| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹75.9 LAccepted-AOC 11 26 BHAGWANPURA KISHANGARH CHANDIGARH | ₹75.9 L | L1 | Accepted-AOC accepted |
| 2 | L2₹77.0 LRejected-AOC 315 INDUSTRIAL AREA II PANCHKULA 134113 | PANCHKULA | HARYANA | 134113 | ₹77.0 L | L2 | Rejected-AOC rejected |
| 3 | L3₹77.3 LRejected-AOC 2ND FLOOR PLOT NO 338 UDHYOG VIHAR PHASE IV GURUGRAM 122015 HARYANA | GURUGRAM | HARYANA | 122015 | ₹77.3 L | L3 | Rejected-AOC rejected |
| 4 | Rejected-Technical 209 210 AGGARWAL TOWER PLOT NO 2 SECTOR 5 ROHINI NORTH WEST DELHI DELHI 110085 | NORTH WEST | DELHI | 110085 | - | - | Rejected-Technical rejected |
| 5 | Rejected-Technical TAILOR MARKET MAIN BAZAAR MANDI ADAMPUR 125052 | HISAR | HARYANA | 125052 | - | - | Rejected-Technical rejected |
| Sl No | Description | Qty | Unit | Insat Techno Services L2 | Netromics Engineering Solutions Private Limited L3 | AVNET Solutions L1 |
|---|---|---|---|---|---|---|
| 1.00HSR Items | ||||||
| 1.01 | [23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. [Through Rate] | 8,500 | P.Metre | 65 ₹5.5 L | 48 ₹4.1 L | 68 ₹5.8 L |
| 2.00NS Items | ||||||
| 2.01 | Supply, Installation, Testing and Commissioning of Micro processor based 2 wire fault tolerant, networkable type Fire Alarm / Detection Control Panel (having Detector nos 912. of required loops to suit minimum 20% extra over the nos. of fire detectors. The panel shall be able to give location of all fire / fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON/OFF respective control module when ever any alarm is triggered. The panel shall have rectifier, loop cards, minimum 160 characters LCD unit/ 5.7’’TFT to indicate Fire / Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects. The Panel Shall be sheet Steel power coated, sealed to IP30. The Panel shall have 20 Zones with individual LED Indicators, expandable to 80 LED Indicators. The Panel shall have 2 Serial Ports. The panel shall have a built in power supply, battery charger maintenance free battery capable of running for a minimum 24 hours operation complete as required. The panel should also have IP30 or better protection. And conforming to BS5839 standards and Duly Approved by EN 54/UL/VDS as per specifications complete in all respect up to the entire satisfaction of Engineer-in – charge of work.
Make: Morley ZX5SE,Bosch Avenar 2000, Siemens Cerberus EN. | 2 | Each | 3,85,900 ₹7.7 L | 4,22,000 ₹8.4 L | 3,76,000 ₹7.5 L |
| 3.00 | Supply, Installation, Testing and Commissioning of Analog Addressable type Active Repeater Fire Alarm Panel with Backlit LCD display, having controls for reset, mute, accept, silence alarms and self test conforming to BS5839 standards with all labour and materials required to complete the job in all respect up to the entire satisfaction fo engineer-in-charge of work.
Make : Morley ZX R-A / Bosch FMR / Siemens FT201. | 2 | Each | 1,08,700 ₹2.2 L | 80,500 ₹1.6 L | 1,04,650 ₹2.1 L |
| 4.00 | Supply, Installation, Testing and Commissioning of addressable Heat detector with fixed and rate of raise feature including mounting base with LED… etc. complete as required. Each Detector should have 2 inbuilt Isolators as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005 .Detector should monitor Electromagnetic interference and report to the panel - current and average values. Detector should have IP40 or better protection rating. EMC safety for detector shall be 50 V/m. Shall be UL/EN/VDS certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector).
Make: Morley HM/RHSE/I plus MI/B501AP/IV/ Bosch FAH-425-T plus MS400B/Siemens HI720 plus DB 721. | 324 | Each | 3,250 ₹10.5 L | 3,480 ₹11.3 L | 3,150 ₹10.2 L |
| 5.00 | Supply, Installation, Testing and Commissioning of addressable multi sensor smoke detector including mounting base with LED… etc. complete as required with 2 inbuilt Isolators as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements: Drift Compensation feature and Automatic addressing. Detector should monitor Electromagnetic interference and report to the panel - current and average values.Detector should have IP40 or better protection rating. EMC safety for detector shall be 50 V/m. Shall be UL/EN/VDS certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector)
Make: Morley HM/PTSE/I plus MI / B501AP/IV / Bosch FAP-425-OT plus MS400B / Siemens OH720 plus DB721 | 588 | Each | 3,280 ₹19.3 L | 3,550 ₹20.9 L | 3,250 ₹19.1 L |
| 6.00 | Supply, Installation, Testing and Commissioning of Intelligent Analog Addressable type Manual Call Point having Surface or flush mounting option fully compliant to EN 54 having Rotary Decade switches for addressing with back box for mounting as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work.
Make : Morley HM/MCP/Glass/ Bosch FMC-210- DM-G-R/ Siemens FDM22. | 44 | Each | 5,160 ₹2.3 L | 4,100 ₹1.8 L | 4,850 ₹2.1 L |
| 7.00 | Supply, Installation, Testing and Commissioning of Addressable Control Relay Module with flexible network structures with a maximum switching current of 1A @ 30V DC. Shall be EN54/UL/VDS Certification
Make : Morley MI/DCMO/Bosch FLM-420-RLV1-E/Siemens FDCIO221 | 5 | Each | 6,500 ₹32,500 | 5,925 ₹29,625 | 6,200 ₹31,000 |
| 8.00 | Supply, Installation, Testing and Commissioning of Addressable Monitor Module for monitoring of a line with EOL resistor/ Potential free contact/voltage monitoring shall be EN54/UL/VDS approved. (In case of 2 monitoring features in one module (points) each point shall be consider separately for payment).
Make : Morley MI DMMI/ Bosch FLM-420-O1I1-E/Siemens FDCI221 | 5 | Each | 6,500 ₹32,500 | 5,925 ₹29,625 | 6,370 ₹31,850 |
Tender Value
₹70.5 L
EMD Value
₹1.4 L
Closing Date
14 Jul 2025, 5:00 pmClosed
AMIT GOYAL
ED - Rohtak
Provision of Control Panel, Repeater Panel, Smoke Detector, MCBs alongwith wiring and other accessories have been taken in this estimate
2025_HRY_456246_1
20258A60490E 0DA6 428A 8343 9529106DA467667BAR
Open Tender
Electrical Works
90 days
Rohtak
Technical documents as per approved DNIT conditions.
3 documents required · 3 mandatory
₹5,000
₹1.4 L
Yes
13 Jan 2026
4 Jul 2025
15 Jul 2025
4 Jul 2025
14 Jul 2025
4 Jul 2025
Amount
HSR Items
[23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. [Through Rate]
NS Items
Supply, Installation, Testing and Commissioning of Micro processor based 2 wire fault tolerant, networkable type Fire Alarm / Detection Control Panel (having Detector nos 912. of required loops to suit minimum 20% extra over the nos. of fire detectors. The panel shall be able to give location of all fire / fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON/OFF respective control module when ever any alarm is triggered. The panel shall have rectifier, loop cards, minimum 160 characters LCD unit/ 5.7’’TFT to indicate Fire / Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects. The Panel Shall be sheet Steel power coated, sealed to IP30. The Panel shall have 20 Zones with individual LED Indicators, expandable to 80 LED Indicators. The Panel shall have 2 Serial Ports. The panel shall have a built in power supply, battery charger maintenance free battery capable of running for a minimum 24 hours operation complete as required. The panel should also have IP30 or better protection. And conforming to BS5839 standards and Duly Approved by EN 54/UL/VDS as per specifications complete in all respect up to the entire satisfaction of Engineer-in – charge of work. Make: Morley ZX5SE,Bosch Avenar 2000, Siemens Cerberus EN.
Supply, Installation, Testing and Commissioning of Analog Addressable type Active Repeater Fire Alarm Panel with Backlit LCD display, having controls for reset, mute, accept, silence alarms and self test conforming to BS5839 standards with all labour and materials required to complete the job in all respect up to the entire satisfaction fo engineer-in-charge of work. Make : Morley ZX R-A / Bosch FMR / Siemens FT201.
Supply, Installation, Testing and Commissioning of addressable Heat detector with fixed and rate of raise feature including mounting base with LED… etc. complete as required. Each Detector should have 2 inbuilt Isolators as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005 .Detector should monitor Electromagnetic interference and report to the panel - current and average values. Detector should have IP40 or better protection rating. EMC safety for detector shall be 50 V/m. Shall be UL/EN/VDS certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector). Make: Morley HM/RHSE/I plus MI/B501AP/IV/ Bosch FAH-425-T plus MS400B/Siemens HI720 plus DB 721.
Supply, Installation, Testing and Commissioning of addressable multi sensor smoke detector including mounting base with LED… etc. complete as required with 2 inbuilt Isolators as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements: Drift Compensation feature and Automatic addressing. Detector should monitor Electromagnetic interference and report to the panel - current and average values.Detector should have IP40 or better protection rating. EMC safety for detector shall be 50 V/m. Shall be UL/EN/VDS certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector) Make: Morley HM/PTSE/I plus MI / B501AP/IV / Bosch FAP-425-OT plus MS400B / Siemens OH720 plus DB721
Supply, Installation, Testing and Commissioning of Intelligent Analog Addressable type Manual Call Point having Surface or flush mounting option fully compliant to EN 54 having Rotary Decade switches for addressing with back box for mounting as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. Make : Morley HM/MCP/Glass/ Bosch FMC-210- DM-G-R/ Siemens FDM22.
Supply, Installation, Testing and Commissioning of Addressable Control Relay Module with flexible network structures with a maximum switching current of 1A @ 30V DC. Shall be EN54/UL/VDS Certification Make : Morley MI/DCMO/Bosch FLM-420-RLV1-E/Siemens FDCIO221
Supply, Installation, Testing and Commissioning of Addressable Monitor Module for monitoring of a line with EOL resistor/ Potential free contact/voltage monitoring shall be EN54/UL/VDS approved. (In case of 2 monitoring features in one module (points) each point shall be consider separately for payment). Make : Morley MI DMMI/ Bosch FLM-420-O1I1-E/Siemens FDCI221
Supply, Installation, Testing and Commissioning of Addressable Loop powered sounder with strobe/flasher complete with mounting base as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer - in Charge of work. Make: Morley WSO-PR-N05/Bosch FNM-420/Siemens FDS224R
Supply, Installation, Testing and Commissioning of Glow Type Exit Sign Board photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink Sulphate as bare chemical class - I material PSPA fixed on 3 mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener including cost of labour and material required to complete the job in all respect up to entire satisfaction of Engineer-in-Charge of work. Make Pearl/Giolite/OMEX.
Supply, Installation, Testing and Commissioning of minimum 1000 Mtr. Range Siren generator provided at the roof of the building with separate power suppl, relay etc. with all accessories required to complete the job in all respect up to the entire satisfaction of engineer incharge. Make: National/Kheraj
Supply, Installation, Testing and Commissioning of battery backup for controllers (5 KVA UPS on line with 2 hours backup) Make Libert/ Microtek/Eton.
Supply, Installation, Testing and Commissioning of PVC unsheathed s/c stranded ( ISI marked ) copper contuvtor cable 1100v grade in existing pipe excluding cost and erection of pipe but including connection etc. with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer – in charge of work MAKE FINOLEX/POLYCAB/PLAZA PVC unsheathed copper size 1.5 sq mm single core.
Supply, Installation, Testing and Commissioning of Booster amplifier 480 watts Frequency response: 60 Hz to 15 khz ( plus 1/3db), Inputs :XLR and phone jack , Input 1, Input 2-4, Impendence :20kO, Sensitivity : 1 V balanced , S/N ): )85 dB complete in all respect Make /BOSCH/ Siemens/Honeywell
Supply, Installation, Testing and Commissioning of Horn Loudspeaker 15 watts . Max power 22.5 W, Rated power (PHC) 15 W ( 15,7.5,3.75 W) ,Sound pressure Level rated power 103dB ( At 1kHz,Iw,Im), Effective frequency range (-10dB) 500Hz to 5KHz ,Opening angle (at 1 kHz/4kHz,-6 dB), Rated voltage 100V . Rated impedance 667ohm. Ambient temperature range -25 to plus 55 C .Connection 4 wire cable, 50 cm long complete in all respect. Make /BOSCH/ Siemens/Honeywell
Supply, Installation, Testing and Commissioning of Cabinet and Ceiling Speaker Max Power - 9 W ,Rated power (PHC) - 6 W(6-3-1.5), Sound pressure level at rate power /1 w ,(at1kHz,1m) (at 1 kHz, 1 m) - 96dB/ 90dB,Effective frequency range (-10 dB) - 200-15000 Hz,Opening angle (at 1 kHz/4 kHz, - 6 dB),In degrees - 150/70,Rated voltage - 100 V,Rated impedance - 1667 Make /BOSCH/ Siemens/Honeywell
Supply, Installation, Testing and Commissioning of 17 U Standard rack to place all Av equipment Make Valrack, Comrack,Hive Networks.
Supply and erection of FIRE EXTINGUISHERS duly hang on wall with necessary hook complete in all respect Make: Safex/Minimax/ Ceasefire ABC Dry power type fire Extinguishers of 5 kg. capacity
Supply and erection of FIRE EXTINGUISHERS duly hang on wall with necessary hook complete in all respect. Make: Safex/Minimax/ Ceasefire Co2 type fire extinguishers of 4 Kg capacity
Supply, Installation, Testing and Commissioning of wiring for PA system with the following sizes of FRLS insulated copper conductor single core 1100 volts grade cables in existing surface/recessed M.S. conduit etc. as complete as required. Make Finolex/Havel/Plaza. 2 x 1.5 Sqmm
Insat Techno Services (BID ID -1293488)
Netromics Engineering Solutions Private Limited (BID ID -1295874)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid