as specified and as directed.
SREE BABA TRADERS
Microsys Controls India
M P TYAGI ENGINEERS AND CONTRACTORS
M/s S.G. BUILDERS
POONAM ENTERPRISES
m/s VK construction company
Saini Enterprises
CUCKOO ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .