Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.8 LAccepted-AOC 72 USMAN ENCAVE SECTOR O ALIGANJ LUCKNOW 226004 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226004 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹16.9 L+₹16,943 (1.01%)Rejected-Finance NEAR AVON PUBLIC SCHOOL DABHANW POST DANDI NAINI PRAYAGRAJ 211008 | PRAYAGRAJ | PRAYAGRAJ | UTTAR PRADESH | 211008 | L2 | Rejected-Finance Not being lowest bidder | |
| 3 | L3₹18.9 L+₹2.1 L (12.6%)Rejected-Finance 301 TULSI TOWER KHADAKPADA KALYAN THANE MAHARASHTRA 421301 | THANE | MAHARASHTRA | 421301 | L3 | Rejected-Finance Not being lowest bidder |
Tender Value
Refer Docs
EMD Value
₹46,800
Closing Date
7 Aug 2021, 6:00 pmClosed
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
REPAIR/MAINT AND IMPROVEMENT OF LT DISTRIBUTION NETWORK OH LINES, UG CABLE AND CONNECTED WORKS FOR OTM ACCN OF MG ROAD AND REPAIR/MAINT OF GARDEN LIGHTS, FLOOD LIGHTS AND ALLIED WORKS FOR CENTRE INSTITUTES AREA OF EAST OF MG ROAD UNDER GE E/M LUCKNOW
2021_MES_458744_1
GE/EM/LKO/EXT(ELECT)/T-38 OF 2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Lucknow
Class E or above category b (i)
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹46,800
Yes
27 Aug 2021
10 Jul 2021
9 Aug 2021
10 Jul 2021
7 Aug 2021
26 Jul 2021
Amount
Excavation in trenches in soft/loose soil not exceeding 1.5 m wide and exceeding 1.5 m, but not exceeding 3.00 m, in depth for foundations laying of cable etc. and getting out complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, and well ramming in layer not exceeding 25 cm thick in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Removing excavated material ( soils) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by Engineer-in-Charge
Material and labour for river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete all as specified and directed by Engineer-in-Charge
M&L laying well burnt old size bricks, sub class "B" bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection complete all as specified and directed by Engineer-in-Charge
Boring / drilling (Horizontly ) manually under existing road Max 10 M in width ) suitable for passing GI tubing 40 to 100 mm bore complete all as specified and directed by Engineer-in-Charge
S&F Mild steel galvanized tubes light grade ISI marked 40mm bore laid in trenches / road crossing/ fixed to pole /walls/path/drain/floor etc complete all as specified and directed by Engineer-in-Charge
All as per item No 7 above but 50 mm size
All as per item No 7 above but 80 mm size
Supply & fixing in replacement ,Laying , jointing and testing LT under ground electric power cable crossed linked polyethylene ( XLPE) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of size 16 sqmm cross sectional area, 2 core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. with and including MS Clamps, nuts , bolts, washers and Taking out old unsv/ faulty LT under ground cable of any size and capacity and deposited the same in MES store yard complete all as specified and directed by Engineer-in-Charge
All as per item No 10 above but of size 16 Sqmm 4 core
All as per item No 10 above but of size 25 Sqmm 4 core
All as per item No 10 above but of size 35 Sqmm 3.5 core
All as per item No 10 above but of size 50 Sqmm 3.5 core
All as per item No 10 above but of size 70 Sqmm 3.5 core
All as per item No 10 above but of size 95 Sqmm 3.5 core
Laying only old serviceable LT underground cable after removing of defects any type/size in trenches / road crossing /through pipes pat drains/ducts/floors/along poles/walls/ceilings complete all as specified and directed by Engineer-in-Charge. Note - excavation and earth work will be measured and paid seprately in appropriate item.
Hiring of cable fault detector, to detect exact position of fault for XLPE /PVC LT cable, 1100 Volts grade heavy duty aluminium conductor of any size including to and fro transporting charges etc. complete all as specified and directed by Engineer-in-Charge.
Disconnecting the existing cable from Panel / Pole, preparing the end for jointing including all earth work, Supply and fixing Cable end termination heat shrinkable joint inclding sleeves suitable for LT XLPE cable of size 3.5 core 16 to 50 sq mm complete all as specified and directed by Engineer-in-Charge. Make: Denson, Mseal,cabseal
All as per item No 19 above but of size 70 to 120 sq mm
Disconnecting the existing cable from Panel / Pole, preparing the end for jointing including all earth work, Supply and fixing straight through heat shrinkable joint suitable for LT XLPE cable of size 3.5 core 16 to 50 sq mm complete all as specified and directed by Engineer-in-Charge. Make: Denson, Mseal,cabseal
All as per item No 21 above but of size 70 to 120 sq mm
S&F Aluminium conductor, steel reinforced (ACSR) of code name ferret/weasel on HT/LT pole of size as ordered including stringing and jointing for overhead line on poles including aluminium binding wire 14 SWG, jumpers, line tapes etc supplied and fixed in repairs including dismantling of old ACSR conductor from HT/LT poles complete all as specified and directed by Engineer-in-Charge.
S&F Galvanished steel wire, 4 mm dia including galvanized mil steel binding wire 1.63 mm dia or cradles, guards fabricated with galvanized steel wire 3.15 mm dia including binding with 1.63 mm dia galvanized steel wire complete all as specified and directed by Engineer-in-Charge.
S&F Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections conforming to Fe-410-S grade including necessary nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape and size as directed and including applying two coats of aluminium paint (under & finishing coats) over a coat of red oxide zinc chromate primer on exposed steel surfaces, supplied and fixed in repairs, complete all as specified and directed by Engineer-in-Charge.
S&F in repair insulator Shackle type, Porcelain vitreous , white, brown, white or green insulator including galvanised mild steel straps washers, insulator bolts, washers and nuts ; 1100 Volts working pressure, 75 mm height, 90 mm Maximum dia., with 31x3 mm galvanised steel straps and 12 mm dia. of bolts complete all as specified and directed by Engineer-in-Charge.
S&F ( in repairs) Insulator Pin type, pocrcelain , vitreous, white , brown or green, insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut , 100 mm height, 65 mm dia. For 1100 volts grade complete all as specified and directed by Engineer-in-Charge.
Re-stringing of existing loose over head line ACSR conductor/GI wire any size/type etc of existing HT/Lt pole steel and PCC including replacement of aluminium binding wire or suitable size carefully without damaging of insulator etc. complete all as specified and directed by Engineer-in-Charge.
S&F stay assembly comprising of 7/10 SWG galvanised stay stranded wire of required length fixed to pole with and including flat iron, stay clamps, bolts, nuts, galvanised stay plate 230x 230x 6mm thick, 14mm dia GI stay bow, loop insulator complete all as specified and directed by Engineer-in-Charge.
M&L for outdoor type cubical panel board made out of 3.15 mm thick CRCA sheet and inner shell made out of 1.6 mm thick CRCA sheet and MS angle section 50x50x6 mm, factory fabricated front openable double door system suitable for 3 phase 4 wire 415 volts, powder coat RAL 7035 painting having thickness 90 microns comprising of the following :- a) The TPN busbar duly plated copper busbar fitted in cascaded moulding. b) Incoming MCCB 400 Amps 36 kA, 415 volts, FP - 01 Nos c) Outgoing MCCB 160 Amps 25 kA, 415 volts, FP - 02 Nos d) Outgoing MCCB 100 Amps 25 kA, 415 volts, FP - 01 Nos e) Outgoing MCB SPN 32/40Amp Amps 25 kA, 415 volts, FP - 2 Nos e) Outgoing 3 PH Time switch32 Amp 3 Pole /230 V analog time switch - 1 Nos Voltage/Ampere/Frequency meter multi functional meter - 01 No f) LED indicator lamp RYB - 01 Set of three
M&L for out door type busbar panel board made out of 3.15 mm thick MS sheet and MS angle section 50x50x6 mm factory fabricated suitable for 3 phase 4 wire 415 Volt, 50 Hz, powder coat painted comprising of the following:- a) TPN, Aluminium bus bar 400 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. b) Incoming MCCB 200 Amps 36 KA, 415 Vots, 50 Hz, FP. – 1 No c) LED Indicator lamp RYB - 01 set of three. d) Necessary excavation, earth work, PCC lean type D2 and PCC type C2 platform complete all as required.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by mean of GI wire 4 mm dia by means of bolts, nuts check nuts and washers of GI or steel and connecting to earthing test point, main switch board, testing on completion including PCC cover and frame, PCC (1:3:6) type C-2 as in earthing pit, MS funnel with wire mesh GI pipe 20 mm dia light grade for watering and GI pipe 20 mm dia light grade for the protection of GI wire from earth pit to earth point complete including necessary excavation and earth work in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance n.exc 50 m all as specified as shown in electrical plate No 5 SSR Part-I. PCC chamber shall be constructed at least one metre away from the earth pit and GI pipe fittings for watering shall be provided up to chamber and cost of the same is deemed to be included in the rate of earthing.
All as per item No 32 above but 32X6 mm strip type
Supply and fixing in repairs wall mounted bus -bar three ph, 8 way , 415 Volts with 4 nos Aluminium Bus bar 200 Amp in sheet metal enclosere of 1.6 mm thick MS sheet with powder coat painted including connecting with existing system and cabling network including making good disturbed surfaces complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of LEDstreet light fitting with mandatory driver set having pressure die cast aluminium body and lenses suitable for 60 watt confirming to IP 66 and IK 07 protection having company LOGO ingraved complete lumes high power LED with lenses Lumen efficacy of LED not less than 100 lumen per watt system,efficency power factor >0.95, THD<10% at Full load CRI> 70%, every life class 50000 hrs at the L70,poted driver set , Phase to phase protection at 415 Volts , suitable for pole mounting bracket 40 mm. all releven documents related to luminaries and driver needed to submit for approval complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of LEDstreet light fitting with mandatory driver set having pressure die cast aluminium body and lenses suitable for 45 watt confirming to IP 66 and IK 07 protection having company LOGO ingraved complete lumes high power LED with lenses Lumen efficacy of LED not less than 100 lumen per watt system,efficency power factor >0.95, THD<10% at Full load CRI> 70%, every life class 50000 hrs at the L70,poted driver set , Phase to phase protection at 415 Volts , suitable for pole mounting bracket 40 mm. all releven documents related to luminaries and driver needed to submit for approval complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of LED flood light fitting with mandatory driver set having pressure die cast aluminium body (LM 6 alloy) and lenles suitable for 50 watt IP 65 and IK 07 protection having company LOGO ingraved complete in respect with system lumes high power LED complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of LED flood light fitting with mandatory driver set having pressure die cast aluminium body (LM 6 alloy) and lenles suitable for 120 watt IP 65 and IK 07 protection having company LOGO ingraved complete in respect with system lumes high power LED complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of LED flood light fitting with mandatory driver set having pressure die cast aluminium body (LM 6 alloy) and lenles suitable for 200 watt IP 65 and IK 07 protection having company LOGO ingraved complete in respect with system lumes high power LED complete all as specified and directed by Engineer-in-Charge.
S&F Post top lantern Aluminium sheet spun canopy thick imported acr sheet molded body finished B2 ABS Holder Make as per Mepo cat Pt No PTL 15 or as equvalent given in Annexture
S&F LED 15 Watt New Generation Post top energy saving enviornmental friendly , long life aesthetically designed with symmentrical light distribution spun Aluminium landscape luminaries omplete all as specified and directed by Engineer-in-Charge.
Supply & fixing of automatic street light timer panel 12 KW /40 Amp switch using Infrared Sensor based for automatic switching of street lights based on LUX level of natural light. Required illuminance for switching ON is < 30 Lux and for switching OFF > 10 Lux level. The sensor (nature switch) alongwith suitable power contactors, Input (supply) MCB and output (load) MCB(s), support terminals should be enclosed in pole/ wall mountable enclosure made of rust proof, electric shock proof, termite proof and FR graded SMC junction box conforming to IP-54 degree of ingress three phase 8 KW lightening load capacity including mounting bracket, cable glands, openable doors with lock complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement Contactor TP 32 Amp 1NO+1NC,415 V complete all as specified and directed by Engineer-in-Charge. Make: Havells,Legrand,Indoasian
Supply & fixing in replacement Digital Time switch in existing panel Prigrammable every 1 min with backup of 6 yrs,28 memory location, current cap 16 Amp with 1 changeover (1CO) complete all as specified and directed by Engineer-in-Charge.
S&F MS Junction Box made of 1.6 mm thick MS sheet of size 300mmx200mmx150mm complete with front openable hinged cover and locking arrangements with 4 Nos aluminium bas bar 100 Amps, mounted on porcelin insulator including M&L for MCB SP 10-1No, fixed on box in Din rail complete with electrical connection fixed to pole with suitable size FI clamp nut bolts and washer including duly painted with powder coated paint complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement GI brackets made of 32/40 mm nominal bore GI pipe medium grade of required length not less than 1.5 M long, mounting brackets made out of Mild steel FI 40x6 mm of required shape ( two Nos) duly fitted with Mild steel nuts, bolts and washers and painting with two coats of synthetic enamelled paint over one coat of red oxide Zn chrome primer and fixed to pole / walls etc complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing 6 Sqmm x3 core nominal cross sectional area multistranded aluminium conductor cable 100 Rm long Roll, over all PVC sheathed, 1100 Volts grade heavy duty cable PVC insulated and PVC sheathed complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing 10 Sqmm x3 core nominal cross sectional area multistranded aluminium conductor cable, 100 Rm long Roll over all PVC sheathed, 1100 Volts grade heavy duty cable PVC insulated and PVC sheathed complete all as specified and directed by Engineer-in-Charge.
Supplying, transporting, erecting Steel tubular swaged poles type 410 SP-31 ( 9.0 metres long) complete with cast iron base plate, finial, taper plug, bolts, nuts and screws as specified, including necessary excavation and earth work , PCC 1:4:8 type D2 in foundations below pole, PCC 1:3:6 type C2 around poles and PCC 1:3:6 type C1 as in plinth block , disposal of surplus soil to a distance not exceeding 50 m and depositing where directed, painting steel tubular poles exposed surafces with Aluminium paint two coats over one coat of red oxide primer and providing 300 mm wide bands (3 bands/ straps with synthetic enamel paint and 2 bands with Black bituminous paint ) from plinth block and numbering of poles , painting embedded portion of poles with one coat of bituminous paint complete all as specified and directed by Engineer-in-Charge.
Preparation of old painted surfaces and painting of LT steel tubular pole 9 mtrs long from bottam to top with aluminium paint and painting to bottam up to 1.5 mtr height from top of PCC coping with sysnthetic enamel paint 2 coats in black and Yellow/white alternate strip including numbering in 8 cm height of number with white paint both paint aluminium /synthetic duly approved by engineer –in-Charge and complete all as specified and directed by Engineer-in-Charge.
Trimming/pruning of the tree branches coming cross electric power head line LT OH Line cleaning the span and making the free from touching the tree branches complete all as specified and directed by Engineer-in-Charge.
NEXT POWER ENTERPRISES
Diamond Electric Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .