Loading…
Loading…
Tender ID
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹21.8 LAdmitted-Finance | L1 | Admitted-Finance | ||
| 2 | L2₹22.2 L+₹40,410.68 (1.85%)Admitted-Finance HNO 1131 TIVIM BARDEZ GOA | TIVIM | BARDEZ | GOA | 403507 | L2 | Admitted-Finance |
Tender Value
₹20.2 L
EMD Value
₹40,411
Closing Date
17 Mar 2026, 5:00 pmClosed
Executive Engineer
O/o Executive Engineer Elect. Dept. DIV-XVII Mapusa
erection of 100 KVA DTC anjuna
2026_ED_28175_1
54(25-26)/5545 Dt06/03/2026
Open Tender
Electrical Works
Percentage
90 days
dmello vaddo anjuna
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
₹40,411
21 May 2026
11 Mar 2026
18 Mar 2026
11 Mar 2026
17 Mar 2026
11 Mar 2026
COST OF MATERIAL
DTC Metering Unit
Common (AMR) Modem
11 KV Enamelled danger board 11000 vots CEE/E-490
Transformer Plingth
GI Tubular Fencing complete with gate and side dismanteling system as per the specification for DTC and FP(size 4Mx3Mx2M) with concreting for GI Fencing supports with plingth(0.3x0.3x0.5) CuMtsx12 nos each ratio 1:3:6 and bick masonary {galvanising should be hot dipped galvanised as per IS:2629/66, minimum zinc coating of 1000gms/sqmts, 140Microns DFT, suitable for high salinity coastal areas}
S&E of HDG earthing strip for connecting earthing pipe and other equipment of size 25X5mm
11 KV 630 A, outdoor, sf6 RMU unit with two two load break switch and one circuit breaker: Extensible/Non-Extensible Two (2) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 and One (1) vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.
3C11KV armoured cable 300Sqmm
3C 11KV armoured cable 95 Sq.mm
3C 11KV staright through joint 300Sqmm
Indoor termination kit for 300 Sq. mm. 11KV cable
Indoor termination kit for 95 Sq. mm. 11KV cable
Cable Route marker
Sand for cushioning of HT/LT underground cables.
Supply and laying of RCC protective covers
Warning tape.
Painting of pole number on Transformer Center & Poles
COST OF ERECTION
100KVA 11KV/0.4KV: Distribution transformer level II losses, aluminium winding, with bimetallic terminal, connectors, Energy Efficiency level-II as per:1180 (part-I):2014
MS distribution box of 200 Amps MCCB Capacity and four feeder arrangements.
XLPE Single Core unarmoured XLPE 300 sq mm 1.1KV grade
DTC Metering Unit
11 KV Enamelled danger board 11000 vots CEE/E-490
HDGI earthing pipe 2.5Mts long 40mm nominal bore, fabricated & perforated including alternate layers 30cm thick of charcoal, salt & earth (charcoal & salt --20Kgs each per pit) inclusive of excavation, backfilling & spreading of excavated earth evenly. Complete with Brick masonary
RMU Plingth
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 min width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : a. All kinds of soil
Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete.
Providing & laying cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded granitic or basaltic stone aggrt. 20 mm. nominal size) excluding cost of centering, shuttering and finishing in: a. All works upto plinth level
Providing and laying in position (1:11/2:3) Reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinfrocement (1 cement: 1½ coarse sand: 3 graded stone agg 20mm nominal size) a. All works upto plinth level
Providing TMT steel reinforcement bars of (SAIL, TATA, VIZAG, JSW Steel Ltd.) (Confirming to IS 1786 of 1986) for RCC work) (conforming to I.S. 1786 of 1986) including bending, binding & placing in position in allthe floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member.
Centering & shuttering including Strutting, Propping & removal of forms for: a. Foundations, Footings, Bases for columns
12mm cement plaster 1:4 (1 cement : 4 fine sand)
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by engineer in Charge.
Transformer Plingth
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 min width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : b. All types of Ordinary rock including all types of laterite rock, blasting prohibited
Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete.
Providing & laying cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded granitic or basaltic stone aggrt. 20 mm. nominal size) excluding cost of centering, shuttering and finishing in: a. All works upto plinth level
Providing and laying in position (1:11/2:3) Reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinfrocement (1 cement: 1½ coarse sand: 3 graded stone agg 20mm nominal size) a. All works upto plinth level
Providing TMT steel reinforcement bars of (SAIL, TATA, VIZAG, JSW Steel Ltd.))(Confirming to IS 1786 of 1986) for RCC work (conforming to I.S. 1786 of 1986) including bending, binding & placing in position in allthe floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member.
Centering & shuttering including Strutting, Propping & removal of forms for: i. Foundations, Footings, Bases for columns
12mm cement plaster 1:4 (1 cement : 4 fine sand)
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge.
TRANSPORTATION AND CARRIAGE OF MATERIALS (A)By tipper truck including loading, unloading and stacking (A)Lime,building rubbish, manure sludge, moorum excavated rock (ii)Earth (upto 5 km)
GI Tubular Fencing complete with gate and side dismanteling system as per the specification for DTC and FP(size 4Mx3Mx2M) with concreting for GI Fencing supports with plingth(0.3x0.3x0.5) CuMtsx12 nos each ratio 1:3:6 and bick masonary {galvanising should be hot dipped galvanised as per IS:2629/66, minimum zinc coating of 1000gms/sqmts, 140Microns DFT, suitable for high salinity coastal areas}
S&E of HDG earthing strip for connecting earthing pipe and other equipment of size 25X5mm
11 KV 630 A, outdoor, sf6 RMU unit with two two load break switch and one circuit breaker: Extensible/Non-Extensible Two (2) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 and One (1) vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.
3C11KV armoured cable 300Sqmm
3C 11KV armoured cable 95 Sq.mm
3.5 Core 120 Sqmm LT UG cable
3C 11KV staright through joint 300Sqmm
Indoor termination kit for 300 Sq. mm. 11KV cable
Indoor termination kit for 95 Sq. mm. 11KV cable
Cable Route marker
Excavation in any type of soil including hard laterite soil.
Refilling of excavated soil.
Supply and laying of RCC protective covers
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
cancelled_1.pdf
pdf • 0.44 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 21.42 MB
Tendernotice_2.pdf
PDF • 15.87 MB
Tendernotice_3.pdf
PDF • 1.05 MB
BOQ_28620.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .