GE AF TUGHLAKABAD
GE AF TUGHLAKABAD SANGAM VIHAR PO NEW DELHI 110080
REPAIR / MAINT OF COOLING APPLIANCE (WINDOW / SPLIT ACs / DESERT COOLERS / REFRIGERATORS, WATER COOLERS, DEEP FREEZERS, VOLTAGE STABILIZER AND WATER DISPENSERS ETC AT 12 BRD, AF STN NAJAFGARH UNDER GE (AF) TUGHLAKABAD
2022_MES_563618_1
GE/TKD-64/2022-23
Open Tender
Civil Works - Others
Item Rate
180 days
GE AF TUGHLAKABAD
MES contractor enlisted having deposited Standing Security with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
8 documents required · 8 mandatory
₹500
GE AF TUGHLAKABAD
₹44,000
Yes
7 Mar 2023
1 Dec 2022
31 Dec 2022
8 Dec 2022
29 Dec 2022
15 Dec 2022
Amount
Removing defective window / Split type air conditioner of any make and capacity from various locations and transporting to contractor's workshop to carry out necessary repair as mentioned in respective item including cleaning the air conditioner with water and air pressure and to replace un-serviceable spares parts and re-fixing at various locations after repairs including testing on load at site complete all as specified and directed by Engr-in-Charge. Note: All spares such as PVC air filter, relay, capacitor, thermostat, contactor, gas drier filter etc, shall be measured and paid separately under supply only item.
M&L for Servicing of split type AC of capacity upto1.5/ 2.0 TR of any make by washing the outdoor unit, condenser coil with soap water jet followed with clean water jet and indoor unit with the help of blower, wipe and clean the unit with dry cloth complete all as specified and directed by Engr-in-Charge. Note: (a) Cost of hiring T&P i.e. blower, pressure pump, bucket, hose pipe, cloth. Dismantling /taking down and re-installation of unit on wall, transport deemed to be included in above rate. (b) Servicing will be done without damaging electric connection/AC parts and testing and commissioning complete.
Taking out and opening carefully blower motor, fan blade / drum of 1.5 / 2 Ton window / split type AC unit & dismantling, cutting and removing the unserviceable copper winding wire of blower motor and rewinding with super enamelled copper winding wire of existing gauge including replacement of unserviceable bushes/bearings, long nuts, bolts etc and reassembling complete all as specified and directed by Engr-in-Charge.
M&L for checking leakages with creating vacuum with dry nitrogen gas for split type air conditioner of 1.5 Ton to 2.0 Ton capacity complete all as specified and directed by Engr-in-Charge.
M&L for gas charging with R22/134a refrigerant up to required quantity to window / split type AC 1.5 / 2 Ton capacity on any make / model including flushing of gas, oil charging, necessary welding and bracing works, checking of leakage and testing on full load complete all as specified and directed by Engr-in-Charge. Note:- No extra payment will be given to contractor to top up the gas in case of leakage from air conditioner.
M&L for spray painting with one coat of synthetic enamel paint of cream tint on internal & external steel surfaces of window / split type A/Cs complete including preparing the existing painted surfaces and writing SM No, MES No etc complete all as specified and directed by Engr-in-Charge.
S&F in repairs of running capacitor 36 MFD 440 VAC for ACs & Water coolers. Make : Havells/Amcap/Epcos
S&F in repairs of running capacitor 45 MFD 440 VAC. Make : Havells/Amcap/Epcos
S&F in repairs of running capacitor 50 MFD 440VAC. Make : Havells/Amcap/Epcos
S&F in repairs of running capacitor 36/6 MFD 440VAC. Make : Havells/Amcap/Epcos
S&F in repairs of running capacitor 45/2.5 MFD 440VAC. Make : Havells/Amcap/Epcos
S&F in repairs of running capacitor 50/6 MFD 440VAC. Make : Havells/Amcap/Epcos
S&F in repairs of running capacitor 50/2.5 MFD 440VAC. Make : Havells/Amcap/Epcos
S&F in repairs of starting capacitor 80 /100 MFD 250 VAC. Make : Havells/Amcap/Epcos
S&F in repairs of starting capacitor 100/120 MFD 250 VAC. Make : Havells/Amcap/Epcos
S&F in repairs of gas drier filter two way/One way for window type AC of any make & capacity complete all as specified and directed by Engr-in-Charge.
S&F in repairs of PVC air filter suitable for window/split type AC of any make & capacity complete all as specified and directed by Engr-in-Charge.
S&F in repairs of blower motor with base plate for 1.5 ton window type AC complete all as specified and directed by Engr-in-Charge. Make : GE/Crompton Greaves
S&F in repairs of blower motor with base plate for 2 ton window type AC complete all as specified and directed by Engr-in-Charge. Make : GE/Crompton Greaves
S&F in repairs of blower motor for 1.5/2 ton split type AC outdoor unit complete all as specified and directed by Engr-in-Charge.
S&F in repairs of blower motor for 1.5/2 ton split type AC indoor unit complete all as specified and directed by Engr-in-Charge.
S&F in repairs of electronic circuit board PCB suitable for window/split type AC indoor unit of any capacity as per the existing model & make complete all as specified and directed by Engr-in-Charge.
S&F in repairs of PVC Drum for split type air conditioners indoor unit of any capacity as per the existing model & make complete all as specified and directed by Engr-in-Charge.
S&F in repairs of blower fan blade suitable for window type AC of any capacity as per the existing model & make complete all as specified and directed by Engr-in-Charge.
S&F in repairs of blower fan blade suitable for split type AC outdoor unit of any capacity as per the existing model & make complete all as specified and directed by Engr-in-Charge.
S&F in repairs of Box type starting relay assembly for window/split type air conditioners of any make / capacity. Make- Tecumseh/Classic/Annapurna.
S&F in repairs of thermostat switch for 1.5 / 2 ton window/split type AC of any make / capacity.
S&F in repairs of PVC insulated and sheathed multistranded copper conductor cable 3 core of size 4 sqmm dia for external connection of AC & voltage stabilizer complete all as specified and directed by Engr-in-Charge. Make: Havells/ Plaza/Finolex
S&F in repairs of wiring kit for window/split type air conditioner of any capacity as per the existing model & make complete all as specified and directed by Engr-in-Charge.
S&F in repairs of copper tube 3/8" dia for AC complete all as specified and directed by Engr-in-Charge.
S&F in repairs of single pole and neutral enclosure with a two pin earth plug and socket complete with one single pole 20 Amp, 240 Volt MCB complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Copper Condenser coil unit complete suitable for 1.5/2 Ton window type AC including R22 refrigerant gas charging and welding/bracing work etc of existing model & make complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Copper Condenser coil unit complete suitable for 1.5/2 Ton split type AC outdoor unit including R22 refrigerant gas charging and welding/bracing work etc of existing model & make complete all as specified and directed by Engr-in-Charge.
Cutting & removing deteriorated sheet steel surfaces of body, chassis, body bottom portions etc, of window type air conditioners any size and capacity and reconstructing body to the existing shape and size with PGI sheet of 16 / 20 SWG, necessary welding / bracing work, including all necessary items such as nuts, bolts, washers, drilling holes etc. including applying two coats of synthetic enamel paint using spray gun over a coat of red oxide primer matching with the existing tint & shade complete all as specified and directed by Engr-in-Charge.
S&F in repairs of Cooling coil unit suitable for 1.5/2.0 Ton window type AC including R22 refrigerant gas charging and welding/bracing work etc of existing model & make complete all as specified and directed by Engr-in-Charge.
S&F in repairs of Cooling coil unit suitable for 1.5/2.0 Ton split type AC indoor unit including R22 refrigerant gas charging and welding/bracing work etc of existing model & make complete all as specified and directed by Engr-in-Charge.
S&F in replacement new hermetical sealed compressor unit suitable for 1.5 Ton capacity window / split type AC, suitable for working on 230 V 50 Hz including necessary welding / bracing work to existing refrigerant pipes, supply & charging refrigerant gas R22 of required quantity including testing on full load complete all as specified and directed by Engr-in-Charge. Make- Emerson Copeland / LG / Voltas
S&F in replacement new hermetical sealed compressor unit suitable for 2 Ton capacity window/split type AC, suitable for working on 230 V 50Hz including necessary welding/bracing work to existing refrigerant pipes, supply & charging refrigerant gas R22 of required quantity including testing on full load complete all as specified and directed by Engr-in-Charge. Make- Emerson Copeland / LG / Voltas
Supply and fixing in replacement rotary compressor sealed unit suitable for 1.5 ton split/window type AC suitable for working on 230 V 50Hz including necessary welding/bracing work to existing refrigerant pipes, supply & charging refrigerant gas R22 of required quantity including testing on full load complete all as specified and directed by Engr-in-Charge. Make- Blue Star/LG/ Voltas
Supply and fixing in replacement rotary compressor sealed unit suitable for 2 ton split/window type AC suitable for working on 230 V 50Hz including necessary welding / bracing work to existing refrigerant pipes, supply & charging refrigerant gas R22 of required quantity including testing on full load complete all as specified and directed by Engr-in-Charge. Make- Blue Star/LG/Voltas
Supply and fixing in replacement reversible cycle heating unit suitable for split / window type AC 1.5 / 2 ton capacity including necessary welding / brazing work, charging of gas and testing of split / window type AC for satisfactory working complete all as specified and directed by Engr-in-Charge.
Shifting/installation of split type 1.5/2 Ton AC complete with proper connection of outer and inner unit with gas charging if required complete all as specified and directed by Engr-in-Charge.
Dismantling the old unserviceable outdoor unit of split type AC of cap 1.5 Ton and fixing of the new outdoor unit complete with copper condenser coil, cooling coil, blower motor with PVC fan blade including fixing of new compressor & charging refrigerant gas R22 of required quantity including testing on full load complete all as specified and directed by Engr-in-Charge. Note: Unserviceable unit will be deposited to MES store
Dismantling the old unserviceable in door unit of split type AC of cap 1.5 Ton and fixing of the new in door unit complete with cooling coil, blower motor with PVC drum & electronic circuits including testing complete all as specified and directed by Engr-in-Charge. Note: Unserviceable unit will be deposited to MES store.
Dismantling the old unserviceable outdoor unit of split type AC of cap 2 Ton and fixing of the new outdoor unit complete with copper condenser coil, cooling coil, blower motor with PVC fan blade including fixing of new compressor & charging refrigerant gas R22 of required quantity including testing on full load complete all as specified and directed by Engr-in-Charge. Note: Unserviceable unit will be deposited to MES store
Dismantling the old unserviceable in door unit of split type AC of cap 2 Ton and fixing of the new indoor unit complete with cooling coil, blower motor with PVC drum & electronic circuits including testing complete all as specified and directed by Engr-in-Charge. Note: Unserviceable unit will be deposited to MES store
Stripping up refrigerator of any make & capacity dismantling and taking out unserviceable parts such as starting relay, OLP, thermostat, gas drier filter, bulb etc including fixing new parts with new nut bolts and washers etc re-assembling the refrigerator after repair and testing complete all as specified and directed by Engr-in-Charge. Note: Spare parts shall be measured and paid separately under respective items as supply only.
S&F in replacement new hermetical sealed compressor unit suitable for 170-230 Ltr capacity refrigerator suitable for working on 230 V 50Hz including necessary welding / bracing work to existing refrigerant pipes, supply & charging refrigerant gas R134a of required quantity including testing on full load complete all as specified and directed by Engr-in-Charge. Make- Godrej/LG or equivalent approved make.
S&F in replacement new hermetical sealed compressor unit suitable for 280-350 ltr capacity refrigerator suitable for working on 230 V 50Hz including necessary welding / bracing work to existing refrigerant pipes, supply & charging refrigerant gas R134a of required quantity including testing on full load complete all as specified and directed by Engr-in-Charge. Make- Godrej/LG or equivalent approved make.
S&F in repairs of starting relay assembly suitable for refrigerator of any make & capacity. Make : Godrej/Whirlpool/ LG/Annapurna
S&F in repairs of running capacitor 6 MFD 440 VAC for AC blower motor/refrigerator. Make : Havells/Amcap/Epcos
S&F in repairs of over load protector suitable for refrigerator of any make & capacity. Make : Godrej/Whirlpool/LG /Annapurna
S&F in repairs of magnetic rubber door gasket suitable for refrigerator of any make & capacity complete all as specified and directed by Engr-in-Charge.
S&F in repairs of thermostat switch suitable for refrigerator of any make & capacity. Make : Whirlpool/LG
S&F in repairs of bulb for refrigerator/deep freezer 15 Watt 220 volt screw/pin type. Make : Bajaj / Omex/Philips
S&F in repairs of gas drier filter suitable for refrigerator of any make & capacity complete all as specified and directed by Engr-in-Charge.
S&F in repairs of liquid line filter suitable for refrigerator of any make & capacity complete all as specified and directed by Engr-in-Charge.
S&F in repairs of copper tube 1/4" dia for refrigerator complete all as specified and directed by Engr-in-Charge.
S&F in repairs of evaporator fan motor for double door refrigerator of any make & capacity complete all as specified and directed by Engr-in-Charge.
S&F in repairs of bimetal thermostat for double door refrigerator of any make & capacity complete all as specified and directed by Engr-in-Charge.
S&F in repairs of temperature sensor assembly for double door refrigerator of any make & capacity complete all as specified and directed by Engr-in-Charge.
S&F in repairs of electronic power supply control PCB for double door refrigerator of any make & capacity complete all as specified and directed by Engr-in-Charge.
M&L for gas charging with R-22 / 134a refrigerant up to required quantity to refrigerator of any make and capacity including flushing of gas,oil charging, necessary welding and bracing works, checking for leakage and testing on full load complete all as specified and directed by Engr-in-Charge. Note:- No extra payment will be given to contractor to top up the gas in case of leakage from refrigerator.
M&L for applying a coat of superior quality duco paint of approved tint and shade on the external painted surfaces of refrigerators of any capacity using a spray jet gun including necessary preparation of old painted surfaces including writing of MES No and SM No complete all as specified and directed by Engr-in-Charge.
S&F in replacement of condenser coil suitable for 280-350 ltsr refrigerator of any make and capacity including charging of refrigerant gas and necessary welding / bracing work etc including testing complete on load complete all as specified and directed by Engr-in-Charge.
S&F in replacement of condenser coil suitable for 170-230 ltsr refrigerator of any make and capacity including charging of refrigerant gas and necessary welding / bracing work etc including testing complete on load complete all as specified and directed by Engr-in-Charge.
Stripping up deep freezer of any make & capacity dismantling and taking out unserviceable parts such as relay, over load protector, thermostat, gas drier filter, bulb etc including fixing new parts with new nut bolts and washers etc re-assembling the deep freezer after repair and testing complete all as specified and directed by Engr-in-Charge. Note:- Spare parts shall be measured and paid separately under respective items as supply only.
Supply only over load protector for deep freezer of any make/capacity. Make- Technomech/Classic/Annapurna.
S&F in repairs of liquid line filter suitable for deep freezer of any make & capacity complete all as specified and directed by Engr-in-Charge.
S&F in repairs of electronic timer circuit for deep freezer 200-300 ltrs capacity of any make complete all as specified and directed by Engr-in-Charge.
M&L for gas charging with R22 / 134a refrigerant up to required quantity to deep freezer of any make and capacity including flushing of gas,oil charging, necessary welding and bracing works, checking for leakage and testing on full load complete all as specified and directed by Engr-in-Charge. Note: No extra payment will be given to contractor to top up the gas in case of leakage from deep freezer.
S&F in replacement new hermetical sealed compressor unit suitable for 300 ltr capacity deep freezer suitable for working on 220-240 V 50Hz including necessary welding / bracing work to existing refrigerant pipes, supply & charging refrigerant gas R 134a of required quantity including testing on full load complete all as specified and directed by Engr-in-Charge. Make- LG /Voltas/Blue Star
Stripping up water cooler (storage type) of any make & capacity dismantling and taking out unserviceable parts such as starting relay, OLP, thermostat, capacitors, gas drier filter, push cock, floot valve, fan blade etc including fixing new parts with new nut bolts and washers etc re-assembling the water cooler after repairs and testing complete all as specified and directed by Engr-in-Charge. Note: Spare parts shall be measured and paid separately under respective items as supply only.
Taking out and opening carefully blower motor, fan blade of water cooler 40/80 ltrs & 60/120 ltrs dismantling, cutting and removing the unserviceable copper winding wire of blower motor and rewinding with super enamelled copper winding wire of existing gauge including replacement of unserviceable bushes/bearings, long nuts, bolts etc and reasembling complete all as specified and directed by Engr-in-Charge.
S&F in repairs of thermostat switch for water cooler of any make and capacity. Make : Renutol / Danfoss
S&F in repairs of Starting capacitor 40/60 MFD 250 VAC. Make : Havells/Amcap/Epcos
S&F in repairs of Starting capacitor 60/80 MFD 250 VAC. Make : Havells/Amcap/Epcos
S&F in repairs of starting relay assembly suitable for water cooler of any make/capacity. Make- Technomech/Classic/Annapurna.
S&F in repairs of over load protector for water cooler of any make/capacity. Make- Technomech/Classic/Annapurna.
S&F in repairs of CP push cock / lifting cock (water taps) suitable for 15 mm dia pipe.
S&F in repairs of blower motor 1/10 HP with fan blade including nuts, bolts and clamps etc for any make and capacity of water cooler complete all as specified and directed by Engr-in-Charge.
S&F in repairs of blower motor 1/35 HP with fan blade including nuts, bolts and clamps etc for any make and capacity of water cooler complete all as specified and directed by Engr-in-Charge.
S&F in repairs of running capacitor 10 MFD 440 VAC. Make : Usha/Amcap/Epcos
S&F in repairs of running capacitor 15 MFD 440 VAC. Make : Usha/Amcap/Epcos
S&F in repairs of PVC flexible pipe 32 mm dia for water cooler drain out pipe complete all as specified and directed by Engr-in-Charge.
S&F in repair of PVC insulated and sheathed multistranded copper conductor cable 3 core of size 2.5 Sqmm dia for external connection of water cooler, Refrigerator & voltage stabilizer complete all as specified and directed by Engr-in-Charge. Make : Havells/ Plaza/Finolex
S&F in repairs of condenser coil complete with copper tube and aluminium fins suitable for water cooler 40/80 ltrs, 60/120 ltrs & 150 ltrs capacity of any make and capacity including charging of refrigerant gas and necessary welding / bracing work, checking of leakage and testing on full load complete all as specified and directed by Engr-in-Charge.
M&L for gas charging with R22/R134a refrigerant up to required quantity of water cooler any make & capacity including flushing of gas, oil charging, including replacement of necessary capillary copper tube, necessary welding and bracing works, checking of leakage and testing on full load complete all as specified and directed by Engr-in-Charge. Note: No extra payment will be given to contractor to top up the gas in case of leakage from water cooler.
M&L for applying a coat of superior quality duco paint of approved tint and shade on the external painted surfaces of water cooler any make & capacity using a spray jet gun including necessary preparation of old painted surfaces and applying a coat of black synthetic enamel paint to all internal parts such as compressor unit, condenser fan etc, and writing of MES No and SM No complete all as specified and directed by Engr-in-Charge.
S&F in replacement new hermetical sealed compressor unit suitable for water cooler 40/80 ltrs capacity Make- Emerson Copeland / LG / Voltas, suitable for working on 230 V 50Hz including necessary welding/bracing work to existing refrigerant pipes, supply & charging refrigerant gas R-22/ R134a of required quantity including testing on full load complete all as specified and directed by Engr-in-Charge.
S&F in replacement new hermetical sealed compressor unit suitable for water cooler 60/120 ltrs capacity suitable for working on 230 V 50Hz including necessary welding/bracing work to existing refrigerant pipes, supply & charging refrigerant gas R22/R134a of required quantity including testing on full load complete all as specified and directed by Engr-in-Charge. Make- Emerson Copeland / LG / Voltas
Repairs to water cooler body, base frame with legs, door unit, storage tank, FHP motor base etc of any capcity & make by cutting worn out / deteriorated portions of sheet steel and reconstructing body including providing ventilation grooves, hinges where required and steel storage tank to the existing shape and size using PGI sheet of 16 / 20 SWG as per the existing, necessary welding / bracing work to match with the existing surface, including all necessary items such as nuts, bolts, washers, drilling holes etc. and applying two coats of synthetic enamel paint on the affected previously painted area using spray gun over a coat of red oxide primer matching with the existing tint & shade complete all as specified and directed by Engr-in-Charge.
Dismantling the old unserviceable desert cooler and fixing of the new desert cooler cabinet locally fabricated with three side panels front, top and tank including vertical mention made out 22 SWG PGI sheet of size not more than 81.5 x 80.5 x 97.5 Cm with double diversion grills and grill box suitable for 18” sweep fan and making holes with fixing arrangement including 4 way PVC distributor, PVC pipe 1 to 2 Mtr for spray water, wood wool pads, electrical wiring for fan & pump, controlled separately with 5 amp Piano type switch and indicator etc complete all as specified and directed by Engr-in-Charge.
S&F in repairs of wood wool pad 15mm thick for sides and back shutters of coolers made out of chicken wire mesh filled with fine quality wood wool and stitched with GI wire for desert cooler of any make & size complete all as specified and directed by Engr-in-Charge.
S&F in repairs of wool cool for evaporative air coolers complete all as specified and directed by Engr-in-Charge.
S&F in repairs of watter lifting pump for 4 feet lift suitable for desert coolers of any size / capacity complete all as specified and directed by Engr-in-Charge. Make : Summercool/Nelco
S&F in repairs of water lifting pump for 6 feet lift suitable for desert coolers of any size / capacity complete all as specified and directed by Engr-in-Charge. Make : Summercool/Nelco
S&F in repairs of capacitor 4 MFD 440 VAC. Make : Havells/Amcap/Epcos
S&F in repairs of PVC flexible pipe 15 mm dia for desert cooler complete all as specified and directed by Engr-in-Charge.
Taking out and opening carefully the exhaust fan / kit fan motor of any make / model, cutting and removing old short circuited stator winding complete and rewinding with super enamelled copper winding wire of existing gauge including replacement of unserviceable GM bush / bearing, long nuts bolts etc with new one and reassembling complete all as specified and directed by Engr-in-Charge.
S&F in repairs of kit fan motor in replacement for desert cooler with fan blade complete all as specified and directed by Engr-in-Charge. Make : Summercool/Nelco/CG
S&F in repairs of Exhaust fan motor with 18" size blade in replacement for desert cooler complete all as specified and directed by Engr-in-Charge. Make : Summercool/Nelco
S&F in repairs of PVC insulated and sheathed multistranded copper conductor cable 3 core of size 1.5 Sqmm dia for external connection of desert cooler & voltage stabilizer complete all as specified and directed by Engr-in-Charge. Make : Havells/ Plaza/Finolex
M&L for painting of desert cooler’s external body and fan with one coat of synthetic enamel grey paint & internal body with synthetic enamel black paint complete after proper dusting, cleaning and scrapping old painted surfaces complete all as specified and directed by Engr-in-Charge.
S&F in replacement of front grill for desert cooler of any make any type made of PGI sheet of 22 gauge complete all as specified and directed by Engr-in-Charge.
S&F in replacement of water tank of desert cooler of size 750x750x170mm (Approx) made from 20 gauge PGI sheet including necessary holes & drain plug complete all as specified and directed by Engr-in-Charge.
S&F in replacement of water tank of desert cooler of size 800x800x260mm (Approx) made from 22 gauge PGI sheet as per site requirement including necessary holes & drain plug complete all as specified and directed by Engr-in-Charge.
S&F in replacement of desert cooler fabricated made out of GI sheet 18 SWG for tank and 20 SWG for body with 3 Nos of moveable shutters with iron grill including accessories like as 450mm copper wound fan motor, copper wound submersible pump, wiring, switches etc complete electric driven (single phase), having nominal air flow capacity 5000 Cum per hours including angle iron stand made of 25mmx25mmx5mm of suitable height for desert cooler with duly painted one coat of anti corrosion red oxide primer and two coat of synthetic enameled duco paint (Make: Berger) complete all as specified and directed by Engr-in-charge. Make of Motor: Khaitan/ CG /Bajaj
Repair to automatic voltage stabilizer 5/ 4/ 3 KVA single phase 230 volts 50 Hz of any make by opening the stabilizer and replacement of the defective parts such as main transformer, auto transformer, indicators etc, and reassembling and testing the stabilizer on full load for satisfactory performance complete all as specified and directed by Engr-in-Charge.
M&L for cutting and removing existing short circuited windings of 5 / 4 KVA main transformer of voltage stabilizers 160 volts to 260 volts or 140 volts to 270 volts AC single phase and re-winding the same with super enamelled copper winding wire of existing gauge complete all as specified and directed by Engr-in-Charge.
M&L for cutting and removing existing short circuited windings of 3 / 2 KVA main transformer of voltage stabilizers 160 volts to 260 volts or 140 volts to 270 volts AC single phase and re-winding the same with super enamelled copper winding wire of existing gauge complete all as specified and directed by Engr-in-Charge.
S&F in repairs of auto transformer 6/12 volts output and 220 volt input suitable for 5 / 4/ 3 KVA voltage stabilizer complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Voltage Stabilizer for automatic operation single phase 230 volts 50 C/s AC 160 volt to 250 volts + 2.5 % of capacity 4 KVA electronic digital type wall mounted type complete all as specified and directed by Engr-in-charge. Make: Volina/Vinitech/V-Guard. Note: Unserviceable Stabilizer will be deposited to MES store.
S&F in replacement of Voltage Stabilizer for automatic operation single phase 230 volts 50 C/s AC 160 volt to 250 volts + 2.5 % of capacity 5 KVA electronic digital type wall mounted type complete all as specified and directed by Engr-in-charge. Make: Volina/Vinitech/V-Guard. Note: Unserviceable Stabilizer will be deposited to MES store.
Supply and install in replacement of bottled water dispenser, having option of dispensing hot and cold water with coiling capacity 3 ltrs/hr and tank capacity of 3.4 ltrs, heating capacity 6 ltrs/hr and tank capacity 1.6 ltrs, working in R-134a refrigerant complete all as specified and directed by Engr-in-Charge. Make: Voltas/Blue Star/Usha Note: Unserviceable unit will be deposited to MES store.
S&F in repairs of plug top 3 pin 6 Amp for refrigerator, desert cooler & stabilizer complete all as specified and directed by Engr-in-Charge.
S&F in repairs of plug top 3 pin 16 Amp for AC, water cooler & stabilizer complete all as specified and directed by Engr-in-Charge.
M/s Prakash Enterprises
M/S PARKASH ENTERPRISES
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .