Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹67.8 LAccepted-AOC FLAT NO 151 BLOCK NO 1 DIAMOND SQUARE CGHS LTD PLOT NO 13A SECTOR 6 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | L1 | Accepted-AOC AOC | |
| 2 | L2₹72.4 L+₹1.5 L (2.08%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | L2 | Rejected-Finance Not being lowest tender | |
| 3 | L3₹72.9 L+₹1.9 L (2.66%)Rejected-Finance | L3 | Rejected-Finance Not being lowest tender | |
| 4 | L4₹73.4 L+₹2.4 L (3.40%)Rejected-Finance | L4 | Rejected-Finance Not being lowest tender | |
| 5 | L5₹74 L+₹3.0 L (4.28%)Rejected-Finance WZ 1000 NANGAL RAYA PANKHA ROAD SOUTH WEST DELHI DELHI 110046 | DELHI | SOUTH WEST DELHI | DELHI | 110046 | L5 | Rejected-Finance Not being lowest tender |
| Sl No | Description | Qty | Unit | mayur enterprises L5 | MV Engineers And Contractors L7 | M/s JAIMAA ASSOCIATES L3 | Commercial Traders L2 | Leo Air and Power Solution pvt Ltd. L8 | Vijay Electricals L6 | Rajindera Enterprises L4 | BRIJ MOHAN LAL AND CO. L1 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft loose soil for laying / taking up/ taking down of cables and getting out and levelling of bottom surface to required level all as specified and directed. | 1,225 | Cum | 100 ₹1,22,500 | 99 ₹1,21,275 | 180 ₹2,20,500 | 85 ₹1,04,125 Lowest | 170 ₹2,08,250 | 89 ₹1,09,025 | 100 ₹1,22,500 | 109 ₹1,33,525 |
| 2.00 | Returning filling in,. including spreading, levelling, watering and well ramming soil in layers not exceeding 25 cm thick complete all as specified and directed. | 944 | Cum | 20 ₹18,880 | 26 ₹24,544 | 40 ₹37,760 | 15 ₹14,160 Lowest | 115 ₹1,08,560 | 29 ₹27,376 | 30 ₹28,320 | 50 ₹47,200 |
| 3.00 | Removing excavated material (ie soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point all as specified and directed. | 281 | Cum | 20 ₹5,620 Lowest | 26 ₹7,306 | 40 ₹11,240 | 20 ₹5,620 Lowest | 120 ₹33,720 | 29 ₹8,149 | 30 ₹8,430 | 40 ₹11,240 |
| 4.00 | Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified. | 245 | Cum | 350 ₹85,750 | 300 ₹73,500 Lowest | 300 ₹73,500 Lowest | 400 ₹98,000 | 600 ₹1,47,000 | 350 ₹85,750 | 300 ₹73,500 Lowest | 369 ₹90,405 |
| 5.00 | Supply & laying non-reinforced precast concrete cable (PCC) cover class HV type 1 with peak size 300 mm x 180mm x 40mm in trenches for protection to under ground cable complete all as specified. | 12,000 | Each | 35 ₹4,20,000 | 22 ₹2,64,000 | 19 ₹2,28,000 | 22 ₹2,64,000 | 29 ₹3,48,000 | 18 ₹2,16,000 Lowest | 20 ₹2,40,000 | 19 ₹2,28,000 |
| 6.00 | All as per item No 5 here-in-before but using old cable covers retrieved from excavation complete all as specified and directed. | 4,806 | Each | 1 ₹4,806 | 1 ₹4,806 | 1 ₹4,806 | 0.2 ₹961.2 Lowest | 1 ₹4,806 | 5 ₹24,030 | 1 ₹4,806 | 1 ₹4,806 |
| 7.00 | Supplying, laying, jointing testing and connecting XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 300 sqmm 3 core with multistranded aluminum conductors, 11 KV grade, IS 7098 marked, suitable for HT 11 KV(E) system, laid in trenches / ducts / encased in GI or HDPE pipe / fixed to pole, including jointing & testing complete all as specified and directed.(Location:-Shekhawati 33/11 KV Grid to Chitral line Sub station)
Note :- Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately under respective items of schedule. | 3,500 | RM | 1,792 ₹62,72,000 | 1,951 ₹68,28,500 | 1,749 ₹61,21,500 | 1,795 ₹62,82,500 | 1,805 ₹63,17,500 | 1,888 ₹66,08,000 | 1,850 ₹64,75,000 | 1,744 ₹61,04,000 Lowest |
| 8.00 | S&F for cable route indicator made of RCC (Nominal Mix) type B0 1:2:4 (12.5mm graded stone aggregate) with 8mm TMT Bar 150mm c/c of size 1m height X 60cm wide X 10cm thick tapered on top, visible above ground, duly painted with synthetic enamel paint of yellow colour base and letters with black paint. The description for writing for HT cable 33 /11KV as directed by Engr-in-charge complete all as specified and directed.
Note : Rate for PCC 1:3:6 for foundation (min size 0.8mx0.3mx0.3m) of aggregate size 20mm including necessary excavation & earthwork for cable route indicator deemed to be included in the item. | 40 | Each | 350 ₹14,000 Lowest | 559 ₹22,360 | 900 ₹36,000 | 850 ₹34,000 | 1,306 ₹52,240 | 500 ₹20,000 | 500 ₹20,000 | 410 ₹16,400 |
| 9.00 | M&L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine with HDPE pipe of 150 mm dia suitable for 0.6 mpa working pressure complete all as specified and directed. | 250 | RM | 800 ₹2,00,000 | 600 ₹1,50,000 | 1,200 ₹3,00,000 | 500 ₹1,25,000 Lowest | 568 ₹1,42,000 | 600 ₹1,50,000 | 600 ₹1,50,000 | 900 ₹2,25,000 |
| 10.00 | M&L for Boring of hole under road/pavement/hard standing or any other situation by mannual means and suitable for passing of GI pipe 100 mm bore and making good both ends all specified and directed | 50 | RM | 500 ₹25,000 | 400 ₹20,000 | 500 ₹25,000 | 280 ₹14,000 | 379 ₹18,950 | 500 ₹25,000 | 600 ₹30,000 | 270 ₹13,500 Lowest |
Tender Value
₹1.0 Cr
EMD Value
₹1.8 L
Closing Date
27 Jun 2025, 6:00 pmClosed
HQ CWE (U) Delhi Cantt-110010
HQ CWE (U) Delhi Cantt-110010
SPECIAL REPAIR/REPLACEMENT OF HT CABLE 11000 VOLTS FROM 33/11 KV SHEKHAWATI GRID TO MRS CHITRAL LINE UNDER GE(U) ELECT SUPPLY DELHI CANTT-10
2025_MES_711668_1
CWE (U)/D-08/2025-26
Open Tender
Civil Works
Works
180 days
HQ CWE (U) Delhi Cantt
Please refer Tender Documents
9 documents required · 9 mandatory
₹1,000
GE (U) ELECT SUPPLY
₹1.8 L
Yes
12 Aug 2025
31 May 2025
4 Jul 2025
31 May 2025
27 Jun 2025
22 Jun 2025
Amount
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft loose soil for laying / taking up/ taking down of cables and getting out and levelling of bottom surface to required level all as specified and directed.
Returning filling in,. including spreading, levelling, watering and well ramming soil in layers not exceeding 25 cm thick complete all as specified and directed.
Removing excavated material (ie soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point all as specified and directed.
Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified.
Supply & laying non-reinforced precast concrete cable (PCC) cover class HV type 1 with peak size 300 mm x 180mm x 40mm in trenches for protection to under ground cable complete all as specified.
All as per item No 5 here-in-before but using old cable covers retrieved from excavation complete all as specified and directed.
Supplying, laying, jointing testing and connecting XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 300 sqmm 3 core with multistranded aluminum conductors, 11 KV grade, IS 7098 marked, suitable for HT 11 KV(E) system, laid in trenches / ducts / encased in GI or HDPE pipe / fixed to pole, including jointing & testing complete all as specified and directed.(Location:-Shekhawati 33/11 KV Grid to Chitral line Sub station) Note :- Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately under respective items of schedule.
S&F for cable route indicator made of RCC (Nominal Mix) type B0 1:2:4 (12.5mm graded stone aggregate) with 8mm TMT Bar 150mm c/c of size 1m height X 60cm wide X 10cm thick tapered on top, visible above ground, duly painted with synthetic enamel paint of yellow colour base and letters with black paint. The description for writing for HT cable 33 /11KV as directed by Engr-in-charge complete all as specified and directed. Note : Rate for PCC 1:3:6 for foundation (min size 0.8mx0.3mx0.3m) of aggregate size 20mm including necessary excavation & earthwork for cable route indicator deemed to be included in the item.
M&L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine with HDPE pipe of 150 mm dia suitable for 0.6 mpa working pressure complete all as specified and directed.
M&L for Boring of hole under road/pavement/hard standing or any other situation by mannual means and suitable for passing of GI pipe 100 mm bore and making good both ends all specified and directed
Supply and laying GI pipe light grade in replacement as cable protection laid on Floor/Drain Crossing/ Nalla etc of size 100 mm dia complete all as specified and directed.
M&L for HDPE pipe of suitable for 4 kgf/cm2 working pressure with all fitting , laid in Road crossing for protection of cable in road /drain crossing of size 150mm complete all as specified and directed.
S&F Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm to 300 sqmm complete all as specified and directed.
S&F Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm to 300 sqmm complete all as specified and directed.
M&L for Earthing complete with galvanized steel earth plate electrode of size 60cmx60cmx6 mm thick, buried directly in ground (earth pit not less than 2.25 m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanized iron strip 32x6mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel as shown in electrical plate No 3 of SSR Part I, connected to earth test point and the equipment on the other side including testing and commissioning complete all as specified and directed. Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 40 mm bore GI pipe medium grade etc. (b) The quoted rates shall also deemed to include the cost of earth test point and earth strip/GI lead wire and protection pipe upto 7.5 meter beyond the earth plates electrode.
Commercial Traders (BID ID -3338258)
M/s JAIMAA ASSOCIATES (BID ID -3338168)
Rajindera Enterprises (BID ID -3339214)
mayur enterprises (BID ID -3336702)
Vijay Electricals (BID ID -3338986)
MV Engineers And Contractors (BID ID -3337893)
Leo Air and Power Solution pvt Ltd. (BID ID -3338971)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .