Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹71.8 CrAccepted-AOC | ₹71.8 Cr | L1 | Accepted-AOC BEING LOWEST |
| 2 | L2₹78.5 CrRejected-Finance PREMISES NO 5 30 5 N C SENGUPTA SARANI GROUND FLOOR MALL ROAD KOLKATA WEST BENGAL INDIA 700 080 | KOLKATA | KOLKATA | WEST BENGAL | 700080 | ₹78.5 Cr | L2 | Rejected-Finance NOT BEING L1 |
| 3 | Rejected-Technical | - | - | Rejected-Technical Not completed Building works as per PQC |
| 4 | Rejected-Technical | - | - | Rejected-Technical No experience of Multi-storeyed building Deficiency in PQC |
| 5 | Rejected-Technical MANATHA ENCLAVE 3RD FLOOR OLIMUGAL KAKKANAD P O KOCHI 682 030 KERALA | ERNAKULAM | KERALA | 682030 | - | - | Rejected-Technical Not completed Building works as per PQC |
Tender Value
Refer Docs
EMD Value
₹15 L
Closing Date
31 May 2021, 6:00 pmClosed
CHIEF ENGINEER CG GOA
CHIEF ENGINEER CG GOA 403806
CONSTRUCTION OF DEFFICIENT MARRIED ACCOMMODATION FOR COAST GUARD ENROLLED PERSONNEL EPS AND CIVILIANS AT COAST GUARD DHQ4 KOCHI
2021_MES_428014_1
82011/E8
Open Tender
Civil Works
780 days
Kochi
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹3,000
GE (I) (CG) KOCHI
₹15 L
Yes
HQ CE CG GOA
20 Jul 2021
4 Mar 2021
2 Jun 2021
4 Mar 2021
31 May 2021
5 May 2021
15 Mar 2021
Amount
SCHEDULE "A" Part - I (BUILDING/ STRUCTURE WORKS) Details of prepriced schedule is given in tender documents.
SCHEDULE "A" PART-II ( SITE CLEARENCE/ DEVOLOPMENT/ EXCAVATION AND EARTHWORK) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-III (INTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IV (INTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-V (ROAD/ PATH/ HARDSTANDING) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VI (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VII (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VIII (EXTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART- IX (FIRE FIGHTING) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-X (LIGHTENING PROTECTION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XI (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART -XII (MISCELLANIOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.' E ' signifies this fact only.
INTERNAL WATER SUPPLY S & F Two way aerator bib tap 15 mm complete all as specified & directed Make – Drizzel or equivalent in list of approved make attached
S & F Health faucet with wall hook Make Hindware Model No F160027 or equivalent in list of approved make attached complete all as specified.
S&F, PP-R Gate valves 63 mm dia,(brass insert) complete all as specified
INTERNAL ELECTRIC SUPPLY S & F modular type bell ding dong of 2 module size, conforming to IS: 8884- 1978 complete all as specified and directed. Make: Legrand Arteor Cat-Part No. 5734 43 or equivalent in list of approved make attached
S & F modular type 1 module TV socket complete all as specified and directed. Make: Legrand Arteor Cat-Part No. 5734 25 or equivalent in list of approved make attached
S & F modular type 1 module RJ 11 telephone socket with shutter complete all as specified and directed. Make: Legrand Arteor Cart-Part No. 5734 26 orequivalent in list of approved make attached
S & F 20 W surface/wall mounted LED batten having high efficiency long life LED chips with luminous efficacy of > 100 lumen/W, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing and white coloured ABS end caps having input voltage 220- 240 V, input frequency 50- 60 Hz, PF > 0.95, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed. Make: BAJAJ Cat-Part No. BCLAB 20W or equivalent in list of approved make attached
S & F 10 W surface/wall mounted LED batten having high efficiency long life LED chips with luminous efficacy of > 100 lumen/W, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing and white coloured ABS end caps having input voltage 220- 240 V, input frequency 50- 60 Hz, PF > 0.95, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed. Make: BAJAJ 112407 Cat-Part No. BCLSB 10W or equivalent in list of approved make attached
S & F 16 W surface/wall mounted LED batten having high efficiency long life LED chips with luminous efficacy of > 100 lumen/W, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing and white coloured ABS end caps having input voltage 220- 240 V, input frequency 50- 60 Hz, PF > 0.95, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed. Make: Phillips or equivalent in list of approved make attached
S & F 35/36 W surface/wall mounted LED batten having high efficiency long life LED chips with luminous efficacy of > 100 lumen/W, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing and white coloured ABS end caps having input voltage 220- 240 V, input frequency 50- 60 Hz, PF > 0.95, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed. Make: Philips Cat No. BN308C LED40S-6500 L120 PSUWH or equivalent in list of approved make attached
S & F 20 W LED street light having high efficiency long life LED module with SMD LED package mounted on MCPCB with high LED efficacy of ≥ 100 lumen/W, integral SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, IP 66 protection, high effiency polycarbonate cover with integrated lens housed in pressure die-cast aluminium alloy heat sink for effective thermal management, sturdiness, excellent corrosion resistance, separate optical and control gear compartment & top opening for easy maintenance, suitable for side entry, pole mounting with bracket 1.5 m long with including necessary electrical connection to the fixture with 3 core flexible Cu conductor cable of appropriate size and light grade GI pipe 20mm dia, including GI clamps, nuts, bolts & washers with two coats of synthetic enemal paint over a coat of red oxide primer complete all as specified and directed. Make: BAJAJ Cat-Part No. BAJAJ 169829 BCLST 20W LED I or equivalent in list of approved make attached
S & F BEE five star rated energy efficient high-speed ceiling fan having 1200 mm blade sweep, air-flow not less than 210 CMM, operating voltage 220-240 V and frequency 50 Hz, including a downroad of suitable size and electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fan complete all as specified and directed. Make: Crompton Cat-Part No. ENTRUST50 or Havells Cat- Part No. ES-50 or equivalent in list of approved make attached
S & F engery efficient non-metalic fresh air fan having blade sweep 250 mm, air delivery not less than 860 CMH, operating voltage 220-240 V and frequency 50 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fresh-air fan complete all as specified and directed. Make: Crompton Cat-Part No. VENTILUS 10" or equivalent in list of approved make attached
S & F engery efficient metalic exhaust fan having blade sweep 300 mm, air delivery not less than 900 CMH, operating voltage 220-240 V and frequency 50 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fresh-air fan complete all as specified and directed. Make: Crompton Cat-Part No. TRANS AIR 12" or equivalent in list of approved make attached
Supply, installation, testing and commissioning of factory made, CPRI type tested, indoor cubical compartmental type BUILDING PANEL (G+10) of suitable size, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 43 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enamelled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete all as specified and directed by engineer-in-charge.The Building Feeder Panel shall comprise of the following: [A] BUSBAR CHAMBER [i] 01 Set (3L + N) of copper busbar of rated capacity 400 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection [B] INCOMING [i] 160 A, 415 V, Ics = 100% Icu = 50 kA, 50 Hz FP MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (Ready, Overload and pre-alarm & Overload), etc. [ii] LED phase indicators (Red, Yellow, Blue)- 01 Set [B] OUTGOING [i] 32 A, 230 V, Ics = 100% Icu = 10 kA, 50 Hz SPN MCB. (for 42 QTR ) [ii] Space for energy meter- 42
Supply, installation, testing and commissioning of factory made, CPRI type tested, indoor cubical compartmental type BUILDING PANEL (G+8) of suitable size, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 43 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enamelled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete all as specified and directed by engineer-in-charge.The Building Feeder Panel shall comprise of the following: [A] BUSBAR CHAMBER [i] 01 Set (3L + N) of copper busbar of rated capacity 400 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection [B] INCOMING [i] 160 A, 415 V, Ics = 100% Icu = 50 kA, 50 Hz FP MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (Ready, Overload and pre-alarm & Overload), etc. [ii] LED phase indicators (Red, Yellow, Blue)- 01 Set [B] OUTGOING [i] 32 A, 230 V, Ics = 100% Icu = 10 kA, 50 Hz SPN MCB. (for 32 QTR ) [iii] Space for energy meter- 32
Supply, installation, testing and commissioning of Cl1.0 accuracy , Tamper Proof, high durability, sleek LCD display energy meters having current range 10-60 A, capable of measuring kWh parameters complete all as specified and directed. 1- Phase energy meter (10-60 Amp) Make: L&T Cat-Part No. WM101BC7DDH or equivalent in list of approved make attached
S & F MCB for AC applications conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, biconnect IP 20 protected lower terminals and sliding shutters, etc. complete all as specified and directed by engineer-in-charge. Make: Schneider, Legrand, Havells 6 A, SP MCB, C- curve
10 A, SP MCB, C- curve
16 A, SP MCB, C- curve
20 A, SP MCB, C- curve
20 A, DP MCB, C- curve
10 A, DP MCB, C- curve
Supply, installation and commissioning of 5 Star rated 25 Litre electric geyser having temperature sensitive LED indicators, shock safe plug, PUF insulation, incoloy glass coated heating element, anode rod, adjustable knob, multi-functional safety valve with IP 4X protection all complete as specified and directed. Make: Havells Cat-Part No. GHWAPTTIV025 or equivalent in list of approved make attached
EXTERNAL WATER SUPPLY Supplying and laying of Ductile iron pipe, DI S/S class 'K 7' of size 150 mm (6" dia) including specials laid in trenches, floors etc. all as specified and directed by Engr-in-Charge.
Supplying and laying of Ductile iron pipe, DI S/S class 'K 7' of size 100 mm dia.
Supplying and laying of GI Steel tubes, heavy duty, Class 'C' of size 80 mm including all standard fittings laid in trenches, floors etc. all as specified and directed by Engr-in-Charge.
Supplying and laying of GI Steel tubes, heavy duty, Class 'C' of size 50 mm all as specified of size 50mm outer dia.
Supply and fix sluice valve PN 1.0 of size 150 mm as per IS Specification complete with and including flanges, leather washers, rubber gasket, bolts, nuts all as specified and directed by the Engr-in-charge.
Supply and fix sluice valve PN 1.0 of size 100 mm as per IS Specification complete with and including flanges, leather washers, rubber gasket, bolts, nuts all as specified and directed by the Engr-in-charge.
Supply and fix sluice valve PN 1.0 of size 80 mm as per IS Specification complete with and including flanges, leather washers, rubber gasket, bolts, nuts all as specified and directed by the Engr-in-charge.
Supply and fix sluice valve PN 1.0 of size 50 mm as per IS Specification complete with and including flanges, leather washers, rubber gasket, bolts, nuts all as specified and directed by the Engr-in-charge.
Supply and fix non return sluice valve PN 1.0 of size 80 mm as per IS Specification complete with and including flanges, leather washers, rubber gasket, bolts, nuts all as specified and directed by the Engr-in-charge.
Supply, installing, testing and commissioning of electrically driven pump set as per specification, motor TEFC type, 2900 rpm, 420 V, 50 Hz, 3 ph, class 'F' insulation, IP 55 protection, not less than 16 HP, starting on suitable DOL/Star Delta starter. The pump shall be horizontal, end suction, top discharge. The pump shall have cast iron casing, cast iron/bronze impeller(as per manufacturer), carbon steel shaft with common base frame (fabricated mild steel channel frame or cast iron type) placed on RCC (1:2:4) including foundation bolts, nuts etc. complete with antivibrator pad as required capable of discharging not less than 1040 LPM at 45 mtr head inclusive of suitable rated 3 ph starter as recommented by the manufacturer, PVC insulated copper cable connection from starter to the motor terminals all as specified and directed by the Engineer-in-charge.
M & L Valve chamber of internal size 1.20 m X 1.20 m X 1.20 m (internal dimentions) including excavation of earth work in any type of soil, 150mm thick PCC in 1:4:8 type D2 foundation , brick work in CM 1:6, 15 mm thick rendering in CM 1:4 to both internal and external surfaces upto 150mm depth below GL, PCC 1:3:6 type C1 as in coping, cover with two Nos of hinges and one No. handle made out of MS round bar 10mm dia with necessary locking arrangement including painting to the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as shown on drg and as specified. Note:- The estimated cost includes all earthwork and connected items.
EXTERNAL ELECTRIC SUPPLY: Supply,install,test and commision LT panel board, Outdoor type, factory made, powder coated , dust and vermin and weather proof, Cubicle type made out of 3.15 mm thick CRCA Sheet & MS angle iron section of 50X50X6 mm frame, front operated with locking arrangements. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands and provision for louvers and air vent gasket for natuaral flow of air . The panel board shall have suitable busbar chamber having sufficient space to pass through UG Cables and have compartments for each control gear and metering devices. Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size 'F' class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. (Main Panel) (FB-1) Copper busbar for 3 phase,440 volts, 50Hz, 4 wire system of rating 1500 Amps for phases and 750 Amps for Neutral. Incoming:-ACB 4 pole, 415 Volts, manual draw out type with micro processor release of capacity 800 Amps-01 No. Metering Unit:- (a) R Y B Indications (LED Type) - 1 sets (b) Digital Multi function meter - 01 No ( c) CT's - 800/5A, CL-1,15 VA - 1 set. Outgoing:- (a) MCCB, 4 pole, 415 Volts, 160 Amps, breaking capacity 25 KA- 06 Nos. (b) MCCB 4 pole,415 Volts, 32 Amps, breaking capacity 36 KA- 01 No.
Supply,install,test and commision LT panel board, Out door type, factory made, powder coated , dust and vermin and weather proof, Cubicle type made out of 2 mm thick CRCA Sheet & MS angle iron section of 50X50X6 mm frame, front operated with locking arrangements. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands and provision for louvers and air vent gasket for natuaral flow of air . The panel board shall have suitable busbar chamber having sufficient space to pass through UG Cables and have compartments for each control gear and metering devices. Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size 'F' class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge.(DG Panel FB-2) Copper busbar for 3 phase,440 volts, 50Hz, 4 wire system of rating 500 Amps for phases and 250 Amps for Neutral. Incoming:- (a) Onload changeover switch 415 Volts AC,50 Hz, 4 pole 160 Amps.-01 No. (b) MCCB 4 pole,415 Volts, 160 Amps, breaking capacity 36 KA- 01 Nos. Metering Unit:- (a) R Y B Indications (LED Type) - 1 sets (b) Digital Multi function meter - 01 No. ( c) CT's - 160/5A, CL-1,15 VA - 1 set Outgoing:- (a) MCCB 4 pole,415 Volts, 40 Amps, breaking capacity 36 KA- 05 Nos.. (b) MCB, TPN, 415 Volts, C curve, 32 Amps, breaking capacity 10 KA- 02 Nos. (c) Digital Timer with contactor TP 32A -01 Nos (d) Panel mounted Energy meter 6-32A
Supply,install,test and commision LT panel, Indoor type, powder coated , dust and vermin and weather proof outdoor, Cubicle type, outer shell made out of 2.0 mm thick CRCA Sheet & MS angle iron section of 50X50X6 mm frame , factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides having chromium plated 19 mm dia fancy keys, louvers & air vent gasket for natuaral flow of air. Suiable gasket shall be used to make the outer shell completely vermin proof. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2.0 mm thick CRCA Sheat duly compartmentalised for each control gear with louvers and air vent gasket for natuaral flow of air and suiatable provision to accomodate incomer/outgoing MCCB's/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables. Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size 'F' class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Location:- (Type-III -01 No. Type-II- 03 Nos).Aluminium busbar for 3 phase,440 volts, 50Hz, 4 wire system of rating 200 Amps for phases and 100 Amps for Neutral. Incoming:- (a) MCCB 4 pole, 415 Volts, 63 Amps, breaking capacity 36 KA- 01No. Metering Unit:- (a) R Y B Indications (LED Type) - 1 sets (b) Digital Multi function meter - 01 No (c) CT's - 800/5A, CL-1,15 VA - 1 set. Outgoing:- (a) MCCB 4 pole, 415 Volts, 32 Amps, breaking capacity 25 KA- 02 Nos. (b) MCB TPN, 415 Volts, 32 Amps, 10 KA- 02 Nos. (c) Digital Timar with contactor TP 32-01No (d) Panel mounted Energy meter 3Phase 6-32A- 04 Nos
Supply,install,test and commision LT feeder pillar box type panel,outdoor type, powder coated , dust and vermin and weather proof outdoor, Cubicle type, outer shell made out of 3.15 mm thick CRCA Sheet & MS angle iron section of 50X50X6 mm frame , factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides having chromium plated 19 mm dia fancy keys, louvers & air vent gasket for natuaral flow of air. Suiable gasket shall be used to make the outer shell completely vermin proof. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2.0 mm thick CRCA Sheat duly compartmentalised for each control gear with louvers and air vent gasket for natuaral flow of air and suiatable provision to accomodate incomer/outgoing MCCB's/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables. Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size 'F' class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. (Location: Pump House FPB - 01 no.) Aluminium busbar for 3 phase,440 volts, 50Hz, 4 wire system of rating 200 Amps for phases and 100 Amps for Neutral. Incoming:- (a) MCCB 4 pole, 415 Volts, 63 Amps, breaking capacity 36 KA- 01 No. Metering Unit:- (a) R Y B Indications (LED Type) - 1 sets (b) Digital Multi function meter with KWH and KVARH function - 01 No ( c) CT's - 800/5A, CL-1,15 VA - 1 set. Outgoing:- (a) MCCB, 4 pole, 415 Volts, 32 Amps, breaking capacity 25 KA- 01 No. (b) MCB, TP, 415 Volts, 32 Amps, 10 KA- 02 No. (c) MCB, SPN, 230 Volts, 32 Amps, 10 KA- 01 No. (d) Star Delta starter suitable for motor up to 20HP
Supply and fix Street light fitting pressure die cast aluminium housing with heat resistant toughened glass and IP 66 potection of 45 Watt 230 V LED street light fitting complete with LED lights prewired and fixing accessories ie nut,bolt washers incl submain wiring with 2x2.5 + 1x 1.5 sqmm PVC insulated FRLS copper conductor dran into PVC conduit pipe including fixing clamps from terminal box to Light fitting complete including suitable GI brackets made of GI light grade pipe 40 mm dia. 1.5 mtr long bent into shape including fixing arrangement wirh FI clamp, necessary welding works, bolts, nuts,washers etc complete. all as specified and as directed by Engr- in- Charge.
Supply and fixing post-top, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source 25 watts 230 Volt
Supply and fixing poly carbonate street light junction boxes IP 66/67 Weather proof suitable for outdoor installation having minimum size 310 x 210 x 116 mm including suitable Cable connecting terminals, cable lugs, including provn of one No MCB SP 6 Amps for operating the streetlight fittings, Suitable Cable Glands as per site requirement, all as directed by the Engineer-in-Charge.
Supply and spread LT Rubber mat of 1 mtr x 2 mtr x 19 mm
Supply Install testing & Commissioning 11KV UNIPACK Compact Sub-Station with 500 KVA ONAN OUTDOOR TYPE Transformer .The 11KV Outdoor Package Sub-Station shall be consisting of following, (A) HT SWITCHGEAR (i) 11kV 630Amps 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of (CV) One numbers of Fixed Manual Load break switch and One Number Fixed Manual Vacuum Circuit Breaker in SF6 insulated stainless steel enclosure (2.5 mm thick) with series trip, self powered microprocessor based numerical over current and earth fault relay protection . Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium Unarmoured XLPE cable (Make: ABB India Limited) - 01 Nos (ii) Incoming and Outgoing Load break switches shall be suitable for cable termination of 3C x 300 sq.mm Cable. (iii) Relay shall be of self powered Ashida/C&S make (50,50N,51,51N) - 01 No (iv) Protection CT shall be 40/1A 2.5VA 10P10.(Make: Ericon/Bharti Electricals/ ECS/Equiv) - 01 set (v) Transformer protection WTI/OTI-Trip & Alarm - 01 set (vi) Shunt trip Coil 24V DC - 01 set (vii) Mechanical Indication ON-OFF-TRIP - 01 set (viii) Voltage Presence Indicator for all module - 01 set (ix) Manometer - 01 No All modules of the RMU shall be capable for cable termination of 3Cx300Sq.mm unarmored ALXLPE Cable, incoming cable termination kits shall be in the scope of purchaser only.
(B) TRANSFORMER (i) 500KVA 11KV/415V Dyn11 Oil filled Hermatically sealed transformer with corrugated wall,without conservator type of design & Top normal porcelein Bushings for HT & LT with Off load tap switch of range +5% to -5% @2.5%. Temp Rise -Oil/Winding 40/45 Deg cel. Losses (As per IS 1180 Energy Efficiency level as per ECBC 2)Maximum Losses at 50% Loading- 1510 W / Maximum Losses at 100% Loading - 4300 Watts and Impedance of 4.5% (Subjected to IS Tol) - 01 No (ii) Oil and winding Temperature Indicator with 1 alarm and trip contact- 01 No (C) LVS PANEL 800AMPS Aluminum Busbar (100% FOR PHASES AND 50% FOR NEUTRAL) - CURRENT DENSITY OF Aluminum as 1 A/sq.mm. LT panel shall be made up of 1.5mm/2mm thick CRCA sheet INCOMING FROM TRANSFORMER 800 Amps 433V 4P 50Hz 50kA EDO Type (ACB) with Microprocessor based release for Overload , Shortcircuit and earth Fault protection with comminucable port & SCADA Compatible(Make: ABB India Ltd) - 01 No
AVAITION LIGHTS: Supply and fix aviation obstruction light integral aviation light comprising of aluminmium housing with poly carbonate enclosure 302 nod LED. Make Bajaj Cat No. BGAV 302 LED or equivalent in list of approved make attached
Supply,fix including testing comissioning XLPE insulated screened PVC bedded galvanised steel strip or wire armoured power cable (Heavy duty) 1100 V grade with stranded aluminium conductor of size 2 core 6 Sqmm on poles /walls as cable for aviation obstruction light all as specified and directed.
S&F timer switch and MCB SPN, 230 V, 10 Amp enclosed in a metal enclosure.
Fire fighting Supply, connect, joint and lay MS flanged pipe heavy duty ISI marked with all fittings of size 100 mm dia with flanged ends and including flanges, leather gaskets, heavy duty bolts, nuts, washers etc, laid in trenches,floors, fixed on walls/floors/roof ete including fixing with clamps on wall for the wet riser including painting with approved synthetic enamel paint all as specified and directed by Engr-in-charge.
Supply, connect, joint and lay MS flanged pipe heavy duty ISI marked with all fittings of size 80 mm dia with flanged ends and including flanges, leather gaskets, heavy duty bolts, nuts, washers etc, laid in trenches,floors, fixed on walls/floors/roof ete including fixing with clamps on wall for the wet riser including painting with approved synthetic enamel paint all as specified and directed by Engr-in-charge.
Supply & Fix Cast iron air release valve with single air outlet, conforming to IS 14845 of size 50 mm. dia. Bore and fixing up in Cast iron water supply mains complete aii as specified and directed by Engr-in-charge.
Supply, installation, testing and commissioning of Analog addressable type active Loop Repeater (Loop power/External power) fire terminal with inbuilt turbo isolator, Backlit LCD display 6 X 40 characters display, having controls for reset, mute, accept, silence alarms and self test with programmable free keys and duly approved by EN54/LPCB/VDS/FM Make:- SIEMENS/NOTIFIER/BOSCH
Supply, installation testing and commissioning of XLPE insulated electric cable with copper coductor of size 1.5 sq.mm, 2 core suitable for working pressure 1100 Volts to IS:7098 and drawn into PVC coduit pipe 20 mm. all as specified and directed.
S&F wall mounted LED emergency Exit signage luminaire Light up using regular mains supply comes with a unique rechargeable Ni-Cd battery capable of emergency back up upto 05 hours (Cat No LSSR5W Make CG or equivalent to Bajaj/havells.
Supply,install,test and commision LT feeder pillar box type panel,outdoor type, powder coated , dust and vermin and weather proof outdoor, Cubicle type, outer shell made out of 3.15 mm thick CRCA Sheet & MS angle iron section of 50X50X6 mm frame , factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides having chromium plated 19 mm dia fancy keys, louvers & air vent gasket for natuaral flow of air. Suiable gasket shall be used to make the outer shell completely vermin proof. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2.0 mm thick CRCA Sheat duly compartmentalised for each control gear with louvers and air vent gasket for natuaral flow of air and suiatable provision to accomodate incomer/outgoing MCCB's/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables. Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size 'F' class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Aluminium busbar for 3 phase,440 volts, 50Hz, 4 wire system of rating 200 Amps for phases and 100 Amps for Neutral. Incoming:-MCCB 4 pole, 415 Volts, 125 Amps, breaking capacity 35 KA- 01 No. Metering Unit:- (a) R Y B Indications (LED Type) - 1 sets (b) Digital Multi function meter - 01 No (c) CT's - 800/5A, CL-1,15 VA - 1 set. Outgoing:- (a) MCCB 4 pole, 415 Volts, 63 Amps, breaking capacity 35 KA- 02 Nos. (b) MCB TPN 32 Amps "D" curve 10 KA - 2 Nos (c) Direct on line starter - 02 Nos (d) Single phase preventer - 01 Nos (e) Contactor suitable for 10 HP motor - 02 Nos (f) Provn for pressure switch -02 No
S & F fire extinguisher dry chemical powder (ABC) type (IS:15683) of capacity 4 Kg complete with installation brackets all as directed.
S & F fire extinguisher CO2 (light weight squeeze grip type) (IS:15683) of capacity 4.5 Kg complete with installation brackets all as directed.
S & F fire extinguisher Dry powder (ABC) (IS;15683) of capacity 4 kg.
S & F Fire extinguisher Mechanical Foam 9IS:15683) of capacity 9 Litres.
Each lift shall be complete with following accessories & fittings. (i) Double button with 7 segmental display at all floors. (ii) Car opening panel with micro stroke push button with 7 segment digital car position indicator, car directionb indicator (iii) Fireman's which provided at main lobby. (iv) Battery operated alarm bell and emergency lift with battery. (v) Voice Syntesizer (vi) Car Chime (vii) Provision of cross flow rectangular (low noise/mild air flow) fan-01 of approved make. (viii) S&F Decorative spot light (ix) Provn of emergency intercom system (car machine room-control system) (x) Oveload function, constant indication/buzzer. (xi) 5/15 A power socket & light point at every floor level in the hoist way. (xii) MS Ladder (xiii) 3 Phase power supply & earthing from machine room to all equipment. (xiv) 3 Phase power supply & earthing from machine room to all equipment. (xv) Emegency landing device ELD (ARD) (xvi) Extra cores in travelling cable for customer smoke detectors. (xvii) Back ground music speakers.
M& L test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw all as specified and directed.
DG SET Supply and install Static silent Disel Engine with accoustic enclosure, capable of delivering 100 Kw (125 KVA), water cooled, 415 volts (AC three phase, 4 wire system of supply) , frequency 50 Hz, at power factor 0.80 minimum. The DG set shall consists of a diesel engine coupled to a matching the alternator through flexible coupling and mounted on a common based frame and complete with control panel standardized by the manufacturer, fuel tank with mounting arrangements and with standard fuel pipes for inlet, outlet and return inlet oil arrangements, exhaust pipe, silencer and asbestrose rope protection completye and shall be suitable for conditions prevailed at Kochi. (Designed capacity of Diesel engine and alternator shall be worked out by considering all derating factors prevailed at the area to be installed) The foundation of Gen Set shall be as specified by the manufacturer and shall be mounted on a suitable Channel frame structure with anti-vibration pads and including all technical features to comply with latest CPCB guidelines and comprising of followings:-
(i) DIESEL ENGINE (Prime Mover): Diesel Engine 1500 RPM, direct injection, six cylinders, four stroke, confirming to ISO3046/BS5514, water cooled, natuarally turbo charged, capable of giving adequate BHP to drive alternator capable of delivering 128 Kw(160 KVA) at outdoor atmospheric conditions at Nedumbassery (Considering all derating factors prevailed in the area). Batteries 12/24 Volts and desired ampere hours (as per manufacturers recommendations), electric battery start, complete with fly wheel and all standard fittings and fixtures as per manufacturer and including suitable panel with techo meter, lub oil temperature, pressure gauge and frequenvy meters. The engine shall have self starter, dynamo, FIP, oil pump, fuel electric control panel with mechanical governor (ECPG) and Engine protection system (Shut down, High water temperature, low lub oil, oil pressure, over speed etc. , recommented capacity of fuel tank and first filling of fuel and lub oil and other consumables etc. (ii) ALTERNATOR: Brushless AC alternator, 3 phase, 415 Volts, 4 wire rated for output of 100 Kw (125 KVA) minimum power factort 0.80, 1500 RPM, IP 23 ptotection class enclosure, insulation class 'H', salient pole, revolving field, single bearing, automatic voltage regulator coupled through flexible coupling with and match the above engine. (iii) BASE PLATE:- Made of structural steel as per manufacturers recommended design/specifications. (iv) ACOUSTIC ENCLOSURE:- Sheet metal fabricated canopy type, silent enclosure, manufactured on CNC machines as per CPCB norms and shall be powder coated. The enclosure shall be designed for reducing the sound level to 75 DB at a distance of 1 mtr at 75% load under field condition and 70DB at 3 M from Gen Set when DG set is working at full load along with testing conformance, labeling certification etc. as laid down in GSR No. 371(E) dt 17 May 2002. (i) Foundation/Plinth/Base shall be provided as per manufacturers recommendations, however minimum 0.50 M space should be available all around the set and height of plinth shall not be less than 0.50 M. (ii) Standard Diesel Engine tank of adequate capacity for running the Gen Set continuously for 12 hours including standard pvc pipes from tank to FIP, overflow pipe from FIP to tank. (v) MISCELLANEOUS:- Tool kit, Operation and maintenance catalogue, spare parts list, overhauling manuals, guarantee cards, test certificate of Engine and alternator etc. shall be provided as per manufacturer standard practice.
(vi) AMF CONTROL PANEL:- factory made cubicle type floor mounted LT Panel board, indoor type made out of MS angle not less than 40x40x50 mmand 2 mm thick MS CRCA Sheet, front opening type, protection class IP-54, duly powder coated, copper bus bar with coloured PVC sleeves and of suitable rating for four poles mounted on suitable porcelain insulators at recommended intervals, with all standard switch gear and protection, intyernal wiring with adequate size and rating PVC insulated multistranded copper conductor cables etc. and also consisting the following: Copper busbar for 3 phase,440 volts, 50Hz, 4 wire system of rating 600 Amps for phases and 300 Amps for Neutral. Incoming:-(a) MCCB 4 pole,415 Volts, 250 Amps, breaking capacity 36 KA- 02 Nos. Metering Unit and other accessories :- (a) R Y B Indications (LED Type) - 1 set. (b) Indicator for on/off GEN/MAIN supply- 2 Nos. (c) Digital Multi function meter - 01 No. ( d) CT's - 250/5A, CL-1,15 VA - 1 set (e) 3 pole line Contactorwith AC coil, 185 Amps- 2 Nos. (f) All standard relays, circuits and protection required for automatic operation of DG set. (g) Charger for recharging the battery and armoured copper cable of suitable rating from battery charger to the engine- one job. Outgoing:- (a) MCCB 4 pole,415 Volts, 200 Amps, breaking capacity 36 KA- 02 Nos.(one spare)
M& L for earth contunity conductor of size 32x6mm GI strip all as specified and directed. (For Lifts and DG Set)
Supply and fix GI pipe light grade as cable protection laid in trench/ floor or fixed on wall etc of 40mm dia all as specified and directed
M & L Earthing complete with Galvanized steel earth plate electrode of size 600mmX600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal GL and connected to galvanized iron strip of size 32 x 6 mm size by means of bolts, nuts, check nuts and washers of galvanized iron steel all as shown in Electrical Plate No.5 connecting to earthing test point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 (using 20mm graded aggregate), common salt, charcoal, CI funnel, earth pit cover in RCC 1:2:4 type B1 (using 20mm graded aggregates), with 8mm CTD bars @ 100mm c/c in both ways, including necessary form work complete including necessry test on completion all as specified and as directed. Note : The unit rate shall also include for excavation, earth work in hard/dense soil PCC (1:3:6) type C1 pit, RCC cover slab, GI funnel with 40 mm dia watering pipe, wire mesh, 15mm dia light grade GI protection pipe for earth lead etc., complete.
M & L Earthing complete with Galvanized steel earth plate electrode of size 600mmX600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal GL and connected to galvanized earth wire 4 mm dia. by means of bolts, nuts, check nuts and washers of galvanized iron steel all as shown in Electrical Plate No.5 connecting to earthing test point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 (using 20mm graded aggregate), common salt, charcoal, CI funnel, earth pit cover in RCC 1:2:4 type B1 (using 20mm graded aggregates), with 8mm CTD bars @ 100mm c/c in both ways, including necessary form work complete including necessry test on completion all as specified and as directed. Note : The unit rate shall also include for excavation, earth work in hard/dense soil PCC (1:3:6) type C1 pit, RCC cover slab, GI funnel with 20 mm dia watering pipe, wire mesh, 15mm dia light grade GI protection pipe for earth lead etc., complete.
PILE FOUNDATION Boring Cast in situ DMC pile of 600mm dia to any depth through any type of soil/strata by DMC method using bentonite slurry including removal of bored materials outside MD land complete all as specifioed and directed. Note:- (i) The rate shall include mobilisation,erection,dismantling and demobilisation of equipment for pile boring including all labours and material. Nothing extra shall be payable for mobilisation of equipment separately. (ii) This item will be executed as per location marked in drg.
Reinforced cement concrete of grade RMC M-30 design mix as per IS – 456 with using 20mm graded stone aggregate in cast in situ bored pile of any length/any sections complete all as specified and as shown on drg as in bored pile including non destructive integrity test on all pile as per IS-14893,2001 part-IV. (Note: The unit rate quoted under this item is deemed to be inclusive of charges for non destructive integrity test)
RCC grade RMC M30 design mix as per IS–456 using 20mm graded stone aggregate in pile caps, grade beams etc complete all as specified and shown on drg. Note: Reinforcement shall be measured and paid for separately under relevant items of this Schedule.
Providing TMT bars (CRS/HCRM/CRM) in reinforcement 10mm dia and over for bored piles of any length and any dia all as shown on drgs including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/required shape complete all as specified and shown on drgs.
Ditto All as per item No 11.77 here-in-before but for pile caps complete all as specified and directed.
Providing TMT bars (CRS/HCRM/CRM) in reinforcement 5mm dia and over upto and including 12mm dia conforming to IS-1786 as in stirrups for pile caps and grade beams cut to length bent to shape required and binding with mild steel wire (annealed) not less than 0.9mm dia or welding.
Providing TMT bars (CRS/HCRM/CRM) in reinforcement 5 mm dia end over up to and including 10mm dia conforming to IS-1786 as in Helical/stirrups for piles cut to length, bent to shape required, and binding with 0.9mm dia MS annealed wire or welding .
PCC 1:4:8 type D2 using 40mm graded stone aggregate for concrete layer below pile caps and foundation complete all as specfified and as shown in drg
Formwork to sides of concrte foundation, pile caps , grade beams etc rough finished surface of concrete flat. All as specified and as directed.
Excavation over area exc 1.5m wide and not exc 1.5m in depth for foundation in soft/loose soil for pile cap/ grade beam/ tie beam
Excavation over area exc 1.5m wide and exc 1.5m but not exc 3m in depth for foundation in soft/loose soil for pile cap/ grade beams
Returning/filling in layers and ramming in layers around pile cap, grade beam etc using excavated soil incl sprading,levelling,well ramming in layers not less than 25cm thick.
Removing excavated material exc 50m n.exc 100m and depositing where directed at a level n.exc 1.5m above starting point
Testing of piles (Initial Load test for compression load, lateral load and uplift load) all as per IS 2911 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed for 600mm dia cast in situ pile. Note: Rate is inclusive for casting of 04 piles for above test. However Boring, concrete and steel shall be measured and paid under respective item
Testing of piles (Routine Load test) all as per IS for 600mm dia Cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed. Note: Only compression load Test shall be carried out for Routine load test
Excavating over area in water, liquid or mud and interrupted by tides n.exc 1.5m in depth for foundation etc, exc 10sqm on plan and getting out in soft/loose soil
Use and waste of timbering n.exc 1.5m deep as planking and strutting for excavation over area in soil for foundations tightly driven close butt jointed sheeting including packing cavities etc including wales, struts, open poling boards, in cladding use and waste of raking shores and fixing and removal
Supply, installation Organic Waste Converter fulley automatic having capacity of 150Kg/ day having internal tank made from high quality stainless steel while external panels are powder coated for enhanced product life with necessary electric control panel, cabling, necessary civil work for installing machine etc with following requirements (a) Type of Machine: Fully automatic in-vessel compositor (b)Composting method: Micro organism based organic composting (c) Type of microrganism: Heat resistant thermophilic Bacteria (d) Final output: Organic soil additive (e)Cycle time: 24 Hrs (f) Volume reduction in 24hrs : 85 - 90% (g) Internal tank: Stainless steel type (h) Main agitator shaft: Stailess steel type (i) Inpet Voltage: 415V (j) spacial features: VFD as standard across all models, touch screen standards (k) Daily waste processing: 150 Kgs (l) Rated capacity: 7KW (m) Power consumption(KWH per cycle) : 13-15 (n) Length: 1650mm (o) Width: 850mm (p) Height: 1455mm
Supply, install & commissioning of Electrically operated, fully automatic Incinerator having 10kg/hour burning capacity with horizontal/ vertical type comprising of primary, secondary chamber, designed on “controlled air” incineration principle and provided with minimum of 115mm thick refrectory and insulation bricks confirming to IS 8-1994 and IS 2042-2006 to sustain minimum temperature of 500 degree centigrade, one fully automatic pressure jet type burner for each chamber, chamber made of mild steel plate of adequate thickness (minimum 5mm thk), 3000mm high chimney, exhaust system, high pressure ventury scrubber, PLC based control panel, droplet seperator eth including all other accessories and piping, equipements and civil works required for installation of Incinerator chimney complete all as specified, including following: (a) Body made of MS steel (b) 50mm insulation (c) Loading Hull at the bottom (d) Primary and secondary chamber along with independent temprature control
SOLAR POWER PLANT Supply, installation, Testing & commissioning of roof top Solar Power Plant of 20 KWp including solar panel, solar Inverter, Module Mounting structure and comprising of following: (i) Solar PV module Pmax 380 Wp monoperc cells efficiency not less than 16.20, Voc 30 Isc 09, 03 AR coated antimony free glass material 25 years performance warranty with connecting junction box all as specified Make Havells, Lanco, adani, TATA, Topsun 1143 no (ii) Grid tied inverters 3 phase 20 KW 50 Hz having 02 separate MPP tracker with SPD glass surge protection devices having efficiency 98% graphical display.inbuilt LED interface with RS485 and compatible for online monitoring systore suitable for Ambient temperature of KOCHI, protection IP 65, overvoltage/ under voltage protection all as specified. Make-Havells, ABB, Siemens, schneider, TATA Qty -01 Each ( 10 Years warranty (iii) DC solar distribution Box to colect the DC output from Array junction Box and supply to inverter weatherproof for outdoor applications and including MCB/MCCB of proper rating depending upon the cap of the power plant complete all as specified. MAKE : HPL, Schneider, Havells (iv) AC solar distribution Box to collect the DC output from Array Junction Box and supply to inverter weatherproof for outdoor applications and including MCB MCCB of proper rating depending upon the cap of the power plant complete all spd MAKE : HPL, Schneider, Havells (v) Grid interfacing unit having MCCB cap 63 Amp 4 Pole 25 KA microprocessor based all as specified. Make- Havells/ABB/L&T/Schneider/Siemens 01 Each set. (vi) Cables as per site requirement from PV Module To LT Panel: 1 Core X 4sqmm, 1 C X 6 Sqmm solar cable, 4Core X 10 sqmm,Cu unarmored. (vii) Online monitoring system Make Havells/ Delta/ KACO or as approved.
(viii) Hot dip galvanised MS/ Aluminium mounting structure for mounting of modules /array panels et, such structure should have angle of inclination as per site conditions take max insolation, mounting structure shall be designed to withstand the speed of 150 KM per hour be designed, fasting arrangements grouting, clamping etc provided to secure the installation against Online monitoring system Make- Havells/ Delta /KACO or as approved complete all as specified Note: The mounting structure shall be as per latest IS, galvanised of the mounting structure shall be in compliance, structural material shall be corrosion resistent and electrolyticaly compatible with the materials used in the module frame, its nuts and bolts the fasteners used should be make up of mild steel. the structures shall be designed to allow easy replacement of any module PCC foundation if required deemed to be included. (ix) Meter reading instruments with suitable software of capacity 16.5 MB to record reading through optical communicatin port of any type of meter Make Secure/ HPL Havells (x) 3 phase DLMS type integrated meter with inbuilt CT & GSM Modern energy meter having LCD display, 50 Hz +/- 5%, provision of sealing on mains cover and terminal cover IP 51, tamper information, inbuilt battery back up to active its display in absence of power. optical port for local communication, Optional RS232 port on RJ-11 for remote communication, in built memory for load survey data. Class 0.5s, ( 3X 240V (P-N), -/5A) Make Secure/ HPL
Supply, installation, Testing & commissioning of roof top Solar Power Plant (Item same as Sl. No 12.93) but of 30 KWp capacity
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid