| 1 | L1₹18.2 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹19.6 L+₹1.4 L (7.82%)Rejected-Finance | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹20.7 L+₹2.5 L (13.8%)Rejected-Finance 43 VIMAL ENCLAVE CHAMRAULI MODE SHAMSHABAD ROAD AGRA UP 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹21.7 L+₹3.5 L (19.5%)Rejected-Finance BUNGLOW NO 1 RAJPOOT VILLA BARARU ROAD PATKUYI BARARU SAGAR MP 470002 | SAGAR | SAGAR | MADHYA PRADESH | 470002 | L4 | Rejected-Finance Not lowest bidder | |
| 5 | L5₹22.0 L+₹3.8 L (20.8%)Rejected-Finance | L5 | Rejected-Finance Not lowest bidder |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
6 Jul 2024, 6:00 pmClosed
GARRISON ENGINEER SAUGOR
Military Engineer services Garrison Engineer Saugor MP- 470001
Repairs/replacement of internal wiring and connected items at Area-I under GE Saugor
2024_MES_658682_1
GE/SGR/TOK-13 OF 2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Saugor
Class D category b (i) and as per tender documents
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER SAGAR
₹70,000
Yes
7 Sept 2024
8 Jun 2024
8 Jul 2024
8 Jun 2024
6 Jul 2024
24 Jun 2024
10 Jun 2024 - 17 Jun 2024
Amount
Taking down carefully copper/aluminum pt wiring (light fan, socket or power) complete including fittings such as switches, sockets, c/roses, lamp holders, tube light fittings, sketch fittings, wooden boards, bell push, call bell, MCBs, & regulators etc & making good to disturbed surfaces & matching with the existing colour of wall/floor etc complete all as specified and directed.
M&L for point wiring with 1.5 Sqmm PVC insulated FRLSH, unsheathed, copper conductor stranded 1100 volt grade cable in & incl PVC Casing -n-caping /conduit of size not less than 20mm ISI marked ivory white with all accessories such as tee, bend, joint cover including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and PVC laminated hylem/Anchor ISI marked top cover 3.0 mm thick for mounting of switches/sockets/ regulator etc and PVC insulated & unsheathed 1100 volt grade copper conductor, stranded 1.5 sqmm. cable as continuous earth lead complete all as specified and directed and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green . Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate.
For one light point or fan point controlled by one switch complete all as specified and directed.
For one Call Bell point controlled by one push button switch complete all as specified and directed.
For 5Amp independent socket point controlled by one switch complete all as specified and directed.
For one 3 pin ,5 Amp socket point with other switch on the same board complete all as specified and directed.
All as per item No 2.00 here in before but for power point wiring using with 2.5 sqmm PVC FRLSH insulated ,unsheathed, copper conductor stranded 1100 volt grade cable and 2.5 sqmm PVC insulated ,unsheathed, copper conductor stranded 1100 volt grade cable as con complete all as specified and directed. Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate.
M&L for concealed point wiring with 1.5 Sqmm PVC-FRLSH insulated, unsheathed, copper conductor, stranded 1100 volt grade cable in & incl PVC conduit, , including of junction and terminal boxes, all fittings such as tees, bends, elbows, etc. of External diameter 20mm all as per site requirements including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and PVC laminated hylem/Anchor ISI marked top cover 3.0 mm thick for mounting of switches/sockets/ regulator etc and PVC insulated & unsheathed 1100 volt grade copper conductor, stranded 1.5 sqmm. cable as continuous earth lead complete all as specified and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green . Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate.
For one light point or fan point controlled by one switch complete all as specified and directed.
For one Call Bell point controlled by one push button switch complete all as specified and directed.
For 5Amp independent socket point controlled by one switch complete all as specified and directed.
For one 3 pin ,5 Amp socket point with other switch on the same board complete all as specified and directed.
All as per item No 3.00 here in before but for power point wiring using with 2.5 sqmm PVC FRLSH insulated ,unsheathed, copper conductor stranded 1100 volt grade cable and 2.5 sqmm PVC insulated ,unsheathed, copper conductor stranded 1100 volt grade cable as con complete all as specified and directed. Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate.
M&L for concealed point wiring with 1.5 Sqmm PVC-FRLSH insulated, unsheathed, copper conductor, stranded 1100 volt grade cable in & incl PVC conduit of size not less than 20mm ISI marked ivory white with including modular metal flush boxes & modular white cover plate of suitable module with frame as per site requirement all fittings such as tees, bends, elbows, etc. all as per site requirements PVC insulated & unsheathed 1100 volt grade copper conductor, stranded 1.5 sqmm. cable as continuous earth lead complete all as specified and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green all as directed by Engr-in-charge . Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate.
For one light point or fan point controlled by one switch complete all as specified and directed.
For one Call Bell point controlled by one push button switch complete all as specified and directed.
For 5Amp independent socket point controlled by one switch complete all as specified and directed.
For one 3 pin ,5 Amp socket point with other switch on the same board complete all as specified and directed.
For one light, point controlled by two way switch complete all as specified and directed.
All as per item No 4.00 here in before but for power point wiring using with 2.5 sqmm PVC FRLSH insulated ,unsheathed, copper conductor stranded 1100 volt grade cable and 2.5 sqmm PVC insulated ,unsheathed, copper conductor stranded 1100 volt grade cable as con complete all as specified and directed. Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate.
S&F Modular switch, one way,6 Amp 230, 1 module .
S&F Modular switch, two way, 6 Amp 230, 1 module.
S&F modular socket 6 Amp-2/3 pin combined 2 module .
S&F Modular switch, one way,6 A/16 Amp 230, 1 module .
S&F modular socket 6 A/16-2/3 pin combined 2 module .
S&F Modular fan step regulator 120 Watt -2 module .
S&F Modular bell push 6A one module .
S&F switch piano type flush, single pole, one way 5 A 230 V.
S&F socket outlet, 3 pin, 5 Amp, flush type, 230 V.
S&F switch piano type flush, single pole, one way 15 A 230 V .
S&F socket outlet 2 in 1,6 pin, 5/15 A, flush piano type 240 V.
S&F ceiling rose, surface backlite,three terminal .
S&F lamp holder insulated with back plate suitable for Angle/Batten fitting.
S & F in repair/replacement bell ding dong 230 V, single phase.
S&F electronic double space rotary 5 speed type regulator 120-280 V .
S&F bell push flush type one way 5Amp 240 Volt.
M&L concealed sub main wiring with two single core PVC FRLSH insulated unsheathed stranded copper conductor cable FRLS, 02 runs of 01 Single core of size 6 sqmm (for main current) drawn in & incl PVC conduit not less than 20mm dia ISI marked with all accessories such as tee, bend, joint cover etc round / square blocks at junctions etc, all as per site requirements ISI marked with one run of 01 Single core of size 6 Sqmm (As earth wire) PVC insulated unsheathed stranded copper conductor as a continuous earth wire complete all as specified incl. taking down old unserviceable sub main wiring and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green complete all as specified and directed. Note: (i) cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate. (ii) Two runs of single core for main current and one run of single core for earth continuity conductor & one run of PVC casing -n-caping/pvc conduit shall be measured as one unit length.
M&L surface conduit sub main wiring with two single core PVC FRLSH insulated unsheathed stranded copper conductor cable FRLS, 02 runs of 01 Single core of size 6 sqmm (for main current) drawn in & incl PVC casing -n-caping/pvc conduit of suitable size not less than 20mm dia ISI marked with all accessories such as tee, bend, joint cover etc round / square blocks at junctions etc, all as per site requirements ISI marked with one run of 01 Single core of size 6 Sqmm (As earth wire) PVC insulated unsheathed stranded copper conductor as a continuous earth wire complete all as specified incl. taking down old unserviceable sub main wiring and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green complete all as specified and directed. Note: (i) cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate. (ii) Two runs of single core for main current and one run of single core for earth continuity conductor & one run of PVC casing -n-caping/pvc conduit shall be measured as one unit length.
M&L sub main wiring with two single core PVC FRLSH insulated unsheathed stranded copper conductor cable FRLS, 02 runs of 01 Single core of size 10 sqmm (for main current and earth ) drawn in & inc PVC Casing-n-caping /pvc conduit of suitable size not less than 20mm dia ISI marked with all accessories such as tee, bend, joint cover etc round / square blocks at junctions etc, all as per site requirements ISI marked with one run of 01 Single core of size 10 Sqmm (As earth wire) PVC insulated unsheathed stranded copper conductor as a continuous earth wire complete all as specified incl. taking down old unserviceable sub main wiring and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green complete all as specified and directed. Note: (i) cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate. (ii) Two runs of single core for main current and one run of single core for earth continuity conductor & one run of PVC casing -n-caping/pvc conduit shall be measured as one unit length.
M&L sub main wiring with two single core PVC FRLSH insulated unsheathed stranded copper conductor cable FRLS, 02 runs of 01 Single core of size 4 sqmm (for main current) drawn in & incl PVC Casing-n-caping of suitable size ISI marked with all accessories such as tee, bend, joint cover etc round / square blocks at junctions etc, all as per site requirements ISI marked with one run of 01 Single core of size 4 Sqmm (As earth wire) PVC insulated unsheathed stranded copper conductor as a continuous earth wire complete all as specified incl. taking down old unserviceable sub main wiring and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green complete all as specified and directed. Note: (i) cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate. (ii) Two runs of single core for main current and one run of single core for earth continuity conductor & one run of PVC casing -n-caping/pvc conduit shall be measured as one unit length.
M&L sub main wiring with two single core PVC FRLSH insulated unsheathed stranded copper conductor cable FRLS, 02 runs of 01 Single core of size 2.5 sqmm (for main current) drawn in & incl PVC Casing-n-caping of suitable size ISI marked with all accessories such as tee, bend, joint cover etc round / square blocks at junctions etc, all as per site requirements ISI marked with one run of 01 Single core of size 2.5 Sqmm (As earth wire) PVC insulated unsheathed stranded copper conductor as a continuous earth wire complete all as specified incl. taking down old unserviceable sub main wiring and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green complete all as specified and directed. Note: (i) cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate. (ii) Two runs of single core for main current and one run of single core for earth continuity conductor & one run of PVC casing -n-caping/pvc conduit shall be measured as one unit length.
M&L sub main wiring with two single core PVC FRLSH insulated unsheathed stranded copper conductor cable FRLS, 02 runs of 01 Single core of size 1.5 sqmm (for main current) drawn in & incl PVC Casing-n-caping of suitable size ISI marked with all accessories such as tee, bend, joint cover etc round / square blocks at junctions etc, all as per site requirements ISI marked with one run of 01 Single core of size 1.5 Sqmm (As earth wire) PVC insulated unsheathed stranded copper conductor as a continuous earth wire complete all as specified incl. taking down old unserviceable sub main wiring and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green complete all as specified and directed. Note: (i) cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate. (ii) Two runs of single core for main current and one run of single core for earth continuity conductor & one run of PVC casing -n-caping/pvc conduit shall be measured as one unit length.
S&F testing and commissioning of MCB SP 240 volt 6 Amp to 40 Amp 10 KA capacity having C-curve characteristics connected with suitable lugs including taking down complete all as specified and directed.
S&F testing and commissioning of MCB SPN 240 volt 16 Amp to 40 Amp 10 KA capacity having C-curve characteristics connected with suitable lugs including taking down complete all as specified and directed.
S&F testing and commissioning of MCB SPN 240 volt 63 Amp 10 KA capacity having C-curve characteristics connected with suitable lugs including taking down complete all as specified and directed.
S&F testing and commissioning of MCB SP 240 volt 63 Amp 10 KA capacity having C-curve characteristics connected with suitable lugs including taking down complete all as specified and directed.
S&F double door metallic sheet metal enclosure for MCB DB double door TPN 4 Way 415 Volts with 200 Amps rated bus bars including taking down complete all as specified and directed. Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate.
S&F in replacement of TPN 63 Amps 415 V including making electrical coming/outgoing connections with lugs/thimbles, including taking down complete all as specified and directed.
S&F sheet metal enclosure for DB double door, IP-43 when MCBs to be used SPN, 12 way, 240 V with 200 Amps rated bus bar including taking down complete all as specified and directed. Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate.
S&F sheet metal enclosure for DB double door, IP-43 when MCBs to be used SPN, 8 way, 240 V with 200 Amps rated bus bar including taking down complete all as specified and directed. Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate.
S&F double door metallic sheet metal enclosure for DB double door(IP-42/43) When MCBs to be used SPN 4 ways, 240 V with 200Amps rated bus bar including taking down complete all as specified and directed. Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate.
S&F metallic sheet metal enclosure for DB Single door(IP-42/43) When MCBs to be used SPN 2 ways, 240 V with 200Amps rated bus bar including taking down complete all as specified and directed. Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate.
S&F of 2 X 2 ultra slip recess mounted luminaire with high brightness 36 Watt LED package and Unique pattern acrylic de-glaring diffuser sheet for glare-free uniform light distribution suitable for armstrong/grid ceiling complete all as specified and directed.
S&F LED Bulk head 13 watt designed for modern homes availave in PIR as well as non PIR sensor with premium quality diffuser for glarefree light and easy to install snapfit installer complete all as specified and directed.
S&F TL fitting 20 watt for surface and wall mounted LED batten with ultra slim polycarbonate LED lighting fixture with high lumen output environmental friendly energy efficient complete all as specified and directed.
S&F double door metallic sheet metal enclosure for DB double door(DPX-125 ) VTPN 4 Way 415 Volts with 200 Amps rated bus bars IP 43- "IK 09 including taking down complete all as specified and directed. Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate.
S&F MCCB 63 Amps 4 pole, 415 V 16 KA including taking down complete all as specified and directed.
S&F MCCB 100 Amps 4 pole, 415 V 16 KA including taking down complete all as specified and directed.
S&F box type LED optic fitting 10 Watt 2 feet box type complete all as specified and directed.
M&L for provn of Earthing complete with galvanised steel earth plate electrode, 600x600x6mm buried directly in ground (Earth pit not less than 2.25M deep below the GL) with top edge not less than 1.5 metres below ground level connected with galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts & washers of GI or steel all as shown in electric plate no 3 connected to earthing test point all as specified or indicated including testing on completion. Note :- (i) The rate quoted shall also deemed to include the cost of GI wire and protection pipe upto 7.5 Mtr beyond the earth plates electrode and also the cost of the Test point. (ii) Joining of GI earth wire with pipe of the test point shall be done by using suitable cable lugs.
S&F in replacement 1100 volts grade heavy duty flat cable PVC insulated stranded aluminium conductor 10 sqmm 2 core over all PVC sheathed in service connection suspended by insulating hangers complete all as specified and directed.
S&F or layng in ground 1100 volts grade heavy duty flat cable PVC insulated stranded aluminium conductor 6 sqmm 2 core in garden light ,lawn etc including PVC regid conduit pipe complete all as specified and directed. Note:- Excavation and earthwork is deemed to include in quoted rates.
S&F metal clad box enclosure with socket plug top and MCB SP 20 Amps flush mounting enclosure with 2 pin and earth plug socket including taking down complete all as specified and directed. Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate.
S&F Modular AC box enclosure with socket plug top and MCB SP 25 Amps flush mounting enclosure complete all as specified and directed. Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate.
S&F in replacement PVC FRLSH insulated and unsheathed single core multi stranded copper conductor 1.5 Sqmm (Nominal Area) drawn in existing conduit / batten / surface complete all as specified and directed.
All as per Item Ser No 49.00 above but size 2.5 Sqmm complete all as specified and directed.
S&F modular PVC board 3/4/6/8/12 module complete all as specified and directed.
S&F normal pvc board complete all as specified and directed.
Taking out old US laminated sheet and S & F new laminated super hylem sheet any colour 3mm thick of sizes 8" x 5" including fixing of switches, sockets as per existing pattern complete all as specified and directed.
All as per Item Ser No 53.00 above but of size 5"x5" complete all as specified and directed.
All as per Item Ser No 53.00 above but of size 8"x10" complete all as specified and directed.
All as per Item Ser No 53.00 above but of size 8"x12" complete all as specified and directed.
All as per Item Ser No 53.00 above but of size 9"x11" complete all as specified and directed.
S&F PVC conduit of size 20mm dia including fixing on wall/ceiling with suitable clamp/saddles for wiring wire all as required at site.
S&F PVC conduit of size 25/32 mm dia including fixing on wall/ceiling with suitable clamp/saddles for wiring wire all as required at site.
S&F PVC casing caping of size 1" x 1/2" including fixing on wall/ceiling with clamp/saddles for wiring wire all as required at site.
Raj Contruction
S S TRADERS
dipangashu barick and associates
shivansh traders
SHRI RAM ELECTRICALS ENTERPRISES
M/s Vinod Kumar Korpal, Sagar
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .