| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 CrAccepted-AOC 1 206 SHOP NO 71 MANDIR MARKET SADAR BAZAR DELHI CANTT 110010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | ₹1.8 Cr | L1 | Accepted-AOC Being lowest and reasonable |
| 2 | L2₹1.8 Cr+₹1.5 L (0.85%)Rejected-Finance A 212B GALI NO 1 SHAKARPUR | DELHI | EAST DELHI | DELHI | 110092 | ₹1.8 Cr+₹1.5 L (0.85%) | L2 | Rejected-Finance Not being lowest |
| 3 | L3₹2.0 Cr+₹15.6 L (8.63%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | ₹2.0 Cr+₹15.6 L (8.63%) | L3 | Rejected-Finance Not being lowest |
| 4 | L4₹2.0 Cr+₹17.3 L (9.60%)Rejected-Finance RZ 31 222 J BLOCK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | ₹2.0 Cr+₹17.3 L (9.60%) | L4 | Rejected-Finance Not being lowest |
| 5 | L5₹2.0 Cr+₹24.4 L (13.5%)Rejected-Finance C 9 53 IIND FLOOR SECTOR 08 ROHINI DELHI 110085 | DELHI | NORTH WEST DELHI | DELHI | 110085 | ₹2.0 Cr+₹24.4 L (13.5%) | L5 | Rejected-Finance Not being lowest |
Tender Value
₹2.5 Cr
EMD Value
₹3.2 L
Closing Date
16 Apr 2025, 6:00 pmClosed
HQ Chief Engineer Delhi Zone
HQ Chief Engineer Delhi Zone Delhi Cantt-10
SPECIAL REPAIR TO BLDG NO P38 ORS LIVING AND COOK HOUSE OF CBPO UNDER GE SOUTH DELHI CANTT
2025_MES_697564_1
CEDZ/TOKEN-04 OF 2025
Open Tender
Civil Works
Item Rate
270 days
Delhi Cantt-10
As per NIT
10 documents required · 10 mandatory
₹2,000
GE South
₹3.2 L
Yes
4 Jul 2025
12 Feb 2025
18 Apr 2025
12 Feb 2025
16 Apr 2025
2 Apr 2025
12 Feb 2025 - 19 Feb 2025
Amount
M&L for Preventive treatment against the danger of carbonation in exposed faces of RCC members :- (i) Cleaning existing surfaces of RCC members and making surface free of loose material, oil, grease etc. by vigorous wire brushing including light grit blasting where necessary as recommended by Engr-in-charge. (ii) Further, cleaning using biocide(as recommended by manufacturer) to ensure that surface is free of algae and fungus and no trace of paint (any type) left out. Sand blasting to be done to remove trace of paint. (iii) Cleaned surface to be allowed to dry. (iv) Spray a coat of primer (as recommended by manufacturer) over dry cleaned surface as required prior to final finish. Primer shall be diluted in proposition 2:1 with mineral turpentine. After application, primer shall be allowed to dry for 03 hours or as directed. (v) Apply a coat of neat Aliphatic Acrylic anti-carbonation (ACC) over the primed surface with air / spray gun at nominal rate of 3.5 ltrs per sqm as recommended by manufacturer. (vi) Apply a more coat of Aliphatic Acrylic anti-carbonation (ACC) after 5-6 hours as recommended by manufacturer complete all as specified and directed. (vii) Sprinkle sand cover over surface to receive new.
M&L for followings :- (i) Removing plaster & finishes all around the coloumns, slabs & beams (on all four sidescription of column to full height , three sidescription of beam to entire span & bottom of slab to area as directed) (ii) After cleaning gently removing cover concrete using pneumatic/electric chipper or any other approved tool in entire portion of structural member (removal of cover concrete shall be done to an extent when reinforcement is visible) (iii) Removal of cover concrete with under cutting of up to a depth of 20mm beyond reinforcement around full circumference & full length of bar where directed. (concrete shall be stripped to an extent concrete substrate is exposed) (iv) Cleaning exposed concrete substrate by using water jet. (v) Removing visible rust along the length of reinforcement using hand tools as approved. (The Engr-in-charge may order sand blasting if rust is approved) (vi) Any other work as directed by Engr-in-charge to present clean surface for determination of type of repair to be carried out complete all as specified and directed.
M&L for providing rust proof /anti corrosive treatment to bars :- (i) cleaning of all exposed bars (new & old) alround (ii) Apply a single coat of Alkaline rust converting primer on alround bars new & old as recommended by the manufactuer (iii) Apply two coats of Epoxy phenolic anti corrosive protective coat on bars alround new & old as recommended by the manufactuer. Note : Anti corrosive treatment shall be continuous espcially in the regions where pitting, imperfections, etc were present on the surface of the bars. It is important that the rear portions of re bars (those towards the concrete substrate) should not be left without coating. Superficial area of member to be considered for measurement.
M&L for providing PMM (Polymer modified cementitious mortar) :- (i) Dry sub strate surface and free of debris & dust (ii) Applying Epoxy bond coat on the sound substrate using approved spray machine & ensuring that no pin holes are visible.(In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes). (iii) Immediately after application of epoxy bond coat as above apply PMM (Polymer modified cementitious mortar) of 25 mm thickness. Note : Application of PMM shall be preferably be in coats of appx 10mm thickness. PMM work shall be executed in fairely rapid successions so as entire work is completed with in 30 mins). PMM shall be pre packed ready to use. (iv) PMM surface to be moist cured for three days followed by air curing in temperature as recommended by manufactuer complete all as specified and directed.
M&L for Providing & Pouring Micro concreting M-40 grade :- (i) Dry concrete substrate surface and free of debris & dust (ii) Applying Epoxy bond coat on the sound concrete substrate using approved spray machine & ensuring that no pin holes are visible. (In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes). (iii) Immediately after application of epoxy bond coat as above pour Micro concreting M40 grade, Make : MasterEmaco S46T of BASF or equivalent FOSROC/SIKA using approved mixing machines/pumping under pressure via approved pneumatic pump at the locations to be repaired in RCC beams & columns etc,. Adding of aggregates will be permitted only as per manufacturer’s recommendation without compromising the strength. The rate shall include cost of all materials (except re-bar) labour charges for mixing, pouring concrete, cost of tools, lead & lift of materials, transportation etc., to carry out the complete work complete all as specified and directed.including M&L for use & waste of form work using steel sheets , steel bracing, propping etc around structural members where micro concreting to be done and keeping form work in position till required specified period complete all as specified and directed. Note : Form work shall be 100% leak proof. For purpose of payment area in touch with concrete shall be measured. Note : The cost of micro concrete M-40 grade & Epoxy bond coat is inclueded in this item.
S&F for stengthening existing reinforcement by use of mild steel bars of any dia , cut to length, bent to shape required, including cranking, bending spirally and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
M&L for chipping out spilled and loose concrete cover and derusting steel reinforcement of concrete column, beam, slab, chajjas, parapets and the like as directed up to 25 to 35mm thick roughening and cleaning concrete surface with steel wire brushes, washed with water and allowed to dry including derusting steel wire reinforcement, providing fabric MS wire mesh 75 x 75 x 2mm as reinforcement to concrete surface applying adhesive/admixture over steel mesh and providing 25mm average thickness guniting mix using one part of OPC 53 grade and two part of sand mixed with adhesive/admixture @ pressure of 2.5 to 3.00kg/Sqcm by guiniting machine and surface finished even and fair including necessary padding, shuttering/scaffolding, formwork (guniting work to be carried out up to 10 metre height) complete as directed at site Note :- (a) After placing the additional reinforcement all concrete surfaces shall be thoroughly scrubbed with wire brushes, washed with water and allow to dry, apply chemistic polycretes admixture @ 2.25 kg by weight of cement all as per manufacturers instruction. (b) when polymix concreting in taking condition,guiniting is done with polycrete admixture @ 2% by weight of cement all as per manufacturers instructions (polycrete admixture shall be procured from chemical adhesive Pvt Ltd Co or their authorised dealer). (c) Cost of the above aspect shall be deemed to be included in the quoted rate of the respective item and nothing extra shall be paid on any account.
Demolition of RCC of any description, in any position roofs, floors (other than ground floors), beams staircases, landing, chajjas, RCC overhead tank and similar suspended work and removing excavated material /demolition material exc. 1.50 km but n exc.5 km including taking down from upto four storey ,complete all as specified and directed.
M&L for use & waste of form work to chullah hoods, chajjas, troughs and similar items including edges for rough finished surfaces of concrete, complete all as specified & directed.
M&L for RCC 1 : 1.5 : 3 type A1 using 20mm graded crushed stone aggregate as in chajjas, slab, landing etc, complete all as specified & directed.
M&L for use & waste of form work to soffits of suspended slabs such as roof slabs, floor slabs landings and similar work, not exceeding 200mm thick (horizontal or sloping) for rough finished surfaces of concrete, complete all as specified & directed.
S&F TMT bars 10mm dia as in reinforcement of RCC of any description, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified & directed.
S&F TMT bars 8mm dia as in reinforcement of RCC of any description, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified & directed.
Demolition of bricks (laid flat or on edge) or brick tiles in floors, channels, kerbs, aprons, etc. (each layer) laid, bedded and pointed in any mortar, complete all as specified & directed.
Demolition Mud in roofs, any thickness, including plastering and lapping (whether full thickness removed or only a part thereof), complete all as specified and directed.
Removing soil, excavated material to a distance exc. 1.5Km but n exc 5km and depositing where directed at above the starting point, complete all as specified and directed.
M&L for cement concrete 1:2:4 type B1 using 20 mm graded crushed stone aggregate on roof padding, surface finished even and smooth without using extra cement, complete all as specified & directed.
M&L for 10 mm thick plaster on concrete surfaces in cement mortar (1:4) on roof, mixed with water proofing compound and finishing the surface even and smooth without using extra cement, complete all as specified & directed. (Water proofing compound shall be measured and paid for seperately).
M&L for APP based polymeric membrane one side rough finish (to receive SRI tile) and other side plain finish, minimum weighting 3 kg/Sqm and minimum 3mm thick reinforced with polyster non woven fabric (wt not less than 150 gms/sqm) over one coat of 85/25 bitumen @1.2 kg/sqm and paste the membrane with torching method and again apply a coat of 85/25 bitumen @ 1.2 kg/sqm at overlapping joints, complete all as specified & directed.
M&L for preparation of new surface of APP membrane and applying two coats of aluminium paint at surfaces of any description, over 10cm in width or girth,not otherwise described, complete all as specified & directed.
S&F Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner, complete all as specified and directed.
Demolition of cement concrete (un-reinforced) of any description in any position not otherwise specifically provided for, complete all as specified & directed.
M&L for cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate in roof kerbs or mud stops, rounded or chamfered and hold fast on edge including necessary form work, complete all as specified & directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc., laid, bedded and pointed in any mortar, complete all as specified & directed.
M&L for Granite (of any type) work, 18-20 mm thick jade black (table rubbed and polished) in cooking platforms, lift wall, skirtings where ever required and likes on cement mortar bedding of 20mm thick in cement mortar 1:4 including pointing in white cement using marble dust with admixture of pigment to match, complete all as specified and directed. Notes: (a) Additional 75mm width patti shall be measured separately. (b) Minimum rate of granite should not be less than Rs. 1500/- per Sqm including GST.
M&L for Udaipur green marble work 18 to 20mm thick (table rubbed and polished) in window-cills,on floor and like in 20 mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble of any shade other than white and black, complete all as specified and as directed.
M&L for machine cut kota stone slab flooring, steps (one piece) , 20-25 mm thick, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing, grinding and polishing laid over and including 20mm screed layer in cement mortar 1:4, complete all as specified & directed.
M&L for machine cut kota stone slab, 20-25 mm thick as in vertical surfaces such as skirting/dado etc., laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing, grinding and polishing, laid over and including 10mm thick screed bed in cement mortar 1:3, complete all as specified & directed.
Rounding to edges of stone slabs one edge, such as in steps cooking platefom and other similar situations, complete all as specified and as directed
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified & directed.
M&L for glazed ceramic coloured tiles of size 600mmx300mm, thickness 7 to 8mm as in vertical surfaces such as wall, pillar, skirting, dado, wall etc., set and jointed in neat cement slurry and pointed with coloured cement to match over and including 10mm thick rendering in cement mortar 1:3, complete all as specified & directed.
M&L for non skid coloured rectified ceramic tiles of size 300x300mm of 7 to 8 mm thick in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in cement mortar 1:4, complete all as specified and directed.
Roughening surfaces of old concrete floor/wall by picking, sweeping clean and washing down with water to remove dust, etc and brushing and applying neat cement slurry with 3.0 Kg of cement per sq metre, complete all as specified and directed.
S&F for glazed ceramic tiles 9 to 10 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm ( size 600 mm x 600 mm), in floors/skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, complete all as specified and directed.
M&L for 15mm thick screed bed or bedding in cement mortar 1:4, complete all as specified and directed.
M&L 10mm thick backing coat of cement mortar 1:3, complete all as specified and directed.
S&F in repairs vitreous china squatting pan, (Orissa pattern) size 580x440mm white with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap etc complete including making good to floor, complete all as specified and directed.
S&F in repair Vitreous China wash down water closet pan EWC (pedestal pattern) , white incl fixing bolts, flushing cistern and flush pipe etc, complete all as specified and directed.
Supply only plastic water closet seat, white/black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminium hinging device, complete all as specified & directed.
S&F PVC low level white flushing cistern valveless symphonic action type 10 lts capacity IS marked with inlet, ball valve, float and handle including PVC flush pipe 32 mm dia with bend and a pair of mild steel angle iron brackets of suitable size including making necessary connections to water supply pipe line and WC, (ISI Marked), complete all as specified & directed.
S&F in repairs 15 mm dia 600mm long PVC connections with brass check nut, complete all as specified & directed.
S&F in repairs vitreous china wash hand basin counter sunk, oval shaped, any colour of minimum size 560mm x400mm x205mm excluding taps, waste chain and plug and porcelain stopper and waste pipe & waste coupling including all necessary fittings and fixtures etc, complete all as specified & as directed.
S&F in repairs brass chromium plated mode 2 in 1 WHB mixture swan neck long type 15mm dia including necessary fittings model Quarter half turn (SOLO) complete all as specified & directed.
S&F 15 mm dia Bib taps long body, cast copper alloy with crutch or capstan head , screwed down, screwed for iron pipe or for brass ferrule and fixed, fancy type chromium plated, complete all as specified and directed
S&F in repairs Soap dish, brass chromium plated, fancy type of size 100x60mm, fixed to walls with chromium plated screws, complete all as specified & directed.
S&F in repairs brass chromium plated tubular towel rail, 20 mm dia D type , 60 cm long between flanges, complete all as specified & directed.
S&F for 15mm fancy type chromium plated with long shunk and cup concealed type stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified and directed
S&F toilet paper holder with flat recessed type stainless, complete all as specified and directed
S&F in repairs Vitreous China urinals, half stall type (back or corner wall type),complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe including urinal spreader, complete all as specified and directed
S&F in repairs PVC waste pipe 32/40 mm bore, 65 cm long for sink etc, complete all as specified and directed
S&F in repairs chromium plated brass overhead shower rose 125mm with arm, complete all as specified and directed.
S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position, complete all as specified and directed.
S&F in repairs angle valves, 15mm bore, fancy type, chromium plated, cast copper alloy with capstan head, screwed down, high pressure, both ends screwed for iron pipe or for union etc., complete all as specifed & directed.
S&F 2-in-1 bib tap fancy type, chromium plated brass, 15mm, , complete all as specifed & directed.
S&F in repairs corner with Z Black granite piece quadrant shape radius 250-300 mm with minimum thickness 20mm including cutting, moulding polishing and fixing arrangement on walls at corner etc, complete all as specified and directed.
S&F in repairs Glass shelf assembly 5.5mm thick, 600mm long 120mm wide with cp railing complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level), complete all as specified & directed.
M&L for applying a coat of cement slurry @ 0.488 Kg/Sqm mixed with tapercreate @ 0.253 Kg/Sqm after cleaning and drying the old/new surfaces(Make of tapercreate M/S CICO Engg Services) then applying the layer of fibre glass cloth while the above coat is still green. The overlap of fibre glass cloth shall be not less than 100 mm.(Make of fibre glass cloth M/S The Structure Water Proofing Co Pvt Ltd) and then applying 1.5 mm thick layer @ 1.288 Kg/Sqm mixed with taper create @ 0.570 Kg/Sqm and coarse sand @ 1.289 Kg/Sqm. Allow the treatment to air curing for four hours followed by water curing for 48 hours, complete all as specified & directed.
M&L for 10 mm thick cement plaster on brick/ concrete surface in cement mortar 1:3, finished even and smooth surface with out using extra cement but mixing water proofing compound at the rate of 2% of cement by weight (WPC shall be paid separately).
M&L for cement concrete type E2 (1:5:10) using 40 mm graded crushed stone aggregate in mass concrete in sunken floor, complete all as specified & directed.
M&L 75 mm thick PCC type D2 (1:4:8) using 40 mm graded crushed stone aggregate as in sub base of flooring, complete all as specified & directed.
M&L for 25mm thick cement concrete type B-0 1:2:4 (12.5mm graded crushed aggregate) as in sub floors finished rough, complete all as specified & directed.
Taking up or down steel tubing 15 mm bore and connection including cleaning for refixing. complete all as specified and as directed.
Taking up or down steel tubing 20 mm bore and connection including cleaning for refixing. complete all as specified and as directed.
Taking up or down steel tubing 40 mm bore and connection including cleaning for refixing. complete all as specified and as directed.
M&L for cutting chases or making holes, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth, complete all as specified & directed.
S&F 20mm outer dia CPVC pipes SDR 11 with and including Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors, complete all as specified & directed.
S&F 25mm outer dia CPVC pipes SDR 11 with and including Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors, complete all as specified & directed.
S&F 40 mm outer dia CPVC pipes SDR 11 with and including Plain CPVC SDR 11 fittings for WHB on walls/ceiling or laying in floors, complete all as specified & directed.
S&F 20mm outer dia CPVC Union complete all as specified and directed.
S&F 25mm outer dia CPVC Union complete all as specified and directed.
S&F 40mm outer dia CPVC Union complete all as specified and directed.
S&F 40mm outer dia CPVC Tank Adaptor complete all as specified and directed.
S&F 25mm outer dia CPVC Tank Adaptor complete all as specified and directed.
S&F 20mm outer dia CPVC Tank Adaptor complete all as specified and directed.
S&F 25mm outer dia CPVC ball valve/gate valve complete all as specified and directed
S&F 20mm outer dia CPVC ball valve/gate valve complete all as specified and directed
S&F 20mm outer dia CPVC Brass Elbow complete all as specified and directed.
S&F 20mm outer dia CPVC Male Brass Threaded Adapter (MTA/BTA) complete all as specified and directed
S&F 25mm outer dia CPVC Male Brass Threaded Adapter (MTA/BTA) complete all as specified and directed
S&F 20mm outer dia CPVC Brass Tee complete all as specified and directed
S&F Brass reducer 40mm x 25mm outer dia CPVC complete all as specified and directed
M&L for rotational moulded polyethylene water storage tanks white colour 1000 lts capacity, triple layered (cylindrical vertical with closed top) hoisted and fixed in position including 20 mm dia PTMT float valve, lid tank cover for polyethylene and polyethylene ball including taking out existing unserviceable overhead tank of any description including fitting and fixtures, complete all as specified & directed.
Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan in soft/loose soil and getting out, complete all as specified & directed.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specifed & directed.
Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified & directed.
S&F in repairs Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors of 100 mm dia sand cast pipe, complete all as specified and directed.
M&L for plain cement concrete (1:3:6) type C-2 (using 40mm graded crushed stone aggregate) as in bed to drain pipes of 100mm bore including packing under and haunching against sides of pipes after they are laid and tested, complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store, complete all as specified and directed.
S/F PVC (SWR) 110mm pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, soil, waste, vent pipe in any length with or without ears including clamp as rqd ,110mm bore, complete all as specified and directed.
S/F PVC (SWR) 75mm pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, soil, waste, vent pipe in any length with or without ears 75 mm bore, complete all as specified and directed.
S&F for PVC (SWR) bends any radius, 110 mm bore, complete all as specified and directed.
S&F for PVC (SWR) bends any radius, 75 mm bore, complete all as specified and directed.
S&F for 110 PVC (SWR) Tee with door plate complete all as specified and as directed.
S&F for 75 mm PVC (SWR) Tee with door plate complete all as specified and as directed.
S&F for 75 mm bore PVC (SWR) floor trap, with grating including jointing to waste pipe fixed in solvent cement concrete complete all as specified and directed.
S&F for PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with clamp, of 110 mm dia complete all as specified and directed.
BLANK
M & L for Cement concrete 1:3:6 type C2 using 40mm graded stone aggregate in plinth protection, 75mm thick, finished fair and even without using extra cement complete.
Demolition of brick work built in cement or cement lime mortar complete.
M&L brick work in cement mortar (1:6) using sub class 'B' bricks, straight or curved on plan exc 6 mtr mean radius complete all as specified.
Taking down chowkats or frames with shutters (without taking of shutters from the frames) exceeding 1.5 Sqm but not exceeding 4 Sqm each complete.
Taking down chowkats or frames with shutters not exceeding 1.5 Sqm each (without taking off shutters from the frames) complete.
S&F factory made single extruded WPC (Wood Polymer Composite) solid door/window/ceosetory windows & other frames/chowkhat of size 65 x125 mm comprising of vigin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ricehusk/wheat husk) and non toxicadditives (maximum toxicity index of 12 for 100 g,s) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge.(MS hold fast/hugs or SS dash fasteners shall be paid for separately) Note:- For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
S&F factory made single extruded WPC (Wood Polymer Composite) solid door/window/ceosetory windows & other frames/chowkhat of size 65 x100 mm comprising of vigin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ricehusk/wheat husk) and non toxicadditives (maximum toxicity index of 12 for 100 g,s) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge.(MS hold fast/hugs or SS dash fasteners shall be paid for separately) Note:- For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
S&F factory made single extruded WPC (Wood Polymer Composite) solid door/window/ceosetory windows & other frames/chowkhat of size 45 x 70 mm comprising of vigin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ricehusk/wheat husk) and non toxicadditives (maximum toxicity index of 12 for 100 g,s) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge.(MS hold fast/hugs or SS dash fasteners shall be paid for separately) Note:- For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
S&F Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 35mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer?In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)complete all as specified and directed.
Providing 30mm thick FACTORY-MADE WIRE MESH SOLID WPC DOOR SHUTTER consisting of Density 650 Kg /Cbm Manufactured by an ISO-9001-2015 certified Company, Door to be panelled with SS mosquito Mesh and XTN aluminium Mesh for additional strength and safety purpose. (Confirming as per IS:4020). The door should be water proof, termite proof,fire retardant and having screw holding capacity. Door to be fixed to frame with 3 nos. SS butt hinges size 100mm*25mm*2mm and 32mm long steel screws drilled suitable to pass through Other hardwares shouldbe fixed with 19*6mm size steel screws etc. Complete as per direction of Engineer-in-charge, manufacturer's specification & drawings.” Note: Fixture/fittings shall be measured & paid under relevant item.
S&F Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer?In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)complete all as specified and directed.
S&F for steel windows fabricated from roll formed sections made of galvanized steel colour coated powder coated (Base steel as per IS-513 D quality galvanized as IS 277 with zinc coating of 120 GSM with total coated thickness of 0.60mm. The coated section shall be with primer coated of primer of -7 microns thick, finish painted with a polyster paint of 12.16 microns thick and back coated with alkyd backer of 5-7 microns or powder coated with pure plyster powder upto 50-60microns thick with the following specifications (a) Main frame 72mm x 55mmx0.58mm (b) Mullion 72mmx50mm x0.58mm(c) Glazed /guazed shutter frame 47mmx20.20mmx0.58mm (d) Glass beads size 12mmx12mmx0.58mm Accessories. Each shutter shall be provided the following fittins (a) Stainless steel pipe of hinges 01 set (b) Alumminium powder coated handle-04 Nos. Glass panes Glazed shutter and fixed glass provided with glass of 5.00mm thick float glass. WIRE MESH -Stainless steel wire mesh of 0.3 mm nominal dia of wire and average width of aperature 1.40mm. Grills window shall be provided with grill made of 10mm square MS bars welded to 12mmx6mm thick MS plate. Distance between bars should not be more than 12cm c/c. Total grill unit shall be enamel painted and fixed to window frame with screw. Note: The glazed/Guaged shutter including guard bars shall be measure once i.e. as per area of opening. No separate payment of separate shutter i.e. glazed and fly proof and guard bars shall be made. Area of shutter shall be the area of opening.
S & F in repair aluminium ventilator with outer frame 40mmx114mm with 1.3mm thickness corner 45 degree cut and aluminium welded center mullion size 40mmx65mm partly glazed/gauzed incl necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading screws, MS wire mesh, 3mm thick sheet glass etc. provision for fixing the exhaust fan complete all as specified and directed.
S & F 5 mm thick glass fixed to frame/ work with complete all as specified and directed.
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples to uPVC windows/ventilators frame complete all as specified and as directed by Engineer-in-Charge
S & F for mild steel, 300 mm ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
S&F 100mm size butt hinges stainless steel of AISI 304 complete all as specified and directed.
S&F 300 mm long, stainless steel of AISI 304 grade, sliding door bolt with hasp, staple (bolt type) and fixing clipss of sheet, cast or extruded sections and fixing bolts and fixed etc complete all as specified and directed.
S&F stainless steel of AISI 304 grade barrel tower bolt 200 mm long, extruded section, etc complete all as specified and directed.
S&F stainless steel of AISI 304 grade handle of size 200mm size long etc. complete all as specified and directed.
S&F Aluminium alloy door seal having rubber strips in bottom, fit to door size complete all as specified
S & F floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor 140mm length.
Dismantling boarding, any description, fixed in any position with nails .
M&L for 18 mm thick wood plastic composites (WPC) board for shutters, 100% solid with density not less than 650 Kg per cubic meter , one side wood grain finished laminated for exposed/external surface , fixed with screws fitted under or above the kitchen cooking platform and/or other platform including all necessary fittings and fixtures like nickle plated clip hinges, knobs, channels etc complete all as specified and directed. Note : (a) Pattern & design of WPC board to be decided by GE. (b) Items like cupboard knobs, stainless steel channel, CP plate clip hinges to be paid in extra. (c) Locking arrangement shall be provided in rooms cupboard shutters. The rate quoted by the tenderer shall be included for the same.
M&L for 18 mm thick wood plastic composites (WPC) board for partitions, 100% solid with density not less than 650 Kg per cubic meter , both side white finished laminated for exposed/external surface , fixed with screws fitted under or above the kitchen cooking platform and/or other platform including all necessary fittings and fixtures like nickle plated clip hinges, knobs, channels etc complete all as specified and directed. Note : (a) Pattern & design of WPC board to be decided by GE. (b) Items like cupboard knobs, stainless steel channel, CP plate clip hinges to be paid in extra. (c) Locking arrangement shall be provided in rooms cupboard shutters. The rate quoted by the tenderer shall be included for the same.
S&F of Stainless steel auto closing hinges openable at 0 degree for kitchen cabinet shutters and bed room cub boards complete all as per specified and directed. Make; ( Hettich, Ebco, Prime )
S&F of stainless steel handles 100 mm size for kitchen cabinet shutters and bed room cub boards complete all as per specified and directed. Make: ( Hettich, Ebco, Prime, Inox )
S&F for PVC magnetic door catches of kitchen cabinet and similar work fixed with MS screws.
S&F SS tower bolt size 125mm complete.
S&F 100 mm long, stainless steel of AISI 304 grade, hasp and staple, safty type, incl bolt to hinge plate and fixed with screws etc. complete all as specified and directed.
S&F, 25mm dia SS curtain rods, 1.2 mm thick, fency type, including SS bracket and SS side bulb decorative type complete for doors and windows as required complete all as specified (Make: As per sample)
Cutting of shrubs/bushes and small plants/vegetation including cutting of trunk n.exc 30cm girth and branches and digging out roots from floor or roofs and walls of up to four storied bldg and making good the dismantled portion in cement mortar 1:3 to match the existing surfaces complete all as specified.
S&F PVC laminated GI wire 2-3 mm dia for cloth drying with S&F fastener as per site requirement complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for
S&F rolled/tubular sections as in main and cross beams, hip and jack rafters; purlins , pillars, trusses , water tank stage , framed guard bars, barred iron doors, ladders, frame balusters, walk ways, railing and similar work where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed
M&L for MS framed work such as grills, gratings, purlin/rafter for shed etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; and similar work con- forming to Fe.290.Gde-E-165 all as specified and directed.
M&L preparing of new steel surfaces of any description not otherwise described, over 10 cm width or girth & applying Two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
S&F pre-painted galvalume aluminium zink coating GI based corrugated steel sheet 0.50mm thick of colour having tensile strength of 550Mpa as in roof covering fixed with self tapping screw all as specified and as directed.
-Blank-
M&L for drilling hole in the existing wall/concrete surface and flush fastner fixed min distance 1.00m each for fastner, polishing, rubbing & including silicon treatment and grouting with CM 1:3 on existing stone on wall and match with existing colour (SS Fastners 100mm long) complete all as specified and directed by Engineer-in-Charge. Note:- The height of building up to 4th storey building, necessary scaffolding rates included in the items.
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thick, including removing rubbish off the premises complete all as specified
M&L cement concrete type B1 1:2:4 (20mm graded aggregate) for plinth protection etc.complete all as specified and directed.
M&L for Rubber moulded colour glosy finish Chequered cement concrete tiles 30 cm x 30 cm x 25 mm thick , set , jointed and pointed in neat cement slurry over and including 15 mm thick screed bed or bedding layers in CM 1:6 for laying floor finishes in floors , path / hard standing etc with grey cement and pigment (Coloured Tiles) complete all as specified and as directed
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified
M&L for pre-polished coloured glosy finished machine pressed precast concrete interlocking paver block any shpe and size confirming to IS 15658-2006 of 60 mm thickness , M-35 grade with grey cement and pigments complete all as specified and directed by Engr in charge.
M&L cement concrete Type B1 , 20mm gded agg 1:2:4 in road kerbs or mud stops, rounded or chamfered on edges , steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height,copings, kneelers, apex stones, bed plates, kerbs not provided . and set in CM 1:6
M&L precast cement concrete solid building blocks or slabs exc 10cm thick Type B1 1:2:4(20mm graded aggregates) (with plain or interlocking joints as directed) setting in mortar, complete, in walls set in CM 1:4
Dismantling of ceiling boards (fibre, pulp, insulation etc.) or insulation bords/ slab/blankets, any thicness, including cover fillets complete all as specified and directed.
S&F False ceiling at all heights with GRG (Glass Fibre With Reinforced Gypsum) false ceiling tiles of perforated of size 595 x 595 mm of approved texture, 12mm thick with perforated micro tegular design and patterns having moisture content less than 2%, humidity resistance edged of 99%, NRC 0.50 to 0.75 as per IS false ceiling GRG false ceiling 8225:1987, Noncombustible as per BS tiles 4 76 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main T runners of size 15 x 32 mm of length 3000mm, cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of s1ze 600x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000 mm length and L shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws etc, complete all as specified, as shown on drgs and directed.
BLANK
Taking down cement or cement lime plaster, any description, on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc complete.
M&L for 10 mm thick rendering on internal surfaces of walls with ready mix plaster self curing (as per Manufacturer’s instructions) on faces of bricks or concrete surfaces, finished even and smooth without using extra cement, complete all as specified and directed. Make : Birla / Ultratech / ACC
M&L for dubbing out average 10 mm thick on irregular face of walls/ Ceiling in cement mortor 1:4, complete all as specified and directed.
M&L for 15 mm thick rendering on external surfaces of walls with ready mix plaster self curing (as per manufacturer’s instructions) on faces of bricks or concrete surfaces, finished even and smooth without using extra cement, complete all as specified and as directed. Make : Birla / Ultratech / ACC
Supply only liquid water proofing compound, complete all as specified & directed.
M&L for 5mm thick rendering on ceiling surfaces with ready mix plaster self curing (as per manufacturer’s instructions) on faces of bricks or concrete surfaces, finished even and smooth without using extra cement, complete all as specified and as directed. Make : Birla / Ultratech / ACC
M&L for preparation of newly plastered surfaces of walls and providing and applying putty of 1 mm thickness over plastered surface to prepare the surface even and smooth and finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm), complete all as specified as directed.
M&L for preparation of old decorated plastered surfaces of walls, complete removal of existing treatment by rubbing , brooming down, washing with water etc and providing and applying plaster of Paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth and finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm,) complete all as specified as directed.
M&L for complete removal of existing treatment and preparation of the old plastered surfaces of walls to prepare the surface even & smooth to receive primer and applying one coat primer and two coats of OBD of approved manufacturer of required shade & colour complete all as specified and directed.
M&L for complete removal of existing treatment and preparation of the old plastered surfaces of ceiling to prepare the surface even & smooth to receive primer and applying one coat primer and two coats of OBD of approved manufacturer of required shade & colour complete all as specified and directed.
M&L for preparation of the new plastered surfaces of walls to prepare the surface even & smooth to receive primer and applying one coat primer and two coats of OBD of approved manufacturer of required shade & colour complete all as specified and directed.
M&L for preparation of the new plastered surfaces of ceiling to prepare the surface even & smooth to receive primer and applying one coat primer and two coats of OBD of approved manufacturer of required shade & colour, complete all as specified and diecred.
Description of Work / Item(s)
Amount
Taking down carefully the old unserviceble Aluminium point wiring (light, fan, socket or power) complete fitting such as switch, ceiling roses, pendants, socket, regulators , all type light Fitting, security light Ding Dong Bell , etc and making good disturbed surfaces of walls including necessary touch up with the adjoining surface of disturbed area ie with OBD/colour wash/white wash as the existing finish, complete all as specified and directed.
M&L for concealed point wiring complete with stranded copper conductor 1.5 Sqmm nominal area single core PVC insulated unsheathed FRLS 1100 volts grade electrical cable drawn through existing concealed PVC conduit in wall and ceiling including replacement of unserviceable pressed steel terminal boxes of min thickness 1.2mm with 120 GSM zinc with modular steel terminal boxes including white cover modular plate with frame suitable for modular switches, modular sockets, modular fan regulators etc of required size complete including 1.5 sqmm single core PVC insulated unsheathed 1100 volts grade copper cable earth continuity wire to common earth and connected to earth dolly complete all as specified and as directed. Notes (i) The rates are inclusive of providing point wiring on casing caping, if there is blockage/damage in existing conduit on ceiling. (ii) The rates are inclusive of cutting / chasing and making good disturbed surfaces with cement mortar 1:3 and applying same finishes with adjoining surfaces of disturbed area with OBD/ Colour wash/ white wash etc as per site requirement.
All as per item Srl item No. 2 here in before but for one light/ ceiling fan/ exhaust fan /bell/ buzzer point controlled by one no, one way 6 Amp switch.
All as per item Srl item No. 2 here in before but one three pin 6 Amp socket outlet point controlled by one no, one way switch on same board.
All as per item Srl item No.2 here in before, but for one three pin socket outlet 6 amps point controlled by one no, one way switch on independent board and through new concealed conduit complete.
All as per item Srl item No. 2 here in before but with using 2.5 sqmm (for phase, neutral) and 2.5 sqmm (for continuous earth wire) cable for one 15/16 amp socket out let point on independent board.
All as per item Srl item No. 2 here in before but for one light point controlled by two nos., two way 6 Amp switches.
All as per item Srl item No.2 here in before, but with using 4.0 sqmm single core cable and 4.0 sqmm single core cable (for continuous earth wire) for independent circuit and through new concealed conduit complete.
S&F Modular Switch 1 way 6A ,1 module complete all as specified and as directed. Make : Havells CAT Part No. AHFSBLW101, Schneider CAT Part No. X1005WH, Legrand CAT Part No.673404.
S&F Switch modular type switch, 6 A 2- way SP switch with finger proof terminal, complete all and specified and directed.
S&F Modular Socket 6A 2/3 pin combined, 2 module complete all as specified and as directed. Make : Legrand CAT Part No.. 573470, Havells Cat Part No. AHFKPXW065, Schneider CAT Part-X2005WH.
S&F Modular Switch 1 way 16A ,1 module complete all as specified and as directed. Make : Legrand CAT Part No- 573410, Havells CAT Part No AHFSXXW161 , Schneider CAT Part No X1101WH.
S&F Modular Socket 6A/16A , 2/3 pin combined, 2 module, complete all as specified and as directed. Make : Legrand CAT Part No.573470, Havells CAT Part No AHFKCXW. Schneider CAT Part No X2106WH
S&F Modular sheet metal enclosure with PVC plat single pole and neutral earth enclosure with a two pin and earth plug and socket with one single pole MCB 20 Amps, 240 Volts, complete all as specified & as directed. Make : Havells CAT Part No DHDMCSN0251026, Indoasian Cat Part 800193, Anchor Cat Part No 98491
S&F Ceiling rose, 6 Amps, 230 volts, AC, ISI marked with three equal size terminals and PVC / Polycarbonate insulated body of 50 x 25mm size, complete all as specified and directed.
Taking Down serviceable and unserviceable LED batten of any type, complete all as specified and directed
Fixing only of serviceable wall mounted LED Integrated Batten 20 Watt - 4Ft , retrieved from Srl item No.10 above after B/R work etc complete including necessary connections of incoming and out going cables, complete all as specified and directed
S&F 20 Watt wall mounted LED batten capable of delivering minimum 2000 lumen having PC diffuser luminous efficiency not less then 120 lumen/Watt CRI>80% PF>0.9,CCT 6500K independent isolated SPMS based constant current electronic LED driver with THD < 10% surge protection and other safety tests as per IS 15885( Part-2/Sec-13) : 2012 polycarbonate diffuser housed in power coated white extruded aluminum channel housing, white colored ABS end caps IP 20 protection input voltage range 140-270V input frequency 50-60Hz including electrical connection with 3 core flexible copper conductor cable of appropriate size from ceiling rose to fixture, complete all as specified and directed. Make - Havells CAT Part No .LUMILINE+BS20WLED830SPCSS, Halonix CAT Part No.HLB-03-20-CW-AL-SQ-HL2, Eveready CAT Pat No- LEDBTA02016-02HE.
S&F 10 Watt wall mounted mirror LED batten capable of delivering minimum 1150 lumen having PC diffuser luminous efficiency not less then 120 lumen/Watt CRI>80%, PF>0.9,CCT 6500K independent isolated SPMS based constant current electronic LED driver with THD < 10% surge protection and other safety tests as per IS 15885( Part-2/Sec-13) : 2012 polycarbonate diffuser housed in power coated white extruded aluminum channel housing , white colored ABS end caps IP 20protection input voltage range 140-270V input frequency 50-60Hz including electrical connection with 3 core flexible Cooper Conductor cable of Appropriate size from ceiling rose to the fixture, complete all as specified and directed. Make : Havells CAT Part No .LUMILINE+BS10WLED865SPCSS, Halonix CAT Part No.HLB-03-20-CW-AL-SQ-HL2, Eveready CAT Pat No- LEDBTA01010HE.
S&F Recessed/ surface mounting 36 watt 2' x 2' flat LED panel fitting with soft light and glare free symmetrical illumination suitable for RCC/POP ceiling supplied with wedge bracket to fix in existing ceiling in replacement of existing old unserviceable CFL fitting any type from ceiling of common areas and making good disturbed surface/POP ceiling to match and getting electrically connected the fitting with switch board for suitable size of PVC copper wire, complete all as specified and directed. (For MESS). Make : Philips, Bajaj, Eveready.
S&F 20 Watt security light high efficiency long life LED module with SMD LED package mounted on MCPCB with high LED efficiency of 2600 Lumen/Watt integral SMPS based constant current electronic LED driver with THD<10% surge voltage protection and other safety tests as per IS:15885( part-2/sec-13),IP 66 protection high efficiency polycarbonate cover with integrated lens housed in pressure die cast aluminim alloy heat shrink for effective thermal management strudiness excellent corrosion resistance separate optical and control gear compartment & top opening for easy maintanance suitable for side entry wall mounting with bracket arm OD 35mm to 42 mm including necessary electrical connection to the fixture with 3 core flexible copper cunductor cable of appropriate size and 1.5m long bracket having 40mm diameter light grade GI pipe including GI clamp nuts bolts & washers with two coats of synthetic enemal paint over a coat of oxide primer, complete all as specified and directed
Supply, installation, testing and commissioning of 1200mm sweep BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, Class of insulation : B, power factor not less than 0.9, service value (CMM/W) minimum 6.85, not less than 350 RPM (tolerance as per IS:374-2019), THD less than 10%, including remote control unit for speed control and all remaining accessories including safety pin, nuts bolts, washers, temperature rise =75 degree C (maximum), insulation resistance more than 2 mega Ohm, suitable for 230V, 50 Hz, single phase AC supply, complete all as specified and directed.
Taking down carefully unserviceable main switches, distribution boards of any type/size from their position including making good to disturbed surfaces of wall etc, complete all as specified & directed.
S&F factory made epoxy polyester powder coated distribution board TP&N 4 way (VTPN MCCB DB) with metal double door (IP-43 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed on wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates, conforming to IS: 8623 alongwith cable end box for above DB, complete all as specified and directed. Notes : (a) MCBs & MCCBs shall be measured and paid for separately. (b) All cables terminating into MCBs/MCCBs shall be connected by using suitable copper lugs/ thimbles/ sleeves and its cost shall be deemed to be included under respective item of Sch. (c) Make of DBs and MCBs/MCCBs shall be same.
S&F Sheet metal enclosure distribution board, single pole and neutral, AC, 240 volts, 12 way with 200 Amps rated copper bus bar and sheet metal enclosure double door with rubber gasket type with IP - 43 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing, complete all as specified and directed. Notes - (a) MCB shall be measured and paid separately under respectively item. (b) Make for the DB/MCB/MCCB shall be same.)
S&F Sheet metal enclosure distribution board, single pole and neutral, AC, 240 volts, 08 way with 200 Amps rated copper bus bar and sheet metal enclosure double door with rubber gasket type with IP - 43 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing, complete all as specified and directed. Notes - (a) MCB shall be measured and paid separately under respectively item. (b) Make for the DB/MCB/MCCB shall be same.)
Taking down MCB of any type, complete all as specified and directed.
S&F MCCB 63 Amps 4P, 415 Volts with 16 KA including electrical connection with incomer with appropriate size of aluminium lugs and insulation packing, complete with connection, testing and commissioning by using suitable copper lugs, complete all as specified and directed.
S&F MCB SPN 'B' curve 63 Amps 240 Volts , 10 KA, complete with connection, testing and commissioning by using suitable copper lugs, complete all as specified and directed.
S&F MCB SPN 'B' curve 40 Amps 240 Volts, 10 KA, complete with connection, testing and commissioning by using suitable copper lugs, complete all as specified and directed.
S&F MCB SP 'B' curve 06 to 32 Amps 240 Volts 10 KA, complete with connection, testing and commissioning by using suitable copper lugs, complete all as specified and directed.
M&L for Earthing complete with galvanised steel earth plate electrode 60cm×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part-1 2009, connected to earthing test point, earth lead protected by medium grade 15 mm dia GI pipe connected to main control board and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC 1:2:4 type B-1 including excavation and earth work, disposal of surplus soil to a distance not exc. 50 Mtrs, complete all as shown on electrical plate No 3 of SSR Part-1 2009. Notes :- (a). PCC pit shall be provided at least 500 mm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipe and fittings, junction, elbow etc shall be deemed to be included in the unit rate. (b). RCC pit cover shall be of pre-cast RCC 1:2:4, type B-1, 80 mm thick reinforced with XPM weighing not less than 4 Kg/ Sq m in lieu of cast iron cover all as specified or indicated including testing on completion all as specified and directed.
S&F Earth continuity conductor or main earthing lead fixed on wall/ceiling in batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed on poles or any other indicated situation for loop earthing etc as required 4mm dia galvanised iron or steel wire, complete all as specified and directed.
Taking down carefully existing sub main wiring with aluminium conductor/copper conductor cable of any size with GI earth wire including wooden batten etc and making good disturbed surface of walls etc, complete all as specified & directed.
S&F Submain wiring alongwith earth wire with 5 run of 10 Sqmm (03 run for phase and 01 run for neutral) and one run of 10 Sqmm as earth wire of FRLS PVC insulated copper conductor, single core cable drawn through existing rigid PVC conduit of 20 mm bore with all fittings accessories, complete all as specified & directed.
S&F Submain wiring alongwith earth wire with 3 run of 6 Sqmm (01 run for phase and 01 run for neutral) and one run of 6 Sqmm as earth wire of FRLS PVC insulated copper conductor, single core cable drawn through existing rigid PVC conduit of 15 mm bore with all fittings accessories, complete all as specified & directed.
S&F Electric water heater, storage type with glass lined SS inner tank and copper heating element up to 2 KW capacity 25 liter, BEE 5 Star rated with all accessories such as safety valve, thermostat, NRV, etc complete all as specified and directed. Make : Havells, Bajaj, Crompton.
S&F PVC connection with brass nipple 15 mm x 600 mm long with ISI marked suitable for hot and cold water of 25 ltrs capacity of geyser as hot and cold water connection, complete all as specified and directed.
S&F Exhaust fan, Metal body AC single Phase. 230V of size 450mm sweep with, blades, and frame and louvers including taking down of old Exhaust fan and deposit it to MES store yard for safe custody, complete all as specified and directed.
S&F Exhaust fan made of sturdy engineering plastic complete with including taking down old exhaust Fan and deposit it MES store yard louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm, complete all as specified and directed.
M&L for opening of hole throughout the wall, suitable for exhaust fan of size up to 450 mm and fixing of nuts, bolts with anchor fasteners of suitable size and making good to disturbed surfaces as per existing, complete all as specified and as directed.
Supplying, laying, jointing, testing and connecting of XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armored, electric power cable (heavy duty) with multistranded aluminum conductors, IS:7098 marked, suitable for LT 1100 Volt system of size 120 Sqmm, 3.5 core, laid in trenches fixed to pole, including making connection in existing LT panel, complete all as specified & directed. Note :- Excavation, earth work, cable protection, sand fillings, cable joint shall be measured and paid for separately under respective items of this Schedule.
Excavation in trenches not exc. 1.5m wide and not exc. 1.5m deep in soft/loose soil for laying of underground cable, foundation of poles & stays etc., and getting out, complete all as specified & directed.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specifed & directed.
Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified & directed.
Supply and laying double wall corrugated (DWC) pipe of 50 mm size,laid in trenches including all connecting necessary items, complete all as specified and directed.
Taking out carefully LT under ground cable of any sizes and descriptiion from trenches, complete all as specified & directed.
S&F LED batten 20W, CCT 6500K work on motion sensor technology that detects the presence of a person through a smart, built in occupancy sensor. It provides 100% light at 20w during occupancy and delivers pleasant light of 30% during zero occupancy, complete all as specified and directed. Make : Eveready CAT Pat No. 6BP1T08FM20 Trio Led Batten, Philips, Bajaj CAT Part No BCLAB 20W LED P S
Supplying, installing, testing & commissioning Solar of water heating system glass lined (Evaculated Tube collector) to raise water temperature upto 60-70 degree celcius on clear sunny day with 1000 LPD hot water stainless steel tank as per IS-12933 and IS 12976 as approved by MNRE with heat exchanger SS-304, 1000 Ltrs tank with 100mm insulation, collector structure, system piping (insulated Rockwool insulation 100mm Al sheet cladding 24 SWG) including electrical backup of 3 KW electrical heating elements - 04 Nos with all fittings/accessories, angle iron of size (60x60x6mm) support for mounting of Hot water tank and angle iron of size (30x30x4mm) support for mounting Flat plate collector including necessary fabrication, welding work etc complete with nuts bolts and washers and applying painting with two coats of synthetic enamel paint over a one coat of red oxide zinc chrome primer for mounting of hot water tank, complete all as specified and directed.
S&F Rotational moulded polyethylene three layer water storage tank of capacity 1000 Liters (Cylindrical vertical with closed top) hoisted and fixed in position, complete all as specified and directed.
S&F 3- layer PP- R polypropylene random copolymer concealed pipes having inner dia 25mm SDR 7.4 (PN 16) UV stabilized and anti microbial fusion welded having thermal stability for hot and cold water supply including all PP-R plain and brass threaded polyproline random fittings fixed including Nitrile insulation 13MM thickness and Hardener Paint for Hot water trunk line to walls, ceilings or in floors including all fittings etc as required, complete all as specified and as directed.
S&F 3- layer PP- R polypropylene random copolymer concealed pipes having inner dia 20mm SDR 7.4 (PN 16) UV stabilized and anti microbial fusion welded having thermal stability for hot and cold water supply including all PP-R plain and brass threaded polyproline random fittings fixed including Nitrile insulation 13MM thickness and Hardener Paint to walls, ceilings or in floors including all fittings etc as required, complete all as specified and as directed.
M&L for making connection of PP-R distribution branch with PP-R main of size 20mm by providing and fixing tee including cutting and making fusion joint etc, complete all as specified and directed.
M&L for cutting existing tubing and inserting new reducer Tee of suitable size including necessary screwing threading, tail pieces, short pieces, jointing material etc, complete all as specified and directed.
S&F Galvanized steel water tubing medium grade with all fittings such as elbow, unions, nipples, tees, bends, short pieces, connectors, back-nuts, caps, plugs, diminishing pieces and sockets etc as per site requirement upto 25mm dia bore, complete all as specified and directed.
S&F PP-R Gate valves(brass insert) as per site requirement, suitable for 20mm bore pipe, screwed both side ends for 3-Layer PP-R pipe, complete all as specified and as directed.
S&F Gun metal globe or gate valve with iron wheel head, complete suitable for 25mm bore pipe, screwed both side ends for GI pipe or unions and fixed of size 25mm bore, complete all as specified and as directed.
S&F Ball valves high pressure of PTMT with epoxy coated aluminum rod & high density plastic ball screwed for iron pipe and fixed of 25mm bore size, complete all as specified and as directed.
S&F Bib tap, cast copper alloy chromium plated of size 20mm dia with crutch or butter fly handle, screwed down , screwed for iron pipe including reducer socket etc, complete all as specified and directed.
S&F Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. not exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 including painting with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer for mounting of water tank and similar work etc, complete all as specified and directed.
M&L for cement concrete in foundation filling and mass concrete, type B-2, 1:2:4 using 40 mm graded crushed stone aggregate, complete all as specified and directed.
S&F Sheet metal plug & socket enclosure with one MCB SP 20Amps, 240 V, complete all as specified and as directed.
M&L for submain wiring along with earth wire in PVC Caping & casing with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed as required of size 2x4 sqmm + 1x4 sqmm earth wire, complete all as specified and as directed.
S&F Fire Alarm Sounders / Sirens Electronic type horizontal single stage continuous normal operation for at least 50 minutes with sound level 65 DB to 120 DB measured at 1.5 Mtr with sound output variation of + 5 DB 500 mtr Range, complete all as specified and as directed.
S&F Addressable manual call point break glass type with alarm LED, complete all as specified and as directed.
A R construction (BID ID -3278721)
M/S Chhavi Constructions Co (BID ID -3282947)
Commercial Traders (BID ID -3279248)
L G BUILDERS (BID ID -3278572)
M/s Innovative Coolings and Constructions (BID ID -3279135)
The new hut furnitures (BID ID -3279141)
M/S Parshant Associates (BID ID -3283074)
ANANYA ENTERPRISES (BID ID -3276949)
M/S Parshant Associates (BID ID -3283074)
The new hut furnitures (BID ID -3279141)
L G BUILDERS (BID ID -3278572)
Commercial Traders (BID ID -3279248)
M/S Chhavi Constructions Co (BID ID -3282947)
VED PRAKASH ARORA (BID ID -3279077)
M/s Innovative Coolings and Constructions (BID ID -3279135)
ANANYA ENTERPRISES (BID ID -3276949)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .