Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹2.0 L
EMD Value
₹2,000
Closing Date
24 Mar 2020, 12:00 pmClosed
SE ETC-II,MORADABAD
220 KV S/S CAMPUS MAJHOLA MORADABAD
WORK OF PATROLLING AND ANNUAL MAINTENANCE OF 132 KV NEHTAUR (220 KV)-NAGINA (S/C) LINE, UNDER ETD DHAMPUR
2020_UPTCL_442766_1
E-T-52/ETC-II/M/2020
Open Tender
Electrical Works
365 days
DHAMPUR
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
EE ETD AMROHA ,SBI CURRENT ACCOUNT NO. 30723557626
₹2,000
27 Mar 2020
4 Mar 2020
24 Mar 2020
4 Mar 2020
24 Mar 2020
4 Mar 2020
Amount
WORK OF PATROLLING AND ANNUAL MAINTENANCE OF 132 KV NEHTAUR (220 KV)-NAGINA (S/C) LINE, UNDER ETD DHAMPUR.
Regular tower to tower ground patrolling of 132 KV Nehtaur (220 KV)-Nagina line S/C (Length-16.5 Kms. approx.) including lopping & chopping of the trees in the 27 meter in corridor for 132 KV lines, detecting defects like missing/theft members of tower, hot point puncture insulator disc, dislocation of vibration dampers/loose conductor/earth wire of following lines. Patrolling shall be done quarterly basis i.e.04 times in a year.
Submission of patrolling report on prescribed computerized performa in 5 sets after each patrolling duly binded along with one soft copy.
Lopping, chopping of trees in the 27 Meters corridor of line and stacking of above cuttings at proper palce far from the line
Fabrication & fixing of tower members including cartage of steel angles from S/S store, punching holes for proper placement tightening of Nuts & bolts punching & chamfering at different tower location of above Transmissin line.
Back filling of earth across the tower foundation wherever required including cost of material, labour, T&P etc. and its tranportation up to the site.
Repairing of foundation coping, wherever required including cost of material, labour, T&P etc and its transportation up to the site.
Strengthening/Replacement of damaged jumpers at tension towers.
Replacement of damaged/puncture insulators string at different tower location including cartage of material from store to work site of the above line. All the manpower & T&P shall be provided by tenderers for completion of work. (A) For Suspension String
(B) For Tension String
Repairing of damaged ACSR Panthar Conductor by providing repair sleeve/mid span joint clamp.
Strengthening of earthwire including replacement/tightening of suspension clamp as per site requirement.
Clearing of nest from the tension tower insulator formed by birds.
Emergency patrolling of 132 KV Nehtaur (220 KV)-Nagina S/C line during tripping to detect the exact fault location & type of fault.
M/S AJAY KUMAR POWER CONSTRUCTION
M/S SATKAR TRADERS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid