Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.6 LRejected-Finance LUDHIANA | LUDHIANA | PUNJAB | 141001 | ₹7.6 L | L1 | Rejected-Finance Quoted rate found higher by precurement comittee.
So, this tenderis rejected. |
| 2 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Others-not registered in this division/circle |
Tender Value
₹7 L
EMD Value
₹14,000
Closing Date
4 Mar 2026, 6:00 pmClosed
Executive Engineer Regulation Dn IV IGNP N
Executive Engineer Regulation Dn IV IGNP Colony Nachna (Jaisalmer)
Repairing of LT panels and accessories electric motors changing cable and other electric item at Head cum cross regulator RD 1254 of IGMN
2026_WRDAS_540734_1
NIT 02 of Year 2025-26
Open Tender
Civil Works - Canal
90 days
NACHANA
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Secretary RREIS
₹14,000
Yes
12 Mar 2026
24 Feb 2026
5 Mar 2026
24 Feb 2026
4 Mar 2026
24 Feb 2026
S&F following sizes of ISI marked ( IS:14927 P - II ) virgin material UPVC trunking along with accessories like coupler, inner, outer, elbow, square box, tee, end cap etc. on surface with screws, expansion fasteners as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 38x25mm
Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 1x15 sq.mm
Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 1x4 sq.mm
Providing & Fixing of 240/415 V isolator ISI marked IS:13947-III/conforming to IEC 60947-3, suitable for AC22A utilization category, 4KV impulse withstand voltage, true contact indication, Red colour dolly / lever shall have single mould covering over all poles for operation , two position din rail mounting, minimum phase termination capacity of 35sq.mm. IP 20 contact protection and fitted in existing distribution board / sheet including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 80A/100 Rating double pole
Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 12 WAY
Providing and fixing of power plug point with non modular accessories as per PWD specification for electrical Works with Galvanized box of 1.2 mm thick with earth terminal with suitable size phenolic laminated sheet (IS : 2036 - 1995) cover including cost of 16 amp. Switch (IS :3854) and 3/6 pin 16 amp. socket outlet making connection , testing , etc. as required. . For specification of Wiring accessories refer Chapter E - 07 related item & For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
Providing & Fixing of 16 amp. Combined flush type non modular socket and switch set with indicator and fuse set as per PWD specification for electrical Works, made out from industrial grade Polycarbonate or fire resistant ABS material including cutting hole in tile and making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR.
Providing & Fixing of 6 amp. Combined flush type non modular socket and switch set with indicator and fuse set as per PWD specification for electrical Works, made out from industrial grade Polycarbonate or fire resistant ABS material including cutting hole in tile and making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
Providing & Fixing of ISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
Providing & Fixing of ISI marked (IS:1258) batten/angle amp holder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screwsincluding making connection testing etc. as required. All as per pre approved by ngineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
Labour charges for dismantling of surface/ recessed switch board of any size and depositing the same with listing of material in store.
Labour charges for dismantling of switch accessories like switch, socket, ceiling rose, holder and depositing the same with listing of material in store.
Labour charges for dismantling of surface PVC/ Steel conduit including wiring in conduit, conduit fittings and depositing the same with listing of material in store
Providing & Fixing of Wiring Accessories OEM fabricated following size virgin material UPVC modular boxes on surface suitable for modular accessories as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . (10-12 module)
Providing & Fixing of Wiring Accessories OEM fabricated following size virgin material UPVC modular boxes on surface suitable formodular accessories as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR . (6-8 module)
Providing & Fixing of Wiring Accessories OEM fabricated following size virgin material UPVC modular boxes on surface suitable formodular accessories as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR . (1-2-3module)
Providing & Fixing of modular type switch/ bell push duly ISI marked (IS:3854)with CM/L no. printed and made out of unbreakable and fire retardant vergin UV tabilized Polycarbonate with brass terminals andcaptive screws & silver alloycontact tip with IP-20rating ,minimum widthof switch toggle( PUSH PART ) should not less then 20mm, including all asper pre approved by Engineer ncharge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printed made out ofunbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR(5 step fan regulator 2 module 360 degree rotating)
Providing & Fixing of modular type lockable feature socket duly made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , including all as per pre approved by Engineer in charge,making onnections, testing etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR9(6 A 3/5 pin shuttered socket)
Providing & Fixing of modular type lockable feature socket duly made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , including all as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR9(6 /16A shuttered socket)
Providing & Fixing of BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan Conforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .(1200 mm sweep BEE 3 star rated (service value>=5.0 to < 5.5)
Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .(1170mm (+/-10%) LED battper wire [c) Interconnection betwe
Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .(LED street light fixture with minimum lumen output 3700 lm)
Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each . Integrated potted driver as a unique BIS R number having efficiency more than 85 % and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K ±355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .(High power LED Flood light minimum lumen output 3700 lm)
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured Copper cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with electrolytic grade Copper made of copper rods confirming to IS 613-1964, of purity >99.7 %, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR( 2.5 Sq mm with 2 core)
Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. double pole MCB (With B/C curve tripping characteristics)MCB for electric pole (6A to 32 A Rating
Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. double pole MCB (With B/C curve tripping characteristics) 50/63 A rating
Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 5sq.mm. ,conductor line load reversibility , IP 20 contact rotection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. Four pole MCB (With B/C curve tripping characteristics) (6A to 32 A rating)
Providing & Fixing of din rail mounting contactor and accessories confirming to IEC 61095 with following description and configuration in existing distribution board / sheet including making connections, testing etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR.Modular contactor63A-2NO+2NC
P & F of Front / Side mounting Add on Auxiliary Contact Block with required NO& NC combination including making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR
Providing&Fixingofthermaloverloadrelaywithbuiltinsinglephaseprotectionandhavingatleast1NO&1NCcontacts,manual/autoresetfacilityincludingmakingconnectiontestingetc.asrequired.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnical parameters of products/ work , refer Annexure "A" attached with this BSR .UP to 14 AMP
Providing & Fixing of BIS approved Current Transformer as per PWD specification for electrical Works ,ISI marked as per IS 2705-1992/ conforming to IEC 60044-1, with secondary terminal of CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as required Current transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .Ring type tape wound CT, CT Class1,Ratio upto 150/5,burden 5VA
SupplyingandfixingofAluminium(IEC60105ISO209-1,2)/Copper(IEC60028)busbarbymeansofSMC/DMCtypeinsulatorwithstandardshortcircuitwithstandcapacity,hightensilenutsandboltsspringwashersinexistingpanelincludingbending,cuttinginrequiredshapeandsizeandcolourcodingwithheatshrinkablePVCsleeves.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/work,referAnnexure"A"attachedwiththisBSR.Electrolyticgradealuminiumbusbar6010 grade
Providing & Fixing of flush head push button actuators IEC 60947 with integral circuit, IP 65 above panel & IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, including connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .Non luminous type
Providing&FixingofElectricalinsulatingrubbermattsasperPWDspecificationforelectricalWorks,ISImarkedconfirmingtoIS:15652/2006withonesideantiskidabberationmarksandpastingthematwithsyntheticrubberadhesiveasrequired.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/work,referAnnexure"A"attachedwiththisBSR.11kv,classb2.5mmthickwithproofvoltage22 kv AC (rms) & break down voltage 45 kv AC (rms)
Providing & Fixing of 110/220 V, unibody LED Indicating lamp IEC 60947 withintegral circuit, IP 65 above panel & IP 20 terminal block, Approx. body dia forpanel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm,contact material phospher bronze for Led, PCB contacts shall be of brass (tinplated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be100 M ohm at 500VDC including connection etc. as required. All as per preapproved by Engineer in charge. For additional technical parameters of products/work , refer Annexure "A" attached with this BSR .Red/yellow/Green colour
Providing&FixingofISOcertifiedcompanymadeoffloadchangeoverswitchfourpole/twopole,230/415V,sidehandleoperatedconformingtoIS:13947P-IIIinsheetsteelenclosurecompletewithconnectionswithlugs,testingetc.asrequiredinthefollowingrating:AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/work,referAnnexure"A"attached with this BSR .200 A four pole
Providing & Fixing of 240/415 V Residual current circuit breaker (RCCB) conforming to (IS:12640-1)/ IEC 61008 -1 , rated 4 KVimpulse withstand voltage truly current operated and shall operate on CBCT mechanisum, provision for pad lock, min. operation 10,000 upto 63 A rating and 5000 for 100 A rating and minimum phase termination capacity of 35 sq.mm. rigid wire , IP 20 contact protection with existing distribution board / sheet including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with thisBSR 63 A rating four pole 30mA sensitivity
PlateEarthingasperIS:3043withcopperEarthplateofpurity>95%ofsize600mmx600mmx3.0mmbyembodying3mtr.belowthegroundlevelwith20mmdia.G.I.'B'classwateringPipe,includingallaccessorieslikenut,bolts,reducer,nipple,wiremeshedfunnel,andHeavydutyweatherproofpoly-propyleneearthpitchamberwithlockableJamfreelidsuitableforsafeworkingload5000KgormoreofsizeTopDia.225to260mm,BottomDia300to350mm.andHeight250to300mm.andembodyingthepipecompletewithalternatelayerssaltandcoke/charcoal,testingofearthresistanceforvalueof5ohmsorlessasrequired&mustrecordbyengineerinchargeduringsitevisitandensuretoenterinmeasurmentbook.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnical parameters of products/ work , refer Annexure "A" attached with this BSR .
Providing&LayingP.V.C./XLPEinsulated&P.V.C.sheathedArmouredCoppercableconfirmingtoIS:1554P-I/IS:7098P-Iof1.1KVwithelectrolyticgradeCoppermadeofcopperrodsconfirmingtoIS613-1964,ofpurity>99.7%,round/flatstriparmouring,Inner/outersheathconfirmingtoIS:5831inexistingRCC/Hume/Stoneware/PVCpipe/openduct/cabletrench/Cabletray(withcabletie)includingtestingetc.asrequiredoffollowingsize.OEMmusthaveit'sowninhouseNABLaccrediatedLaboratoryfortestingprocedureasperIS:10810Foradditionaltechnicalparametersofproduct/workreferAnnexure'A'attachedwiththisBSR.35sq.mm,4 core
Providing&LayingP.V.C./XLPEinsulated&P.V.C.sheathedArmouredCoppercableconfirmingtoIS:1554P-I/IS:7098P-Iof1.1KVwithelectrolyticgradeCoppermadeofcopperrodsconfirmingtoIS613-1964,ofpurity>99.7%,round/flatstriparmouring,Inner/outersheathconfirmingtoIS:5831inexistingRCC/Hume/Stoneware/PVCpipe/openduct/cabletrench/Cabletray(withcabletie)includingtestingetc.asrequiredoffollowingsize.OEMmusthaveit'sowninhouseNABLaccrediatedLaboratoryfortestingprocedureasperIS:10810Foradditionaltechnicalparametersofproduct/workreferAnnexure'A'attachedwiththisBSR6sqmm4core
Providing&LayingP.V.C./XLPEinsulated&P.V.C.sheathedArmouredCoppercableconfirmingtoIS:1554P-I/IS:7098P-Iof1.1KVwithelectrolyticgradeCoppermadeofcopperrodsconfirmingtoIS613-1964,ofpurity>99.7%,round/flatstriparmouring,Inner/outersheathconfirmingtoIS:5831inexistingRCC/Hume/Stoneware/PVCpipe/openduct/cabletrench/Cabletray(withcabletie)includingtestingetc.asrequiredoffollowingsize.OEMmusthaveit'sowninhouseNABLaccrediatedLaboratoryfortestingprocedureasperIS:10810Foradditionaltechnicalparametersofproduct/workreferAnnexure'A'attachedwiththisBSR6sqmm2core
Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 1x2.5 sq.mm
Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 1x10.00 sq.mm
SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ freestanding floor mounted dust and vermin proof compartmentalised cubical panelas specifications and Other parameters required as per point (a) ,(b), (c),(d), (e),(f), (g), (h) as below:-(a)Thickness of CRCA sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachableextension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provide (b)complete panel shall undergo a process of degreasing, Water rinsing,Activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel. The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire [c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only. All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar / Flexible wire forInterconnection between Main busbar and Switchgear is to be Paid Extra ) (d)Wiring between components within switchgear and Incoming / outgoing cable shall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram.(e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.(f)Floor mounted panel shall be mounted on Base frame of ISMC channel size 100x 50 x 5 mm ( to be paid Extra )(g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Powerfrequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. bothbefore and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out.(h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)Allas per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
CO2 type fire extinguishers capacity 4.5 kg ISI mark
Providing and Applying ACRYLIC emulsion polymer waterproofing chemical coating, on over roof on over roof slabs/terrace/balconies/parapet wall etc.with following method/specification: Paint the surface with regular paint brush so as to obtain approximately 0.3mm thickness coating. apply the 2nd coat next day at right angles to the 1st coat so that total thickness of the coating should be approximately 0.6mm coverage by using above formulation will be 40 ft2/ litre of chemical. painted surface does not require any external water curing since chemical will hold sufficient water for curing.After the primer coat Apply 2 coats of modified acrylic emulsion polymer water proofing compound having solar heat reductionproperties coating @ 0.330 KG/SQM on the surface of the interval of 3-4 hours. Undulation on the surface is repairbefore the waterproofing work.
Fiber Mess Net Pasting on Roof
Structurals such as tees,angles channels and R.S. joists
Plaster in cement sand mortar 1:5 including racking of joints, smooth finishing & curing etc. complete including all lead of all construction material of thickness 12 mm( for
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 5.21 MB
Sr1RD1254.pdf
Tender Documents • 0.64 MB
BOQ_963946.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid