| 1 | L1₹27.1 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹29.9 L+₹2.2 L (7.97%)Rejected-Finance AT ROAD SANTIPUR GUWAHATI 781009 ASSAM | GUWAHATI | KAMRUP METRO | ASSAM | 781009 | L2 | Rejected-Finance Other than Lowest Bidder | |
| 3 | L3₹30.8 L+₹3.1 L (11.2%)Rejected-Finance HOUSE NO 2 SATGAON MAIN ROAD NEAR BAILEY WATER FACTORY P O UDAYAN VIHAR DIST KAMRUP METRO GUWAHATI ASSAM 781171 | GUWAHATI | KAMRUP METRO | ASSAM | 781171 | L3 | Rejected-Finance Other than Lowest Bidder | |
| 4 | L4₹30.9 L+₹3.2 L (11.6%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest Bidder | |
| 5 | L5₹36.1 L+₹8.5 L (30.7%)Rejected-Finance 30 1 PULIN KHATICK ROAD TANGRA TANGRA KOLKATA WEST BENGAL 700015 | KOLKATA | WEST BENGAL | 700015 | L5 | Rejected-Finance Other than Lowest Bidder |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
26 Jul 2021, 6:00 pmClosed
GE NARANGI
GE Narangi C/O 99 APO Guwahati
CERTAIN MISC BR EM REPAIRS TO MD ACCN IN PHASE II JINTU VIHAR AND ROOF TREATMENT TO MD ACCN WITH ALLIED WORKS IN THE AOR OF AGE BR II UNDER GE NARANGI.
2021_MES_455346_1
8655/B/E8
Open Tender
Civil Works
Item Rate
180 days
GE NARANGI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE NARANGI
₹70,000
Yes
17 Aug 2021
28 Jun 2021
29 Jul 2021
28 Jun 2021
26 Jul 2021
12 Jul 2021
Amount
Demolition of brick /stone massonry work built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
M&L brick work with sub class ‘B’ bricks (locally available best quality) straight or curved on plan exceeding 6m mean radius built in cement mortar (1:6) complete all as specified and directed.
All as per item No. 2 above but except bricks. ( Serviceable bricks obtained from demolition shall be reused).
M&L for brick work with subclass ‘B’ bricks, (locally available best quality) straight or curved on plan to any radius in half brick thick wall, built in cement mortar (1:4) complete all as specified and directed.
Demolition of plain cement concrete (Un-reinforced) in ground floors and paving n exc 15cm thickness (below or above ground level) including removal of spoils/ demolished materials not exceeding 50m and depositing complete all as specified and directed.
M&L for 40mm thick PCC type B-1, 1:2:4 (20mm graded stone aggregate) as in flooring,and finishing the surface even and smooth with using extra cement complete all as specified and directed.
M&L for 75 mm thick PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in sub base complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as directed.
M&L for applying two coat @1.5 kg/sqm per coat minimum of two components of water proofing tretment on RCC roof/wall/sunken floor of plastered surface with Nito proof 100 as priming coat and Nito proof 120 or 100 as finishing coat of Fosroc or equivalent as approved complete all as specified and directed..
M&L for 40mm dia GI spout medium grade 40cm long fixed in top of sunken slabs including cutting hole to wall and making good with CM 1:2 etc. complete all as specified and directed.
M&L for PCC 1:5:10 type E2 (using 40mm graded stone aggregate) as in filling/mass concrete in sunken floor complete all as specified and directed.
M & L for 25 mm thick plain cement concrete, 1:2:4, type B0 using 12.5 mm graded stone aggregate on roof surfaces, chajjas and finished the exposed surfaces fair and even including form work if any complete all as specified and directed.
M&L for plain cement concrete 1:2:4, type B-1, using 20 mm graded stone aggregate as in benching, coping, haunching between roof and wall or parapet wall, between chajja and wall etc, finishing the exposed surface of concrete even & fair . including all necessary form work all as specified and as directed.
M & L for water proofing treatment to RCC roof slab, including parapet comprising with the following of treatment/specification from bottom to top:- (i) Taking out old roof treatment and roughening the concrete roof surfaces by picking, sweeping clean and washing down with water to remove dust etc and disposal of rubbish not exceeding 100 mtr distance from starting point. (ii) Screed bed or bedding layer of mortar 15 mm thick in CM 1:4 mixed with water ptoofing compound @ 3% of weight of cement or as per manufactures instructions and surface finished even and smooth without using extra cement after applying a coat of cement slurry @ 3 kg/sqm for laying APP membrane. (iii) Cleaning of plastered roof surface and applying one coat of cold bituminous primer @ 0.25ltr /Sqm conforming to IS:3384-1986. (iv) APP based polymeric membrane 3mm thick (minimum), weighing 3.5 Kg/sqm reinforced with polyester non woven fabric (weighing not less than 160 gms/Sqm) shall be applied over bituminous primer as specified above over by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction. (v) Applying two coat of aluminium paint over the APP modified membrane @ 0.11Kg/sqm. Note: Water proofing compount will be measured & paint seperatly.
Taking down chowkats or frame with shutters (without taking off shutters from frame) each not exceeding 1.50 Sqm complete all as specified and directed.
Taking down chowkats or frames exceeding 1.5 Sqm but not exceeding 4 Sqm each (without taking off shutters from frame) complete all as specified and directed.
Taking down shutter of any description exc 1 Sqm but n exc 2 Sqm each complete all as specified and directed.
Taking down shutter of any description n exc 1 Sqm each complete all as specified and as directed.
Taking down shutter of any description exc 1 Sqm n exc 2 Sqm each and refixing in the same opening. complete all as specified and as directed.
M&L for 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and directed.
M&L for 1.25mm thick mild steel pressed steel frames of size 105x60mm for doors with single rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and directed.
M&L for 1.25mm thick mild steel pressed steel frames of size 125x60mm for doors with single rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and directed.
M&L for PCC 1:3:6 type C0 (using 12.5mm graded stone aggregate) as in filling the hollow portion of steel frame complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in fixing of hold fast or bed block complete all as specified and directed.
S&F 30mm thick flush shutter, solid core construction with particle board core and plywood face panel, commercial type on both side complete all as specified and directed.
S&F 35mm thick second class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauge etc with plain, chamfered or rounded, mitred beads (without sash bars) for securing glass etc, sizes of members of shutters all as specified in SSR part-I section 8 clause 8.24 (a) complete all as specified and directed.
S&F 30mm thick second class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauge etc with plain, chamfered or rounded, mitred beads (with sash bars) for securing glass etc, sizes of members of shutters all as specified in SSR part-I section 8 clause 8.24 (b) complete all as specified and directed.
S&F factory made solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with mild steel square tube complete all as specified and directed.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tube for top and bottom rails, MS frames shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stills and plain colour PVC sheet top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, paneling of plain colour PVC sheet to be fitted in the MS frame welded/ scaled to the stiles and rails with suitable PVC Sheet beading and jointed together with solvent cement as per drawings and specifications as catered in SSR Part – II 2004 complete all as specified and directed.
S&F cold rolled mild steel butt hinges 100 mm long medium weight complete all as specified and as directed.
S&F cold rolled mild steel butt hinges 75 mm long medium weight complete all as specified and as directed.
S&F 150mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
S&F 100 mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and as directed.
S&F 150mm size aluminium handles, cast type, anodised complete all as specified and directed.
S&F 100 mm size aluminium handles, cast type, anodised complete all as specified and as directed.
S&F aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolt of extruded section or cast aluminium alloy and fixed 300mm long complete all as specified and directed
S&F steel helical door spring 300mm ordinary rat tail rod pattern springs including roller plate complete all as specified and as directed.
M&L for MS bands, straps, supports or stays for pintle hinge, hand made sliding bolts, hold fast etc conforming to Fe-290 Gde-E-165 complete all as specified and directed
S & F stain less steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed.
S & F in repairs Statin-less steel wire cloth, 0.36 mm dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as directed.
S&F for Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe 290, Gde-E-165 completed all as specified and directed.
Dismantling floor, hearth and wall tiling including cement mortar bedding (but excluding backing), removing rubbish off the premises complete all as directed.
M&L for coloured Non-skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed or bedding layers in cement mortar (1:4) complete all as specified and directed.
M&L for glazed ceramic coloured tiles 300mmx200mmx7mm thick, set and jointed in neat cement slurry and pointed in coloured cement as in vertical surfaces such as skirting, dados and risers to steps etc to match including 10 mm thick screed bed or bedding layers in CM (1:4) complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thick ness in floors aprons etc laid beded and pointed in any mortar complete all as specified and as directed.
M&L for Granite work 20mm thick (table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms and like with and including 15mm bedding in CM 1:6 and pointing in white cement (1:2) using marble dust with admixture of pigment to match the colour of tiles etc complete all as specified and directed.
Taking down cement plaster on walls, chajja surfaces, etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
M&L for 15mm thick rendering in cement mortar (1:4), in two layers, to fair faces of brick or concrete wall surfaces, top layer 5 mm thick mixed with water proofing compound (@ 3% by weight of cement or as per manufacture's instructions), finished even and smooth without using extra cement complete all as specifed and directed. (Note : Water proofing compound will be measured and paid separately as "Supply only")
M&L for rendering 10 mm thick in CM (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed
M&L for rendering 5 mm thick in cement mortar (1:3) as in ceiling surface finished even and smooth without using extra cement complete all as specified and directed
M&L for preparation of new wood or wood based surface of any description exceeding 10 cm width or girth and applying two coats of synthetic enamel paints over a coat of pink primer complete all as specified and as directed
M&L for preparation of new steel or iron surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paints over a coat of red oxide, zinc chrome primer complete all as specified and as directed.
Supply only integral water proofing compound of approved make complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of wall and applying three coats of white wash complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
Hacking out old broken glass of any thickness, size quality or description from wooden frames glazed with putty or fixed with bead complete all as directed.
S&F 3mm thick sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.50sqm in each pane complete all as specified and directed.
S&F 3mm thick frosted glass, ordinary quality and glazing with oil putty in square not exceeding 0.50sqm in each pane complete all as specified and directed.
M&L for complete removal of old treated surfaces on walls and applying one coat of alkali resistant primer and a coat of wall care putty, sanding the surfaces till smooth finish is obtained and finally applying two coats of oil emulsion distemper etc complete all as specified and directed.
Taking up or down 15 mm bore GI water tubing and connections including cleaning for re-fixing to store complete all as specified and as directed.
S & F GI tubing15 mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
Refixing only old serviceable 15 mm bore Steel tubing and connections as obtained from taking up/down old steel tubing including provision of new fittings in new or old position to walls,ceiling, flooring etc. complete all as specified and as directed.
Taking up or down 20 mm bore GI water tubing and connections including cleaning for re-fixing to store complete all as specified and as directed.
S & F GI tubing 20 mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
Refixing only old serviceable 20 mm bore Steel tubing and connections as obtained from taking up/down old steel tubing including provision of new fittings in new or old position to walls,ceiling, flooring etc. complete all as specified and as directed.
S&F in repair Bip tap fancy type 15mm bore standard of PTMT any colour screwed for iron pipe & fixed complete all as specified and directed.
S&F in repairs Bib taps 15mm dia cast copper alloy chromium plated, fancy type with crutch or butter fly handles screwed down for iron pipe or for brass ferrule complete all as specified and directed.
S&F in repair angle stop cock, fancy type, chromium plated with long shank and cup, cast copper alloy, with capstan head, screwed down, screwed for iron pipes or brass ferrule, 15 mm bore, complete all as specified and directed.
S&F in repair Stop valves 15 mm bore fancy type, CP with long shank & cup (conncelaed type), cast copper alloy screwed down high presure, with crutch of butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F in repair 125 mm dia chromium plated swivel type shower rose with 190 mm long chromium plated shower arm and wall flange suitable for fixing 15 mm bore iron pipecomplete all as specified and directed.
S&F in repairs fancy type Brass chromium plated 600mm long Towel Rail fixed with screws and wooden/plastic cleats etc. complete all as specified and directed.
S & F 500 litres capacity rotational moulded polye-thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I with and including 20mm bore dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed etc including dismantling of old tank of any description complete all as specified and directed.
S & F 1000 litres capacity rotational moulded polye-thylene water storage tanks triple layer ISI marked (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I with and including 20 mm bore dia -ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed etc including dismantling of old tank of any description . complete all as specified and directed.
S&F in repair vitreous china wash basin white flat back size 550 mm x 400mm including all fittings including cutting for and pinning in ends of brackets or erecting stand etc complete (waste coupling 32mm bore CP, 32mm bore PVC waste pipe, cast iron brackets etc shall be deemed to be included in the quoted rate) complete all as specified and directed.
S&F in repairs 15mm bore pillar taps cast copper alloy with capstan heads chromium plated screwed down high pressure with or without lettered 'HOT' or 'COLD' with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and directed.
S&F in repairs 15mm bore pillar taps fancy type cast copper alloy with capstan heads chromium plated screwed down high pressure with or without lettered 'HOT' or 'COLD' with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and directed.
S&F in repairs 15 mm dia 450 mm long PVC connection pipe with two PVC PTMT nuts at each ends with rubber washer complete all as specified and directed.
S&F in repairs vitreous china wash down water closet (padestal pattern) including connection to drain (or outgoing pipe) and flushing pipe, anti syphonage pipe, trap set and including white or black seat cover for padestal pan with mild steel chromium plated aluminium hinging device, fixed to pan with suitable screws etc complete all as specified and as directed.
S&F in repairs viterous china squatting pan Orissa pattern size 580 x 440mm white with integral foot rest, but excluding flushing cistern but including 'P' or 'S' trap and provision of lime concrete bedding complete all as specified.
S&F in repairs grating doom 125mm dia with waste hole of PTMT (Min weight 25 gms) complete all as specified and directed.
S&F in repair Grating doom 100 mm dia of PTMT (min. weight 25 gms) complete all as specified and directed.
S&F in repair waste coupling PTMT suitable for wash hand basins, with long screwed shanks and fly nuts of size 32mm complete all as specified and directed.
S&F in repair waste coupling suitable for stainless steel Sink, with long screwed shanks and fly nuts of size 40mm complete all as specified and directed.
S&F in repair PVC waste Pipe of size 32 mm for WHB complete all as specified and directed.
S&F in repair PVC waste Pipe of size 40 mm for Sink complete all as specified and directed.
S&F in repairs plastic water closet seat cover white, closed pattern with flat bottom,and cover &milld steel chromium plated or aluminium hinging device complete all as specified and directed.
S&F in repairs Stainless Steel Sink with drainage board made out of 1.00mm thick sheet with plug washers( including waste coupling brass chromium plated suitable for Sink, with long screwed shanks and fly nuts of size 40 mm, PVC waste pipe) MS angles cantilever brackets of suitable size and connecting union to pipe of over all size 915x460mm and bowl size 410x330x160mm complete all as specified and directed.
S&F in repairs PVC low level flushing cistern 10 litres capacity with inlet ball valve, float and handles including brackets complete all as specified and directed.
Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes exc 500 & n.exc 1000 ltr capacity, etc complete all as directed.
Disconnecting existing water tanks, of any description and of capacity exc 250 litres and not exc 500 litres setting aside (or lowering if required) for repairs, cleaning, etc. and hositing if required reconnecting and re-fixing in position including 20mm bore dia ball brass valve high presure with polythene float and flynut complete screwed for iron pipe or brass ferrule and fixed etc complete all as specified and as directed.
Grubbing up tree trunk including cutting of trunk portion, girth of tree not exc 30 cm, protruding over ground / building / wall / root / chajja / stack pipes etc. digging out roots, and applying root killer chemical as per manufacturer's instructions, filling holes with cement mortar (1:4) or PCC 1:2:4 type B-0 and removing the unserviceable materials from the site complete all as specified and directed.
Taking down carefully aluminium/ copper point wiring for light/fan/ socket/bell or power point incl. All fittings i.e. switch, sockets, ceiling rose, regulators, batten holders, etc. complete removing materials to store for keeping in safe custody site or handed over to contractor as schedule of credit and making good disturbed surfaces of walls, floors, etc complete all as directed by Engineer-in-Charge.
Point wiring with PVC insulated and unsheathed cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts, FRLS grade cable conforming to IS-694 1990 drawn in and including PVC Casing and Caping with all accessories including fabricated MS terminal boxes fixed flush with wall surface with 3mm thick masonite laminated sheet top cover fixed with brass screw for mounting switches, sockets, regulator etc including 1.5 sqmm single core PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for One light or fan point controlled by one 5 Amps switch one way complete all as directed..
All as per item No 96 here-in-before but for One light point controlled by 2- two way 5 Amps switch
All as per item No 96 here-in-before but for One 3 pin 5 Amp switch socket outlet on independent board
All as per item serial No 96 here-in-before but for One 3 pin 5 Amp socket outlet on same board with other switches.
All as per item serial No 96 here-in-before but for One bell point controlled by one switch 5 Amps bell push.
All as per item No 96 here-in-before but wiring with 2.5 sqmm size single core multistranded copper conductor cable for 6 pin 15 Amps switch socket combination outlet on independent board with 2.5 sqmm PVC insulated and unsheathed copper conductor as earth and connected to earth dolly.
M&L point wiring with PVC insulated and unsheathed cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts, FRLS grade cable conforming to IS-694 1990 drawn in concealed conduit including 1.5 sqmm single core PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for One light or fan point controlled by one 5 Amps switch one way complete all as specified and directed.
All same as per item No 102 here-in-before but for One light point controlled by one 5 Amps switch two way.
All same as per item No 102 here-in-before but for One 3 pin 5 Amp switch socket outlet on independent board.
All same as per item No 102 here-in-before but for One 3 pin 5 Amp switch socket outlet on same board with other switches.
Same as per item No 102 here-in-before but for One bell point controlled by one switch 5 Amps bell push.
All same as per item No 102 here-in-before but wiring with 2.5 sqmm size single core multistranded copper conductor cable for 6 pin 15 Amps switch socket combination outlet on independent board with 2.5 sqmm PVC insulated and unsheathed copper conductor as earth and connected to earth dolly.
S&F switch piano, flush type single pole one way 5 Amps 230 volt complete all as directed.
S&F switch piano, flush type single pole two way 5 Amps 230 volt complete all as directed.
S&F bell push, flush type, 5 Amps complete all as directed
S&F socket outlet 3 pin, 2-in-1, 5 Amps flush type complete all as directed.
S&F switch socket combination outlet 5 pin, 2-in-1, 5 Amp flush type complete all as directed.
S&F switch socket combination multipurpose, 2 in 1, 6 pin, 5 & 15 Amp flush type complete all as directed. .
S&F ceiling rose surface bakelite 65x50mm three terminal complete all as directed.
S&F bell ding-dong, electric, 230 volt, single phase complete all as directed.
S&F lamp holder insulated PVC/ Polycarbonate/ bakelite body, with back plate suitable for batten fitting or PVC round or squre box, complete all as directed
S&F stepped type electronic fan regulator, two module size, flush type complete all as directed.
M&L for Sub main wiring with 2 runs of 4.0 sqmm, single core, FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 4.0 sqmm single core FR-LSH PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. (Note: 2 run of 4 Sqmm cable and 1 run of 4 Sqmm cable along with conduit altogether shall be measured as one unit.)
M&L for Sub main wiring with 2 runs of 6.0 sqmm, single core, FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 6.0 sqmm single core FR-LSH PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. (Note: 2 run of 6 Sqmm cable and 1 run of 6 Sqmm cable along with conduit altogether shall be measured as one unit.)
Supply, installing, connecting and testing AC single phase static energy meter of Accuracy class 1.0, 240V,50Hz with backlit LCD display,of rating 10 to 60 Amp(Measure and displays in kWhV,I,kW,PF Last month history of kWh & Md in kW) with special features like TOD, Tamper logging,Optical communication port & display in absence of power with transparent hinge type box including taking down old metre and depositing the same in MES store yard of AGE E/M complete all as specified and directed. (Make- HPL/L&T/SECURE .)
S&F in repairs wall mounted decorative luminaire in design mesh suitable for 9W LED lamp B22 base ,including lamp of 9watt .Complete as directed as specified . (Make -Havells, cat no-LHDL07150099 or equivalent of Bajaj/ Philips /GE/Crompton)
S&F in repair regal batten for LED Tube rod pre-wired including LED tube double sided 1x20W connecting up with aluminium housing and sheathed 1100 volt grade flexible copper cable & fix on 2 no. of PVC block complete all as directed. (Make:- Havells, Model-REGALBATTENT8UPTO1X22WDSBSWH+CRSTAL1213T8DSTL20WLED865SGLASS or equivalent model of make Bajaj/ Philips /GE/Crompton)
S&F in repairs LED box type fitting pre-wired including LED tube 1x10W connecting up with PVC insulated and sheathed 1100 volt grade flexible copper cable and fix on 2 no of PVC block complete all as directed. Make:- Jaguar Model-LGLZ01X010XC/ LGLZ01X010XN/LGLZ01X010XW or Make:- Havells Model-LUMILINEPLUSBS10WLED865SPCSS or equivalent model of make Philips /GE/Cromptonor equivalent model of make Philips /GE/Crompton
S&F in repairs LED (double sided connection) ) ultra bright polycarbonate tube light 18/20 watt retrofit in existing flourescent tube light . Make Havells/crompton/Bajaj/Jaquar or euivalent.
Dismantling old electric kWH meters carefully by disconnecting all electric connection and re-fixing after necessary repair of electric energy KWH meter single phase 05 to 60 Amps, including making connection of incomming and outgoing wiring circuits and submission of KWH reading details of old unserviceable taken down meter complete all as directed.
M&L for frabricationg angle iron frame of size 18 inch x 24 inch using 30x30x5mm angle iron firmly grouted in wall surface using support and fixing 6mm thick flameproof Hylem sheet of size 19 inch x 25 inch on top for mounting 4 Nos electric energy meters single phase, including making good to damaged surface as per existing and making necessary electrical connection using 6.0 sqmm single core copper multistranded cable through PVC conduit from MCB DB box to incomming of meter and outgoing connection of submain circuit wiring complete all as directed. (Note : Quoted rate includes making all incoming and outgoing electrical connections using PVC insulated mulitstranded copper conductor wire of size 6.0 sqmm through PVC conduit pipe in gray color from MCB DB to Electric meters.)
S&F in repairs fan bearing of size 6201/6202 suitable for ceiling fan 1200/1400mm sweep complete all as directed.
Taking out existing unserviceable switch board plates any type, dismantling switches carefully, stacking at site for use of serviceable switches and supply and fixing new 3mm thick masonite laminated sheet top cover fixed on 6 inch x 10 inch MS box with brass screw for mounting switches, sockets, regulator etc including making necessary electrical connection with 1.5 sqmm single core copper mulitstranded cable all as directed at site by Engineer-in-charge. (Note : New Switches, sockets, fan regulators etc if required will be measured and paid separately under relevant items).
Taking out existing unserviceable switch board plates any type, dismantling switches carefully, stacking at site for use of serviceable switches and supply and fixing new 3mm thick masonite laminated sheet top cover white or ivory fixed on 4 inch x 8 inch MS box with brass screw for mounting switches, sockets, regulator etc including making necessary electrical connection with 1.5 sqmm single core copper mulitstranded cable all as directed at site by Engineer-in-charge.
S&F in repairs decorative hexagonal bulk head LED luminaire 10Watt,6000K with IP 66 Protection (Make Havells Model HEXAFT10WLED857SSYMBOPC or equivalent of Bajaj/ Philips /GE/Crompton)
M&L for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 m deep below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI earth lead wire 4 mm dia or 8 SWG bolted (with GI nuts, bolts & check nuts) and earth plate electrode at one end and connected to main switch board/ DBs etc. at the other, earth strip encased(protected) in and including 15 mm bore GI pipe medium grade with all fittings from top of electrode to main switch board/ DBs etc fixed with and including 25 x 6mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-2 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work complete all as specified and shown in electrical plate No 3 of SSR Pt-I including demolition of old earthing complete all as specified and directed..
Taking down ceiling fans 1400mm /1200mm sweep and refixing on same location or other location of any type/make and size carefully from fan hook, and transporting from any location to MES E/M store yard and back after repairing complete all as specified and directed.
Stripping of ceiling fan washing thoroughly of bearing/bush by petrol, washing/cleaning fan blades body etc thoroughly, greasing, replacement of worn out/defective unserviceable parts (wherever necessary) reassembling the same and testing the fan on full load to entire satisfaction of Engineer-in-Charge complete all as specified and directed. Note:- (i) Defective/unserviceable parts replaced will be paid separately in respective item of Sch 'A' as Supply only.
M&L for rewinding Ceiling fan by cutting the existing copper winding of ceiling fan of 1200/1400MM capacity and make any type with super enamelled copper wire of suitable size incl all insulating materials varnishing and neating complete incl satisfactory testing of fan on full load to entire satisfaction of Engineer-in-Charge complete all as specified and directed.
Supply only rubber reels incl shackle clamp, bolts, nuts, washers split pins of appropriate size as required complete all as specified and directed
Supply only down rod made of 15mm dia GI pipe medium grade 45 cm long incl machining/ threading/drilling hole of size suitable for nuts and bolts washer and split pin suitable for any size and make of fan complete all as specified and directed.
Supply only plastic canopy upper & lower of any size and make of ceiling fan fixed with suitable size of screws complete all as specified and directed.
Taking down carefuiiy exhaust fan of size 200mm to 300mm sweep of any description and position and transporting to MES E/M store yard and stripping of the fan, washing thoroughly bearing/bush by petrol, washing fan blade body etc thoroughly, greasing, replacement of worn out/defective unserviceable parts (wherever necessary) reassembling the same incl twisted twin core flexible wire upto 0.7 mtrs long size 24/0, 020 (ISI marked) and testing the fan on full load to the entire satisfaction of Eng-in-Charge and refixing in same location or other location complete all as specified and directed. Note :- (i) Defective/unserviceable parts replaced will be paid separately in respective item of Sch 'A' as Supply only.
M&L for rewinding the armature for 200mm to 300mm sweep exhaust fan any make with super enamelled copper wire of suitable size with and including all insulating materials varnishing complete all as specified and directed.
S&F in repairs exhaust fan louver of out side building including making necessary arrangement like ladder/scaff holding etc and drilling of hole for fitting of exhaust fan louver complete all as specified and directed.
S&F in repair switch piano, flush type single pole one way 5 Amps 230 volt complete all as specified and directed.
S&F in repair switch piano, flush type single pole two way 5 Amps 230 volt complete all as specified and directed.
S&F in repair bell push, flush type, 5 Amps complete all as specified and directed.
S&F in repairs switch flush type 15 Amp single pole one way complete all as specified and directed.
S&F in repair socket outlet 3 pin, 2-in-1, 5 Amps flush type complete all as specified and directed.
S&F in repair switch socket combination outlet 2-in-1, 5 Amp flush type complete all as specified and directed.
S&F in repair switch socket combination multipurpose, 2 in 1, 3 pin, 5 & 15 Amp flush type complete all as specified and directed.
S&F in repairs socket outlet 3 Pin 15 Amp 240 volts complete all as specified and directed.
S&F in repair ceiling rose surface bakelite 65x50mm three terminal complete all as specified and directed.
S&F in repair bell ding-dong, electric, 230 volt, single phase complete all as specified and directed.
S&F in repair lamp holder insulated PVC /Polycarbonate/ bakelite body, with back plate suitable for batten fitting or PVC round or squre box, complete all as specified and directed.
S&F in repair stepped type electronic fan regulator, two module size, flush type complete all as specified and directed.
S&F in repair fan capcitor 2.5 Mfd suitable for 1200/1400mm sweep ceiling fan complete all as directed. (Make-Universal or equivalent)
Supply & fix in repair ventilating fans AC single phase 230/ 240 V of size 250 mm sweep with louver shutter with frame and necessary fixing accessories , writing MES No. with black synthetic enamel paint 2 cm high in letter complete with necessary connection up with and including three core copper flexible cable with flexible wire cover of plastic white in colour and connection from ceiling rose to ventilating fan terminal etc complete all as specified and directed. (Make-Usha/Havells or equivalent.)
Supply only ball bearing of size suitable for exhaust fan upto 300 mm sweep complete all as specified and directed. (Make : NBC/SKF/SBBI)
Supply only condenser ISI marked 230/240/250 volts AC 4 MFD suitable for exhaust fan incl condenser spacer and soldering of condenser wire to fan wire and fixing complete all as specified and directed. (Make : Usha/ Asian/ EPCOS).
Supply and fix in repair modular fan regulator,120 W-2 module complete all as specified and directed.
S&F in repair modular switch 1 way 6 amp, 1 module complete all as specified and directed.
S&F in repair modular switch 1 way 16 amp, 1 module complete all as specified and directed.
S&F in repair modular socket, 6 Amp 2/3 pin combined 2 module complete all as specified and directed.
S&F in repair modular socket, 16 Amp 2/3 pin combined 2 module complete all as specified and directed.
S&F in repair modular Bell push 6 Amp 1 module complete all as specified and directed.
Dressing of pre-wired casing caping /PVC conduit of One light /fan/ exhaust fan point controlled by one number one way 5 Amp switch by changing Casing caping /PVC conduit and necessary connecting items (such as flexiable conduit , screws etc) complete all as specified and directed.
S&F in repair for MCCBs 415 V, 16 KA, 4P, 63 Amps complete all as specified and directed. (Make :- Legrand/ Siemens/Schnider/L&T)
S&F in repair MCBs, SP 6 to 32 Amps 240 V, 50 Hz, 10 kA ,C-series complete all as specified and directed. (Make :- Legrand/ Siemens/Schnider/L&T)
S&F in repair MCBs, SPN 32 Amps 240 V, 50 Hz, 10 kA ,C-series complete all as specified and directed. (Make :- Legrand/ Siemens/Schnider/L&T)
S&F in repair/replacement MCB TPN 40 to 63 Amps 415 V, 50 Hz,10 kA,C-series complete all as specified and directed. (Make :- Legrand/ Siemens/Schnider/L&T)
Supply fix in repair MCCB DB IP-43 of sheet metal enclosure double door VTPN 4 way with 250 Amps rated copper bus bar 415 volt and grouted in wall with PCC (1:2:4) type B-1 using 20 mm graded stone aggregate complete all as specified and directed. (Make-Legrand Cat No-5077 45 or equivalent of Siemens/Schnider/L&T)
Supply fix in repair MCB DB of sheet metal enclosure double door SPN 8 way with 200 A rated bus bar and grouted in wall with PCC (1:2:4) type B-1 using 20 mm graded stone aggregate complete all as specified and directed. (Make :- Legrand/ Siemens/Schnider/L&T)
Supply fix in repair MCB DB of sheet metal enclosure double door SPN 4 way with 200 A rated bus bar and grouted in wall with PCC (1:2:4) type B-1 using 20 mm graded stone aggregate complete all as specified and directed. (Make :- Legrand/ Siemens/Schnider/L&T)
S&F in repair/replacement for factory made, sheet steel distribution boards, TPN, 4 Way, double door,with provision for FP MCB as incomer and SP MCBs as outgoing complete and grouted in wall with PCC (1:2:4) type B-1 using 20 mm graded stone aggregate complete all as specified and directed. (Make :- Legrand/ Siemens/Schnider/L&T)
Taking down carefully by unscrewing from boards/outlet boxes,fittings and fixtures such as switches, sockets,ceiling roses,lamp holders,brackets,ceiling fitting ,bulkhead fitting,tubelight fitting and regulators etc for reuse at site or carring to the store ( To be measured only when found serviceable in all respect complete for reuse) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
Refixing serviceable fitting /fixtures as obtained from taking down item boards/outlet boxes, fittings and fixtures, here in before and connecting up with copper conductor cable of suitable size in locatation complete all as specified and directed.
Disconnecting the main power supply to distribution box and make a proper dressing of SPN/TPN/VTPN MCB/MCCB DBs of pre-connected MCBs by changing screw of DB cover ,earth wire and other necessary connecting items and dressing of wires with the help of cable tie inside the distribution box and duly connecting up complete all as specified and directed.
M&L Preparetion of old surface of ceiling /exhaust fan with blades in situ and applying one coat of synthetic enamel paint (Duco) using spray painting machine complete all as specified and directed.
BALEN DEWAN
LAXMI CONSTRUCTION
M/S SHARMA CONSTRUCTION
M/s DAS AND CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .