Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹3.1 LAccepted-AOC | 1 | Accepted-AOC being lowest | |
| 2 | 2₹3.6 L+₹40,597 (12.8%)Rejected-Finance | 2 | Rejected-Finance Being not Lowest |
Tender Value
₹5 L
EMD Value
₹10,000
Closing Date
26 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I AF JAIPUR
AGE I AF JAIPUR OPP- JAL MAHAL AMER ROAD
REPAIR AND MAINTENANCE OF E/M INSTALLATION AND MISC WORK AT AF STATION JAIPUR
2023_MES_599880_1
8428/E8
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
AGE I AF JAIPUR
Class E and above and category b (I)
8 documents required · 8 mandatory
₹500
AGE I AF JAIPUR
₹10,000
8 Jul 2023
31 May 2023
28 Jun 2023
31 May 2023
26 Jun 2023
14 Jun 2023
31 May 2023 - 10 Jun 2023
Amount
Servicing of DG set ('C' Check) of Capacity 15/40/50/82.5 KVA by representative of authorised service centre as per manufacturer manual and checking of fuel supply system, Lubrication system, cooling system, battery ignition system and rectification of defect if any and including replacement of following, complete all as specified. (a) Lubrication oil filter. (b) Engine Oil. (c) Fuel filter and fuel strainer. (d) Coolent top up. Make of DG set: Mahindra, Ashok Leyland and Kirloskar
M&L for Engine Oil 20W/40 W
M&L for coolent Top up
S&F Fuel Filter for DG set
S&F Oil Filter for DG set
S&F Fuel Strainer for DG set
S&F in replacement Servo controller class 1.0, Aux supply 90-300v, parameters- Vi/P, Vo/P & I complete all as specified and directed. Note: (i) Cost of removing old unservicable controller, cutting in body as per requirement and wiring of new controller deemed to be incuded in unit rate. (ii) Capacity of servo stabilizer is 300KVA and Location: Tropo Technical area under AGE(I)AF Jaipur. Make: Shakti /Vinitec/ Volina or equivalent as approved by Engineer in Charge.
Supply and fix in replacement ON LOAD change over switch 415V, 100 Amp, 4 Pole in sheet metal enclosures complete all as specified and directed. Make: L&T/ Havells/ C&S/Siemens
Supply and fix in replacement ON LOAD change over switch 415V, 200 Amp, 4 Pole in sheet metal enclosures complete all as specified and directed. Make: L&T/ Havells/ C&S/Siemens
M&L for applying two coat of synthetic enamel paint over and incliuding one coat of primer on external surface of LT Panels of any size including preparation of rusted surface of panel by means of sand paper/ scrubing of dust etc complete all as specified and directed. Note: Cost of Minor repair/ replacement of hinges suitable for screw fastners and fixed in original position and necessary welding work deemed to be included in quoted rate.
Servicing and repair of APFC panel upto 200 KVAR by replacement of worn out spare parts and cleaning of the serviceable contactors and tightning/checking of all internal electical connections and accessories to maintain PF not less than 0.98 by adjusting/ calibrating the APFC relay of any type complete all as specified and as directed. Note: Defective parts if any will be measured and paid seprately.
S&F in replacement Heavy duty gas filled Capacitor, 1 KVAR, 440V, 3phase, 50 Hz. Make: L&T/C&S/Epcos/Havells
S&F in replacement Heavy duty gas filled Capacitor, 2 KVAR, 440V, 3phase, 50 Hz. Make: L&T/C&S/Epcos/Havells
S&F in replacement Heavy duty gas filled Capacitor, 5 KVAR, 440V, 3phase, 50 Hz. Make: L&T/C&S/Epcos/Havells
S&F in replacement Heavy duty gas filled Capacitor, 10 KVAR, 440V, 3phase, 50 Hz. Make: L&T/C&S/Epcos/Havells
S&F in replacement Heavy duty gas filled Capacitor, 15 KVAR, 440V, 3phase, 50 Hz. Make: L&T/C&S/Epcos/Havells
S&F in replacement Heavy duty gas filled Capacitor, 25 KVAR, 440V, 3phase, 50 Hz. Make: L&T/C&S/Epcos/Havells
S&F in replacement Heavy duty gas filled Capacitor, 50 KVAR, 440V, 3phase, 50 Hz. Make: L&T/C&S/Epcos/Havells
M & L in replacement Junction box with 6 Amp MCB suitable connection for single phase incoming cable, single phase out going cable endorsed in thermo plastic enclosure, shock proof safe IP 65, weather proof, rust proof, dust and water proof internally embedded gasket with provision for cable entry fitted on street light pole by proper nuts and bolts as required complete all as specified directed by engineer in charge. Make: Hensel/Sintex/Siemens
S & F Automatic street light control switch for automatic switching OFF street light at 10 Lux level and switching ON at 30 Lux of natural light and infrared sensor along with suitable power Contactors of rating 25 Amps single Phase, MCB 25 Amps should be enclosed in pole/wall mountable enclosure made of Rust proof, Electric shock proof, Termite proof and FR grade special moulding compound (thermoplastic polycarbonate) conforming to IP66 protection class 2. The contactors, MCBs and circuit wiring should suitable enough to take load of 3-5 KW equally distribution over single phase 415 Volts A/C (Nature Switch, MCB, Contactor and wiring (copper, min 10Sqmm) suitable for the Make and model) all as specified and directed. (Make: Swadeep Model No. 66-3kW1P or equivalent in Havells/ C&S/L&T.).
M&L for cleaning of Borewell 200/250mm dia with compressed air for minimum 6 hr including disconnecting connection of borewell, taking out submersible pump, cleaning of borewell, lowering the submesible pump and connecting the cables and make functional complete all as specified and directed.
S&F in replacement booster pump (stainless steel monoblock pumpset self priming with automatic pump controller) of capacity 1HP, Min Head 37 metre, Single phase, 230V, 50Hz complete all as specified and directed. Make: Crompton/ CRI/Kirloskar/KSB/Jyoti
S&F in repair Hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard complete all as specified and directed.
S&F in repair Branch pipe gun metal 63 mm instantaneous inlet, made threaded outlet, 15 mm bore nozzle short type, ISI marked, conforming to IS 903 complete all as specified and directed.
S&F in replacement oblique type fire hydrant landing valve single outlet of size 63mm, ISI marked, confirming to IS 5290 complete all as specified and directed.
S&F in replacement LED Bollard Light of capacity 8 watt, 240V AC, 50Hz, PF>0.9, operating voltage 140V-270V AC complete with and including base pipe 50 mm dia fixed with PCC complete all as specified and directed. Make: Cromplton/Bajaj/Philips/Wipro/Havells. NOTE:- Earthwork , PCC and pipe for fixing of light is deemed to be included in quoted rate.
S&F in replacement 0.5 HP motor pump, Self priming, Single phase, 230 V, 50Hz complete all as specified and directed. Make: Crompton/ CRI/Kirloskar/KSB/Jyoti
Supply and fixing in replacement LED light fitting 1x 16 Watt flame proof, CMRI certified recommended for gas/ vapour group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed. Make: Sudhir/FCG /Crompton
M.S. ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .