Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.3 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹10.0 L+₹95,790 (10.6%)Rejected-Finance 102 VYAS COLONY NEAR AIR FORCE JODHPUR 342011 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342011 | L2 | Rejected-Finance HIGHER AMOUNT QUOTED |
Tender Value
Refer Docs
EMD Value
₹19,800
Closing Date
19 Dec 2020, 4:00 pmClosed
AGE I UDAIPUR
ASST. GARRISON ENGINEER (I) EKLINGGARH CANTT, UDAIPUR (RAJ.) - 313001
REPAIR/MAINT TO DESERT COOLER, AIR CONDITIONERS, DEEP FREEZER, REFIRGERATOR AND WATER COOLERS
2020_MES_400039_1
8583/E8/AGE I UDAIPUR
Open Tender
Civil Works
Item Rate
180 days
ARMY AREA UDAIPUR
AS PER TENDER DOCUMENTS
5 documents required · 5 mandatory
₹500
AGE I UDAIPUR
₹19,800
Yes
18 Jan 2021
3 Dec 2020
21 Dec 2020
3 Dec 2020
19 Dec 2020
5 Dec 2020
Amount
Supply and replace three speed desert cooler fan motor suitable for 4000/5000 CFM output complete with MS fan blades, bracket, nut bolt and complete accessories as required at site . MAKE : COOL HOME/ KHAITAN/ POLAR/ SNOW COOL
Supply and replace submersible water pump suitable for desert cooler . MAKE : COOL HOME/ KHAITAN/ POLAR/ SNOW COOL/ LITTLE PUMP
Supply and replace grass wood pad for Iron body desert cooler including binding wire etc as required.
Supply and replace grass wood pad for Wooden body desert cooler including batten for wooden cooler as required.
Supply and replace of PVC net for wooden cooler grass wood pad of wooden desert cooler.
Material & Labour for replacement of complete body of desert cooler made out of 20 SWG plain GI sheet including water tub and window grill not less than 20 SWG plain GI sheet complete with PVC front grill and Switch -02 Nos for fan and pump and 01 Nos of fan regulator and PVC connection pipe and Fan motor stand made out of MS flat complete with all nut bolts and washer complete all as directed suitable for existing desert cooler fan motor and pump in location and position
Material & Labour for 22 SWG plain GI sheet side grill 2 nos and 1 no. rear grill having suitable for existing desert cooler in location and position
Supply and replace PVC distribution cup with pipe and nozzle for water cooler
Supply and replace of old detoriated wooden frame for desert cooler size 20 x 28 x 34 inch assembled with teak wood incl batten and pipe etc all as directed
Material & Labour for 20 SWG plain GI sheet water tub for wooden body desert cooler having size 800mm x 600mm x depth not less than 200 mm an all as directed suitable for existing desert cooler in location and position
Supply and replace of old broken front PVC grill for wooden frame desert cooler/ GI Sheet desert cooler complete all as directed
Material & Labour for supply and replacement of leg set for desert cooler fan each set of four leg
Material & Labour for spray painting two coats of synthetic enamelled paint blue colour for iron body and yellow colour for wooden body desert cooler on exterior surface and one coat of black colour on interior of iron body wooden cooler surface after scrapping old painted surface in location and position all as directed and specified by Engr-in Charge
Supply and replace PVC insulated and sheathed flexible 1100 volts grade 3 core multistranded copper conductor of size 40 / .0076 cable.
Supply and replace PVC insulated and sheathed flexible 1100 volts grade 3 core multistranded copper conductor of size 70 / .0076 cable.
Supply & replace 3 pin plug top 15 Amp 240 volts AC.
Supply & replace 3 pin plug top 5/6 Amp 240 volts AC.
Supply and replace PVC connection of size 15 mm dia with PTMT nuts, 450mm long rayon braided pipe with brass CP nuts and nylon washers.
Supply and replace PVC connection of size 15 mm dia 600mm long rayon braided pipe with brass CP nuts and nylon washers.
Supply and replace hermatic sealed compresser unit suitable for existing make of refrigerator of cap 286 /310 ltrs. Make of compressor : DANFOS/ LG/ VOLTAS/ TECUMSHAH / KELVINATOR
Supply and replace hermatic sealed compresser unit suitable for existing make of refrigerator of cap 165/175 ltrs.DANFOS/ LG/ VOLTAS/ TECUMSHAH / KELVINATOR
Supply and replace defrost type thermostate suitable for refrigerator Make :- Ranutrol/indofoss
Supply and replace over load relay suitable for refrigerator Make :- Ranutrol/PAC
Supply and replace lamp suitable for refrigerator
Supply and replace evaporator coil suitable for refrigerator of cap 286 / 310 ltrs.
Supply and replace evaporator coil suitable for refrigerator of cap 165 ltrs.
Material & Labour for flushing with pressurising the system, leakage testing vacuumisation and gas charging at apprporiate pressure including testing at site for refrigerator of cap 286 / 310 ltrs.
Material & Labour for flushing with pressurisingthe system, leakage testing vacuumisation and gas charging at apprporiate pressure including testing at site for refrigerator of cap 165/175 ltrs.
Supply and replace magnetic rubber door gasket suitable for refrigerator
Supply and replace magnetic rubber door gasket suitable for deep freezer of any cap
Supply and replace push type door switch suitable for refrigerator of any cap /make.
Supply and replace door lock with with two key set suitable for all type of refrigerator of any cap / any make.
Taking out old unsv / broken accessories of refrigetor of any cap and S & F new accessories like vegetable tray, glass / Wire mesh tray , 02 Nos of ICE tray, door rack/ tray ,chiller tray etc complete of existing type and cap of refrigerator of any make
Supply and replace hermatic sealed compresser unit suitable for any make of water cooler of cap 80 / 40.
Supply and replace hermatic sealed compresser unit suitable for water cooler of cap 100/120 ltrs of any make.
Supply and replace thermostate suitable for water cooler. MAKE : indfoss /denfoss.
Supply and replace over load relay suitable for water cooler of cap 80/40 ltrs
Supply and replace PVC float valve 15 mm complete suitable for water cooler
Supply and replace fan motor with blade for condensing coil suitable for water cooler of cap 80/40 or 100/120 ltrs.
Supply and replace starting capacitor 36 mfd suitable for water cooler of cap 80/40/100/120 ltrs.
Material & Labour for flushing, pressurising the system , leakage testing vacuumisation and gas charging at apprporiate pressure including testing at site for water cooler of cap 80/40 or 100/120 ltrs.
Supply and replace CP lift cock 15mm with connection nipple suitable for water cooler .
Supply and replace CP Push cock 15mm suitable for water cooler .
Supply and replace CP drain water tray as per existing suitable for water cooler .
Supply and replace PVC drain pipe for CP drain out water tray as per existing suitable for water cooler .
Maintenance and repair for inbuilt RO system in storage type water cooler for capacity 40/80/100 ltr storage including supply and replacement of complete RO membrane, Sadimentation filter, carbon filter, precarbon filter, SMPS, diapharm pump (pressure pump), controll switch, auto control switch flow pipe in any length, connector and any small parts incl PVC pipe etc all as specified and directed. note:- minimum two free servicing incl replace of filters and membranes to be done up to completion of contract, & one after completion upto six months ii) RO repair/maintenance /cleaning of filter should be attend after within 24 hours after receiving the complaints.
Supply and replace hermatic sealed compresser unit suitable for window type AC cap. 1.5/2.0 ton of make: technomush/kirloskar/ Voltas/Carrier/LG
Material & Labour for flushing, pressurising the system , leakage testing vacuumisation and gas charging at apprporiate pressure including testing at site for window type AC cap 1.5/2.0 ton.
Supply and replace starting capacitor suitable for window/ split type AC cap 1.5/2.0 ton.
Supply and replace running capacitor suitable for window/split type AC cap 1.5/2.0 ton .
Supply and replace thermostate suitable for window/split type AC cap 1.5/2.0 ton of MAKE : indfoss /denfoss.
Supply and replace overload relay suitable for window/ Split type AC cap 1.5/2.0 ton
Supply and replace blower fan motor suitable for window/ Split type AC cap 1.5/2.0 ton
Supply and replace blower fan for blower motor suitable for window/ Split type AC cap 1.5/2.0 ton
Supply and replace micro filter suitable for window type/split type AC cap 1.5/2.0 ton
Supply and replace front PVC grill suitable for window type AC cap 1.5 ton as per existing sample.
Material & Labour for taking down AC split type complete inner and outer unit and relocate as per given site complete including refixing inner & outer unit piping with insulation and testing all as directed.
Supply and replace hermatically sealed rotary type compressure suitable for split type AC cap. 1.5/2.0 ton of make: technomush/kirloskar/ Voltas/Carrier/LG
Material & Labour for flushing, pressurising the system , leakage testing vacuumisation and gas charging at appropriate pressure including testing at site for split type AC cap 1.5 ton.
Supply and replace swing motor suitable for split type AC cap 1.5/2.0 ton
Supply and replace remote controller suitable for split type AC cap 1.5/2.0 ton as per existing of any make any model
Supply and replace front PVC grill suitable for split type AC cap 1.5/2.0 ton as per existing
Supply only compressor sealed hermatic 1.5 ton sutable for window AC of make: LG
Supply only compressor sealed hermatic 2.0 ton sutable for window AC of make: LG
Taking out old unsv indoor unit of split Ac of 1.5 Ton capacity complete with filter, Blower with fan, PCB and remote control and connceting wire complete suitable for existing type of AC unit
Taking out old unsv outdoor unit of split Ac of 1.5 Ton capacity complete with fan with blower motor, Condensing coil, control unit complete suitable for existing type of AC unit except compressor
Taking out old unsv copper connection pipe line small and big type for supply and return refrigerant gas complete with insulation complete fixed to wall with suitable saddle and testing (both small and big line to measured as one length )
Taking out old unsv stablizer and supply and fix stablizer suitable for operation of 1.50 ton Slit and window Ac and single phase 190 V to 230 V electric supply
NOTE:- 1) For serial item No 1 to 69 repair shall be caried out at site or at MES store yard as directed by Engr-In-Charge or as given site without any extra cost for transportation. 2) Machinary will not allowed to carry out in out side workshop.
M/s Shiv Builder and Suppliers
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .