Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.2 CrAccepted-AOC P J B ROAD PRASANTI APPARTMENT 103 P O CHEMIKUTHI PS CHANDMARI DIST KAMRUP M ASSAM | KAMRUP M | ASSAM | ₹3.2 Cr Quoted ₹3.6 Cr | L1 | Accepted-AOC Work Order Issued |
Tender Value
₹3.0 Cr
EMD Value
₹6.0 L
Closing Date
19 Feb 2021, 2:00 pmClosed
CE, PWD (Bldg), Assam, Chandmari, Ghy-3
O/O The CE, PWD (Bldg), Assam, Chandmari, Ghy-3
Construction of Gallery and football Ground of Bir Lachit Stadium at Chapakhowa, Sadiya, Tinsukia
2021_PWBNH_20916_1
CS/T/BD/14/2020/8 Bir Lachit Stadium Sadiya
Open Tender
Civil Works - Building
Item Rate
365 days
Tinsukia
Please refer Tender documents.
6 documents required · 6 mandatory
₹10,000
Assam State Road Board Maintenance (Road) Fund
₹6.0 L
Yes
O/O The CE, PWD (Bldg), Assam, Chandmari, Ghy-3
17 Jan 2022
4 Feb 2021
19 Feb 2021
4 Feb 2021
19 Feb 2021
4 Feb 2021
5 Feb 2021
Amount
Earth work in Excavation for foundation trenches of walls , Retaining walls, footing of column , steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work , breaking clods in return filling , dressing Watering and ramming etc.and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. Upto a depth of 2 mts. below the existing Ground Level In ordinary Soil
Earth /Sand filling in plinth in layers not more than 150 mm thick including necessary carriage , watering , ramming etc. completed and specified including payment of land compensation , forest royalty , sales tax and other duties and taxes as may be necessary. (a) With earth or silt or sand obtained by head load with lead upto 90m and lift upto 2m.
(c) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading.
Providing brick soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. Brick on flat soling.
Plain cement concrete works with course aggregate of sizes 13mm to 32mm in foundation bed for footing steps, for walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (Shuttering where necessary shall be measured and paid separately) In proportion- 1 cement : 3 sand : 6 coarse aggregates by volume
Plain cement concrete floor base in prop 1:3:6 laid in alternate bays as specified with coarse agg. of size 13mm to 32mm including dewatering if necessary, and curing etc. complete. c) 100mm thick
Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine In substructure up to plinth level Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. P) Using admixture, plasticiser etc for air entraining, water reducing purposes including addition of agent for changing normal setting time of concrete as required. c) M25 grade concrete
In super structure from plinth level up to 1st floor level. Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. P) Using admixture, plasticiser etc c) M25 grade concrete
Extra over item Nos. 2.2.1 (I) (B), above for each subsequent floor or part thereof above the 1st floor level to 2nd floor level
Extra over item Nos. 2.2.1 (I) (B), above for each subsequent floor or part thereof above the 2nd floor level to 3rd floor level
Providing formwork of ordinary timber planking so as to give a rough finish including centering, shuttering , strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0 m and removal of the same for cast - in - situ reinforced concrete and plain concrete work: In Substructure upto Plinth Level : Foundation, footings, base of columns, pile cap, raft and mass concrete works etc. Using 25mm thick plank
Sides of tie beams, plinth beams, grade beams etc. at or below plinth level Using 25mm thick plank
In Superstructure from Plinth Level upto Floor Level-1: Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face
Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties.(a) For depth not exceeding 1.0M.
Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like.(a) Floors etc. upto 200mm in thickness.
Staircase with sloping or stepped soffits including risers and stringers but excluding Landing.
Extra for each subsequent floor or part thereof above the First Floor level to 2nd floor level as mentioned in item no. 3.2.1 .
Extra for each subsequent floor or part thereof above the 2nd Floor level to 3rd floor level as mentioned in item no. 3.2.1 .
230mm thick brick wall in cement morter with 1st class brick including racking out joints and curing complete as directed in structure (I) In Sub-structure upto plinth level including dewatering if necessary(c). In proportion 1:5.
100mm thick wall using Cellular Light Weight concrete block of Size 500x200x100mm conforming to IS-2185 Pt-3 or pt-4 in cement mortar of proportion 1: 5 including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding rod is to be provided at every 3 course interval and will be measured and paid separately)
Extra for CC block walling on item no 4.3.5 for each subsequent floor or part thereof above the 1st floor level.
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. A) On rough sideb) In cement mortar 1:4
B) On fair side b) In cement mortar 1:4
20 mm thick Cement plaster in two coats on single or half brick walls for interior plastering up to 1st floor level including arises, internal rounded angles,chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. A) On rough side (backing coat 15 mm and finishing coat 5mm thick) b) In cement mortar 1:4
Extra over item no 6.2.1 to 6.2.3 for plastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed.
Extra over item no 6.2.1to 6.2.3 for interior plastering above 1st floor level for every addl floor or part thereof including curing complete as directed. a) On Single coat plaster
Extra over item no 6.2.1 to 6.2.3 for exterior plastering over wall up to a height of 1st floor level above ground level including curing complete as directed. b) On two coat plaster
Extra over item no 6.2.1 to 6.2.3 for exterior plastering over wall for every addl floor or part thereof beyond 1st floor level including curing complete as directed. b) On two coat plaster
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL (ii)Super Ductile (SD) TMT reinforcement bars
Extra over item 18.1.1(a) for each subsequent floor or part thereof 1st floor to 2nd floor level.
Providing two coats of Birla White Wall Care Putty (Water Resistant White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm) (I) Thickness = 1.5 mm
a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth - Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
Extra for every subsequent coat of wall painting with acrylic emulsion paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) - Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
Finishing wall with two coats of acrylic emulsion exterior coatings of Unicem "Rakshak" brand of required shade by thinning 1ltr. of paint with 750ml of water to give an even shade after throughly brooming the surfaces to remove all dirt and remains of loose powdered materials as specified and directed by the department.
Extra over item no.13.5.2 above for every subsequent coat of acrylic emulsion exterior coatings of Unicem 'Rakshak' brand of required shade.
Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping. (i).Surfaces over 100mm in width or girth. b). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Providing and fixing Flush door shutters solid core construction with frame of 1st class hard wood with cross band and face veneered ply wood face panel conforming to relevent to IS Code including oxidised iron butt hinges (100 mm X 75 mm X 3.5 mm) 6 nos. with necessary wood screws. Non Decorative Type and Block Board core (i) 35 mm thick with panel inserts of 20 mm thick.
Providing, fitting and fixing anodised aluminium sliding windows and ventilators of standard sections of approved brand without horizontal glazing bars, joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels. (a)2 Track sliding window (i)6mm clear glass
(b)3 Track sliding window i) 6 mm clear glass
Providing, fitting and fixing M.S. grill of required pattern for windows/ clerestory windows/ openingwith M.S. flats at required spacing in frame all round, squre or round M.S. bars with round headed bolts and nuts or screws.. I . Plain grill (c) Fixed to Brickwork/P.C.C/R.C.C.
Supplying, fitting and fixing double leaf heavy duty iron gate, frame made from 50mm x 6mm M.S. flat iron with another horizontal flat at the middle, 20mm dia M.S bars at 200mm apart from bottom flat to top flat and 20 mm dia M.S. bars at 200mm apart from bottom flat to middle flat including drilling, welding etc. complete. All vertical bars are to be protruded at least 100mm above the middle and top flat is to be flattended and pointed as directed. Necessary locking arrangement on both faces, arrangement for temporary closing the gate and 2 nos.( minium) strong iron hinges of M.S bars and flat of same sizes on each leaf to be embeded in C.C brick pillars as necessary including a red oxide painting to all iron works as directed and specified. (Separate payment will be made for posts).
Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) a) Normal range Somany/ Orient/Nitco /Varmora/VITA/ Marbito/ Make ii) Of size 600mmx600mm and above
Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement complete at all level as specified and directed. VITRIFIED TILES iii)Executive range-2 (Sizes 600 mm x600mm and above) i) Nitco made/Quotone/Somany a)Imperia Series- Gres Tiles
25 mm thick cement concrete topping 1:2:4 (1cement : 2 coarse sand : 4 coarse aggregate of 12 mm nominal size) finished with a floating coat of neat cement finish to be laid in panels including curing complete as directed.
Providing polished ceramic wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (Walls means both interior and exterior walls).c) Delux range Somany/ Orient/Nitco/Varmora Makeiv) Of size 300mmx600mm and above
Kota-stone slab flooring of 18 mm thick over 20mm thick base of cement plaster 1:6 (1 cement : 6 coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. (2) 600mm x 900mm and above
Kota stone slab of 18 mm thick in riser of steps, skirting, dado and pillars laid with 10mm thick cement plaster 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs including rubbing and polishing complete. (2) 600mm x 900mm and above
Providing 18mm thick Granite slab on vertical face of pedestal laid over 10 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete as directed with approved quality of shade.
Providing polished granite slab of approved quality, size, shape and thickness not less than 18 mm on floors, skirtings, treads and risers of steps over cement mortar bed 15 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile Choksey/Sika/Pedelite/Rouf) /white cement slurry mixed with approved pigment to match the shade of granite slab, complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of slab and as approved and directed by the Department). (iii) Deluxe Quality (i) With Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)
Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished ) m) Mortice lock vertical type iii) 100mm(Godrej with handle (6 lever)
iv) Aldrop with In built Lock-6 lever kadi tala(Godrej Make)
t) Door stopper with rubber stopper
Supplying, fitting, fixing Stainless Steel fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary c.p. brass screws etc. complete.( bright natural matt & satin finished ) b) Tower Bolt i) 300mm x 10mm
Providing,fitting and fixing Door closer of various type UL listed and fire rated good quality depending on the door specification.Types like single speed,Double Speed,Heavy Duty etc are available and as directed & specified by the department. A) Godrej c) Heavy Duty Door Closer( size 180 mm x 65mm x 64mm)
Preparing the RCC surface in roof slab, chajjas, terraces, sunken slabs, septic tank, OH tank, raft slab, walls etc. by thoroughly cleaning with wire brush etc. followed by power washing for making the surface absolutely free from any foreign particles like dust, oil, grease etc. and allowing surface to dry complete as directed at all levels.
Supplying, mixing, laying and applying the following waterproofing systems over Raft slabs, Roof slabs, Terraces etc. including curing complete as specified and directed by the Department at all levels.: (i) 1mm thick single coat of Master Crete M-81 of Choksey Chemicals /Dr. Sealkit Sealcrete (Asian Chemicals)/RHEOMIX 131of BASF mixed with cement in the ratio 1:2 as a prime coat. (ii) 3mm thick Polymer modified mortar - Cement sand mortar (in prop 1:3) mixed with Master Crete M-81/Dr. Sealkit Sealcrete (Asian Chemicals)/RHEOMIX 131of BASF @ 15% by weight of cement. (iii) 1mm thick coat of Master Crete M-81 /Dr. Sealkit Sealcrete (Asian Chemicals)/RHEOMIX 131of BASF mixed with cement in the ratio 1:2 as final coat. (A) Using Master Crete M-81 of Choksey Chemicals /Dr. Sealkit Sealcrete (Asian Chemicals)
Pre construction anti - termite treatment at the bottom of foundation pits and walls on either side up to a height of 300mm from bottom of the excavation made for column plinth beam, wall, trenches etc. by applying the emulsion @ 5 (five) litres per square meter of the surface area before starting construction work (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Construction of Granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per Clause 401 of MoRTH specifications (with an initial lead of 5 km) (including cost of testing of materials at site and laboratory as directed by the deptt.) (b)Using Grading II material
Providing, laying, sopreading and compacting stione aggregates of specific size to water bound mecadam specification including spreading in uniform thickness, hand-packing, rolling with vibratoy roller8-10 tonnes in stages to proper grade and camber, applying and brooming Type -A (13.2 mm agg.) screening/binding material to filled up the interstices of coarse aggregate watering and compacting to the reqd. density( with all initial lead of 5.0 Km) By Manual means Grading II using Screening Type B(11.2mm agg)
Providing and laying of inter locking concrete block pavement (ICBP) with cement concrete paver blocks as per IS 15658-2006 of thickness 80mm and 28 days compressive strength not less than 40 N/m over a layer of bedding sand of compacted thickness 30mm, laid either in stretcher/ running/ herringbone pattern of bonds as directed by the engineer and in proper level and grade and compacted with appropriate equipment such as plat vibrator along with spreading of a thin layer of joint filling sand to fill up the gaps between blocks including construction of edge restraint wherever required complete as per drawings and Technical specification clause 1504 of MORD.
Providing plinth protection 50mm thick to cement concrete 1 : 3 : 6 with coarse agg.of 20mm nominal size including finishing the surface with 10mm thick cement plaster in proportion 1:3 with a floting coat of neat cement finished.
Providing and fixing in position collapsible M.S. shutters with vertical channels 20mmx10mmx2mm braced with flat iron diagonals 20mmx5mm size with top and bottom rails of T-iron 40mmx40mmx6mm with 38mm dia steel pulleys complete with bolts and nuts, locking arrangements, stoppers, handles including applying a priming coat of red lead paint.
Providing drain with cement concrete (1:3:6) 10cm thick sides 10cm thick bed over brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. ii)300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
Supplying, fitting and fixing chain link fencing of 10 S.W.G, G.I. Wire 50mm x50mm mesh fitted to M.S angle iron post at 2000mm apart of specification detailed below including supplying, fitting and fixing hooks, eye bolts with nuts, staples and bolts including three horizontal lines of G.I wire 10 S.W.G at top,middle and bottom and with one vertical line to each fencing post for keeping the fencing tight and erect complete, including one coat of primer painting to M.S angle iron post in P.C.C base etc. with following. a) Corner and end posts with M.S angle of size 50mmx50mmx 5mm and length not less than 1800mm only duly slotted and bottom torqued with two numbers as stay posts. b). Intermediate post with M.S angle of size 40mmx40mmx5mm and length not less than 1800mm only duly slotted and bottom torqued and splayed. c).Stay post with M.S angle of size 35 mmx35mmx5mm and length not less than 1800mm duly slotted and bottom torqued and splayed. All M.S angle iron posts are to be fitted to P.C.C base embedded not less than 600mm (P.C.C. work shall be measured and paid separately).
Providing fiting and fixing of Wood Plastic Composite (WPC) door frames of natural and brown colour of 100mm x 65 mm section and density not less than 900 kg/ cum, single rebated rectangular section including joining of top mullion and vertical members with mitred joint and fixing to the wall jamb with MS holdfasts/ Metal Screw and metal rawl plug.
Supply and installation of Merino /Greenlam (Nylon) series cubicles of width and depth as per specifications/ site drawings. Cubicle height will be 2003 mm. Made from solid grade compact high pressure laminate as per IS:2046 and EN-438 manufactured under high specific pressure > 5 MPa and temperature >120°C with bunch of kraft papers impregnated with thermosetting phenolic resin and decorative papers made of Alpha cellulose fiber impregnated with thermosetting melamine resin which provide superior scratch, abrasion, heat, chemical, impact, graffiti & moisture resistance along with anti-bacterial properties. Panels have a black core that when machined, presents a distinctive black edge. All doors will be of single colour and made of 12 mm thick HPL compact panel. The doors will have chamfered edges. Each door will be supported by 3 no.s Nylon PA-6 made hinges affixed to the pilasters. Nylon PA-6 made coat hook and lock set are provided with each door. All pilasters will be made of 12 mm thick HPL compact panel with chamfered edge and completed with stainless steel made thumb turn lock set. Aluminum made door stopper profiles with rubber linings for dampening the noise while door closing will be provided at the vertical ends of the pilasters. Pilasters will be anchored to the floor using Nylon PA-6 made adjustable legs .The bottom gap is 100-150 mm. All intermediate partitions or dividers will be made of 12 mm thick HPL compact laminate panels. They are affixed with aluminium made U-channel at their ends for ultimate stability of the system. Design no. as specified by Arch. / Engr. in suede finish. Size of panels to be as per drawing.
Supply Fitting and Fixing of 60mm x 240mm x 11 mm thick clay brick cladding material of Tunch Bricks make with 80% of clay composition and maximum size variation of 1.5% and water absorbtion quality of < 6%, Breaking strength of >800N, modulus rupture of avg>= 13, with acid and alkali resistance properties, to be fixed with average 3-6mm thik Adhesive of Endura make on a finished and smooth surface without mortar droppings and other foreign matter and sand papered smooth. The tile joints are not to be grouted with any filler material and to be kept as grooves at all levels as directed and approved by the department.
Supply, Installation, Fixing of DRY CHEMICAL POWDER Fire Extinguisher confirming to IS: 2171 with ISI mark and CO2 cartridge will be confirming to IS: 4947 with ISI mark, Powder will be confirming to IS: 4308 with ISI Mark (10 kg) BRAND : FIRESTOP / FIREND / FIRE SHIELD
Supply, Installation, Fixing of MECHANICAL FOAM (AFFF) Fire Extinguisher confirming to IS: 10204 with ISI Mark and CO2 Cartridge will be confirming to IS: 4947 with ISI mark, (AFFF) will be confirming to IS: 4989 with ISI Mark.(9 LTRS) BRAND : FIRESTOP / FIREND / FIRE SHIELD
Supply, Installation, Fixing of ABC Stored Pressure Fire Extinguisher with built – In pressure Gauge to know the Ready ness of the Extinguisher Squeeze Grip Handle As per IS:13849 with ISI mark (05 kg capacity) BRAND : FIRESTOP / FIREND / FIRE SHIELD
Providing fitting and fixing Vitreous china wall hang water closet (European type W.C pan 400mm high) with seat and lead ,CP brass hinges and rubber buffers , CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately) ii) Hindware make a) White (i) Constellation (inclusive of seat cover and fittings) (P Trap)
Providing fitting and fixing Vitreous china Dual Flush / Floor Mounted Coupled / Extended water closet (European type W.C pan 400mm high) with seat and lead ,CP brass hinges and rubber buffers , CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately) B) Hindware make a) White (i) Constellation (inclusive of seat cover and fittings) (P Trap)
Providing fitting and fixing vitreous china flat back type lipped front urinal basin with standard flush pipe and CP brass spreader andbrass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required. B) Hindware make a) White (ii) Dyna (Cat. No.60010)
Supplying fiting and fixing vitreous china division plate including fitting and fixing compete as directed and specified. (ii) Hindware Make (a) White (i) Division Plate 680 x 300 (Cat. No.61001)
Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately) Under Counter Basin (B) Hindware Make (a) White (i) Lara (Cat. No.10095)
Providing fitting and fixing of chrome plated Jaquar make soap dish (cat no ACN 1131 N)
Providing fitting and fixing of chrome plated 600 mm long Jaquar make Towel rail complete as directed.
Providing fitting and fixing of Jaquar make chrome plated Towel ring complete as directed.
Providing, fitting and fixing Chrome Plated robe hook complete as directed and specified. (a) Jaquar make (i) Continental (Cat.No. ACN-1191N)
Providing fitting and fixing Decorative Mirror complete as directed and specified.Parryware Make Size 800mm x 600mm
Providing, fitting and fixing Chrome Plated waste coupling complete as directed and specified. (a) Jaquar Make (i) 32mm (HT/FT) (Cat.No.ALD-705 / 709)
Providing fitting and fixing PVC cowel of ISI make complete as directed and specified. (i) 160mm dia. PVC cowel of ISI make
(ii) 110mm dia. PVC cowel of ISI make
C.P. Grating (ii) 110mm dia
Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately) (ii)Jaquare make (a)Continental /Clarion (i)Standard
(iii)2-Way bib cock
(i)Jaquar (a) Continental / Clarion (ii)15mm dia( Angular stop cock )
(iv) 15mm dia, (Concealed stop cock extra heavy with adjustable wall flange )
Supplying and fitting fixing C.P. pillar cock of 15mm dia of approved brand as specified and directed. (ii)Jaguar make (a) Continental
Supplying fitting and fixing Chrome Plated (C.P.) sink cock of approved brand as directed and specified. (G.I. & C.P pipes will be measured and paid separately) Jaquar brand a) Continental / Clarion i) Sink cock with swinging casted spout
Supplying fitting and fixing Chrome Plated (C.P.) shower 15mm dia. Of approved brand as directed and specified. (Pipes will be measured and paid separately) (iii)Jaquar make a) Continental (ii) Shower arm 190mm long heavy casted body with wall flange
Supplying fitting and fixing Telephonic Chrome Plated (C.P.) shower of approved brand as directed and specified. (Pipes will be measured and paid separately) Essco make (a) Telephone shower delux with 1m PVC tube and wall hook
Supplying, fitting and fixing Chrome Plated (C.P.) basin mixer complete as directed. Jaquar make (For VIP use. Prior approval of Chief Engineer PWD (Bldg) must be taken before use) a) Continental / Clarion i) Central hole basin mixer without popup waste system with 450mm long copper pipes and brass nuts Cat No. 167
Supplying, fitting and fixing Chrome Plated (C.P.) wall mixer complete as directed. Jaquar make a) Continental/ Clarion ii) Wall mixer non telephonic shower arrangement Cat No.219
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (i) 160mm dia.
(ii) 110mm dia.
(iv) 75mm dia.
(vi) 50mm dia
Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (i) 160mm
(ii) 110mm dia.
(iv) 75 mm dia.
b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (v) 50mm dia
Supplying fiting and fixing 87.5 degree PVC bend with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (i) 160mm dia
(ii) 110mm dia.
(iv) 75 mm dia.
Supplying fiting and fixing 45degree PVC bend of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (i) 160mm dia
(ii) 110mm dia.
(iv) 75 mm dia.
b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (v) 50mm dia
Supplying fiting and fixing PVC Plain single tee of (Supreme/ Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (i) 160mm dia
(ii) 110mm dia.
(iv) 75 mm dia.
b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (v) 50mm dia
Supplying fiting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (i) 160mm dia
(ii) 110mm dia.
(iv) 75 mm dia.
Supplying fiting and fixing PVC single ‘Y’ of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (i) 160mm dia
(ii) 110mm dia.
(iv) 75 mm dia.
Supplying fiting and fixing PVC single ‘Y’ with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (i) 110mm dia.
(ii) 75 mm dia.
Supplying fiting and fixing PVC coupler of (Supreme / Prince)or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (i) 110 mm dia
(iii) 75 mm dia
Supplying fiting and fixing PVC reducer of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (i) 160mm x 110 mm
(iv) 110 mm x 75mm
Supplying fiting and fixing PVC reducing Tee of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (i) 160mm x 110 mm
(iii) 110 mm x 75mm
Supplying fiting and fixing PVC cleaning pipe of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. in exposed surface or trences as necessary complete at all levels including below G.L. as directed and specified. (a) 160 mm
Providing fitting and fixing of Chlorinated Polyvinyl Chloride (CPVC) Pipes having thermal stability for hot and cold water supply with all necessary plain and brass threaded fittings and fixing the pipes with clamps at 1.0 m interval including jointing of pipe. (B) Concealed pipe with cutting chases & making good the walls a) 15 mm nominal outer dia pipe
b) 20 mm nominal outer dia pipe
c) 25 mm nominal outer dia pipe
d) 32 mm nominal outer dia pipe
e) 40 mm nominal outer dia pipe
f) 50 mm nominal outer dia pipe
Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed. B) PVC PIPE SUPREME / PRINCE / FUSION /SFMC Brand viii) 160mm diameter
Supplying fitting and fixing ISI approved PVC filter 3.00 metre long. v) 150mm diameter
Supplying and placing ferrocement water tanks of circular/rectengular shape over stagging with manhole cover with locking and clearing arrangement including providing pads of size as required for inlet and outlet pipes complete as directed.(Stagging should be measured and paid separately). 2000 Lt capacity water tank
1000 Lt capacity water tank
Supplying and placing ferrocement septic tanks of rectangular shape in to pit with manhole cover with cleaning arrangement over single brick flat soling and 75mm 1:3:6 P.C.C. Baffle wall, inlet and outlet etc are provided at suitable points complete as directed. 40 Users
50 Users
100 Users
For deep tube well only for Rig boring/ DTS Boring inclusive of casing pipes and all accessories of pumps etc. c) 200mm diameter
Supplying including fitting fixing of following A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department [Without regulator]. Premium model 1200 mm Sweep (ORIENT PSPO make) / Premium model 1050 / 1200 mm Sweep SS-390 Deco Havells make)
Supplying including fitting and fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt. as required complete and as directed by the Department. Domestic Heavy Duty 450 mm sweep 900 RPM Single phase (Crompton make), Heavy Duty 450 mm sweep 900 RPM Single phase (Usha make)
Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) in surface/ recessed 2 mm thick rigid low halogen SFT PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete. Short point up to 3.00 metre. length.
Medium point up to 6.00 metre. Length.
Long point up to 10.00 metre. Length.
Wiring for 5 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 2 mm thick 20 mm. dia. rigid low halogen SFT PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) Short point up to 3.00 metre. Length.
Medium point up to 6.00 metre. Length.
Long point up to 10.00 metre. Length.
Wiring for light/ fan/ call bell point with 3x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 2 mm thick 20mm dia rigid low halogen SFT PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including ceiling rose etc. complete Short point up to 3.00 metre. length.
Medium point up to 6.00 metre. Length.
Long point up to 10.00 metre. Length.
Supply with fitting and fixing of 100 W 4 step modular(2 module) fan speed controller of legrad, MK, ABB, colors, Schneider etc with necessary connection as directed by the department.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
With 3 x 4 sq mm + 2 x 2.5 sq mm earth connectivity in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
With 4 x 6 sq mm + 2 x 4 sq mm earth connectivity in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
With 4 x 10 sq mm + 2 x 6 sq mm earth connectivity in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Supply and laying of following size PVC/XLPE.insulated and PVC sheathed 11 KV gd aluminium conductor LT armoured UG. cable laid in ground/partially in air (10.0% of cable length) including excavation af cable trench upto depth of 75cm, refilling, protective brick covering, sand cushioning etc. complete handling of surplus spoil, debries etc. to proper place as specified and directed by the deptt. 25.00 sq mm 3&1/2core U.G. Cable
70.00 sq mm 3&1/2core U.G. Cable
Supply and laying heavy duty 1100V FRLS Grade PVC insulated armoured cables indoor or outdoor with AL / Cu conductors complete with a) Clamping of Cables with trays etc b) Cable Tags c) Earthing the glands armouring etc. 4C x 10 sq. mm YFY (Cu)
Supplying with fitting and fixing sheet steel, phosphatised, powder dust & vermin proof Double door (IP-43) surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Eart bar & din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection approved, specified and directed by the deptt. 4 way SPN double door
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof reversible Double door (IP-43) surface mounting horizontal TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. (Schneider neo break, C&S, Havells, INDOASIAN, Standard, HPL or equivalent Make as approved by the Deptt.) 4 way TPN (8+12) double door
6 way TPN (8+18) double door
8 way TPN (8+24) double door
12 way TPN (8+36) double door
Supplying with fitting and fixing MCCB incomer and MCB outgoing sheet steel, phosphatised, powder painted single door surface mounting vertical TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar up to 125A and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. (ABB, Schneider MG, legrand, Hager, Crabtree xpro make) 8 way TPN (4+24) single door
Supplying fitting and fixing of SPN 10 KA 240/415 V 50 Hz MCB of the following capacity complete with making necessary connection as approved specified by the department. B series Schneide, Legrand, Crabtree etc 6 AMP to 32 AMP
Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. B Series (ABB, Schneider MG, legrand, Hager, Crabtree xpro make)6 to 32A
Supplying fitting and fixing of TP 10 KA 240/415 V 50 Hz MCB of the following capacity complete with making necessary connection as approved specified by the department. B series Schneide, Legrand, Crabtree etc 40 AMP
Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz DP RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 100/300mA sensitivity DP RCCB (ABB, Schneider MG, legrand, Hager, Crabtree xpro make) 25A
Supplying with fiting and fixing of panel mounting open execution 25KA 415V 50 Hz 4P MCCB(Ics=Icu adjustable Ir setting 0.7 withoput enclosure) of the following capacity with necessary connection as approved , specified and directed by the department 25 KA 415V 50 Hz 4P MCCB 63 AMP
Supplying with fitting and fixing panel mounting open execution 35/36KA 415V 50Hz 4P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 35/36 KA 415V 50 Hz 4P MCCB (Schneider, legrand, Siemens make) 160A
Supply, installation & testing of Copper Plate earth station with 600 mmx600 mmx6 mm heavy duty copper earth plate with necessary 40 mm dia. G.I. medium duty watering pipe with G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement with 300 mmx300 mmx6 mm C.I. hinged cover plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .
Extra for using salt 5 Kg and Charcoal 96 Kg in G.I./Copper plate Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the deptt .
Supplying & laying of 32x6 mm size G.I. strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply of G.I. nuts & bolts, screws etc including riveting, soldering & making necessary connection as approved, specified and directed by the deptt.
Supplying & laying of 25x4 mm size Copper strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply of Brass nuts & bolts, screws etc including riveting, soldering & making necessary connection as approved, specified and directed by the deptt.
Supplying & laying of 6 SWG G.I. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
Supplying including and fixing of metal boxes in recessed system complete as per direction of department. Legrand/anchor/schneider or equivalent 1-2 module type metal
3 module flush type metal
4 module flush type metal
6 module flush type metal
8 module flush type metal
10 module flush type metal
12 module flush type metal
16 module flush type metal
Supplying including fitting fixing of logic front plate of suitable colour as per direction of department. Legrand/anchor/schneider or equivalent 1 module type metal
2 module type metal
3 module flush type metal
4 module flush type metal
6 module flush type metal
8 module flush type metal
10 module flush type metal
12 module flush type metal
16 module flush type metal
Supplying with fitting fixing 6 amp one way modular clip in switch in recessed system including making necessary connection complete as per direction of department. Legrand/anchor/schneider or equivalent
Supplying including installation of socket outlet 6/16 Amps 3/5 pin combine shuttered complete as per direction of department. Legrand/anchor/schneider or equivalent
Supplying including installation of socket outlet 6 Amps 3 pin combine shuttered complete as per direction of department. Legrand/anchor/schneider or equivalent
Supplying with fitting fixing 10/16 amp one way modular clip in switch in LED in recessed system including making necessary connection complete as per direction of department. Legrand/anchor/schneider or equivalent
Supplying including fitting and fixing of rigid PVC. Conduit pipes including painting etc. complete in surface wiring system. 25 mm. Dia, 1.5 - 2.0 mm mm thick, rigid PVC. Conduit pipes
Supplying with fitting fixing blank plate single in modular switch recessed system with including making necessary connection complete as per direction of department. Legrand/anchor/schneider or equivalent
Three phase Submersible motor pump set (Texmo / Crompton Greaves/ Aquatic/ CRI/ V-Guar suitable for 100 mm bore well and above. 2 HP STAGE 6 to 30 with MCB controlled Submersible motor pump set control panel.
Supplying fitting and fixing including necessary connection as approved by the Deptt.)of Submersible motor pump set control panel including Starter ( Crompton Greaves/ Control & Switch Gear/ BCH/ L& T / Siemens make) of following capacity as specified and directed by the Department. (Texmo/ Crompton Greaves/ CRI/ Aqua sub make) Submersible motor pump set control panel including Starter ( Crompton Greaves/ Control & Switch Gear/ BCH/ L& T / Siemens make)2 HP
Supplying and fixing of Jaquar make 40W LED TUBE LIGHT CAT no LUNIOX220 XC fittings complete with Shade, back plate including connection cable, as approved by the Deptt.s etc. as required.
Supplying and fixing of Jaquar(CAT NO LGLZPCX022XC) or equivalent LED strip batten light fittings complete with Shade, back plate including connection cable, as approved by the Deptt.s etc. as required. LED Strip Batten,22W
Supplying and fixing of Jaquar or equivalent surface mounted 36W 2' x 2' 125Lm/W LED panel 6500K downlighter withwhite powder coated CRCA housing with full mounted acrylic diffuser fittings complete with Shade, back plate including connection cable, as approved by the Deptt.s etc. as required.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .