Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.9 LAccepted-AOC HOUSE NO 2 SATGAON MAIN ROAD NEAR BAILEY WATER FACTORY P O UDAYAN VIHAR DIST KAMRUP METRO GUWAHATI ASSAM 781171 | GUWAHATI | KAMRUP METRO | ASSAM | 781171 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹33.0 L+₹1.3 L (4.22%)Rejected-Finance P O NARANGI PIN 781026 ASSAM | NARANGI | KAMRUP METRO | ASSAM | 781026 | L2 | Rejected-Finance Other than Lowest Bidder | |
| 3 | L3₹33.8 L+₹2.1 L (6.74%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest Bidder | |
| 4 | L4₹34.4 L+₹2.7 L (8.62%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest Bidder | |
| 5 | L5₹35.9 L+₹4.3 L (13.4%)Rejected-Finance W D BUILDING JP ROAD BHARALUMUKH GUWAHATI 781009 ASSAM | KAMRUP METRO | ASSAM | 781009 | L5 | Rejected-Finance Other than Lowest Bidder |
Tender Value
₹41 L
EMD Value
₹82,000
Closing Date
12 Oct 2021, 6:00 pmClosed
GE NARANGI
GE Narangi C/O 99 APO
SPECIAL REPAIR TO BLDG NO P 37 PROVN OF SEWAGE LINE NEAR BLDG NO P 03 PROVN OF 01 MANHOLE AND 01 SOAK PIT NEAR BLDG NO P 35 AND 04 FIRE FIGHTING POINTS IN THE AOR OF AGE BR II UNDER GE NARANGI
2021_MES_473287_1
8678/B/E8
Open Tender
Civil Works
Item Rate
180 days
GE NARANGI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE NARANGI
₹82,000
Yes
27 Nov 2021
6 Sept 2021
15 Oct 2021
6 Sept 2021
12 Oct 2021
27 Sept 2021
Amount
Dismantling of asbestos cement sheet (Corrugated semi corrugated etc) as in roof covering complete all as specified and as directed.
S&F pre painted galvalume aluminum and zinc alloy coating with GI based corrugated steel sheet 0.50 mm thick of a colour having tensile strength of 550 Mpa as in roof covering / cladding to wall fixed with self tapping screws complete all as specified and directed.
S&F pre painted galvalume aluminum and zinc alloy coating with GI based plain steel sheet 0.50 mm thick of a colour having tensile strength of 550 Mpa as in ridges fixed with self tapping screws complete all as specified and directed.
M&L in repair suspended false ceiling using E-grid (exposed ceiling suspension system) of grid size 600x600mm with main runner 38mmx24mm and wall angle 24mmx24mm using 4mm thick Non Asbestos fiber cement designer board (E-Board classic) in a grid of GI system duly suspended with 4mm dia GI bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip providing positions for light fixtures air conditioning diffuser and ducts, sprinkler, smoke detectors etc. The main runners to be secured to structural soffits by hanger @ 1220mm maximum c/c, the last hanger at the end of each main runner should not be placed at more than 450mm from the adjucent wall, flush fitting 1220mm cross tee to be interlocked between main runners @ 610mm c/c so as to from 600x600mm grid and painted with two coats of OBD over a coat of primer before installing it on the grid complete all as specified and directed.
Demolition of brick /stone massonry work built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
M&L for brick work with sub class ‘B’ bricks (locally available best quality) straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 complete all as specified and as directed.
All as per item No. here-in-above but except bricks. (Serviceable bricks obtained from demolition shall be reused).
M&L for brick work with sub class ‘B’ bricks, (locally available best quality) straight or curved on plan to any radius in half brick thick wall, built in cement mortar 1:4 complete all as specified and as directed.
Taking down cement plaster on walls, chajja surfaces, etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
M&L for rendering 10 mm thick in CM (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed
M&L for rendering 15mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed
M&L for rendering 15mm thick in cement mortar (1:4) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed
M&L for 15mm thick rendering in cement mortar (1:4), in two layers, under coat of 10 mm thick & top of 5 mm thick, to other than fair faces of brick or concrete wall surfaces, top layer 5 mm thick mixed with water proofing compound (@ 3% by weight of cement or as per manufacture's instructions), finished even and smooth without using extra cement complete all as specified and as directed. (Note : Water proofing compound to be measured and paid separately as "Supply only".)
Supply only integral water proofing compound.
M&L for preparation of newly plastered surfaces of walls and applying three coats of white wash complete all as specified and directed.
M&L for preparation of old decoreted plastered surfaces of walls and applying one coat of white wash complete all as specified and directed.
M&L for preparation of newely plastered surface of walls and applying two coats of cement based paint over one coat of alkali resitant primer complete all as specified and directed.
M&L for preparation of old treated surfaces on walls and applying one coat of alkali resistant primer and a coat of wall care putty (not less than 1 mm thick), sanding the surfaces till smooth finish is obtained and finally applying two coats of cement based paint complete all as specified and directed.
M&L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and directed.
M&L for complete removal of existing treatment of walls and applying two coat of oil bound distemper over one coat of alkali resistant primer complete all as specified and as directed.
Dismantling timber scantling 40 Sqcm and over in section in frame work in any position complete all as specified and directed.
M&L second class hard wood in scantlings clean sawn timber in framed work complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) area n.exc. 1.5 Sqm each including builders hardware complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) area exceeding 1.5 Sqm but not exceeding 4 Sqm each including builders hardware complete all as specified and as directed.
S&F 30 mm thick flush shutter, solid core construction with particle board core and plywood face panel, commercial type on both side complete all as specified and directed.
S&F steel windows with side hung shutters glazed shutter incl both side openable (out side glazed window and inside fly proof window) including projecting type hinges with steel handle and steel peg stay complete with glazing bars and 12mm square bar or round bar of approved design welded to steel window frame dovetailed or welded complete all as specified and directed . (Note: Guard bar or square bar shall be measure and paid separately.)
S&F 1.25mm thick pressed steel frame of size 105x60mm for doors/windows with single rebates including necessary fixing lugs, hinges, lock strike plates, filling in concrete in hollow portion etc. complete all as specified and directed.
M&L PCC 1:3:6 type C0 using 12.5mm graded stone aggregate for filling of hollow portion of steel frames of any size complete all as specified and as directed.
M&L for plain cement concrete (1:3:6) type C1 (using 20 mm graded crushed stone aggregate) as in hold fast block or bed block complete all as specified and directed.
S&F 150mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
S&F 150mm in size extruded aluminium handles, fabricated type, anodised complete all as specified and directed.
S&F aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolt of extruded section or cast aluminium alloy and fixed 300mm long complete all as specified and directed
S&F stainless steel butt hinges 100 mm long complete all as directed.
S&F of stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless wire staples complete all as specified and as directed.
S&F 3 mm thick figured glass pin head type and glazing with oil putty in squares not exc 0.5 sqm in each pane complete all as specified and directed
M&L for preparation of new or previously untreated surfaces of wood and wood based surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for preparation of new or previously untreated surfaces of steel and steel based surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer complete all as specified and directed.
Demolition of cement concrete in ground floors and paving not exceeding 15cm thickness (below or above ground level) including removal of spoils/ demolished materials not exceeding 50m and depositing complete all as specified and directed.
M&L for 40 mm thick plain cement concrete 1:2:4, type B1, (using 20 mm graded stone aggregates) as in floor, finished the surface even and smooth without using extra cement complete all as specified and as directed.
M&L for 75 mm thick plain cement concrete (1:2:4) type B2 using (40 mm graded crushed stone aggregate) as in floors/ sub base of tiles/ floor of hard standing/ path etc complete all as specified and as directed.
M&L for providing 75 mm thick PCC (1:3:6) type C2 (using 40 mm graded crushed stone aggregate) as in plinth protection. Plinth protection shall be laid in alternate bays n exc 2 sqm, 10 mm thick joints shall be provided, joint shall be filled with bitumen mastic, bitumen mastic shall comprises of 1 part of hot bitumen 85/25 and 3 parts of sand all by weight finished cement concrete surface even and fair without using extra cement complete all as specified and as directed.
Dismantling floor, hearth and wall tiling including cement mortar bedding (but excluding backing), removing rubbish off the premises complete all as directed.
M&L for glazed ceramic coloured tiles 300mmx200mmx 6mm to 7mm thick, set and jointed in neat cement slurry and pointed in coloured cement as in vertical surfaces such as skirting, dado and risers to steps over and including 10 mm thick screed bed in cement mortar (1:4) complete all as specified and directed.
M & L for vitrified ceramic tiles, light shade, 10mm thick (square/rectangular) area of each tile not exceeding 0.36 sqm, laid in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles, over and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and as directed.
M & L for vitrified ceramic tiles, light shade, 10mm thick (square/rectangular) area of each tile not exceeding 0.36 sqm, as in vertical surfaces such as skirting, dados and risers to steps etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles, over and including 10mm thick screed bed in cement mortar 1:4 complete all as specified and as directed.
M&L coloured Non-skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match existing surfaces over and including 15mm thick screed bed in cement mortar (1:4) complete all as specified and as directed.
M&L coloured Non-skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match existing surfaces over and including 15mm thick screed bed in cement mortar (1:4) complete all as specified and directed.
M&L coloured Non-skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm as in skirting/dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match existing surfaces over and including 10mm thick screed bed in cement mortar (1:4) complete all as specified and directed.
M&L in rapair machine cut kota stone slab flooring 20 to 25 mm thick over cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab laid over and including 20 mm thick screed in cement mortar (1:4) including rubbing and polishing complete all as specified and as directed.
M&L in rapair machine cut kota stone 20 to 25 mm thick over cement screed base, laid and jointed with grey cement slurry mixed with pigment as in skirting /dado to match the shade of the slab over and including 10 mm thick screed in cement mortar (1:4) including rubbing and polishing complete all as specified and as directed.
S&F 18 to 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including dismantling the old stone slab complete all as specified and as directed.
M&L in repair pre polished chequered cement concrete tiles in floor, area exc 0.06 Sqm but not exc 0.11 Sqm, 25 mm thick with white cement and pigments of approved make jointed with cement slurry and pointed with white cement mixed with colour pigment to match with the tiles over and including screed bed of 20 mm thick cement mortar (1:4) complete all as specified and as directed.
Taking up or down 15 mm bore GI tubing from trenches / wall including all fittings segregated, cleaning and stacking the pipe for reuse at site if required complete all as specified and as directed.
S&F GI tubing15 mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
Refixing only old serviceable 15 mm bore Steel tubing and connections as obtained from taking up/down old steel tubing including provision of new fittings in new or old position to walls,ceiling, flooring etc. complete all as specified and as directed.
Taking up or down 20 mm bore GI tubing from trenches / wall including all fittings segregated, cleaning and stacking the pipe for reuse at site if required complete all as specified and as directed.
S&F GI tubing 20mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
Refixing only old serviceable 20 mm bore Steel tubing and connections as obtained from taking up/down old steel tubing including provision of new fittings in new or old position to walls,ceiling, flooring etc. complete all as specified and as directed.
S&F in repairs stop valves 15 mm dia cast copper alloy, fancy type chromium plated, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or unions complete all as specified and directed.
S&F in repairs Bib taps 15mm dia fancy type cast copper alloy chromium plated, with crutch or butter fly handles screwed down for iron pipe or for brass ferrule complete all as directed.
S&F in repair 15mm bore pillar taps cast copper alloy with capstan heads chromium plated screwed down high pressure with or without lettered 'HOT' or 'COLD' with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and directed.
S&F 1000 litres capacity rotational moulded polye-thylene water storage tanks triple layer ISI marked (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I with and including 20 mm bore dia -ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed etc including dismantling of old tank of any description complete all as specified and directed.
S&F in repair 20 mm dia ball brass valves, high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule complete all as specified and directed
S&F in repair stainless steel sink with drainage board made of 1mm thick stainless steel sheet for kitchen with plugs, washers, waste coupling and pipe, cast iron cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
S&F in repair vitreous china wash basin white flat back size 550 mm x 400mm including all fittings and CP Pillar tap, including cutting for and pinning in ends of brackets or erecting stand etc complete (waste coupling 32mm bore CP, 32mm bore PVC waste pipe, cast iron brackets etc shall be deemed to be included in the quoted rate) complete all as specified and directed.
S&F in repair 15mm dia PVC connection pipe 600mmm with PTMTnuts complete all as specified and directed
S&F in repairs aluminium body door closer hydraulically regulated, designation No. 3, universal type and of weight between 61 to 80 kg suitable for door shutters upto 1M width of approved make etc complete all as specified and directed
S&F in repair Waste coupling of PTMT (half or full threaded) Minimum weight 40 to 60 gms complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
S&F roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete all as specified and as directed.
S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 graded St 240 with one shop coat of zinc chrome primer paint complete all as specified and directed.
S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc, complete, drilled for fixing of steel sheeting or other covering Doors etc, to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing complete all as specified and directed. Conforming to Fe-410-W(Gde-E-250)quality-B complete all as specified and directed. .
S&F mild steel Framed work such as grills, gratings, angle iron, mild steel sheets, mild steel round bar, MS flat iron etc.. for chowkhats or doors shutters or windows etc with ends of bars shouldered and/or riveted, wlded or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed.
S&F of mild steel, plain black sheet 1.25mm thick in wall cladding, steel gates and similar work, cut to size, holes punched, including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40mm lap joints with riveted or welded seams, including bending or turning up, mitered angles etc as required complete all as specified and as directed.
S&F 0.80 mm thick plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and as directed
Anodized aluminium sliding glazed window shutter (double leaf glazed shutter and single leaf mosquito proof shutter each in single frame work) without sash bars with anodized aluminium shutter of section 40.00mmx20.00mmx1.10mm thick and window chowkat of section 92.00mmx29.50mmx1.20mm thick including necessary jointing cleats, glazing clips, rubber packing, snap beading, screws, handle, tower bolts and locking arrangement etc. and including 4mm thick sheet glass, tinted quality on panel and stainless steel wirecloth or aluminium anodized wire cloth for mosquito proofing, 0.45mm nominal dia and average width of aperture 1.40mm fixed with aluminium screws and tacks and making good to disturbed surfaces complete all as specified and as directed.
Anodized aluminium push pull type partly paneled and partly glazed door shutter (single leaf / double leaf) having top rail of section (85 x44.45 x2)mm, bottom rail of section (85 x 44.45 x2)mm, door verticals of section (44.45 x44.45 x2)mm and lock rail of section (85 mmx44.45 x2)mm with aluminium anodized chowkats of section (63.50 x33.10 x2.50)mm including necessary jointing cleats, glazing clips, rubber packing, snap beading, screws, handle and locking arrangement etc. including 12mm thick pre laminated particle board, interior grade pre laminated with decorative face laminations both sides on bottom panel and 5.5 mm thick float glass tinted quality on top panel complete all as specified and as directed. (Note : Door closer shall be measured and paid separately)
M&L for 2nd class hardwood Weather boarding, clean sawn, plain, 20mm thick or feather edged 15 mm to 20mm thick and fixed with 30mm laps complete all as specified and directed.
Demolition of cement concrete (Reinforced) as in roof, floors (other than ground floors), beams, staircase, landing, chajjas, shelves and other similar suspended works complete all as specified and as directed.
M&L for Reinforced cement concrete 1:2:4 type B-1 (20 mm graded stone aggregate) as in slab supported on wall , beam and column in floor, roofs, landings, balconies, canopies deck slab and in selves and the like complete all as specified and as directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and as asdirected.
M&L for mild steel TMT bars 6 to 8 mm dia as in reinforcement, cut to length, bent to shape required, incl cranking bending spirally for hooping for columns and binding with MS wire (annealed) not less than 0.9 mm dia or securing with clips and complete all as specified and asdirected.
M&L for mild steel TMT bars10 mm dia and over as in reinforcement, cut to length, bent to shape required, incl cranking bending spirally for hooping for columns and binding with MS wire (annealed) not less than 0.9 mm dia or securing with clips and complete all as specified and asdirected.
M&L for mild steel TMT bars 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders complete all as specified and as directed.
Excavation over area, n. exc 1.5m in depth and getting out in soft/ loose soil complete all as specified and directed.
Excavation over area exc 1.5m in depth but n exc 3m and getting out in soft/ loose soil complete all as specified and directed.
Excavation in trenches not exc 1.50 m wide and not exc 1.50 m deep for foundation or for shafts, wells cesspits, man holes, laying of cable etc not exc 10 Sqm on plan and n exc 1.5m in depth and getting out in soft / loose soil complete all as specified and as directed.
Returning, filling, in soil including spreading, levelling, watering and well ramming in layers n.exc. 25cm thick complete all as specified and as directed.
Removing excavated soil to distance not exc. 50 m and depositing where directed at a level not exc. 1.5 m above the starting point etc complete all as specified and as directed.
M&L for PCC 1:2:4, type B2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete etc. complete all as specified and as directed.
M&L for plain cement concrete 1:2:4, type B-1, using 20 mm graded stone aggregate as in benching, coping, haunching between roof and wall or parapet wall, between chajja and wall etc, finishing the exposed surface of concrete even & fair . including all necessary form work all as specified and as directed.
M&L for precast cement concrete Type B-1 1:2:4 (using 20mm gradded stone aggregate) set in CM (1:4) as in in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces complete all as specified and as directed.
M&L for concrete bed in cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) for drain pipes, 150 mm bore including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed.
M&L for PCC 1:4:8, type D-2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete etc. complete all as specified and as directed.
S&F of salt glazed stoneware drain pipes, 150 mm bore, laid in trenches and jointed complete all as specified and as directed.
S&F in repairs 110 mm dia PVC (SWR) pipes, single socketed in any length with rubber ring joints laid in trenches or in floor as in waste /soil / vent pipes etc. complete all as specified and directed
S&F 110 mm dia PVC (SWR) bends of any radius complete all as specified and directed
S&F PVC (SWR) pipes 75mm dia single socketed, in any length fixed vertically as in vent pipes complete all as directed and as specified.
S&F PVC (SWR) vent cowl of 75mm dia complete all as directed.
Cutting into existing manhole for connecting new drain pipe of any size making good to pipe and rendering, cutting out existing benching for and forming brench chennel in cement concrete 1:2:4 type B-1 smooth finished etc complete all as specified and directed.
M&L for brick bats filling in soak pit complete all as specified and as directed.
Surface excavation n.exc 30cm deep & averaging 15cm deep & getting out in soft/loose soil complete all as specified and as directed.
M&L for hardcore of broken or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface etc complete all as directed.
M&L for 100mm thick PCC 1:2:4 Type B-2 (using 40mm graded crushed stone aggregate) as in path/paving/ hard standing and finishing the surfaces even and fair without using extra cement complete all as specified and as directed.
M&L for 75mm thick PCC 1:4:8, type D2 (using 40mm graded stone aggregates) as in sub base for path/paving / hard standing / floor etc. complete all as specified and as directed.
M&L for 25 mm thick PCC 1:2:4, type B0 using (12.5 mm graded stone aggregate) as in floors finished the concrete surface even and smooth without using extra cement complete all as specified and as directed.
Taking out carefully Precast RCC cover slab of septic tank, excavating and taking out sludge including foul water in a closed container by mechanical process or manual process, transporting to a distance exc 250 m but not exc 500 m and depositing the same in excavated earthen pit of sufficient size and depth in any type of soil within the defence land, where directed, returning, filling in earth into excavated pit after every disposal of sludge, cleaning inspection pit, sludge chamber inlet and outlet pipe, cleaning MS rungs and also applying one coat of linsed oil complete for septic tank capacity from 25 user to 500 users, cleaning the septic tank with fresh water complete all as specified and as directed. Note : (i) Depth shall be measured after bailing out water from septic tank (ii) Cost of bailing out water shall be deemed to be included in the quoted rate.)
Taking out carefully the cover slab of each manhole of depth from 1.0 m to 2.0 metre and removing the sludge by mechanical process or manual process, transporting to a distance exc 250 m but not exc 500 m and depositing the same in excavated earthen pit of sufficient size and depth in any type of soil within the defence land, where directed, including returning, filling of earth in excavated pit after every disposal of sludge and also applying one coat of linsed oil and cleaning with fresh water, placing the cover slab in position complete all as specified and as directed.
Taking down carefully aluminium/ copper point wiring for light/fan/ socket/bell or power point incl. All fittings i.e. switch, sockets, ceiling rose, regulators, batten holders, etc. complete removing materials to store for keeping in safe custody site or handed over to contractor as schedule of credit and making good disturbed surfaces of walls, floors, etc complete all as directed by Engineer-in-Charge.
M&L point wiring with PVC insulated and unsheathed cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts, FRLS grade cable conforming to IS-694 1990 drawn in concealed conduit including 1.5 sqmm single core PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for One light or fan point controlled by one 5 Amps switch one way complete all as specified and directed.
All same as per item No 111 here-in-before but for One 3 pin 5 Amp switch socket outlet on independent board.
All same as per item No 111 here-in-before but for One 3 pin 5 Amp switch socket outlet on same board with other switches.
All same as per item No 111 here-in-before but wiring with 2.5 sqmm size single core multistranded copper conductor cable for 6 pin 15 Amps switch socket combination outlet on independent board with 2.5 sqmm PVC insulated and unsheathed copper conductor as earth and connected to earth dolly.
S&F switch piano, flush type single pole one way 5 Amps 230 volt complete all as directed.
S&F socket outlet 3 pin, 2-in-1, 5 Amps flush type complete all as directed.
S&F switch socket combination outlet 5 pin, 2-in-1, 5 Amp flush type complete all as directed.
S&F switch socket combination multipurpose, 2 in 1, 6 pin, 5 & 15 Amp flush type complete all as directed.
S&F ceiling rose surface bakelite 65x50mm three terminal complete all as directed.
S&F lamp holder insulated PVC/ Polycarbonate/ bakelite body, with back plate suitable for batten fitting or PVC round or squre box, complete all as directed
S&F stepped type electronic fan regulator, two module size, flush type complete all as directed.
S&F in repairs Environmental friendly, ultra modern, energy saving, surface mounted, decorative hexagonal bulk head black-lit LED10 W -IP-66 luminaire comprising of high brightness LEDs complete all as specified and as directed. Make:- Havells Model HEXAFT10WLED857SSYMBOPC or equivalent Model of make : Philips / Crompton /GE.
S&F in repairs, regal batten for LED Tube rod pre-wired including LED tube double sided 1x20W connecting up with aluminium housing and sheathed 1100 volt grade flexible copper cable & fix on 2 no. of PVC block complete all as directed. (Make:- Havells, Model: REGALBATTENT8UPTO1X22WDSBSWH+ CRSTAL1213T8DSTL20WLED865SGLASS or equivalent model of make Bajaj/ Philips /GE/Crompton)
S&F in repairs, LED box type fitting pre-wired including LED tube 1x10W connecting up with PVC insulated and sheathed 1100 volt grade flexible copper cable and fix on 2 no of PVC block complete all as directed. Make:- Jaguar Model-LGLZ01X010XC/ LGLZ01X010XN/LGLZ01X010XW or Make:- Havells Model-LUMILINEPLUSBS10WLED865SPCSS or equivalent model of make Philips /GE/Cromptonor equivalent model of make Philips /GE/Crompton
S&F in repairs wall mounted decorative luminaire in design mesh suitable for 9W LED lamp B22 base ,including lamp 15watt complete all as specified and as directed. Make -Havells, cat no-LHDL07150099 or equivalent in crompton, Bajaj, Jaquar
S&F in repairs LED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with highefficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed. Make -Havells /crompton / Bajaj/ Jaquar
S&F in repair MCCB DB IP-43 of sheet metal enclosure double door VTPN 4 way with 250 Amps rated copper bus bar 415 volt and grouted in wall with PCC (1:2:4) type B-1 using 20 mm graded stone aggregate complete all as specified and directed. (Make-Legrand Cat No-5077 45 or equivalent of Siemens/Schnider/L&T)
S & F in repairs, SPN DBs 8 Ways, double door, protection class IP-43 suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 100 Amp rating copper bus bar complete all as specified and as directed. Make :- Legrand Cat No 5076 11 or equivalent model in Siemens / Schneider
S&F in repairs, MCBs, SPN 6 to 32 Amps, 10 KA, 'C' curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. Make :- Legrand Model 4086 09 to 17 or equivalent model in Siemens / Schneider/L&T
S&F in repairs, MCBs, SP 6 to 32 Amps, 10 KA, 'C' curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. Make :- Legrand Model 4085 90 to 95 orequivalent model in Siemens / Schneider/L&T
S&F in repair MCB TPN 40 to 100 Amps 415 V, 50 Hz,10 kA,C-series complete all as specified and directed. (Make :- Legrand/ Siemens/Schnider/L&T)
M&L for Sub main wiring with 2 runs of 4.0 sqmm, single core, FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 4.0 sqmm single core FR-LSH PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. (Note: 2 run of 4 Sqmm cable and 1 run of 4 Sqmm cable along with conduit all together shall be measured as one unit.)
S&F in repairs LED building security luminaries 48 Watts WSPD energy saving and environmental friendly long life LED light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having IP65 protection and Impact resistance of IK07 with 10KV Built-in Surge Protection Device including testing on completion complete all as specified and as directed. Make: Havells CAT No. ENDURAPEARNEOSL48WLED757SASYTOPC or equivalent of Philips/Wipro/CG
M&L for GI bracket made out of 40 mm bore medium grade GI Pipe with two sets clamps, with nuts and bolts, bend to shape all as directed, length of GI Pipe shall not be less than 2.0 metre for fixing of light fittings including taking out old bracket complete all as specified and as directed.
M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 16 sqmm 3 core laid in trenches /floor or fixed on wall /pole in including brass compression cable glands, terminal lugs etc, complete all as specified and as directed.
M&L for GI pipe light grade 25mm bore with all fittings to be laid in trenches or in floors, walls, pole etc with iron clamp 25x3mm, nut bolt, washersted one complete all as speciffied and as directed.
Supply and spreading clean dry river sand in cable trenches as in cable cushioning complete all as specified and as directed. (Note: Punned down thickness should be measured and paid)
M&L for Sub class ‘B’ old size well burnt brick laid flate in trenches over the cable for protection of LT cable complete all as specified and as directed.
Taking down ceiling fan exhaust fan/ wall fan of any sweep of any make and transporting from any location to MES E/M store yard, and refixing on same location or other location carefully after repairing, washing by petrol, greasing, including rewinding the armature (Rotor) with super enamelled copper wire of suitable size, replacement of defective unserviceable parts (wherever necessary) assembling the same including two coats of synthetic enamel spray painting and testing the fan on full load to entire satisfaction of Engineer-in-Charge complete all as specified and as directed.
M&L for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 m deep below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI earth lead wire 4 mm dia or 8 SWG bolted (with GI nuts, bolts & check nuts) and earth plate electrode at one end and connected to main switch board/ DBs etc. at the other, earth strip encased(protected) in and including 15 mm bore GI pipe medium grade with all fittings from top of electrode to main switch board/ DBs etc fixed with and including 25 x 6mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-2 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work complete all as specified and shown in electrical plate No 3 of SSR Pt-I.
M/S Narayan Chandra Das
U S CONSTRUCTION
M/S MANOJ PAUL
PK ENGINEERING
KAMAKHYA CONSTRUCTION & BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .