Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹73.7 LAccepted-AOC 1001 SHIVALIK ABAISE 100 FEET ROAD OPP ANANDNAGAR APARTMENT PRAHALADNAGAR AHMEDABAD AHMEDABAD GUJARAT 380015 | AHMADABAD | GUJARAT | 380015 | 1 | Accepted-AOC L1 | |
| 2 | 2₹77.5 L+₹3.8 L (5.12%)Rejected-Finance P 27 1 RASHTRAGURU AVENUE DUM DUM KOLKATA 700028 | 24 PARAGANAS NORTH | WEST BENGAL | 700028 | 2 | Rejected-Finance L2 | |
| 3 | Rejected-Technical | - | Rejected-Technical Not Meeting NIT eligibilty Criteria due to non submission of relevent work experiance as per NIT. | |
| 4 | Rejected-Technical 601 603 EROS APARTMENT 56 NEHRU PLACE NEW DELHI 110019 | NEW DELHI | NEW DELHI | DELHI | 110019 | - | Rejected-Technical Not Meeting NIT Criteria due to non submission of shortfall documents in CPP portal. | |
| 5 | Rejected-Technical H NO 548 387 DEVPUR RAJAJIPURAM LUCKNOW RING RAOD LUCKNOW UTTAR PRADESH 226017 | LUCKNOW | UTTAR PRADESH | 226017 | - | Rejected-Technical Not Meeting NIT Criteria due to non submission of shortfall documents in CPP portal. |
Tender Value
₹80.7 L
Closing Date
22 Feb 2021, 9:30 amClosed
Nirmal Kumar Gayen
Asst. Gen. Manager (Engg-Elect), O/O the Airport Director, VSS Airport, AAI, Jharsuguda, Odisha-768204.
Operation and Maintenance of Fire Detection, Alarm and Fighting System for two years (2021-2023) at VSS Airport, Jharsuguda.
2021_AAI_69103_1
AAI/JH/AGMEE/eNIT6/AMC/2020-21
Open Tender
Electrical Works
Works
730 days
VSS Airport
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,180
Yes
Exempted
7 Jul 2021
9 Feb 2021
24 Feb 2021
10 Feb 2021
22 Feb 2021
10 Feb 2021
10 Feb 2021 - 15 Feb 2021
Amount
SH : I : Operation and Maintenance
Job contract for round the clock ( 24X7) operation & daily maintenance of Fire Hydrant system, Novec- 1230 Gas Suppression System, Sprinkler System, Down Comers and analogue addressable fire detection & alarm system with all accessories / units /wiring viz like Pumps, Engines, Control Panel, valves , pipe lines, Alarm Panels, repeater panel,auto dialers,detectors, MCPs, hooters etc. for Terminal Building, ATC Tower Cum Technical Block,DVOR,NDB,MSSR, Glide path,Localiser and Fire Station (as detailed in the inventory) on all days including sunday / holidays etc complete as required as per the special condition of the contract excluding spare parts.
Monthly Service Contract through specilization engineer / agency for preventive/periodical/unlimited break down maintenance of Fire Hydrant system, Novec- 1230 Gas Suppression System, Sprinkler System, Down Comers and analogue addressable fire detection & alarm system with all accessories / units /wiring viz like Pumps, Engines, Control Panel, valves , pipe lines, Alarm Panels, repeater panel,auto dialers,detectors, MCPs,hooters etc. for Terminal Building, ATC Tower Cum Technical block,DVOR,NDB,MSSR and Fire Station (as detailed in the inventory) etc complete as required as per the special condition of the contract excluding spare parts.
Carrying out of Monthly Maintenance of Diesel Engine ( 72 BHP Engine make : KOEL, Model: 4R1040T) through the OEM/authorized Service Dealer etc. complete as required including replacement of B -check maintenanace by providing all spares like oil filters, fuel filters, Lub oil and coolant at every six months etc as required
Monthly maintenance of 1 No x 125 KVA Greaves Cotton Ltd make DG set ( Model no.TD4L4 ) for preventive ( monthly) and break down ( unlimited) maintence through OEM/ authorized service dealer including reapiring / replacing and adjustment of elements assemblies and sub-assemblies etc. but excluding major overhauling, top overhauling and rewinding and spare parts etc. complete as required. ( Spares parts excluded)
Supply of following B/C-check spraes for item no - 4 as and when required
L.O.FLTR+ELEMENT V8/V6
FILT. ELEMENT WITH O RING
FILTR. INSRT WITH O RING
GASKET-CYL.HEAD COVER
OUTER ELEMENT TD4L4
INNER ELEMENT TD4L4
GREAVES LUB OIL 20Ltr. CI-4
COOLANT ADDITIVE 5LT PACK
SH : II : Supply of following Spare Parts for existing Edward/Siemens make fire alarm system as and when required
Supply of auto dialer to connect to existing fire alarm system.
Supply of Analogue Addressable type Optical Smoke Detector as per UL / LPCB / FM / EN-54 complete with all accessories like base etc. to be installed under/above false ceiling, roof and concealed space, etc.suitable to connect in existing system complete as required. ( Make : EST/Siemens )
Supply of Analogue Addressable type Heat Detector (Fixed cum-rate of rise type) with range upto 60oC , as per UL / LPCB / FM / EN-54 complete with all fixing accessories like base, etc. to be installed under/above false ceiling, roof and concealed space, etc.suitable to connect in existing system complete as required.( Make EST/Siemens).
Supply of Analogue Addressable type Manual call point , as per UL / LPCB / FM / EN-54 complete with all fixing accessories like base, etc. to be installed under/above false ceiling, roof and concealed space, etc. complete as required.( Make : EST/ Siemens)
Supply of Hooter as per UL / LPCB / FM / EN-54 complete with all fixing accessories like base, etc. to be installed under/above false ceiling, roof and concealed space, etc. complete as required.
Supply of Response Indicator as per UL / LPCB / FM / EN-54 complete with all fixing accessories like base, etc. to be installed under/above false ceiling, roof and concealed space, etc. complete as required.
Supply of Control module / loop isolator / input output module for analogue addressable fire detection and alarm System , as per UL / LPCB / FM / EN-54 complete with all fixing accessories like base, etc. to be installed under/above false ceiling, roof and concealed space, etc. complete as required.
Supplying of 20 mm medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit with extra bends on surface as required:
Supplying of 2 x 1.5 sqmm FRLS unarmoured cable, 600 / 1000V rated with annealed copper conductor as per applicable IS standared complete in existing surface / recessed steel / PVC conduit as required.
Supply of Base Card suitable for existing Seimens make fire alarm addressable panel (Model : FHD 2002 R3)
Supply of Display Card suitable for existing Seimens make fire alarm addressable panel (Model : FHD 2002 R3)
Supply of Power Card suitable for existing Seimens make fire alarm addressable panel (Model : FHD 2002 R3)
Supply of External Loop Card suitable for existing Seimens make fire alarm addressable panel (Model : FHD 2002 R3)
Supply of Base Card suitable for existing Edward make fire alarm addressable panel (Model : EST 3X/ EST 3)
Supply of Display Card suitable for existing Edward make fire alarm addressable panel (Model : EST 3X/ EST 3)
Supply of Power Card suitable for existing Edward make fire alarm addressable panel (Model : EST 3X/ EST 3)
Supply of External Loop Card suitable for existing Edward make fire alarm addressable panel (Model : EST 3X/ EST 3)
SH : III : Supply of Spare Parts for fire fighting system as and when required
Refilling of following type Fire extinguishers including painting, repairing as needed, with necessary tests along with hydraulic tests etc. as required for smooth functioning of extinguishers including To & fro transportation.
ABC- 6 KG
Water -9 ltr
Foam - 9 ltr
Hydraulic Testing of 80 ltr/ 120 ltr seamless cylinder for Novec 1230 gas suppression system from CCOE approved factory including unloading and reloading the gas and make up the loss, transportation, insurance etc. complete as required.
Hydraulic Testing of 46.7 ltr seamless cylinder for Novec 1230 gas suppression system from CCOE approved factory including unloading and reloading the gas and make up the loss, transportation, insurance etc. complete as required.
Supply of pressure guage 0-200 PSI (0 - 14 Kg ) range, 3/8" BSP bottom entry, 4" dial weather proof with stainless steel internals, siphon tube amd ball valve including fittings, etc. complete as required
Supply of industrial type pressure switch having 1/4" BSP(F) connection IP:32 enclosure protection, phosphor bronze bellows as sensing element, SDPT contact system, switch rating 6A Inductive/lOA resistive 380 V AC, 0.2A Inductive/10A resistive 250V DC suit with ball valve etc. complete as required.
Providing, of 15mm dia pendent quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :
Supplying of 150mm dia double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts,washers, gaskets and conforming to IS 780 of following sizes as required
Supplying of 80 mm dia double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts,washers, gaskets and conforming to IS 780 of following sizes as required
Supplying of 65 mm dia double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts,washers, gaskets and conforming to IS 780 of following sizes as required
Providing, 150 mm dia of non-return valve of confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :
Providing 80 mm dia of non-return valve of confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings gunmetal duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required
Providing, laying, testing and commissioning of following C class heavy duty MS pipe conforming to IS: 1239 / IS: 3589 part - I including MS fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. with welded joints at water leakage places in the under ground with excvation of soil/hard stand/cement road/bituminous road etc or MS angle support on the surface including two coats of painting complete as per technical specifications.
80 mm dia
150 mm dia
SH : IV : Miscellanous items
Providing temporary illumination with standard coloured serial LED lamps sets on different occassions for the Terminal building, statue, trees and car parking garden with required cables as directed by the Engineer-In - Charge.(Containing minimum 50 Nos of lamps per set and quantiy of sets are required for each occassions will be decided by EIC).
Providing temporary multi coloured LED Flood light fitting on different occassions for the Terminal building, and statue with required cables as directed by the Engineer-In - Charge.(The quantity required for each occassion will be decided by E-I-C)
Youngmen Traders
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .