Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.0 LAccepted-AOC | L1 | Accepted-AOC Being the lowest and reasonable bidder | |
| 2 | L2₹42.7 L+₹9.6 L (28.9%)Rejected-AOC 5 A LANE 1 GREATER KAILASH JAMMU J K 180011 | JAMMU | JAMMU AND KASHMIR | 180011 | L2 | Rejected-AOC Being the other than lowest bidder | |
| 3 | L3₹43.4 L+₹10.3 L (31.0%)Rejected-AOC | L3 | Rejected-AOC Being the other than lowest bidder | |
| 4 | L4₹48.0 L+₹14.9 L (45.0%)Rejected-AOC | L4 | Rejected-AOC Being the other than lowest bidder |
Tender Value
₹36.2 L
EMD Value
₹72,500
Closing Date
16 Apr 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CWE Nagrota
HQ CWE Nagrota Co 56 APO
SPECIAL REPAIR TO BLDG NO NP-26 OF 16 CPU, SPECIAL REPAIR OF DRAINAGE AT OTM AND MD ACCN OF HQ 16 CORPS CAMP, PROVN OF GUARD ROOM FOR 08 X OR AND COVERED SHED FOR BATHING POINT IN ASCON C-HILL UNDER GE NAGROTA
2022_MES_503673_3
CWE/NGT-43/2021-22
Open Tender
Civil Works
Item Rate
182 days
Nagrota
As per NIT and tender documents
8 documents required · 8 mandatory
₹500
Yes
GE Nagrota
₹72,500
Yes
28 Apr 2022
28 Mar 2022
18 Apr 2022
28 Mar 2022
16 Apr 2022
4 Apr 2022
28 Mar 2022 - 4 Apr 2022
60 days
Amount
Surface dressing n.exc 30 cm deep and averaging 15 cm deep and getting out as in hard/dense soil complete all as specified.
Excavating in trenches in any type of soil, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and getting out complete all as specified.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified.
Removing excavated material n exc 50 m and depositing where directed at a level n exc 1.5 m above the starting pointturning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified.
Cement concrete in foundations, filling and mass-concrete 1:4:8 type D2 using 40 mm graded agg complete all as specified.
RCC M-25 as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete complete all as specified.
Reinforced cement concrete M-25, using 20mm graded crushed stone aggregate, as in columns, pillars, posts, struts etc.
Reinforced cement concrete M-25, as in beams, cantilevers, breassummers, lintels over 1.5 m span,, complete all as specified and as directed.
Reinforced cement concrete M-25 as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in the shelves and the like including 15 mm th plastering with water proofing compound as directed laid/made to slope as in RCC roof surfaces complete all as directed
M & L formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified
Formwork to sides of pillars, posts, struts, piers, columns, and stanchions with rough finished surface of concrete in square, rectangular, polygonal complete all as specified.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping)
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified
Mild steel TMT bars 6 to 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified
All as per srl item no 15 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders
M&L brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius in cement mortar 1:6 for parapet walls / railings/ manholes /drains etc.complete all as specified
M&L brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius in cement mortar 1:4 for parapet walls / railings/ manholes /drains etc. complete all as specified.
Material and labour for 15mm thick rendering in Cement and Sand mortar 1:6 over brick or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed
Material and labour for 15mm thick rendering in Cement and Sand mortar 1:4 over brick or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for 5mm thick rendering in cement and sand mortar 1:4 on ceiling, chajja surfaces (concrete surfaces) finished even and smooth wihtout using extra cement, complete all as specified and directed.
Material and labour for three coats of white wash on ceiling surfaces including preparation of new surfaces complete all as specified and directed.
Preparation of new surfaces of wall (including cornices, pilasters etc) and applying two coats of oil bond distemper(OBD) on wall surfaces complete all as specified.
Preparing new wall surfaces, and applying two coats of cement base paint over coat of primer complete all as specified.
M & L 40 mm th PCC 1:2:4 type B0 using 12.5 mm graded stone agg as in damp proof course to horizontal or vertical surfaces including necessary formwork complete all as specified.
M & L 75mm th PCC 1:4:8 type D2 using 40 mm graded stone agg as in sub base flooring complete all as specified.
Spreading and levelling sand in layers not exceeding 25cm thick and well ramming including watering as required complete all as specified.
M & L Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified
All as per srl item no 28 above but on vertical surfaces of wall
Hardcore of gauge exc 63 mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface complete all as specified
Material and labour for 75mm thick plain cement concrete type C-1 1:3:6(Using 20mm graded crushed stone aggregates) as in plinth protection finished fair and even without using extra cement complete all as specified and directed. Note : The plinth protection shall be laid in panels and length of the each panel shall not be more than 2.00 metre all as directed. 6mm joints filled with 85/25 grade bitumen and sand (1:3 ratio) shall be provided. No deduction for joints shall be made while making payment against the above item.
S & F 35 mm thick, factory made, second class hard wood, plain framed hammer marked, Double panelled shutter (two panel)with lock rail and panel of 9 mm BWP commercial ply both face including 1.00 mm thick sunmica (lamination) on both sixes of p-anel and 20 mm x 20 mm x 10 mm wooden beading all round the panel. The size of rail and stile as per IS : 1003 (Part I) kiln seasoned and chemically pressure treated all as specified including french polishing matching to the sumica lamination all as specified .
S & F Box type Steel windows with double shutters (inside for wiremesh & out side for glass), incl guard bar,hinges, steel handle, tower bolt and steel peg stay complete with glazing bar dovetailed or welded including a coat of red oxide after preparation of surface before fixing complete all as specified.
S&F Steel ventilators fixed type with glazing bars complete all as specified & directed.
S&F galvanised mild steel pre painted wire cloth 0.56 mm nominal dia of wire & avg width of aperture 1.18 mm in fixed with tinned tacks.
M &L Pressed steel frames of size 125mm X 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete as specified.
S&F band straps, supports, hold fast etc made F1 20 x 5 & welded to steel chowkhat (FE 410W(Gde-E-250) Quality B complete all as specified and directed
Cutting holes into or through brick walls built in cement mortar and making good in cement mortar 1:3 of cement concrete 1:2:4 type B1 exc half brick not exc full brick as reqd, superficial area not exc 150 sq cm complete all as specified and directed.
M&L for 10 mm rendering in CM 1:4 over roof surfaces finished even and smooth without using extra cement complete all as specified
M&L for Applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 Kg per sqm including bitumen primer @ 3.5Kg/Sqm
M&L for Laying APP (atatic polypropylene) modified membrane 3mm thick and weighing not less than 3 kg/sqm with 160 GSM/sqm, non woven polyester mat as center core reinforcement, laid with 75 mm side over lap and 100mm end over lap, the membrane has to be laid with LPG tourch and over lap sealed and finished neat over roof including a coat of bitumen 85/25 at the rate of 1.2 Kg per sqm over APP membrane.
M&L for Concrete bed PCC 1:4:8 to drain pipes of 150mm dia including packing under, and haunching against the side of pipes after they are laid and tested, complete all as specified and as directed.
M&L for salt glazed stone were drainpipes grade ‘A’ ISI marked laid to slope in trenches, jointed in CM (1:1) and tested complete of size 150mm dia. Complete all as specified.
S & F 100 mm size butt hinges medium weight cold rolled mild steel complete all as specified.
S&F Aluminium andised barrel tower bolts extruded section of size 200mm, all as specified and directed
S&F Cast type aluminium alloy handles anodised of size 150mm size, complete all as specified and as directed.
Aluminium alloy, anodised, sliding door bolt of length 300mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of sections or cast-aluminium extruded alloy and fixed complete all as specified and directed.
M&L two coats of synthetic enammelled paint on steel surfaces over a coat of red oxide primer exceeding 10 cm width or girth including preparation of new surfaces complete all as specified.
M&L two coats of synthetic enammelled paint on wooden surfaces over a coat of pink primer exceeding 10 cm width or girth including preparation of old surfaces complete all as specified
S&F glazing complete with sheet glass ordinary quality 3 mm thick fixed with oil putty in square n.exc 0.5 sqm in each pane.
S&F chromium plated brass shower rose with or with shower arm long size including fixing steel pipe or union 125 mm size.
Anti-termite treatment of soil by treating soil along with external perimeter of building at the rate of 2.25 ltr of emulsion per meter of the perimeter wall complete all as specified.
Anti-termite treatment of soil by treating the top surface of filled earth at the rate of 5 ltrs of emulsion per square mtr of surface complete all as specified.
Anti-termite treatment of soil by treating soil under plinth protection at the rate of 5 ltrs of emulsion per square metre of surface area complete all as specified.
Treating the backfill in contact with foundation at the rate of 7.5 ltrs of emulsion per square mtr of vertical surface (area of the sub structure in contact with backfill to be measured), complete all as specified.
S & F in rep 110 mm dia PVC (SWR) rain water pipes single socketed, fixed to walls with PVC clamps complete all as specified.
S & F in rep 110 mm dia PVC (SWR) bends for rain water pipes, fixed to walls complete all as specified.
M&L for non skid ceramic tiles, coloured, joint less, minimum size 300mm x 300mm x 7mm, first quality, as in floor etc, set and jointed with neat cement slurry and pointed in white cement with pigment to match the shade of tiles over and including 15mm thick rendering in cement mortar 1:4 complete all as specified and directed.
M&L for glazed ceramic coloured tiles 350mm x 250 mm x 7mm thick, first quality, as on skirting , dados, walls etc set and jointed in neat cement slurry and pointed in white cement with pigment to match the shade of tiles over and including 15mm thick rendering in cement mortar 1:4 complete all as specified and directed.
S & F vitreous China squatting pan `Orrisa' pattern, size 580 X 440mm white, with integral foot rests & 100mm bore CI `P' trap complete incl making good floor etc. complete all as specified and directed.
S&Fwash basins, vitreous China flat back, size 550 X 400mm incl CP pillar tap, 32mm size waste coupling, 15 x 450 mm long PVC connection, 32mm size PVC waste pipe & angle brackets 30x30x450mm complete.
S & F PVC valveless syphonic action type low level flushing cistern (Dual type) `White' with inlet, ball valve, float, handle, PVC connection & 32mm dia CP flush pipe ( long type for squatting pan) incl brackets complete all as specified and directed. .
S&F angular stop cock rubic series , cast copper alloy chromium plated, fancy type, screwed both and for iron pipe or for union, suitable for 15mm bore pipe, complete all as specified and directed.
S&F stop valve 15mm bore, cast copper alloy, brass, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions, complete all as specified and directed.
S&F bib taps, long body with wall flange, chromium plated, cast copper alloy fancy type with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule, suitable for 15mm bore pipe, complete all as specified and directed.
S&F 100 mm dia grating of PTMT open able incl fixing to floor trap with white cement complete all as specified and directed. .
S&F cast iron soil, waste and vent pipe 100mm dia bore (ISI Marked) sand cast pipes, in any length with or without ears, in cement joint, laid in trenches or fixed in walls etc, complete all as specified and directed.
M&L for CI floor trap 75mm dia with CI grating including jointing to waste pipe in run lead complete and making good the disturbed surface to match the existing surface, complete all as specified and directed.
M&L for 15mm dia GI tubing medium grade with all fittings to walls, ceiling or laid under floors complete all as specified and directed.
M&L for 20mm dia GI tubing medium grade with all fittings to walls, ceiling or laid under floors complete all as specified and directed.
S&F CI bends any radius 100mm complete all as specified and directed.
S&F CI bends any radius 75mm complete all as specified and directed. .
S&F Cast Iron vent cowl 100mm complete all as specified and directed.
M&L (SWR) guly trap 125/110mm setting and jointing with solvent cement complete all as specified and directed.
S & F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, supplying & fixing in opening as per specification & drawing
S & F Factory Made Solid PVC Moulded Door Shutters 28 to 30 mm thick (stile), with 2,4 or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front Face & 2mm Plan colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing
S&F 1000 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) double layered (ISI Marked) hoisted and fixed in position, including ball brass valve 20mm bore & tank nipple, with ball valve high pressure PTMT complete all as specified.
S&F Vitreous China Urinal, full stall type, white with PTMT waste fitting, PVC waste pipe, brass CP urinal spreader including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws complete all as specified and directed.
S & F stop valve 20mm bore, cast copper alloy, brass, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions, complete all as specified and directed.
S & F PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and directed.
Providing precast cement concrete 1:2:4 type B-1 as in window or door cills, lintels, steps, copings pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, anchorage blocks, with plain fair faces, including chamfers, weatherings, throating etc. and setting in cement mortar 1:4 complete all as specified and directed.
PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate, as in benching, coping etc., and similar items including weathering slightly rounded or chamfered angles and throating on top of chajjas, rails, cills etc., including necessary form work, complete all as specified and as directed.
M&L for 100 mm thick PCC 1:3:6 type C2 (using 40 mm graded aggregate) as in footpath and sub bases of floors, etc. complete all as specified and directed.
S&F 60mm thick factory made machine pressed precast concrete interlocking coloured paver block, with grey cement and pigment, any shape and size conforming to IS 15658-2006 of M-35 grade laid over and including sand cushioning of 50mm average thickness complete all as specified. (sand cushioning measured and paid separetely)
25 mm thick sand cushioning for interlocking paver blocks including spreading and consolidating complete all as specified and directed. Note: (i) Sand shall be coarse sand as specified. (ii) Punned down thickness shall be considered for measurement and payment.
Gun metal globe valves, with iron wheel head, Stop valves ,cast copper alloy, screwed down high pressure , screwed both ends for iron pipe or for union 20mm dia
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft soil, complete all as specified and directed.
PCC 1:2:4 type B-2 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete.
M&L steel work in tubular truss including sprcial shaped washer ets complete using ERW or induction butt welded tubes conforming to I.S 1161-1979 grade st-240
S&F mild steel bands, straps, supports or stays for rainwater, ventilating pipes incl bolts , hooks for large gates, pintle hinges, large hasps and staples, chains, hand made sliding bolts, gusset plate clamps, hold fast, and wall tie , hook for hanging fans, plain angle cleats for securing purlins trusses or rafters, knee piece inserts, two way and three way straps, plate washers and all similar small articles conforming to FE-290 Gde and E-165 all as directed and specified by Engr-in-Charge
Preparing surfaces of new steel and iron work new or old of any description and girth not otherwise described and treated with tar or coat tar black paint complete all as specified and directed.
S&F for Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
S&F for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate in coping/Surface Channel Drain
M&L For extra for forming fair finished drain or channel 45cm inner girth in cement concrete using extra cement including form moulds mitred/stopped ends etc. complete.
Demolition of brick work/Stone Boulder Masonry built in cement mortar including all quions, arches, pillars etc but excluding ashlar facings dressed stone work and precast concrete articles.
Demolition of cement concrete (unreinforced) in ground floors and paving not exc 15cm thickness complete all as specified. .
Demolition of cement concrete (unreinforced) of any description and any position not other wise specifically provided complete all as specified.
M&L for 15mm thick rendering in Cement and Sand mortar 1:4 over brick or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
Pre cast RCC cover slab 1: 2: 4 type B1 using 20mm graded trap stone agg set CM 1:4 complete all as specified and directed.
Taking down chowkats with shutter n. exc 1.5 sqm each. (without taking of shutter from the frame) complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for 20mm thick screed bed or bedding layer of mortar for laying of floor finishes etc. complete all as specified and directed.
M&L of 25mm thick PCC 1:2:4 type B-0 as a sub base to receive topping layer finished even and rough complete all as specified and directed.
M&L for 10mm thick rendering in cement moratr 1:4 as in backing coat for skirting/dados etc all as specified.
S&F 2nd class hard wood 35mm thick glazed and skelton shutters open rebated and prepared to receive glass, gauge etc (without sash bars) edges of framing plain chamfered or rounded fitted with out and mittered beads for member of shutters as specified in SSR Part-I section 8 clause 802 (a) factory made shutters.
Aluminium andised barrel tower bolts extruded section of size 150 mm, all as specified and directed
Material and labour for 50mm thick plain cement concrete type C-1 1:3:6 (Using 40mm graded crushed stone aggregates) as in plinth protection finished fair and even without using extra cement complete all as specified and directed.
Taking down existing plaster of any description on brick wall/ concrete surface including racking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed.
M&L for 10mm thick rendering in Cement and Sand mortar 1:6 over brick or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed
M&L for 15mm thick rendering in Cement and Sand mortar 1:4 over brick or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for applying two coats of cement base paint including complete removal of existing treatment on old surfaces complete all as specified and directed.
M/L 75 mm thick Cement concrete type B2, 1:2:4 (using 40 mm graded granite stone aggregate) in base of flooring/ hard standing finished even & smooth w/o using extra cement complete all as specified and directed.
M & L for chequered cement concrete tiles 25mm thich set, joined and pointed in neat cement slurry in floors with grey cement and no pigment over 20 mm thick screed be in CM 1:4, all as directed by EIC .
Dismantling of wrought iron or mild steel work of any description complete all as specified and directed.
Dismantling of corrugated or semi corrugated steel sheeting any gauge,thickness,including Nainital or similar pattern in roof covering complete all as specified and directed.
M&L for 10 mm rendering in CM 1:4 including water proofing compound @2% of cement over roof surfaces finished even and smooth without using extra cement complete all as specified Note:- WPC Measured and Paid Separately.
Supplied only for Integral water proofing compound.
Applying bituminous primer @ 0.40 litre per Sqm over plastered surfaces of roof including parapet surfaces
M&L for preparation of new plastered wall surface and applying two coats of Oil bound distemper over 3mm thick wall care putty on walls etc all as specified.
M&L of cable 1100 V grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 mtr apart including 4 mm suspension wire one twin core cable flat or circular of size 16 Sqmm multi stranded conductor all as specified and as directed.
Taking down ceiling fan any sweep, removing blades ,cleaning the fan completely for dust and dirt as well as oiling & greasing and hanging the same back to its original positions including connecting with three core flexible copper wire to ceiling rose etc after the completion of the point wiring including replacement of old unserviceable fan hook, rubber pad, nut bolts and washers etc, complete, all as specified and directed by Engineer-In-Charge.
Taking down carefully unserviceable Aluminium point wiring complete (light, fan socket, bell or power) with fitting such as switches, ceiling rose lamp holder, regulators, sockets, light fittings etc. and keeping in safe custody for taking credit complete all as specified and as directed by Engineer-in-Charge
M&L for point wiring with PVC insulated unsheathed 1100 volt grade FRLS cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium grade ISI marked not less than 20mm dia ,concealed in wall and surface on ceiling with all conduit fittings & fixing acessories inculding sunken anodised pressed steel terminal box not less than 1.2mm thick covered with 3 mm thick plastic laminated sheet cover of suitable size with brass screws for mounting switches, sockets, regulators with and including 1.5sqmm FRLS multi stranded copper conductor drawing as continuous earth wire connected to main earth and earth dolly complete all as specified for the following :-
(a) One light point controlled by one switch 5 Amp.
(b) One ceiling fan/exhaust fan point controlled by one switch 5Amp
(c) One socket out let 5Amp controlled by one switch on same board.
(d) One socket out let 5 Amp controlled by one switch on independent board.
All as per item No 125 here in before but point wiring with 2.5sqmm FRLS multi stranded copper conductor cable for main circuit and 2.5sqmm cable as earth continuity conductor for one 15Amp socket out let controlled by one 15Amp switch on independent board.
S&F switch piano flush type 5 Amps single pole one way complete,
S&F switch socket combination 2 in 1, 3 pin, 5 Amp flush type complete.
S&F switch socket combination 2 in 1, 5 pin, 5 /15 Amps flush type complete.
S&F of ceiling rose 3 terminal complete PVC/Polycarbonate isolated boly complete all as specified and directed.
S&F stepped type electronic fan regulator flush type 230V, 50 Hz, AC supply, on the existing phenolic laminated sheet etc as required all as specified and directed.
M&L Integrel sleek extruded batten aluminium /CRCA channel fitting with LED 18 watt complete with all accessories and including connecting up with three core twisted flexible copper conductor cable with suitable size of 230V 50 Hz. Cat part no.112181 BLRB-DB 118 ( for batten fitting) & Cat part no. BLRB18W CW (for LED 18 watt ) or equivalent in makes given in particular specifications.
"S&F batten integrated LED channel of 5W, 230V frequency 50/60 Hz integral sleek extruded polycarbonate LED channel with white acrylic cover, Power Factor not less than 0.9 and 5 KV surge protection complete all as specified and directed by Engineer in charge. Make- Bajaj Cat Part No. BCLSB 05 WH, Crompton Cat Part No. LDL-05-CDL, Havells Cat Part No. LHEXBTP7IN1WO05, C&S LTTB1F5WLEDW or equivalent from the makes given in the PS."
M&L LED light fitting 1x9W bulk head luminaries IP 65 complete with all accessories including LED lamp 9 watt , connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V 50 Hz .
S&F for lamp holder PVC/polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
S&F for LED bulb 7 watt complete all as specified and directed.
S&F sheet metal enclosure distribution board SPN 08 way 230 V, 50 Hz, double door with neutral, Earthing bar and din rail complete all as specified and directed.
S&F sheet metal enclosure distribution board SPN 12 way 230 V, 50 Hz, double door with neutral, Earthing bar and din rail complete all as specified and directed.
S&F MCB SPN 40 Amps 10 KA 230 volts "C" series complete.
S&F MCB single pole 6 to 32 Amps 10 KA 230 volts "C" series complete
"S&F exhaust fan 300 sweep, AC, 230/ 250 volts heavy duty complete with louvers, mounting on walls with holding down bolts, nuts, washers & provision of flexible copper conductor cable three core 23/0.0076 size from ceiling rose to fan and testing complete all as specified. Make: Havells cat part No : Refresh air-DBB or equivalent in approved makes"
"S&F of ceiling fan 1200 mm sweep single phase AC 230/240 V complete including grouting of eyebolt of suitable size in ceiling and fixing the fan by mean of suitable bolts, nuts washers and provision of flexible copper conductor cable 3 core 23/0.0076 size from ceiling rose to fan complete all as specified. Make: Havells and cat part No XP-390 plus or equivalent in approved makes."
M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit shall be filled with charcoal dust and common salt all as shown in electrical plate No 5 of MES SSR Part-I 2009 as specified including provision of 15mm dia medium grade GI pipe for earth wire protection and 20 mm dia for watering complete , all excavation and earth work & connecting the earthing to an earthing test point / main switch board as specified and testing on completion complete.
Note:- Schedule of credit of Rs. 7470.50 will be deducted from total amount quoted while accepting the bid. Details of schedule of credit is given in tender documents.
NARESH KUMAR AND COMPANY
M/S P S CONSTRUCTION
Karmnaya Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .