Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.0 LAccepted-AOC H NO 200 GIRJA NAGAR 37 BN P A C LINE KANPUR 208015 | KANPUR | KANPUR | UTTAR PRADESH | 208015 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹27.3 L+₹1,127 (0.04%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹28.2 L+₹87,920 (3.22%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹28.6 L+₹1.3 L (4.76%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹31.0 L
EMD Value
₹62,080
Closing Date
30 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(AF) B/R Chakeri Kanpur
GE(AF) B/R Chakeri Kanpur-208008
EXTENSION OF DLM HALL AT M-53 OH LINE AT 4 BRD AT AFS CHAKERI KANPUR
2024_MES_670447_1
GE (AF) BR/CHK/T-27 OF 2024-25 8946/E8
Open Tender
Civil Works
Item Rate
180 days
GE(AF) B/R Chakeri Kanpur
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE(AF) B/R Chakeri Kanpur
₹62,080
Yes
7 Dec 2024
2 Sept 2024
7 Oct 2024
2 Sept 2024
30 Sept 2024
16 Sept 2024
Amount
Dismantling of wall and ceiling boards any type (fibre, pulp , insulation etc.) or insulation boards/ slabs/ blankets any thickness including cover fillets complete all as specified and as directed.
Providing & fixing false ceiling at all heights with GRG (Glass Fibr Reinforced Gypsum) false ceiling tiles ofSize 595 x 595 mm of approved texturedesign and patterns having moisture content less than 2%, humidity resistance8225:1987, Noncombustible as per BS4 76 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of mainT runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of s1ze 600x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1 OOOmm length and Lshape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-inCharge
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises ,complete all as specified and directed.
M&L Non - skid industrial full body vitrified joint free tiles 15 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. over and including 15 mm thick screed bed of CM (1:6) set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
S&F powder coated aluminium (minimum thickness of powder coating 50 micron) work for door with chowkhat /frame made with aluminium section with size 100x44x2mm thick and shutter of vertical style with section 84x44x2mm thick and top /middle / bottom rails of shutter made with 112x44x2mm thick over and including 5mm thick tinted glass panes , including necessary fixing arrangment ,joining cleats, glazing clips, rubber beading ,floor door spring, tower bolts 200mm long ,mortice lock 300 mm ,4 lever, rounded handles etc fixed to shutters complete all as specified and directed by engr in charge.
Taking down wooden chowkats or frames exc 1.5 sqm but not exceeding 4.0 sqm each with shutters (without taking off shutters from the frame) complete all as specified and directed.
Taking down wooden chowkats or frames n exc 1.5 with shutters (without taking off shutters from the frame), complete all as specified and directed directed.
M & L for powder coated aluminium (minimum thickness of powder coating 50 micron) work for two track slidindg window with frame of section No 20829 & 20830 of Jindal or equivalent of make specified. The window shutters shall be of section No 20736 & 20738 of Jindal or equivalent of make specified including supply and fixing 5 mm thick tinted glass, glazing clips, rubber beading alongwith roller, locking arrangement etc as required complete all as specified and as directed.
S & F providing and fixing powder coated aluminium (minimum thickness of powder coating 50 micron) work for partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete all as specified and directed. Note : Glazing item like glass, particle board, Aluminium Composite panel board will be measured and paid separately under item 11. 12 & 13.
S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples all as specified and directed.
M & L for 12 mm thick prelaminated particle board, exterior grade prelaminated both side with decorative choice lamination, fixed with screws to timber frame work in cup board shutters, partitions, shelves and similar work complete all as specified and directed
M & L for 4 mm thick Aluminium composite panel board, exterior grade prelaminated both side with decorative choice lamination, fixed with screws to aluminium frame work in cup board shutters, partitions, shelves and similar work complete all as specified and directed
Taking down cement plaster of any description on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc.complete all as specified and directed.
M&L for rendering 15mm thick on other than fair faces of brick work or concrete surface in cement mortar 1:4 finished even and smooth complete all as specified and as directed.
M & L for preparing new plastered surface and applying two coats of weather proof exterior emulsion paint over and incl 1 mm thick wall care putty over a coat of primer complete all as specified and as directed.
M&L for rendering 15mm thick on fair faces of brick work or concrete surface in cement mortar 1:6 finished even and smooth complete all as specified and as directed.
M & L for preparation of new undecorated surfaces of walls and applying two coat of Oil Bound Distemper over and incl a coat of primer and 1mm thick wall care putty complete all as specified and directed.
S&F in repair vitreous china wash down water closet one piece with integrated cistern, seat cover and twin flush fitting complete all as specified and as directed .
S&F Vitreous Cliina wash basin, angle back, size 600x480mm white, excluding taps, waste, chain and plug and porcelain stopper but including brackets complete all as specified and directed.
Cutting existing 15 mm dia steel tubing for alterations or additions (Each cut measured if necessarily done in position without taking down complete all as specified and directed.
S&F 15 mm dia Tubes, ' Medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F 15mm bore pillar taps cast copper alloy fancy type chromium plated screwed down high pressure with or without lattered HOT or COLD with long screwed shank and fly nuts screwed for iron pipes complete all as specified and directed.
S&F in PVC connections 15mm size with PTMT nuts of length 600 mm, complete all as specified and as directed.
S&F in repairs 15mm bore angle valves, cast copper alloy fancy type chromium plated with flange complete all as specified and directed.
M&L preparation of old decorated plastered surfaces or un-plastered surfaces of wall and applying one coat of oil bound distemper complete all as specified and directed .
M&L preparation of old surface of wall or ceiling and application of one coat of exterior weather emulsion paint complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Excavating in post holes in soft soil (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed.
S&F Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated grade Fe-410 complte all as specified and directed
M&L Preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
M&L Cement concrete in foundations, filling and mass concrete type C-2 (1:3:6) 20 mm graded agregate complete all as specified and directed
S&F Door closer hydraulically regulated,aluminium die casted designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed.
Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and directed
M&L Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets complete all as specified and directed.
Taking down old unserviceable/deteriorated batten/MS conduit point wiring from existing place i.e. light, fan, socket or power points complete with all unserviceable fittings such as switches, sockets, ceiling rose, pendants, Holders, etc and making good all disturbed surface to wall, floor etc by means of cement mortar (1 : 3) or plaster of Peris and to match / finish new surface as the existing surface either by using same colour distemper, PuttY or white / colour wash all as required and directed by Engineer-in-Charge.
M & L for concealed point wiring on wall and surface on ceiling / roof with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid ivory PVC conduit medium grade ISI marked not less than 19 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and modular white cover plate with frame for fixing of switches / sockets, fan regulators, wall mounting fittings, door bell & bulkhead etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of peris/ Putti or distemper / colour wash with same existing colour surfaces all as specified and directed for one light/call bell point controlled by one switch.
All as per item No. 37 above but One ceiling fan/exhaust fan controlled by one switch
All as per item No. 37 above but One 3 pin socket outlet, 5 Amps independent board
All as per item No. 37 above but One 3 pin 5 amps socket outlet on the same board with other switches
All as per item No 37 here in before but for one socket out let 2in1 5 and 15 Amps with 2.5 Sqmm PVC insulated copper conductor and provn of 2.5 sqmm PVC insulated single core copper cable green in colour as earth continuity conductor complete all as specified and directed.
S&F switch flush type single pole one way 5 Amps, 240 volts, white finish ISI Marked complete all as specified and directed.
S&F switch flush type 15 Amps, 240 Volts single pole white finish complete ISI Marked complete all as specified and directed.
S&F socket outlet 5 pin, 5 Amps flush type white finish complete conforming/ ISI Marked complete all as specified and directed.
S&F socket outlet 2 in 1, 3 pin, 5/15 A, flush type universal, 240 V white finish complete conforming/ ISI Marked complete all as specified and directed.
M & L modular switch flush type single pole one way 5 Amps, 240 volts, white finish complete all as specified and directed.
M & L, modular switch flush type 15 Amps, 240 Volts single pole white finish complete all as specified and directed.
M&L, modular socket outlet 5 pin, 5 Amps flush type white finish complete all as specified and directed.
S&F, mosular socket outlet 2 in 1, 3 pin, 5/15 A, flush type universal, 240 V white finish complete all as specified and directed.
S&F in replacement ceiling rose surface bakelite 65 x 20 mm three terminal conforming ISI marked complete all as specified and directed.
S&F, in replacement, modular electronic , rotary, 5 speed step type regulator,2 module white finish complete all as specified and directed.
M&L for Modular cover plate with frame as per site requirement for 3 module complete all as specified and directed.
All as per item No 52 above but, 6 module complete all as specified and directed.
All as per item No 52 above but, 8 module complete all as specified and directed.
M&L For Modular metal flush box 3 module complete all as specified and directed.
All as per item No 55 above but, 6 module complete all as specified and directed.
All as per item No 55 above but, 8 module complete all as specified and directed.
S&F in replacement double door metallic sheet metal enclosure for DB when MCBs to be used TPNL, 4 ways, 415Volts (horizontal type) with 200 Amps rated bus bar suitable for TPN MCB/ 4 pole Isolator fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs for cables/wires complete all as directed.
S&F sheet metal enclosure TPN MCCB DB 4 Way, 415 volt (vertical type) with bus bar double door type IP 43 -IK 09 for DB when MCBs and MCCB 160 Amp (as incomer) to be used fixed properly on/inconcealed position and to provide required sizes of flexible conduit at any open surface near DBs for cables/wires complete all as specified and directed.
S&F sheet metal enclosure TPN MCCB DB 8 Way, 415 volt (vertical type) with 250 A bus bar double door type IP 43 -IK 09 for DB when MCBs and MCCB upto 160Amp (as incomer) to be used fixed properly on/in concealed position and to provide required sizes of flexible conduit at any open surface near DBs for cables/wires complete all as specified and directed.
S&F, in replacement, double door metallic sheet metal enclosure for DB when MCBs to be used SPN 8 ways, 240 V with 200Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires all as directed.
S&F in replacement testing and commissioning of MCB SP 240 volt 6 Amp to 32 amp 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and directed.
All as per item No. 62 above, but SP 40-63 Amps complete all as specified and directed.
All as per item No. 62 above, but SPN 40-63 Amps complete all as specified and directed.
All as per item No. 62 above, but TP 40-63 A 415V complete all as specified and directed.
All as per item No. 62 above, but TPN 40-63 A 415V complete all as specified and directed.
S&F in replacement MCCB 125 Amps, 4 Pole, 415V, 36 KA complete all as specified and directed.
S&F in replacement MCCB 160 Amps, 4 Pole, 415V, 36 KA complete all as specified and directed.
S&F in replacement sheet metal enclosure , 20A single pole and neutral with a two pin and earth plug and socket complete in metal clad board with one single pole MCB 20 Amp fixed properly on in concealed position all as directed by Engineer-in-Charge.
Supply ,laying and testing cable XLPE Insulated,screened,PVC bedded,galvanized steel strip power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sqmm 4 core complete all as specified and directed.
M&L sub main wiring with two single core PVC-FRLSH insulated unsheathed multi stranded copper conductor cable of size 6 sqmm drawn in PVC conduit with single core 6 Sqmm PVC-FRLSH insulated unsheathed multi stranded copper conductor as a continuous earth wire complete all fixing accessories such as coupler lock, nuts, pipe hooks etc fixed properly complete all as specified and directed. Note : Two single core cable and one single core of earth copper conductor will be measured and paid as one unit length (ii) Cutting chases will be measured and paid seperately
M&L sub main wiring with two single core PVC-FRLSH insulated unsheathed multi stranded copper conductor cable of size 4 sqmm drawn in PVC conduit with single core 4 Sqmm PVC-FRLSH insulated unsheathed multi stranded copper conductor as a continuous earth wire complete all fixing accessories such as coupler lock, nuts, pipe hooks etc fixed properly complete all as specified and directed. Note : Two single core cable and one single core of earth copper conductor will be measured and paid as one unit length (ii) Cutting chases will be measured and paid seperately
M&L sub main wiring with two single core PVC-FRLSH insulated unsheathed multi stranded copper conductor cable of size 2.5 sqmm drawn in PVC conduit with single core 2.5 Sqmm PVC-FRLSH insulated unsheathed multi stranded copper conductor as a continuous earth wire complete all fixing accessories such as coupler lock, nuts, pipe hooks etc fixed properly complete all as specified and directed. Note : Two single core cable and one single core of earth copper conductor will be measured and paid as one unit length (ii) Cutting chases will be measured and paid seperately
Cutting chases in brick walls, pinning in at the depth of 30 mm, making good to facings where required and pointing in cement mortar 1:3 cutting chases for concealed conduit wiring,submain wiring etc and making good and palstering the surface with cement or plaster of peris and matching with same colour scheme, cutting exceeding 10cm but not exceeding 10 cm girth complete.
M & L energy saving LED 4ft Batten 20 Watt with a nominal system lumen output of 2500 lumens and a minimum system efficacy of 110 lm/W with fixing arrangements and electrical connection three core copper cable from ceiling rose to light fitting and removing UNSV complete all as specified and directed.
M & L in replacement complete for recess mounting LED Panel 600x600 mm fittings made of CRCA powder coated finish LED used shall be SMD type and fixture should have minimum efficiency at system level (Not chip level) 100lm/watt, life of fixture 50000 burning hours @ L70% Lumen maintenance CCT UP TO 6500,CRI MORE THEN 80,pf 0.95 and an operating voltage 140 Volt to 270 volt complete all as specified and directed.
M&L for earthing complete with M.S. galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below normal GL) with top edge of the earth plate not less than 1.5M below normal GL, earth plate souroundally filled charcoal and common salt in alternate layer (min 10 Kg charcoal & 10 Kg salt), connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts & washers of GI or steel with and including excavation, PCC (1:3:6) type C-1 (using 20mm graded stone agg) as in chamber with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 8 mm dia bar, 3 Nos. both way, 15 mm dia light grade GI protection pipe, funnel with wire mesh,watering pipe of size 20 mm dia mediam grade, lugs etc. all as shown in electrical plate No. 3 of SSR Pt-I, 2009 complete all as specified and directed. all as specified and directed. Note :- Main earth lead upto 7.5 mtr shall be deemed to be included in unit rate. Beyond above earth lead shall be measured and paid seperetley.
M&L for earth continuity conductor or main earthing lead 4 mm dia GI or steel wire fixed to wall on batten or recessed or buried in ground or drawn in conduit/pipe complete all as specified and directed.
Supply, installation of perforated GI cable tray 2mm thick, 150 mm wide and 100mm height inclduing laying of eixsting LT cable of any size and any capacity with fixing accessories complete all as directed by Engr-in-Charge.
M & L for flameproof concealed point wiring on wall and surface wiring on ceiling / roof /hanger with necessary fixing arrangements with stranded PVC-FRLS insulated and unsheathed copper stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including 16 gauge stove enameled ERW rigid steel conduit (metallic) not less than 19 mm dia with all MS conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including PVC-FRLS insulated and unsheathed copper stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of peris/ Putti or distemper / colour wash with same existing colour surfaces for one light, fan point controlled by one switch complete all as specified and directed. Note : Junction boxes shall be measured separately
All as per item No 80 here-in-before but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead.
S&F in repair Flame proof - weather proof switch socket & plug combined 16 A, 250 V(2P+Earth) with cable termination in LM 6 aluminium alloy housing including taking down old unserviceable complete all as specified and directed.
S&F in repair Flame proof weather proof switch rotary type with cable termination in LM 6 aluminium alloy housing 16 Amp, 240 volts complete including taking down old unserviceable complete all as specified and directed.
S&F in repair flame proof weather proof metallic hose conduit 3/4 " dia 300mm long including taking down old unserviceable complete all as specified and directed.
All as per item No 84.00 above but 500mm long.
S&F in repair flame proof weather proof threaded type junction box LM 6 aluminium alloy 4 way complete including taking down old unserviceable complete all as specified and directed.
All as per Item No 86 above but 2 way
S&F in replacement Flame proof weather proof LED luminaire 2 X16/20W, epoxy finish with LM 6 aluminium housing , heat resistant borosilicate tubular glass held in two aluminium cups with inbuilt DRIVER accessories & LED tube light complete all as specified and directed.
S&F in replacement Flame proof weather proof LED Flood light of capacity 100 watt epoxy finish with LM 6 aluminium housing , heat resistant borosilicate tubular glass held in two aluminium cups with inbuilt DRIVER accessories complete all as specified and directed. Make : Sudhir/ Shyaam/ Surya Note:- Rate of any minor T&P like nut bolt etc for fitting of new LED light at existing location are deemed to be included in the quoted rates.
M&L sub main wiring with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 2.5 sqmm drawn in Steel Conduit with single core 2.5 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete all fixing accessories such as coupler lock, nuts, pipe hooks etc fixed properly complete all as specified and directed. Note : Two single core cable and one single core of earth copper conductor, along with steel conduit will be measured and paid as one unit length (ii) Cutting chases if required will be measured and paid seperately
Supply and fix flame proof exhaust fan of size 450 mm sweep, 240 V 50 Hz complete all as specified and directed
Supply and fix flame proof wall mounting fan 450 mm sweep, 3 blade 230 V, 1440 RPM IP 55 complete all as specified and directed
Supply, installation, testing and comissioning of wall split units AC, indoor & outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality, energy efficient 5 star rated, of capacity 1.5 Ton, all as specified and directed by Engr-in-charge
Supply, installation, testing & comissioning of copper wound voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 90 V to 300 V with output voltage stabilized at 230 V with accuracy of (+/-) 2.5% and of capacity 4.0 KVA, all as specified and directed b y Engr-in-charge
S & F copper tubing of suitable size for 1.5 ton split AC unit complete with jointing the copper tubing with the existing tubing of split AC complete all as specified and directed by Engr-in-charge. Note :- Rate quoted deemed to be inclusive of fixing of required insulating material over copper tubing complete.
JEEWAN BUILDERS AND ENGINEERS (BID ID -3108861)
M/S SDS Construction Co. (BID ID -3116575)
J.B.ENTERPRISES (BID ID -3106689)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .