| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.6 LAccepted-AOC | ₹27.6 L Quoted ₹28.7 L | L1 | Accepted-AOC Accepting being lowest |
| 2 | L2₹30.3 L+₹1.7 L (5.86%)Rejected-Finance PLOT NO 8 PREMA APARTMENT VEDANTNAGAR CHHATRAPATI SAMBHAJINAGAR 431 007 M S | CHHATRAPATI SAMBHAJINAGAR | CHHATRAPATI SAMBHAJINAGAR | MAHARASHTRA | 431007 | ₹30.3 L+₹1.7 L (5.86%) | L2 | Rejected-Finance Rejected being other than lowest |
| 3 | L3₹35.7 L+₹7.0 L (24.4%)Rejected-Finance 02 NERLE NERLE YEWALEWADI ROAD NERLE SANGLI MAHARASHTRA 415406 | SANGLI | MAHARASHTRA | 415406 | ₹35.7 L+₹7.0 L (24.4%) | L3 | Rejected-Finance Rejected being other than lowest |
| 4 | L4₹36.0 L+₹7.4 L (25.7%)Rejected-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | ₹36.0 L+₹7.4 L (25.7%) | L4 | Rejected-Finance Rejected being other than lowest |
| 5 | L5₹37.9 L+₹9.2 L (32.2%)Rejected-Finance | ₹37.9 L+₹9.2 L (32.2%) | L5 | Rejected-Finance Rejected being other than lowest |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
28 Jan 2023, 6:00 pmClosed
Shri Prakash G Kalekar AE QS and C
Military Engineer Services, Garrison Engineer (South) Ahmednagar - 414002
REPAIRS TO CEILING FANS, EXHAUST FANS, TABLE FANS, GEYSERS AND DOOR TO DOOR MAINT OF INTERNAL ELECTRIC WIRING ETC AT AGE AURANGABAD UNDER GE (S) AHMEDNAGAR
2022_MES_572115_1
8934/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
Aurangabad
Class D Cat b (i)
8 documents required · 8 mandatory
₹500
Garrison Engineer (South) Ahmednagar
₹1 L
Yes
2 Feb 2023
30 Dec 2022
30 Jan 2023
30 Dec 2022
28 Jan 2023
13 Jan 2023
30 Dec 2022 - 6 Jan 2023
Amount
Taking down from site or collecting from E/M yard, unserviceable (burnt) ceiling fan, 1200 mm sweep, any make, with blades, transporting to local workshop, opening, cutting and taking out complete copper winding, cleaning with kerosene oil /diesel/ terpentine oil and dried out, rewinding with new super enamelled copper wire of suitable size and gauge and number of turns as recommended by the respective manufactures, varnishing and heating the winding including providing paper insulation (cuff/strip type) replacing unserviceable providing paper insulation (cuff / strip type) replacing unserviceable / missing spare (bush, bearing, capacity shackle insulator, canopy, nuts, bolts, earthing, screw, upper, socket, CI block , quarter /split pin (top & bottom) , lock nut etc) fixing the stator in rotor properly aligned and resembling ensuring right DOR, speedy and noiseless running and depositing in E/M yard and hanging at site in position complete all as directed. Note : Bush, bearing, capacitor, and canopy, shackle insulator with nuts, bolts and sockets shall be measured and paid separately as supply only and the cost of fixing shall deemed to be included in the unit rate quoted.
All as per serial item No 1, but ceiling fan 1400 mm sweep.
All as per serial item No 1, but exhaust fan 300/380 mm sweep.
All as per serial item No 1, but exhaust fan 450 mm sweep.
All as per serial Item No 1, but wall mounted fan/table fan/cabin fan /Padestal fan of any sweep.
all as per serial item No 1, but air circulating wall mounted fan, 450 mm to 600 mm sweep
Taking down from site or collecting unserviceable ceiling fan of any sweep and make from E/M yard, transporting to local workshop, cleaning external portion with washing soda for removing oily stain, opening and cleaning internal portion with kerosene oil, drying it out, oiling / greasing properly, replacing unserviceable bearing / bush / rubber bush for arm with nuts & clamp / flexible wire and reassembling ensuring speedy and noiseless run and hanging the same at site complete all as directed. Note :- (i) Spares shall be measured and paid for separately as supply only and the cost of fixing shall deemed to be included in the unit rate quoted. (ii) Repairs to winding is not included in this item.
Taking down from site or collecting unserviceable exhaust fan of any sweep and make from E/M yard, transporting to local wksp, cleaning external portion with washing soda for removing oily stain, opening and cleaning internal portion with kerosene oil, drying it out, oiling / greasing properly, replacing unserviceable bearing / bush / rubber bush for arm with nuts & clamp / flexible wire and reassembling ensuring speedy and noiseless run and hanging the same at site complete all as directed. Note :- (i) Spares if required shall be measured and paid separately under respective items as supply only, however fixing in repairs/replacement is deemed to be included in this item. (ii) Repairs to winding is not included in this item.
Supply only bush, suitable for ceiling fan /exhaust fan of any sweep complete all as specified and as directed.
Supply only ball bearing (No 6201,6202,6203 or 6204) suitable for 1200 / 1400 mm sweep ceiling fan complete all as specified and as directed
Supply only ball bearing (No 6201,6202,6203 or 6204) suitable for 300 / 400/ 450 mm sweep exhaust fan complete all as specified and as directed.
Supply only ball bearing (No 6201,6202,6203 or 6204) suitable for 400 / 450 / 600 mm sweep wall mounted/cabin/table fan complete all as specified and as directed.
Supply only capacitor 2.50 mfd to 3.15 mfd complete all as specified and as directed.
Supply only capacitor 4 mfd, for exhaust fan/wall mounted fans etc of 300mm / 450mm / 600 mm sweep complete all as specified and as directed.
Supply only canopy for ceiling fan (top and bottom), any size & make complete all as specified and as directed.
Supply only MS fan rod and clamps with rubber seal including nuts and bolts, split pin, suitable for ceiling fan 1200 / 1400 mm sweep complete all as specified and as directed.
Supply only ceiling fan blade, set of 3 piece of aluminium sheet suitable for 1200 mm sweep, matching with the existing colour brown / white etc. complete all as specified and as directed.
Supply only ceiling fan blade set of 3 piece mild steel sheet, suitable for 1400 mm sweep matching with the existing colour brown / white etc. complete all as specified and as directed.
M&L for preparation of surfaces and spray painting to ceiling fans (in situ) of any type , size and make, with super enamelled heat resistant synthetic white paint duly filling the cavities with filler and re-writing the MES number in black paint in appropriate size and shape all as specified and as directed.
M&L for preparation of surfaces and spray painting to exhaust fans (in situ) of any type, size and make, with super enamelled heat resistant synthetic white paint duly filling the cavities with filler and re-writing the MES number in black paint in appropriate size and shape all as specified and as directed.
M&L for preparation of surfaces and spray painting to wall mounted fans/air circulating fans, pedestal fans etc (in situ) of any type , size and make of with super enamelled heat resistant synthetic white paint duly filling the cavities with filler and re-writing the MES number in black paint in appropriate size and shape all as specified and as directed.
Taking down electric water heater (geyser) of any type/capactiy for repairs, dismantling the accessories carefully after disconnecting the water/electirc connection and transporting to workshop(if required) for repairs and refixing the same in original position after repairs and connecting up the water/electric connections including testing complete all as specified and as directed. Note : Replacement of unserviceable parts shall be measured and paid seperately.
S&F in repairs, heating element, triangular or square type, 1500watts, 230 volts, suitable for geyser and as per approved sample all as specified and as directed.
S&F in repairs, heating element, triangular or square type, 2000watts, 230 volts, suitable for geyser and as per approved sample all as specified and as directed.
S&F in repairs, heating element triangular/ square headed with inbuilt thermocut switch/ thermostat of 1.5/2.0 KW, suitable for 25/50 litre capacity geyser existing at site all as specified and as directed.
S&F in repairs, thermostat, auto cut with thermal setting upto 80 degree centigrade, 230 Volts, suitable for existing geysor(25/35/50 lit) of various capacities all as specified and as directed.
S&F in repairs, inner copper, water storage tank of 25 ltr capacity geyser existing at site all as specified and as directed.
S&F in repairs, inner copper, water storage tank of 50 ltr capacity geyser existing at site all as specified and as directed.
S&F in repairs, syphon assembly suitable for 25 ltr capacity geyser existing at site all as specified and as directed.
S&F in repairs, syphon assembly suitable for 50 ltr capacity geyser existing at site all as specified and as directed.
S&F in repairs, aperture plate assembly complete suitable for 25 Ltrs capacity geyers existing at site all as specified and as directed.
S&F in repairs, aperture plate assembly complete suitable for 50 Ltrs capacity geyers existing at site all as specified and as directed.
S&F in repairs, 15mm bore dia, non return valve, cast copper alloy suitable for geyser all as specified and as directed.
S&F in repairs, 15mm bore dia, pressure release valve, cast copper alloy suitable for geyser all as specified and as directed.
S&F in repairs glass wool in geyser of 25/50 litre capacity all as specified and as directed.
S&F in repairs indicator, lamp red/green for geyser all as specified and as directed.
S&F in repairs drain plug for 25/50 litre capacity geyser all as specified and as directed
S&F in repairs, 15mm bore dia, stop valve, fancy type, cast copper alloy, chromium plated, screwed for iron pipe and fixed all as specified and as directed
M& L for mild steel hold fast/fasteners fixing to wall, suitable for hanging of geyser of any capacity including making good surface with cement mortar 1:4 complete all as specified and as directed.
S&F in repairs, heat resistant, PVC, flexible connection pipe, 450 mm long, suitable for 15 mm dia pipe with brass creamed nipple and nuts, heavy duty pressure grade 6 Kg/cm2 all as specified and as directed by Engr in Charge.
S&F in repairs,15 mm bore galvanised iron pipe, medium grade with all fittings and fixed complete to walls and ceilings or laid in floor complete all as specified and as directed.
S&F in repairs, 3-layer PP-R (Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings ( Including all type of fittings like bends, sockets ,Tees, etc) of fixed complete to walls, ceilings or in floors etc. complete all as specified and as directed.
Taking out old thermostat/heating element and refixing the same after descaling/ cleaning and making electrical connection and calibrating/adjusting to a temperature rating as per manufacturer recommendation all as specified and as directed
Taking down carefully copper/aluminum point wiring (Light, Fan, Socket or power) complete fitting such as switches, ceiling, regulator, sockets etc and making good disturbed surfaces of walls, floors etc and matching with existing surface complete all as specified and as directed.
M&L for point wiring (Light Point) complete with 1.5 Sqmm single core multistranded copper conductor FRLS, PVC insluated and unsheathed cable 650/1100 volts grade, confirming to IS-694 1990, drawn through and including PVC casing capping 32mm /25 mm width with all accessories as specified with modular cover plate with frame and modular metal flux boxes, blank plate for mounting fitting & fixture like switches sockets and fan regulators etc including copper earth contunity wire for PVC insulated of size 1.5 Sqmm for one light point controlled by one way switch complete all as specified and as directed.
All as per serial item No. 45 but for one fan point controlled by one way switch and regulator complete all as specified and as directed.
All as per serial item No. 45 but for one 3 pin socket outlet,5 Amps on same board with other switches one 3 pin socket outlet 5 Amps on same board with other switches complete all as specified and as directed.
All as per serial item No 45 but for one 3 pin socket outlet , 5 Amps on independent board but below the switch board of light points in the same vertical plane , with cables 1.5 Sqmm complete all as specified and as directed.
All as per serial Item No-45 but for one light point controlled by two,two way switch compete all as specified and as directed.
All as per serial item No 45 but for one bell point controlled by one bell push complete all as specified and as directed.
All as per serial item No. 45 but for one 3 pin socket outlet, 5 Amps on independent board complete all as specified and as directed.
All as per serial item No.45 but with 4.0 Sqmm copper conductor cable for socket outlet 15 Amps complete all as specified and as directed.
All as per serial item No 45 above but for power point 3 pin switch socket 15 Amp with PVC copper conductor cable multistrand unsheathed 2.5 Sqmm on independent board incl one run 1.5 Sqmm multistrand PVC copper conductor cable for earth continuity in and including PVC casing and capping fixed on wall incl including PVC box 2 mm complete all as specified and as as directed .
S&F in repairs, modular switch single pole one way 6/5 Amps 1 module complete all as specified and as directed.
S&F in repairs, modular switch single pole one way 16 Amps 1 module complete all as specified and as directed.
M&L for modular bell switch 5/6 Amp 1 Module complete all as specified and as directed.
S&F modular Switch 2 way 1 module complete all as specified and as directed.
M&L in repairs, modular socket 6 Amp-2/3 pin combined 2 module complete all as specified and as directed.
M&L for modular socket 6 A/16 Amp -2/3 pin combined 2 module complete all as specified and as directed.
S&F modular fan regulator step type ,120W -2 Module Complete all as Specified and as directed.
S&F ceiling rose surface bakelite three terminal type complete all as specified and as directed
S&F in repairs, decorative ultra slim square profile LED lighting fixyure with extruded polycarbonate, environmental friendly , energy efficient of capacity 18/20 Watt , appx 4 feet long,6500 K with inbuilt driver complete fitting and all other accessories fitting arrangements including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed
S&F in repairs, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient of capacity 10 Watt , 2 feet long, 3000 K with inbuilt driver complete fitting and all other accessories fitting arrangements including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
S&Fin repairs, LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed.
S&Fin repairs, lamp LED 9/10 Watt, 230 volts 50 Hz AC complete all as specified and as directed
S&F in repairs, lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
S&F in repairs, LED light fitting 1x 9W / 1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed
S&F in repairs, MCB DB double door 4 way TPN with suitable rated busbar 240 V complete all as specified and as directed.
S&F in repairs, MCB DB double door 16 way SPN with suitable rated busbar 240 V complete all as specified and as directed
S&F in repairs, MCB DB double door 12 way SPN with suitable rated busbar 240 V complete all as specified and as directed.
S&Fin repairs, MCB DB double door 8 way SPN with suitable rated busbar 240 V complete all as specified and as directed
S&F in repairs, MCB DB double door 4 way SPN with suitable rated busbar 240 V complete all as specified and as directed
S&F in repairs, MCB DB single door 2 way SPN with suitable rated busbar 240 V complete all as specified and as directed.
S&F in repairs, single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amp 240 Volts complete all as specified and as directed.
S&F in repairs, MCB SP, C Curve, 6 to 32 Amps 10 KA single pole AC 230 volts complete all as specified and as directed
S&F in repairs, MCB SPN, C Curve, 40-63 Amps 10 KA single pole AC 230 volts complete all as specified and as directed
S&F in repairs, MCB C Curve TPN 40-100 Amps, 415 V complete all as specified and as directed
S&F in repairs, MCB C Curve TPN 16-32 Amps, 415 V complete all as specified and as directed
S&F in repairs, of bell multi music type, AC, 230 volts, single phase complete all as specified and as directed
M&L for sub main wiring with 2 runs of 6.0 sqmm, single core, PVC insulated & unsheathed cable, conforming to IS-694, 1100 volts with copper conductor, multi stranded, drawn in and including suitable size PVC Cassing Capping (ISI marked) with all accessories such as Tees, Elbows, junction box etc as requied alongwith one run of 6.0 sqmm single core PVC insulated & unsheathed copper conductor as continuous earth wire dolly and connecting to existing main switch board / distribution board of each building as ordered and testing on completion including taking down old submain wiring and any type of casing/caping/Conduit, complete all as specified and as directed. Note : Two runs of 6.0 Sqmm cable, one run of 6.0 Sqmm cable and one run of PVC casing/caping will be measured as one RM unit.
M&L for sub main wiring with 2 runs of 4.0 sqmm, single core, PVC insulated & unsheathed cable, conforming to IS-694, 1100 volts with copper conductor, multi stranded, drawn in and including suitable size PVC Cassing Capping (ISI marked) with all accessories such as Tees, Elbows, junction box etc as requied alongwith one run of 4.0 sqmm single core PVC insulated & unsheathed copper conductor as continuous earth wire dolly and connecting to existing main switch board / distribution board of each building as ordered and testing on completion including taking down old submain wiring and any type of casing/caping/Conduit, complete all as specified and as directed. Note : Two runs of 4.0 Sqmm cable, one run of 4.0 Sqmm cable and one run of PVC casing/caping shall be measured as one RM unit.
M&L for sub main wiring with 2 runs of 2.5 sqmm, single core, PVC insulated & unsheathed cable, conforming to IS-694, 1100 volts with copper conductor, multi stranded, drawn in and including suitable size PVC Cassing Capping (ISI marked) with all accessories such as Tees, Elbows, junction box etc as requied alongwith one run of 2.5 sqmm single core PVC insulated & unsheathed copper conductor as continuous earth wire dolly and connecting to existing main switch board / distribution board of each building as ordered and testing on completion including taking down old submain wiring and any type of casing/caping/Conduit, complete all as specified and as directed. Note : Two runs of 2.5 Sqmm cable, one run of 2.5 Sqmm cable and one run of PVC casing/caping shall be measured as one RM unit.
S&Fin repairs, post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete including suitable size of GI Pipe as per lamp size including connection and testing complete all as specified and as directed
S&F in repairs, 35/40 Watt building mounted LED Security light fitting complete made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection and impact resistance of IK07 & 10KV external SPD, including GI bracket made out of GI pipe 40/50 mm bore, medium grade pipe 1.2 m long bend to shape required fixed to pole / wall with 02 Nos MS clamps made out of flat iron 40 x 5 mm including nuts, bolts and washer, painting with two coats aluminium paint over a coat of primer, suitable for LED fitting, complete all as specified and as directed.
M&L in repairs/replacement earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level, connecting to the GI wire 4 mm dia , by means of nut bolts, check nuts and washer of the GI . Earth wire connected upto main earth point/DBs alongwith 15mm dia GI pipe, medium grade, including provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregates with 40 mm thick RCC (1:2:4) cover with reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25mm X 25 mm X 3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified including testing on completion.
S&F in repairs, 1100 Volt grade heavy duty cable PVC insulated aluminium Stranded conductor served with inner sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulating hangers not more than 1 m apart including 4 mm suspension wire one twin core cable flat of stranded multistrand conductor size 4.0 sqmm complete all as specified and as directed.
S&F in repairs, 1100 Volt gde heavy duty cable PVC insulated aluminium Stranded conductor served with inner sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulating hangers not more than 1 mtr apart including 4 mm suspension wire one twin core cable flat of stranded multistrand conductor size 6.0 sqmm complete all as specified and as directed.
Repair / maintenance of internal wiring for fans, light fittings of any type like tube lights / wall brackets / light fittings / ceiling lights / mirror lights / table lamp lights in its position, testing all the components / parts, wiring etc identifying and replacing the defective components like choke (ballast), tube rod, side holders, lamp holders with capacitors etc all as specified and directed by Engg-in-Charge. Notes : (i) The rate against the above mentioned item includes cost of taking down & fixing of spares/fixtures/fittings required for repair work. (ii) Cost of spares like choke (ballast), capacitor, lamp holder, LED Bulb, connector, connection wire etc. replaced against above mentioned items shall be measured & paid for separately under respective items of Sch 'A' as "Supply only". However cost of minor items such as screws, rawl plugs, insulation tape etc is included in this item. (iii) The contractor's representative shall report to concerned JE E/M at 09:00 hrs daily to collect the list of defects and shall submit the completion report on the same day before 17:00 hrs to the JE E/M. (iv) The contractor has to rectify the defects and make the light fitting functional within 24 hours from the time the list of defective lights is handed over to him / his representitive by the concerned JE E/M. In case the light fitting is not made functional for whatsoever reason within the specified time limit a recovery of Rs. 100/- per defective light fitting per day will be recovered from the amount due to him through RAR / Final Bill. The repair / maint in single accommodation where required shall be carried out as per the timings convenient to cadets or as directed by Engineer-in-Charge and preferably during afternoon and study period. The contractor shall engage two saparate teams of technicians / repairer for entire area. (v) The contractor shall maintain proper record of repair/maint in a binded register duly bringing out the details of spares replaced on each and every light fitting and get it authenticated from concerned JE E/M on daily basis. The contractor shall put up the maint record register to Engineer-in-Charge for inspection every Monday or as and when asked for. (vi) The contractor shall maintain sufficient stock of spares material required for repair / maint of light fittings with the concerned JE E/M against the supply only items here-in-below. (vii) The Electricians should be ITI (Electrical) qualified with one year experience or matric passed with minimum three years experience as electrician and for the contractor should submit the copy of certificates of electricians while signing the site orders.
Supply only switch piano, flush button, 5 Amp, single pole, one way, 230 volts, white finish, for repair work complete all as specified & as directed.
Supply only socket outlet, flush type, 5 pin, 5 Amp, multipurpose, 230 volts, single pole one way suitable for 3 pin/2pin 5 Amp plug top white/ivory finish complete all as specified and as directed.
Supply only switch piano, flush button, 16 Amp, single pole, one way, 230 volts white finish complete all as specified & as directed.
Supply only socket outlet, flush type, 6 pin, 16 Amp, multipurpose, 230 volts, single pole, one way, suitable for 3 pin, 16 Amp plug top, white/ivory finish complete all as specified and as directed.
Supply only switch socket combination multipurpose, flush type 2 in 1 type, 6 pin, 6/16 Amps, 230 Volts, AC white/ivory finish complete all as specified and as directed.
Supply only switch socket combination flush type 5 pin 6 Amp multipurpose, 230 volts, single pole one way suitable for 3 pin/2pin 5 Amp plug top white/ivory finish complete all as specified and as directed.
Supply only lamp holder,Angle/BattenType PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
Supply only fan regulator electronic on existing phenolic laminated sheet, 5 Step, Socket Type,230 volts, 450 watts suitable for ceiling fan 1200/1400mm sweep complete all as specified and as directed.
S & F electronic dimmers, 450W, 250V flush type on the exiting phenolic laminated sheet etc. as reqd complete all as specified and directed.
Supply only fan capacitor 2.50 mfd to 4.0 mfd , 440 Volt AC, 50 Hz PCB Oil filled type complete all as specified and as directed.
Supply only MS fan clamps with rubber real and hook including nuts and bolts, split pin suitable for ceiling fan 1200 / 1400 mm sweep complete all as specified and as directed.
Supply only bell push, flush type, 5 Amp single pole, 230 volts white finish complete all as specified and as directed.
Supply only bell multi music type, AC, 230 volts, single phase complete all as specified and as directed.
Supply only buzzer Ding Dong, AC, 230 volts, single phase complete all as specified and as directed.
Supply only decorative ultra slim square profile LED lighting fixyure with extruded polycarbonate,environmental friendly , energy efficient of capacity 10 Watt , appx 2 feet long,3000 K with inbuilt driver complete fitting and all other accessories fitting arrangements complete all as specified and as directed.
Supply only LED Blub 9W, B-22 Base, 6000K, 100 lumen per watt , suitable for 230V AC supply complete all as specified and as directed.
Supply only decorative ultra slim suuare profile LED lighting fixyure with extruded polycarbonate,environmental friendly , energy efficient of capacity 18 Watt , appx 4 feet long,6500 K with inbuilt driver complete fitting and all other accessories fitting arrangements complete all as specified and as directed.
Supply only modular switch single pole one way 6/5 Amps 1 module complete all as specified and directed
Supply only modular switch single pole one way 16 Amps 1 module complete all as specified and directed
Supply only modular socket 6 Amp-2/3 pin combined 2 module complete all as specified and directed
Supply only modular socket 6 A/16 Amp -2/3 pin combined 2 module complete all as specified and directed
Supply only white cover plate with frame, 3 module complete all as specified and directed.
Supply only white cover plate with frame,4 module complete all as specified and directed.
Supply only white cover plate with frame, 6 module complete all as specified and directed.
Supply only white cover plate with frame, 8 module complete all as specified and directed.
Supply only MCB SP, C Curve, 6 to 32 Amps 10 KA single pole AC 230 volts complete all as specified and as directed.
Supply only MCB SPN, C Curve, 40-63 Amps 10 KA single pole AC 230 volts complete all as specified and as directed.
Supply only MCB C Curve TPN 40-100 Amps, 415 V complete all as specified and as directed.
Supply only MCB C Curve TPN 16-32 Amps, 415 V complete all as specified and as directed.
Supply only MCB C Curve TP 25-63 Amps, 415 V complete all as specified & as directed.
Supply only ceiling rose surface bakelite three terminal type complete all as specified and directed .
Supply only PVC casing caping 32 mm with fixing accessories such as complete,lock nuts, saddles hook etc of adequate size complete all as specified & as directed.
Supply only thermostat auto cut with thermal setting upto 80 degree centigrade, 230 V, for the geysers 25/35 Ltrs capacity as per site requirement complete all as specified and as directed.
Supply only heating element triangular or square headed with in built thermocut switch/ thermostat type of rating 1.5/ 2 KW, 230 volts ISI marked complete all as specified and as directed.
Supply only PVC board of size 4" X 4" including cutting for fixing of switches and socket complete all as specified and as directed.
Supply only PVC board of size 6" X 8" including cutting for fixing of switches and socket complete all as specified and as directed.
Supply only PVC board of size 4" X 7" including cutting for fixing of switches and socket complete all as specified and as directed.
Supply only self adhesive PVC electrical insulation tape of size 1.80 cm (width) x 6.0 M (length) x 0.125 mm (thickness) of red/yellow/green & black colour complete all as specified and directed.
Supply only PVC insluated and unsheathed cable 650/1100 volts grade, single core multistranded copper conductor fire retardant cable of size 1.5 sqmm complete all as specified & as directed.
Supply only PVC insluated and unsheathed cable 650/1100 volts grade, single core multistranded copper conductor fire retardant cable of size 2.5 sqmm complete all as specified and as directed.
S&F in repairs, round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed
ASHWAMEDH ENGINEERS
RELIABLE ENTERPRISES
metro electrical services
M/s. Gurudatt Electricals And Engineers, Aurangabad
Shri Sai Enterprises
SONU ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .