| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.9 LAccepted-Finance 36 204 N NO 52 204 V O C NAGAR THANGAMAPURIPATTINAM METTUR DAM 636 402 | METTUR DAM | SALEM | TAMIL NADU | 636402 | 1 | Accepted-Finance Satisfied | |
| 2 | 2₹4.5 L+₹1.6 L (55.1%)Accepted-Finance M 18 HOUSING BOARD UNIT MADAYANKUTTAI POST METTUR DAM 636 452 | METTUR DAM | SALEM | TAMIL NADU | 636452 | 2 | Accepted-Finance Satisfied |
| Sl No | Description | Qty | Unit | KEEN ERECTORS L1 | THIAGARAJAN ENGINEERING CONTRACTOR L2 |
|---|---|---|---|---|---|
| 1.00 | Charges for complete overhauling of Weak Base Anion Ion Exchanger and related works
Charges for manhole door opening, back washing, cleaning of internals by Air Scouring | 225 | Mtrs | 327 ₹73,575 Lowest | 500 ₹1,12,500 |
| 2.00 | Charges for removal of entire resins from ion exchanger tank manually, cleaning & checking the organic fouling and refilling of resins after completion of work | 4,500 | Point | 12 ₹54,000 Lowest | 20 ₹90,000 |
| 3.00 | Charges for dismantling Inlet distribution Header & its bends and re-assembling the same, after completion of work | 4,500 | Point | 5.2 ₹23,400 Lowest | 6 ₹27,000 |
| 4.00 | Charges for dismantling of MSRL Lateral Support Members, PVC Laterals & Middle collection Header, Cleaning & checking the healthiness of PVC Laterals, renewing the laterals if necessary & assembling and re-assembling Middle collection Header, PVC Laterals & MSRL Lateral Support Members., after completion of work | 1 | Time | 19,800 ₹19,800 Lowest | 32,000 ₹32,000 |
| 5.00 | Charges for dismantling of bottom collecting deflector plate & out let pipe, Cleaning & checking the healthiness of PP Double Decker Strainer buttons & Resin Trap, renewing the Strainer buttons & Resin Trap if necessary, assembling all Strainer buttons & Resin Trap and then closing the bottom collecting deflector plate & out let pipe | 1 | Time | 63,500 ₹63,500 Lowest | 1,05,000 ₹1,05,000 |
| 6.00 | Charges for Resin washing, open back washing & water draining. Measuring resin level after water draining, to top up the resins for required level if necessary, and lifting the man hole dummy from ground and closing | 100 | Nos. | 110 ₹11,000 Lowest | 170 ₹17,000 |
| 7.00 | Charges for complete overhauling of Strong Base Anion Ion Exchanger and related works
Charges for manhole door opening, back washing, cleaning of internals by Air Scouring | 200 | Nos. | 192 ₹38,400 Lowest | 300 ₹60,000 |
| 8.00 | Charges for removal of entire resins from ion exchanger tank manually, cleaning & checking the organic fouling and re filling of resins after completion of work | 100 | Nos. | 25 ₹2,500 Lowest | 37 ₹3,700 |
| 9.00 | Charges for Consumables & Hire charges for T&Ps | 1 | LS | 6,800 ₹6,800 Lowest | 7,200 ₹7,200 |
Tender Value
Refer Docs
EMD Value
₹4,300
Closing Date
18 Aug 2025, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer /Mechanical-I/MTPS-I
Office of the Superintending Engineer / Mechanical -I Mettur Thermal Power Station- I Mettur Dam-636406
MTPS I BM Unit IV Boiler Pressure parts AOH 2025 Tube thickness survey Water wall buffing providing platform renewal of shroudings and allied works
2025_EB_587922_1
CE / MTPS-I / SE / M-I / BM /OT.210 / 2025-26
Open Tender
Power/Energy Projects/Products
Works
20 days
Mettur Thermal Power Station-I / Mettur Dam
As per the Tender Specifications
4 documents required · 4 mandatory
₹0
₹4,300
Yes
21 May 2026
4 Aug 2025
19 Aug 2025
4 Aug 2025
18 Aug 2025
4 Aug 2025
Amount
Charges for complete overhauling of Weak Base Anion Ion Exchanger and related works Charges for manhole door opening, back washing, cleaning of internals by Air Scouring
Charges for removal of entire resins from ion exchanger tank manually, cleaning & checking the organic fouling and refilling of resins after completion of work
Charges for dismantling Inlet distribution Header & its bends and re-assembling the same, after completion of work
Charges for dismantling of MSRL Lateral Support Members, PVC Laterals & Middle collection Header, Cleaning & checking the healthiness of PVC Laterals, renewing the laterals if necessary & assembling and re-assembling Middle collection Header, PVC Laterals & MSRL Lateral Support Members., after completion of work
Charges for dismantling of bottom collecting deflector plate & out let pipe, Cleaning & checking the healthiness of PP Double Decker Strainer buttons & Resin Trap, renewing the Strainer buttons & Resin Trap if necessary, assembling all Strainer buttons & Resin Trap and then closing the bottom collecting deflector plate & out let pipe
Charges for Resin washing, open back washing & water draining. Measuring resin level after water draining, to top up the resins for required level if necessary, and lifting the man hole dummy from ground and closing
Charges for complete overhauling of Strong Base Anion Ion Exchanger and related works Charges for manhole door opening, back washing, cleaning of internals by Air Scouring
Charges for removal of entire resins from ion exchanger tank manually, cleaning & checking the organic fouling and re filling of resins after completion of work
Charges for Consumables & Hire charges for T&Ps
THIAGARAJAN ENGINEERING CONTRACTOR (BID ID -1431578)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
cancelled_1.pdf
pdf • 0.17 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.82 MB
BOQ_702405.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .