Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹2.0 LQualified Item Categories: Material and labour for de scaling and cleaning of chocked pipes of water circulating lines,M and L | Item Categories: Material and labour for de scaling and cleaning of chocked pipes of water circulating lines,M and L | ₹2.0 L | L1 | Qualified |
| 2 | L2₹2.0 L+₹1,091 (0.54%)Qualified Item Categories: Material and labour for de scaling and cleaning of chocked pipes of water circulating lines,M and L 01 SALIYA GIRIDIH MADHUPUR MAIN ROAD BENGABAD GIRIDH JHARKHAND 815312 | GIRIDIH | JHARKHAND | 815312 | Item Categories: Material and labour for de scaling and cleaning of chocked pipes of water circulating lines,M and L | ₹2.0 L+₹1,091 (0.54%) | L2 | Qualified Category: General |
| 3 | L3₹2.1 L+₹2,646 (1.30%)Qualified Item Categories: Material and labour for de scaling and cleaning of chocked pipes of water circulating lines,M and L | Item Categories: Material and labour for de scaling and cleaning of chocked pipes of water circulating lines,M and L | ₹2.1 L+₹2,646 (1.30%) | L3 | Qualified Category: General |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
23 Mar 2023, 6:00 pmClosed
Maint of Central AC Plant
4564219
GEM/2023/B/3260581
Single Packet Bid
Material and labour for de scaling and cleaning of chocked pipes of water circulating lines,M and L
10 days
Uttar Pradesh; Lucknow
Total value wise evaluation
BOQ
Exempted
23 Mar 2023
13 Mar 2023
23 Mar 2023
| Item No | Item Title | Description | Qty | Unit | Consignee | Delivery (days) |
|---|---|---|---|---|---|---|
| 1 | Material and labour for de scaling and cleaning of chocked pipes of water circulating lines | Material and labour for de scaling and cleaning of chocked pipes of water circulating lines including service valves condenser heat Exchanger to cooling tower by circulating concentrated de scaling solution concentrated hydrochloric acid mixed with water in suitable proportion till the complete deposits scale is removed but min 24 hours whichever is later and as ordered circulating through pump servicing of valves cooling tower water spray assembly cleaning with suitable size of drill rod wire brush including dismantling and connecting all dismantled components in proper position after servicing overhauling greasing etc replacement of packing gasket 3mm thick nuts bolts with washer testing of water line for leakage complete all as specified and directed for central AC plant 3x20 TR | 3 | Each Job | Lucknow | 10 |
| 2 | M and L for carrying out pressure leak test by nitrogen gas of the system of AC plant 3x20 TR | M and L for carrying out pressure leak test by nitrogen gas of the system of AC plant 3x20 TR for leak proof valve joints seal and other connected contracts etc including identifying and rectifying of leakage if any and maintaining constant pressure of 160 PSI on lower side and 300 PSI on higher side for 24 hours complete all as directed by EIC Note Tand P and nitrogen gas shall be arranged by the contractor at his own cost | 1 | Each | Pumping Back The Refrigerant Lucknow Gas To ASeprate Gas | 10 |
| 3 | Pumping back the refrigerant gas to a seprate gas cylinder from the AC plant before leak test | Pumping back the refrigerant gas to a seprate gas cylinder from the AC plant before leak test with the help of required Tand P and charging back the same refrigerant gas to the AC Plant after the leakage test complete all as specified and directed | 50 | Kgs | Lucknow | 10 |
| 4 | M and L for charging of refrigerant gas | M and L for charging of refrigerant gas R22 in central AC plant 3x20TR capacity including provision of all T and P as required at site | 70 | Kgs | Supply And Fixing In Replacement Lucknow Of Oil Seal Assembly | 10 |
| 5 | Supply and fixing in replacement of Oil seal assembly | Supply and fixing in replacement of Oil seal assembly of open type reciprocating compressor 20 ton capacity | 2 | Each | M And L For Replacement Lucknow Of VFan Belt | 10 |
| 6 | M and L for replacement of V fan belt | M and L for replacement of V fan belt B 98 Make DUNLOP Fenner | 8 | Each | M And L For Replacement Lucknow Of Unserviceable Thermal Over | 10 |
| 7 | M and L for replacement of Unserviceable thermal over load relay | M and L for replacement of Unserviceable thermal over load relay of various ranges as per existing make and model starting from 9 Amps to 42 Amps complete all as specified and directed | 2 | Each | M And L For Replacement Lucknow Of Unserviceable Single | 10 |
| 8 | M and L for replacement of Unserviceable single phase preventer auxiliary volts 415 volts | M and L for replacement of Unserviceable single phase preventer auxiliary volts 415 volts | 2 | Each | Lucknow | 10 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_4564219.pdf
GEM_BID
maint-of-ac-central-hall_2023-03-13-17-07-37_1ce00942b3db48d1a38400c38fc436d7.pdf
BOQ
boq-ac-plant_2023-03-13-17-07-37_16632e3849f60b7e1ef2f7d65d07fc4a.csv
BOQ
gtc.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .