Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC MAIN BAZAR SURANKOTE DISTT POONCH 185121 J K | SURANKOTE | POONCH | J K | 185121 | ₹1.2 Cr | L1 | Accepted-AOC OK |
| 2 | L2₹1.2 Cr+₹3.7 L (3.14%)Rejected-Finance 0 MANPUR CHITBARAGAON CHITBARAGAON BALLIA UTTAR PRADESH 221713 | BALLIA | UTTAR PRADESH | 221713 | ₹1.2 Cr+₹3.7 L (3.14%) | L2 | Rejected-Finance Other than lowest tenderer |
| 3 | L3₹1.3 Cr+₹13.4 L (11.6%)Rejected-Finance | ₹1.3 Cr+₹13.4 L (11.6%) | L3 | Rejected-Finance Other than lowest tenderer |
| 4 | Rejected-Technical | - | - | Rejected-Technical NR being not enlisted in requisite |
Tender Value
₹1.1 Cr
EMD Value
₹1.9 L
Closing Date
11 Sept 2023, 6:00 pmClosed
CWE RAJOURI
HQ CWE Rajouri PIN-900129 C/o 56 APO
AUGMENTATION OF EXTERNAL WATER SUPPLY WITH ALLIED INFRASTRUCTURE AT BG UNDER GE 881 EWS
2023_MES_605405_1
CANO-CWE/PNH-21/2023-24
Open Tender
Civil Works
Lump-sum
180 days
Poonch
Class B and above, Category a(i)
9 documents required · 9 mandatory
₹1,000
GE 881 EWS
₹1.9 L
Yes
6 Nov 2023
24 Jun 2023
18 Sept 2023
24 Jun 2023
11 Sept 2023
28 Aug 2023
Amount
Schedule 'A' Part-I (Building Work)
Total amount of Sch 'A' Part-I (Building work) brought forward from srl page No-21
Schedule 'A' Part-II (Internal Electrification works)
Total amount of Sch 'A' Part-II (Internal Electrificatin works) brought forward from srl page No-23 (R)
Schedule 'A' Part-III (Internal Water supply/Plumbing works)
Total amount of Sch 'A' Part-III(Internal Water supply and Plumbing works) brought forward from srl page No-25
Schedule 'A' Part-IV (Site Clearance works)
Total amount of Sch 'A' Part-IV(Site Clearance works) brought forward from srl page No-26
Schedule 'A' Part-V (Protective works)
Total amount of Sch 'A' Part-V(Protective works) brought forward from srl page No-28 (R)
Schedule 'A'Part-VI(Road/Path/Hardstanding Works)
Total amount of Sch 'A' Part-VI(Road/Path/culvert Works) brought forward from srl page No-30
Schedule 'A'Part-VII(Sewage disposal Works)
Total amount of Sch 'A' Part-VII(Sewage disposalWorks) brought forward from srl page No-32
Schedule 'A'Part-VIII(Area drainage Works)
Total amount of Sch 'A' Part-VIII(Area drainage Works) brought forward from srl page No-33
Schedule 'A'Part-IX(Fencing Works)
Total amount of Sch 'A' Part-IX(Fencing Works) brought forward from srl page No-34
Schedule 'A'Part-X(External electric supply Works)
Total amount of Sch 'A' Part-X(External electric supply Works) brought forward from srl page No-40
Schedule 'A'Part-XI(External water supply Works)
Total amount of Sch 'A' Part-XI(External water supply Works) brought forward from srl page No-42 (R)
Schedule 'A' Part-XII (Misc Items of Works) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.
S & F inverter batten with square profile and polycarbonate channel lithium ion battery with charging time 8-10 hrs and back up time upto 4 hours, LED tube 20 watt including all connected items with connecting up with PVC insulated and sheathed, 1100 V grade, flexible, multistranded copper conductor three core cable complete all as specified and directed.
S&F MCB single pole and neutral 40 amps 240 volts 10 KA 'C' series all as specified. Make:- Havells cat part No-DHMGCSNF040 or Equivalent cat part of make as specified in list of make.
S&F MCB single pole 6 to 32 amps 240 volts 10 KA 'C' series, complete all as specified. Make:-Havells cat part No-DHMGCSPF006-032 or Equivalent cat part of make as specified in list of make.
S&F 4 mm dia galvanised steel wire, 75 mm x 75 mm mesh, made up into mattresses or cages, lapped, wired and laid in position, including closing after filling, complete all as specified and directed.
Supply and fix servo controlled Voltage stabilizer for automatic operation, three phase, naturally oil cooled, copper wound, indoor type & designed for input variation between 310 to 480 V with output voltage stabilized at 415 with accuracy ± 1% phase to phase and 240± 1% phase to neutral of capacity 100 KVA, unbalanced type response time less than 10 milisecond with initially oil filled complete all as specified and directed by Engr-In-Charge.
Construction of platform suitable for 100 KVA Transformer /Voltage stabilizer of size 2.0m x 2.0m x 1.2 m (Plateform shall be made out of brick masonary) one feet below ground level and one feet above ground level hollow space and to be filled by PCC 1:3:6 type C-2 foundation below ground level), made out of 23cm brick masonry in cement mortar 1:6, (below ground level, hollow space to be filled hardcore of size n.exc 63 mm, deposited, spread and levelled in layers not exceeding 15cm thickness, watered and well rammed) & providing 100 mm thick cement concrete 1:2:4 type B-2 as in floor of platform, plastering in CM 1:4, including protection with XPM, gate and chain link fencing, FI 50x6mm rail around the platform fixed with MS post of angle iron frame 50 x50 x 6mm upto 1.20m clear height, supports grouted in PCC 1:2:4 type B-1 foundation complete all as specified and directed by Engr-in- Charge. Note;-Design of steel shall be approved by GE & Weight of gate should not less than 50 kgs.
Supply,installation,testing & commissioning outdoor type factory made assembled Diesel Engine driven generating set as per latest CPCB norms, conforming IS 10001/10002 and Alternator as per IS 133544 and canopy insulation conforming to UL94-HF1 class with silent (acoustic) enclosure with fully wired alternator AC for ambient conditions, for 100 KVA, continuous rating at 415 Volts adjustable at +/- 2.5 %, 0.8 power factor, 4 wire, 50 Hz +/- 1 %, 1500 RPM directly coupled with suitable capacity diesel engine liquid coolent based mounted on common base frame placed on and incl PCC platform with floor mounted fuel tank of adequate capacity with fuel lines, anti vibration pads, standard control & AMF panels and other accessories etc complete all as specified and directed consisting of following :- (A) Prime Mover : Adequate capacity diesel engine of standard design consisting of direct injection type multi cylinder horizontal, suitable for 100 KVA alternator, liquid cooled technology/water cooled conforming to BSS-649 suitable for prime duty gen set of minimum 120 BHP@ 1500 RPM as per latest IS/BSS with multi cylinders to drive independently , alternator as per site condition after generating and reducing power consumed by accessories, direcly coupled through coupling having overload capacity of 10 % for one hour in every 12 hrs continuous running mounted on base frame with following salient features and standard accessories for safe handling & operation of engine as under :
(a) The gen set should have capacity to run continuosly invariable load conditions for unlimited hours and should have a 110 % load capacity of 01 hours in every 12 hours of operation. (b) Air system inlet & exhaust comprising : Dry type paper element air cleaner, restriction indicator/vaccum indicator, intake manifold, exhaust manifold, silencer muftier. (c) Cooling system comprising (i) Radiator to suit ambient conditions. (ii) Cooling system piping. (iii) Thermostat (iv) Pressure cap (v) Coolant inhibitor and (vi) Engine driven fan. (d) Fuel system comprising (i) fuel pump low pressure type (ii) injectors (iii) Cartridge pipe filters primary and sencondary for fuel. (e) Governor :- Electronic Governor for A1 governig of engine speed from NO load to full load. (f) Lub oil system (i) Plate type lub oil cooler (ii) filters lubrication oil (iii) Digital oil pressure guage. (g) Fuel tank :- Draw out type integral fuel tank made of MS sheet (duly painted) of capacity min 100 ltrs or as recommended by manufacturer with level indicator in ltrs, provided with drain plug and air vent/ breather and inlet and outlet connection and cap tank tank be provided for 12 hour running on full load. (h) Electric starting system comprising :- (i) Electrical self starter 12 volts (ii) Engine driven battery charging alternator (iii) Cut out and (iv) suitable size of maintenance free battery with suitable connection terminals and leads for proper battery connection. (j) Digital type RPM Meter with hour meter. (k) Digital type coolant temp guage.
(ix) Safety alarm against high water temperature and low oil pressure (x) Bypass arrangement with rotary type switch AC-4 pole, 200 AMP rating to isolate AMF panel at the time of low voltage and from maintenace point of view. (xi) Auto change over complete with suitable size power contactor of size 200 Amps with tripping relay complete. (xii) Engine starting relay (xiii) Frequency stabilizer auto mechanism to maintain the supply. (xiv) Batter charger suitable to change the battery of 12 v/24 bolt DC with buck/boost system - 01 Nos best in class efficiency, Min harmonics interference vaccum pressure epoxy gel coating on the winding with following :- (xv) Insulation class ''H'' (xvi) Max valtage Dip at full load 0.8 pf lag- <16% (xvii) Max time to built up rated voltage at rated RPM - ,5 Sec provide engine reach the rated speed. Note : Any other part or accesories as prescribed by manufacturer for its good functional performance of suitable capacity. Mounting arrangement : Prime mover and alternator shall be mounted on skid mounting type base frame fabricated from ISMC channel or in sheet metal providing common bed for engine and alternator dierctly coupled together the base frame has provision for grouting on foundation bolt as well as fixing on vibration mount provision is made in base frame for tilting arrangement of DG set as recommended by manufacturer. The base frame shall have provision for mouting of acoustic enclosure. The base frame to have provision of lifting hook cnvenient lifting of complete set i.e along conopy engine and alternator controller :- (i) Microprocessor based with graphical LCD display. (ii) Best in class monitoring and diagnostic capabilities. (iii) Comunication configuration enabled.
S&F LED street light fittings 45W made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 complete with housing with all accessories pre wired with and including 32mm dia GI pipe bracket of 1.2 mtr made to shape as required fixed on wall or pole with FI clamp of required shape & 40x6mm siize, nut, bolts, washers and making connection with three core copper flexible cable of suitable size to light fitting, complete all as specified and directed. Make:-Havells Cat Part No:- ENDURAPEARLNEOSL45WLED757PASYTOPC or Equivalent cat part of make as specified in list of make.
S & F FRP pole mounting box weather proof type of size 155mm x 155mm x 100mm with three terminal and one 6 Amps MCB mounted inside complete all as specified and direcyed by EIC. Make: Sintex/National/Standard.
Supplying, installing, testing and commissioning LT outdoor type panel board factory fabricated cubical kiosk type whether vermin proof with IP-54, with locking arrangement and made out of MS sheet 3.00 mm thick suitable size of channel for base complete with 500 Amps rated aluminium bus bar chamber and cable alley chamber including cable gland of suitable size and adequate nos and cabinet for housing mounting switch disconnection fuse unit metering eqpt prewired with suitable size of copper conductor and dully factory powder coated mounted on PCC (1:4:8) platform commissioning washer chamber and panel board fixing an angle iron frame which is made out of 40 x 40 x 6 mm thick angle iron duly marked the incoming outgoing controls and comprising with the following:- a) Aluminium bus bar capacity 400 Amps for 3 Phase & neutral b) Incomming MCCB 4 pole 35 KA 200 Amps - 1 Nos With ICS=ICU=100%. c) Outgoing MCCB TPN 35 KA 100 Amps - 2 Nos With ICS=ICU=100%. d) Outgoing MCCB TPN 35 KA 63 Amps - 2 Nos With ICS=ICU=100%. (Spare) e) MCB SPN 10 KA 40-63 Amps railed mounted - 2 Nos f) Digital Ammeter 0-200 amp - 01 Nos g) Digital Voltmeter 0-415 V - 01 Nos
Supply and fix centrifugal pump set with motor 40 HP(30 KW) stage 9, RPM 2900, impeller cast iron, 98 Mtr head with output 60 cum/hrs complete with coupling and foundation all as specified and directed by Engr -in- charge. Make : Kirloskar, Model No of pump RKB 65/19 E 9 stage or equivalent make as specified in list of make.
Supply and fix oil immersed star Delta Starter of capacity 40 HP Motor, three phase, 415 Volt with thermal overload relay ,single phasing protection and free mechanism with single contact duly oil filled including testing complete all as specified and directed by Engr -in- Charge.
S&F foot valve cast iron body, swing type 100 mm bore, rigid and sturdy design with minimum loss of head across the the valve perfectly flat seating surface for good seating, preventing entry of foreign body to pump through suction pipe, long service life conforming to IS 4038, complete all as specified and directed.
S&F cast iron air release valve with single air outlets, conforming to IS 14845 of size 100 mm dia bore and fixing up in cast iron water supply mains of size 100 mm complete all as specified and directed.
Supply and fixing flange for GI pipes 100 mm dia with drilled six holes including necessary welding work and fixing with suitable size of nuts aand bolts washers, gaskets, rubber insulation, packing rings and packing materials etc incl testing leak test on completion of work, complete all as specified and directed.
Construction of conventional type septic tank designed to carry sewage and sludge water for 05 users with & including earthwork in any type of soil, 100 mm thick PCC 1:4:8 below foundation, vent shaft & making connection, complete alol as specified.
M&L for Brick masonary chamber (Valve pit) for opening and closing valve with internal dimensions of size 110x110x90cm build in CM 1:6 over 100 thick PCC 1:4:8 foundation below brick work and 15 mm thick plaster in CM 1:4 internally to brick wall, 40 mm thick coping in CM 1:4 & including necessary excavation and earth work in any type of soil/strata including fixing MS sheet cover 6 mm thick over angle iron frame of size 25x25x6mm with laying and locking arrangement with two coat of synthetic enamel paint over one coat of red oxide primer, complete all as specified and directed.
M&L for wire netting of galvanized steel wire 4 mm dia and size of mesh 12mm x 12mm with tinned tacks of wire staples complete all as specified and directed.
NATIONAL TRADING COMPANY
M/S KEWAL KRISHAN SANJEEV KUMAR VAID
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .