Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance D 662 WZ 1598 R 1 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹68,800
Closing Date
5 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF SUBROTO PARK DELHI CANTT
GE AF SUBROTO PARK DELHI CANTT
EXECUTION OF CERTAIN SANCTIONED WORKS IN THE AREA OF AGE BR II AND AGE EMI AT SUBROTO PARK UNDER GE AF SUBROTO PARK
2021_MES_459517_1
GE/SP/TOKEN-17/2021-2022
Open Tender
Civil Works
Item Rate
180 days
GE AF SUBROTO PARK DELHI CANTT
AS PER TENDER
7 documents required · 7 mandatory
₹500
GE AF SUBROTO PARK
₹68,800
Yes
24 Aug 2021
14 Jul 2021
6 Aug 2021
14 Jul 2021
5 Aug 2021
22 Jul 2021
14 Jul 2021 - 21 Jul 2021
60 days
Amount
Dismantling floor,hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises Complete all as specified and directed by Engineer-in-Charge.
Demolition of PCC, of any description and in any position not otherwise specifically provided for (incl reinforcement cut as required to facilities demolition) Complete all as specified and directed by Engineer-in-Charge.
Taking down chowkats or frames not exc 1.5 Sqm each with shutters(without taking off shutters from the frames) and remove to store Complete all as specified and as directed by Engineer-in-Charge..
All as per Item No. 3 above but exc 1.5 Sqm and n.exc 4 Sqm each complete all as specified and directed by Engineer-in-Charge.
Taking down steel tubing and connections 20mm bore complete all as specified and directed by Engineer-in-Charge.
All as per item No 5 above but 15mm bore .
Dismantling water tanks and removing to store exc 250 & n exc 500 lts capacity complete all as specified and directed by Engineer-in-Charge.
Demolition and breaking of 100mm dia drain pipes (salt glazed ware, AC or reinforcement concrete) set in cement mortar complete all as specified and directed by Engineer-in-Charge.
Dismantling cast iron work of any description complete all as specified and as directed by Engineer-in-Charge.
Demolition of brick or stone boulder masnory, built in cement mortar including all quoins, arches, pillars, etc., but excluding ashlar facing, dressed stonework and percast concrete articles complete all as specified and directed by Engineer-in-Charge.
Demolition of RCC, of any description and in any position not otherwise specifically provided for (incl reinforcement cut as required to facilities demolition) complete all as specified and directed by Engineer-in-Charge.
Taking down cement or cement lime plaster on brick walls incl racking out joints hacking for key scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15mm thick in CM 1:6 on other than fair faces of brick work or concrete surfaces of walls, finished even and smooth ( without using extra cement) complete all as specified and directed by Engineer-in-Charge.
M&L for rendering CM (1:4) 15 mm thick on fair faces of brick surfaces or concrete surfaces even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for rendering CM (1:4) 10 mm thick on concrete surfaces of ceiling, even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Supply only liquid water proofing compound complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new plastered surfaces of walls, and applying two coats of distemper oil emulsion over a coat of primer incl 3mm thick elastomeric wall care putty on walls complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new plastered surfaces of walls, and applying three coats of white wash on walls over a coat of primer complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new plastered surfaces of walls, and applying two coats of cement based paint over a coat of primer complete all as specified and as directed by Engineer-in-Charge.
M&L preparation of new plastered or unplastered surface and applying three coats of white wash on ceiling complete all as specified and directed by Engineer-in-Charge.
M & L for complete removal of existing treatment of surfaces by steel wire brushing, scraping down smoke soots, moulds, moss and efflorescent salts etc on wall and applying two coats of oil emulsion distemper over a coat of primer including 3mm thick wall care putty on wall complete all specified and as directed by Engineer-in-Charge.
M&L for providing water proofing treatment to RCC sunken slab as specified and directed as under (a) cleaning the exisiting RCC sunken slab and vertical wall/RCC beam and hacking the surface (b) 15 mm thick plastering over the floor & vertical surface in CM 1:4, mixed with liquid water proofing compound @ 200 per 50 kg of cement trowelled to even and smooth finish without using extra cement (c) Filling the sunken portion with water for 72 hrs and carrying out the ponding test. (Any leakage/seepage noticed shall be repaired) (d) Applying two coats of elastometric acrylic water proof coating make : Dr Fixit of pidilite, Tapecrete from Cico or equivalent in sika as per sqm in each coat with roller application (Note: each coat of elastomeric acrylic compound requires 6-8 hrs to dry up itself second coat shall be applied on getting the first coat completely dried up. Min quantity required for coating as per manufacture instruction) complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:4:8 type D2 (using 40mm graded stone aggregates) as in mass concrete in floors and sunken portion Complete all as specified and directed by Engineer-in-Charge.
M&L for 40 mm thick PCC 1:2:4 type B1 (using 20 mm graded stone aggregates) as in sub base for flooring complete all as specified and directed by Engineer-in-Charge.
S&F non skid coloured ceramic tiles area of each tiles exceeding 0.11sqm but not exceeding 0.18 Sqm and 7mm thick as in floor set & jointed in neat cement slurry & pointed in coloured cement to match over 15mm thick screed in cement mortar 1:4 Complete all as specified and as directed by Engineer-in-Charge.
Material and labour for glazed ceramic coloured tiles in vertical surface 300x450X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick screed in cement 1 :4 and pointed in white or coloured cement to match the shade complete all as specified and directed by Engineer-in-Charge.
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm double side prelam PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification & drawing complete all as specified and directed by Engineer-in-Charge.
S&F factory Made solid PVC Moulded Door Shutter with Particle Board Core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm prelam PVC Sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed by Engineer-in-Charge.
S&F 150 mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed by Engineer-in-Charge.
S&F 150 mm long extruded alloy handels fabricated type anodisedcomplete all as specified and directed by Engineer-in-Charge.
S&F 100 mm long butt hinges extruded alluminium alloy with galvanised mild steel hing pin anodised and fixed type B 21 complete all as specified and directed by Engineer-in-Charge.
S&F 20mm bore Tubes, 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-Charge.
All as per item No 32 above but 15mm bore .
All as per item No 32 above but refixing 20 mm dia old GI tubing and connections in new or old posn (wall, ceilling, Floors etc) complete all specified and as directed by Engineer-in-Charge.
S & F in rotational moulded polyethylene water tank 500 litre capacity tripple layer (white colour) (cylindrical vertical with closed top) hoisted and fixed as specified in SSR Part-I and directed by Engineer-in-Charge.
S&F 20 mm bore Gun Metal globe or gate valves with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and as directed by Engineer-in-Charge.
S&F 20 mm Ball brass valves high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule and fixed complete all as specified and directed by Engineer-in-Charge.
M&L for Brick work with subclass B bricks, staright or curved on plan exc 6.00 mtr mean redius, biult in 1:6 cement mortar complete all as specified and as directed by Engineer-in-Charge.
M&L for brick work with subclass B bricks, staright or curved on plan on plan to any redius in half brick thickness wall, biult in 1:4 cement mortar complete all as specified and directed by Engineer-in-Charge.
M&L for type B1, 1:2:4 (20 mm graded aggregate) as in shelves supported on wall etc, including necessary formwork all specified and directed by Engr-In-Charge.
M&L for Precast cement concrete type B1, 1:2:4 (20 mm graded aggregate) as in ladning cover slabs for man holes/ drain covers set in CM 1:4 complete as specified and directed by Engr-In-Charge.
S&F mild steel bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
All as per item No 42 above but 6 to 8 mm dia TMT Bars
S&F 100 mm dia cast iron soil waste and went pipe in any length with or without ears with cement joints laid in trenches or in floors complete all as specified and directed by Engineer-in-Charge.
All as per item No 44 above but fixed to walls
All as per item No 44 above but 75 mm dia
All as per item No 44 above but fixed to walls of 75 mm dia
M&L for coloured granite slab, 20 + mm thick, as in Plateforms of Kitchen and similar work etc., bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including Chamfering\Rounding the edges. Note :- (colour & design approved by GE). Over 15mm thick screed bed in CM 1:4 complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs Vitreous China wash basin white ovel shape counter top of size 630x450mm complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Single lever wash basin mixer with popup waste system and 450 mm long braidaed hoses chromium plated . Make- Cat Part No. ORM-10051 B of Jaquar or its Equivalent as per sample approved make complete all as specified and directed by Engineer-in-Charge.
S & F in in repairs CP waste coupling 32mm size half threaded with 130mm height completed as of Make-Cat Part No ALD-709 of Jaquar or its equivalent as approved make complete all as specified and directed by Engineer-in-Charge.
S&F in repairs 15 mm bore angle valve chromium plated with wall flange and fancy type with high pressure screwed down with CP flange.Make- ORM- 10053 of Jaquar or its equivalent Parko/Marc complete all as specified and directed by Engineer-in-Charge.
S&F in repairs 32 mm brass cromium plated bottel traps for wash basin with inlet and outlet screwed for pipe or connections incl necessay packing union and cap and fixed complete all as specified and directed by Engr-in-Charge.
S&F in repairs PVC bathroom mirror cabinet of size 450x600mm Make Prayag or its equivalent complete all as specified and directed by Engineer-in-Charge.
S&F in repairs wall mounted Vitreous China wash down water closet pan, white (including fixing bolts, Push cock flushing cistern and flush pipe) including connection to drain (or outgoing pipe) and to flushing pipe, anti syphonage pipe, Plastic water closet seat, black / white , closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device etc. complete all as specified and directed by Engineer-in-Charge.
S & F in repairs hand shower (health faucet ) with 1.0 m long easy flex tube in chrome finish and wall hock Make-Cat Part No. ALD-CHR-565 of Jaquar or its equivalent approved make complete all as specified and directed by Engineer-in-Charge.
S & F in repairs CP paper holder of Make-AHS-1553 of Jaquar or its equivalent approved make complete all as specified and directed by Engineer-in-Charge.
S&F in repairs jet spray with necessary fixing arrangement complete all as specified and as directed by Engineer-in-Charge. Make:Jaquar or MARC/EM/PARKO or equivalent
S&F in repairs CP towel ring of approved make complete all as specified and directed by Engineer-in-Charge. Make AQN -7721 of jaquar or MARC/EM or equivalent
S & F in repairs bib tap cast copper alloy fancy type chromium plated with crutch or butterfly handle screwed down for 15mm bore pipe complete all as specified and directed by Engineer-in-Charge. Make: CON -037KKN of Jaquar or MARK/GEM/PARKO or equivalent
S & F in repairs CP Soap dish of Make-AQN-7731 of Jaquar MARC/GEM/PARKO Or Equivalent complete all as specified and directed by Engineer-in-Charge.
S & F repair corner glass shelf with bracket of Make : ACN-1173 of Jaquar orMARC/GEM/PARKO Or Equivalent complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs 15mm bore Chromium Plated shower rose complete all as specified and directed by Engineer-in-Charge.
S & F in repairs 15mm dia Brass CP wall mixer with provision for over head shower with 115 mm long bend pipe on upper side, conecting legs & wall flanges for mixing hot & cold water screwed down for iron pipe complete all as specified and directed by Engr in Charge. Make : Cat Part No. FUS 29273 UPR of Jaquar/MARC/GEM/PARKO Or Equivalent
S&F in repairs brass powder coated cloth hanging hooks set of six hooks complete all as specified and directed by Engr-in-charge.
S&F in repairs 15mm bore two way angle valve chromium plated with wall flange and fancy type high pressure screwed down with CP flange complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60 cm long complete all as specified and directed by Engineer in Charge. Make : Jaquar/MARC/GEM/PARKO Or Equivalent
S & F repair CP towel racks with lower hanger complete all as specified and directed by Engr-in-Charge. Make : AKP-35781PS of Jaquar/MARC/GEM/PARKO Or Equivalent
S&F in repairs PTMT grating round of 100mm dia (Miniumum wt 50gms) complete all as specified and directed by Engineer-in-Charge.
S&F in repiar CP connection 15mm size for Hot & Cold water with CP nuts of length 450mm long all complete all as specified and as directed by Engineer-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for manholes etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and as directed by Engineer-in-Charge.
All as per item No 72 above but in Hard rock.
M&L for treating the bottom and sides of excavation at the rate 5 ltrs of emulssion per sqm of surface area complete all as specified and directed by Engineer-in-Charge.
M&L for treating the top surface of filled earth at the rate 5 ltrs of emulssion per sqm of surface area complete all as specified and directed by Engineer-in-Charge.
M&L for treating the soil under plinth protection at the rate 5 ltrs of emulssion per sqm of surface area complete all as specified and as directed by Engineer-in-Charge.
M&L for RCC design mix M 30 ( using 20 mm graded stone aggregate) as in foundation, raft footing, foundation beams, plinth beam, base for columns etc, basement slab under reamed piles and mass concrete complete all as specified and directed by Engineer-in-Charge.
M&L for RCC design mix M 30 ( using 20 mm graded stone aggregate) as in slabs supported on walls,, beams and columns in floors, roofs, landing balconey, canopies, deck slab and in shelves complete all as specified and directed by Engineer in charge.
All as per item No 78 above but as in chajjas
M&L for RCC design mix M 30 ( using 20 mm graded stone aggregate) as beams, cantilivers, lintel over 1.5 m span complete all as specified and directed by Engineer-in-Charge.
M&L for RCC design mix M 30 ( using 20 mm graded stone aggregate) as coloumns, pillars post and sturts complete all as speciied and directed by Engineer in charge.
M&L for form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits if any of foundation and plinth beams and simillar work vertical or laterels complete all as specified and directed by Engineer-in-Charge.
M&L form work to sofits of suspended slabs such as roof slabs, floor slabs, landings and similar work n.exc. 200 mm thick ( hroizontal or sloping ) complete all as specified and directed by Engineer in charge.
M&L form work to edges of concrete flats, break in floors, opening in concrte walls, floors and roofs and sides of PCC / RCC bends in walls horizontal or sloping and similar work all exceeding 20 cm wide complete all as specified and directed by Engineer in charge
M&L form work to sides sofits of floor of roof beams complete all as specified and directed by Engineer in charge
M&L for form work to chajas incl edges complete all as specified and directed by Engineer in charge.
M&L for form work to sides of pillars, posts complete all as specified and directed by Engineer in charge.
M&L for providing and fixing factory made uPVC white colour sliding window. three track made of extruded profiles with wall thickness of 2.3mm (+/0.2mm). Window profile with hollow section with multi chamber, frame (88mmx52mm), sliding sash (42mmx67mm), sliding mesh sash (42mm x 57 mm) sliding interlock (One vertical length in each shutters) (45.5mmx28mm) Glazing bead(24.5mm x 16mm ) will be mitered cut and fusion welded at all corners, including railing of holes for fixing hardware and drianage of water etc. making arrangement for fixing of hardware EPDM gasket 1.2 + 0.2 mm thick galvanised steel frame (30mmx18 mm) 2 Nos , sliding sash (30mmx18 mm), sliding mesh sash (26mm x 10 mm ) profile to be inserted in required profile, frame will be fixed to the wall with 8 mm x 100 mm long fasteners. Hardware [Touch lock of zinc alloyed (white powder coated) steel roller system stainless steel wire cloth 0.36 mm nominal dia of wire and average width of apreature 1.40mm and required accessories] Note the unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose) area exceeding 2.00 sqm each complete all as specified and directed by Engr-in-Charge.
M&L for 150 mm thick PCC 1:4:8 type D2 (using 40mm graded stone aggregates) as in sub base in floors complete all as specified and directed by Engineer in charge.
M&L for returning filling in incl spreading watering and well ramming in layer n.exc. 25 cm complete all as specified and directed by Engineer in charge.
M&L for removing excavated materials n.exc. 50m and depositing where directed at a level n.exc. 1.5m above the starting point complete all as specified and directed by Engineer in charge.
M&L for PCC type B1 (1:2:4) using 20 mm graded aggregate as in coping, benching etc including necessary form work, chamfers, weatherings, throating etc complete all as specified and as directed by Engineer-in-Charge.
M&L for two coats of synthetic enamel paints on newly steel surface over a coat of red oxide primer incl preparation of surface complete all as specified and directed by Engr -in-Charge.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and as directed by Engineer-in-Charge.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and as directed by Engineer-in-Charge.
S&F Steel work in tubular, trusses, purlins, rafters, struts, vertical member and similar work including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed by Engr-in-Charge.
M&L for Cement concrete type C2, 1:3:6 (using 40mm graded aggregate) in foundations, filling and mass concretecomplete all as specified and directed by Engr-in-Charge.
M&L for preparation of newly platered or unplastered surface and applying three coats of white wash on surface of wall complete all as specified and directed by Engineer-in-Charge.
M&L for false ceilings using GI snap grid system with rool-ormed out of hot drip galvanised steel capings (powder coated) majn gunner 38x 24 mm, cross Tee 29x24mm nnd wall angle 24x 24mm members suspended with 4mm dia GI wire, carry maximum load upto 8.1kg/sqm with 4mm thick designer ceiling board, prepainted cement fiber board size 595x595x4mm thick any texture (Lake, Hill, Ocean cascade or Electra) suspended from RCC roof/structural members of sofsits angle cleat cut out etc to other required line and shape as per manufactureres recommendation at any height compete all as specified and directed by GE, Make Everest ceiling and grid system Regular T-2430 or its equivalent in of "Ramco/Charminar/Armstrong"
M&L for aluminium powder coated of coloured frame and other accessories suitable section as in fixed partition, door and as required , glazing aluminium clips, Aluminium bracing and other fixing aluminium section complete all as specified and directed by Engineer-in-Charge
S &F prelaminated particle board 9mm thick, exterior grade, prelaminated both side with decorative choice lamination fixed with aluminium galzing clips as in door shutter/partation etc complete all as specified and directed by Engineer-in-Charge
Modular work station of 45mm thick prelaminated top of 25mm thick as per colour approved workstation having glass/facbric/white board partition above the top of the table, with mobile padestal, Keyboard and CPU trolly. Over all ze for per seat 1050x600x1200mm. (Single seat) Make: Royal Koas,Model No ESCWS/009 or its equvalent.
M&L for point wiring with single core PVC insulated unsheathed 1100 volt grade cable with multi stranded copper conductor of size 1.5 Sq mm FRLS (Normal area) drawn through and including non metallic rigid PVC concealed conduit, medium grade, ISI marked not less than 20mm dia, concealed in wall, ceilling with GI saddles GI screws rawl plugs (concealed conduit wiring) with all fittings including Tee, Junction boxes and provision of pressed steel terminal modular box with powder coated of suitable size for mounting switch/ sockets and regulators and drawing continous earth wire of PVC insulated unsheathed 1100 Volts grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area) complete all as specified and directed by Engineer-in-Charge. Note (a) Cost for cutting, chasing and making good to existing surfaces and cost of Modular metal flush box are deemed to be included in the Quoted rate. (a) For one light point controlled by one SP switch.
S&F Modular switch 1 way 6A, 1 modules suitable for 240 Volt AC complete all as specified and directed by Engineer-in-Charge. Make : Crabtree/ Legrand/ Anchor Roma
S&F white cover plate with frame, 4 module complete all as specified and directed by Engineer-in-Charge. Make- Crabtree/ Legrand/ Anchor Roma.
S&F of LED luminaire 600mmx600mm 35/36 watt, 220 V AC recessed type with high eficiency PMMA diffuser sof glare free light complete with driver, holder & IED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-in-Charge. Make- Halonix/ Polycab/Havells
Supply and installation wall split units indoor/ outdoor capacity of 1.5 Ton complete with cordless remote control unit and with in built air ionisr and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 of capacity 1.5 Ton fitted on wall and out door to be fixed on roof/wall at requirement place including all necessary electrical connections, bolting, nuts, clamping of 3 core copper cable, cooling tube, drain water pipe etc all as specified and directed by Engineer-in-Charge. Make : Voltas/LG/Blue Star.
Supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with output voltage stablizer at 230 V with accuracy of + 2.5% and of capacity 5.0 KVA including fixing on wall and necessary electrical connections all as specified and directed by Engineer-in-Charge. Make- Blue qurd/voline.
S&F cross arms bracings supports clamps and back plates fabricated from structural steel sections including nuts bolts washers welding bending cold or hold drilled holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat one under and one finished coat of paint for installation of condesning unit on the wall ground complete all as specified and directed by Engineer-in-Charge.
S&F low denisity polyehylene pipes (LDPE) of pressure rating 6 kg cm 2 drain pipes of size 40 mm from indoor unit to exist point as per design including accessories climps fastners complete as as specified and directed by Engineer-in-Charge.
M&Lfor laying of copper tubing of dia 1/2" including insulation and brazing work complete all as specified and as directed by Engineer-in-Charge.
M&L laying of copper tubing of dia 1/4" including insulation and brazing work complete all as specified and directed by Engineer-in-Charge.
S&F of 3 core flexible copper cable of size 2.5 Sqm 1100V grade complete fixing on wall by clamping/securing including connections complete all as specified and as directed by Engineer-in-Charge.
Supply and lay (in trenches/duct/fixing to pole/wall or in such similar position) LT UG cable XLPE insulated armoured and PVC sheathed LT 1100 Volts grade with aluminium conductor of stranded of size 95 Sqmm 3.5 core complete all as specified and directed by Engr-in-Charge. Make ; Havells/ Polycab/ Gloster/ Bharat electrical cables
Supply and lay (in trenches/duct/fixing to pole/wall or in such similar position) LT UG cable XLPE insulated armoured and PVC sheathed LT 1100 Volts grade with aluminium conductor of stranded of size 50 Sqmm 3.5 core. Make ; Havells/ Polycab/ Gloster/ Bha
Supply and lay (in trenches/duct/fixing to pole/wall or in such similar position) LT UG cable XLPE insulated armoured and PVC sheathed LT 1100 Volts grade with aluminium conductor of stranded of size 35 Sqmm 3.5 core complete all as specified and directed by Engineer-in-Charge. Make ; Havells/ Polycab/ Gloster/ Bha
Supply and lay (in trenches/duct/fixing to pole/wall or in such similar position) LT UG cable XLPE insulated armoured and PVC sheathed LT 1100 Volts grade with aluminium conductor of stranded of size 25 Sqmm 3.5 core complete all as specified and directed by Engineer-in-Charge. Make ; Havells/ Polycab/ Gloster/ Bha
M&L for disconnecting of LT cable from existing position and removing of al interconnection electrical cable and cutting of burned cable again replacing of lugs as per site requirement and taking out LT panel and earthing strip then shifting to given location including grouting and necessary PCC foundation for installation LT Panel there after connection of LT Cable with proper lugs and nuts bolts complete all as specified and directed by Engineer-in-Charge
Supply and jointing Straight through joint epoxy type for LT cable PVC/XLPE insulated armoured aluminium conductor of sizes from 25 sqmm 3.5 core to 50 Sq mm x 3.5 core 1100 volts grade complete with jointing kit complete all as specified and directed by Engineer-in-Charge. Make : 3M / Denson/ yamuna
Supply and jointing Straight through joint epoxy type for LT cable PVC/XLPE insulated armoured aluminium conductor of sizes from 75 sqmm 3.5 core to 120 Sq mm x 3.5 core 1100 volts grade complete with jointing kit. Make : 3M / Denson/ yamuna
TUSHAR ASSOCIATES
Mahesh Enterprises
Vishal Enterprises
shiva enterprises
Skyline Encon
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .