Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.3 LAccepted-AOC ANAND NAGAR ROAD NO 4 RAJAKHEDI MAKRONIA SAUGOR MP | SAUGOR | SAUGOR | MP | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹22.1 L+₹4.8 L (27.6%)Rejected-Finance | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹22.4 L+₹5.0 L (28.9%)Rejected-Finance | L3 | Rejected-Finance Not lowest bidder | |
| 4 | Rejected-Technical NEAR GURUDWARA JHANSI BHOPAL ROAD SAUGOR M P 470002 | SAUGOR | SAGAR | MADHYA PRADESH | 470002 | - | Rejected-Technical Adverse remarks in WLR of HQ CEBZ Bhopal for QE Sep 2024 |
Tender Value
₹24.3 L
EMD Value
₹48,500
Closing Date
28 Dec 2024, 6:00 pmClosed
GARRISON ENGINEER SAUGOR
Military Engineer services Garrison Engineer Saugor MP- 470001
REPAIR/REPLACEMENT OF SEWAGE LINE CLEANING OF SEPTIC TANKS MANHOLES CLEANING OF SEWAGE LINE AND SPOT BLOCKAGE UNDER AGE B/R-II AT GE SAUGOR
2024_MES_686611_1
GE/SGR/TOK-46 OF 2024-25
Open Tender
Civil Works
Item Rate
270 days
Saugor
Class E category a (ii) and as per tender documents
6 documents required · 6 mandatory
₹500
GARRISON ENGINEER SAGAR
₹48,500
Yes
4 Feb 2025
2 Dec 2024
30 Dec 2024
2 Dec 2024
28 Dec 2024
16 Dec 2024
2 Dec 2024 - 9 Dec 2024
Amount
S&F 110 mm dia PVC(SWR) pipes single soketed in any length with adhesive jointed fixed to wall with mild steel clamps of suitable size, including taking up and down old unservicable SWR pipe of any dia inlcuding fittings complete all as specified and directed.
S&F 110 mm dia PVC(SWR) pipes single soketed in any length with adhesive jointed laid in trenchs or in floor, including taking up and down old unservicable SWR pipe of any dia inlcuding fittings complete all as specified and directed.
S&F 75 mm dia PVC(SWR) pipes single soketed in any length with adhesive jointed fixed to wall with mild steel clamps of suitable size, including taking up and down old unservicable SWR pipe of any dia inlcuding fittings complete all as specified and directed.
S&F 75 mm dia PVC(SWR) pipes single soketed in any length with adhesive jointed laid in trenchs or in floor, including taking up and down old unservicable SWR pipe of any dia inlcuding fittings complete all as specified and directed.
S&F PVC (SWR) bends 110 mm dia complete all as specified and directed.
S&F PVC (SWR) bends 75 mm dia complete all as specified and directed.
S&F PVC (SWR) junction single ( single T ) equal or unequal 110mm dia complete all as specified and directed.
S&F PVC (SWR) junction single ( single T ) equal or unequal 75mm dia complete all as specified and directed.
S&F 75 mm dia PVC ( SWR) floor trap with grating including jointing with solvant etc. complete all as specified and directed.
S&F PVC (SWR) vent cowl 110mm dia complete all as specified and directed.
M&L for cleaning of septic tank / soak well of any capacity by mechanicaly means including vaccume sunction taking of suitable capacity fitted with vaccume sunction pump of capacity not less then 15 cum/hr and deposited at trenching ground complete all as specified and directed.
M&L for cleaning of sewage line, SWG/CI pipe or RCC pipe vertically/horizontally of dia n.exc 200 mm by rodding well flushing by using sufficient water and making it to clear for easy flow of sewage from WC, gully trap, Nahani trap upto the first manhole including desludging of first manhole and make it the proper functional to entire satisfaction of Engineer-in-Charge and removing the sludge, silt etc to a distance n.exc 500m and burying it in pits and covered with earth complete all as specified and directed.
All as per item No. 12.00 here -in-before but length of sewage line cleaned manhole to manhole complete by rodding and well flushing with sufficient water, length of sewage line upto 10 M including desludging of both sides existing manholes complete to entire satisfaction of department complete all as specified and directed.
All as per item No 12.00 here -in-before but length of sewage line cleaned exc 10 M but n.exc 25 M from manhole to manhole including desludging of both sides existing manholes complete to entire satisfaction of Engineer-in-Charge complete all as specified and directed.
M&L for dewatering from soak well of any dia and depth completely by pumping out and remove in to nearby nala/drains complete all as specified and directed.
M&L for cleaning of man holes of any size and depth by anty means and getting out sludge and removing to a distance upto 100 mtr and burried into pits covered with 10cm thick soil complete all as per specification and directed.
M &L for Brickwork with subclass 'B' bricks, straright or curved on plan exc 6m mean radius built in Cement mortar 1:6, including Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M&L use and waste formwork to soffits of suspended slabs such as roof slabs , floor slabs , landings and similar works , not exceeding 200 mm thick ( horizontal or sloping ) including slab edges for rough finished surfaces of concrete complete all as specified and directed
M&L reinforced cement concrete design mix M-25 using 20 mm graded aggregate slab support on walls, beams and columns in floors , roofs , landing balconies deck slab etc, including demolition of existing broken slabs complete all as specified and directed.
M&L for precast reinforced cement concrete 1:1.5:3 type A-1 using 20mm graded stone aggregate as in cover slab of manhole set in cement mortar 1:4, including demolition of existing broken cover slabs complete all as specified and directed.
M&L for mild steel TMT bars ,10mm dia and over, cut to length bent to shape required including cranking bending spirally for hoping for coloumns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed.
M&L for cement concrete 1:4:8 Type D-2 (using 40 mm graded stone aggregates) as in foundations, filling and mass concrete, including demolition of old cement concrete of any description and in any position not other wise specified complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in benching,floors and the like including weathering, slightly rounded or chamfered angles and throating including form work complete all as specified and directed.
M&L for PCC 1:2:4 type B0 (using 12.5 mm gradedstone aggregates) as in coping and the like including weathering, slightly rounded or chamfered angles and throating including form work complete all as specified and directed.
M&L for rendering 15mm thick cement plaster in cement mortar 1:4 on brick work / Concrete surfaces finishing the surfaces even and smooth with out using extra cement etc. complete all as per specified and directed.
Supply and fixing in repair vitreous China urinal bowl, flat back of size 465mm x 355mm x 265mm (minimum) white with grating and union for discharge pipe , waste pipe (excluding flushing cistern,flush pipe) complete all as per specified and directed.
Supply and fixing in repair vitreous Chinaware EWC padestal type closet with and including white seat & cover with flat bottom with hinging device etc. complete all as per specified and directed.
S&F in repair vitreous China squatting pan 'Orrisa pattern' size 580mm x 440mm white with integral foot rests any pattern including provn of cement concrete bedding and making connection with & including P or S Trap, etc complete all as specified and directed.
S&F in repair PVC low level flushing cistern of 10 Ltr capacity including flushing pipe, bend, PVC bend etc. complete all as specified and directed.
M&L for coloured anti skid ceremic tiles 7 to 8 mm thick area of each tiles exc. 0.11 sqm and n. exc. 0.18 sqm (400 x 400 mm joint free (rectified) ) as in floor set & jointed in neat cement slurry and pointed in white /coloured cement to match the colour of tiles laid over and including 15 mm thick screed bed in CM 1:6, including dismantling of old floor, hearth or wall tiles / terrazo including cement mortar bedding (but not backing) and rubbish off the premises complete all as per specified and directed.
Excavating in trenches n exc 1.5 m wide n exc 1.5 m deep in any type of soil for foundation etc or for shaft, wells, manholes etc n exc 10 Sqm on plan and not exc 1.5 m in depth and getting out. complete all as specified and directed.
Removing excavated soil not exceeding 50 m distance and depositing where directed at a level n exc 1.5 metre above the starting point complete all as specified and directed.
Returning ,filling in including spreading ,levelling watering and well ramming with soil in layers n exc 25 cm thick complete all as specified and directed.
Demolition and breaking up drain pipes (salt glazed ware)/ RCC pipe etc set in cement mortar, 100 mm dia pipe complete all as per specified and directed.
Demolition and breaking up drain pipes (salt glazed ware)/ RCC pipe etc set in cement mortar, 150 mm dia pipe complete all as per specification and directed.
Demolition and breaking up drain pipes (salt glazed ware)/ RCC pipe etc set in cement mortar, 200 mm dia pipe complete all as per specification and directed.
S&F HDPE double wall corrugated sewage pipe of 100 mm internal bore, SN-8, ISI marked as per IS 16908 Part-II-2013 laid in trenches, jointed and tested as per manufacturer instruction complete all as specifed and directed. Make:Gemini-Tirupati Plastimatics Pvt Ltd, Jaipur (Raj)/ Keshav Kripa Polyplast (LLP), Kishangarh (Raj)/ Supreme Ultra Plus, Mumbai
S&F HDPE double wall corrugated sewage pipe of 150 mm internal bore, SN-8, ISI marked as per IS 16908 Part-II-2013 laid in trenches, jointed and tested as per manufacturer instruction complete all as specifed and directed. Make:Gemini-Tirupati Plastimatics Pvt Ltd, Jaipur (Raj)/ Keshav Kripa Polyplast (LLP), Kishangarh (Raj)/ Supreme Ultra Plus, Mumbai
M & L for RCC pipes 150 mm dia, Class NP2 laid in trench/floor/culvert, jointed and tested complete with collars complete all as specified & directed.
M & L for RCC pipes 200 mm dia, Class NP2 laid in trench/floor/culvert, jointed and tested complete with collars complete all as specified & directed.
Supply and laying of salt glazed stone ware pipes 150 mm bore grade 'A' laid in trenches and jointed in CM (1:1) incl testing complete all as specified & directed
M & L concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D2 (using 40mm graged stone aggregtaes) for 100mm mm dia pipe work in foul position complete all as specified & directed.
M & L concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D2 (using 40mm graged stone aggregtaes) for 150mm mm dia pipe work in foul position complete all as specified & directed.
M & L concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D2 (using 40mm graged stone aggregtaes) for 200mm mm dia pipe work in foul position complete all as specified & directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required of anty dia complete all as specified & directed.
v k builder (BID ID -3200701)
d k suppliar (BID ID -3196789)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .