Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAdmitted-Finance 2ND FLOOR 45 A MAA SHARDA NAGAR KABIT KHEDI INDORE NEAR BHRAT PUBLIC SCHOOL MR 10 SQUARE INDORE MADHYA PRADESH 452010 | INDORE | MADHYA PRADESH | 452010 | ₹1.2 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.5 Cr+₹25.5 L (20.7%)Admitted-Finance | ₹1.5 Cr+₹25.5 L (20.7%) | L2 | Admitted-Finance |
| 3 | L3₹1.6 Cr+₹39.6 L (32.3%)Admitted-Finance | ₹1.6 Cr+₹39.6 L (32.3%) | L3 | Admitted-Finance |
| 4 | L4₹1.7 Cr+₹45.1 L (36.7%)Admitted-Finance 19 DNYANDA CO OPP HSG SOC NEAR HOTEL NEW PADMA KAMATHWADA NASHIK NASHIK MAHARASHTRA 422009 | NASHIK | MAHARASHTRA | 422009 | ₹1.7 Cr+₹45.1 L (36.7%) | L4 | Admitted-Finance |
| 5 | No RankAdmitted-Finance | - | No Rank | Admitted-Finance |
| Sl No | Description | Qty | Unit | SARAF ELECTRICALS L3 | S. KUMAR CREATION PVT LTD L1 | CHETANA ELECTRONICS AND ELECTRICALS L4 | SUNLIGHT NETWORK No Rank | FLASHCUNSULTANT & CONTRACTOR L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Only pulling of OFC through existing HDPE pipe/ RCC hume pipe/ GI pipe/ MS conduit/ on wall/trench by supply and fixing of clamps and other required hardware and as per detailed description of items and as instructed by EIC. (Cable will be supplied from Department Free of cost.) | 42,826 | meter | 26 ₹11,13,476 | 36.11 ₹15,46,446.86 | 33.75 ₹14,45,377.5 | 20 - | 18 ₹7,70,868 Lowest |
| 2.00Supply and installation of HDPE Pipe of 50 mm outside diameter, PE63 material grade and PN4 pressure rating of wall thickness minimium 2.4 as per latest IS as detailed below: | ||||||||
| 2.10 | Laid under ground:
Laying of HDPE pipe by excavation in all types of soil, hard / murrum / rock / boulders 600 mm to 900 mm below ground level as per site condition and as instructed by EIC, protective covering with bricks on two sides and on the top (width wise) and refiling the trench, compacting including watering, leveling the disposing of excess soil within 500 meter radius. | 31,124 | meter | 390 ₹1,21,38,360 | 165.11 ₹51,38,883.64 Lowest | 439 ₹1,36,63,436 | 390 - | 376 ₹1,17,02,624 |
| 2.20 | On Wall/Trench//Cable Tray:
By supply and fixing of MS clamps and other hardware required as per requirement | 3,658 | meter | 190 ₹6,95,020 | 940.11 ₹34,38,922.38 | 120 ₹4,38,960 | 23 - | 100 ₹3,65,800 Lowest |
| 2.30 | Through Hume pipe:
Pulling through existing RCC Hume pipe etc. | 1,571 | meter | 129 ₹2,02,659 | 35.11 ₹55,157.81 Lowest | 93 ₹1,46,103 | 10 - | 88 ₹1,38,248 |
| 3.00Supply and installation of B class GI pipe with cutting and drilling etc. | ||||||||
| 3.10 | 50 mm diameter | 24 | meter | 440 ₹10,560 Lowest | 480.11 ₹11,522.64 | 465 ₹11,160 | 520 - | 490 ₹11,760 |
| 3.20 | 100 mm diameter | 24 | meter | 950 ₹22,800 Lowest | 1,200.11 ₹28,802.64 | 980 ₹23,520 | 640 - | 1,200 ₹28,800 |
| 4.00Supply and installation of RCC spun/hume pipes with collers including excavation as per specification | ||||||||
| 4.10 | 150 mm Diameter N.B. | 42 | meter | 550 ₹23,100 | 600.11 ₹25,204.62 | 373 ₹15,666 Lowest | 350 - | 580 ₹24,360 |
Tender Value
₹1.6 Cr
EMD Value
₹3.1 L
Closing Date
28 Jun 2025, 3:30 pmClosed
Chief Engineer, RRCAT, Indore
Office of Chief Engineer, RRCAT, Indore- 452013
OFC laying and associated work for air isolated network at RRCAT Indore.
2025_RRCAT_862887_1
RRCAT/E/2025/09 dated 02.06.2025
Open Tender
Electrical Works
Works
485 days
RRCAT
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹3.1 L
10 Sept 2025
6 Jun 2025
2 Jul 2025
7 Jun 2025
28 Jun 2025
12 Jun 2025
Amount
Only pulling of OFC through existing HDPE pipe/ RCC hume pipe/ GI pipe/ MS conduit/ on wall/trench by supply and fixing of clamps and other required hardware and as per detailed description of items and as instructed by EIC. (Cable will be supplied from Department Free of cost.)
Supply and installation of HDPE Pipe of 50 mm outside diameter, PE63 material grade and PN4 pressure rating of wall thickness minimium 2.4 as per latest IS as detailed below:
Laid under ground: Laying of HDPE pipe by excavation in all types of soil, hard / murrum / rock / boulders 600 mm to 900 mm below ground level as per site condition and as instructed by EIC, protective covering with bricks on two sides and on the top (width wise) and refiling the trench, compacting including watering, leveling the disposing of excess soil within 500 meter radius.
On Wall/Trench//Cable Tray: By supply and fixing of MS clamps and other hardware required as per requirement
Through Hume pipe: Pulling through existing RCC Hume pipe etc.
Supply and installation of B class GI pipe with cutting and drilling etc.
50 mm diameter
100 mm diameter
Supply and installation of RCC spun/hume pipes with collers including excavation as per specification
150 mm Diameter N.B.
300 mm Diameter N.B.
Supply and installation of cable route marker for OFC with masonry work
Road/PCC path cutting: Bituminous/ WBM/PCC path cutting for laying Hume/ GI pipes
Removing & re-installation of paver block including all required material and as instructed by EIC
Excavation of trench in all types of soil soft/ hard murrum/ rock/ boulders including back filling and spreading of excess earth. within 50 meter radius
Repairing of road/ path ways by providing & laying in position Cement concrete 1:2:4 using graded stone aggregate 40 mm max. size including consolidation, finishing, curing etc. Complete
FLASHCUNSULTANT & CONTRACTOR (BID ID -3239084)
SARAF ELECTRICALS (BID ID -3239056)
CHETANA ELECTRONICS AND ELECTRICALS (BID ID -3239765)
SUNLIGHT NETWORK (BID ID -3239251)
Bidder Name
SUNLIGHT NETWORK
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .