Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 CrAccepted-AOC | ₹5.0 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹5.2 Cr+₹18.6 L (3.75%)Rejected-Finance 6 NEW SADGURU NANIK INDUSTRIAL ESTATE OFF WESTERN EXPRESS HIGHWAY GOREGAON E MUMBAI 400063 INDIA | MUMBAI SUBURBAN | MAHARASHTRA | 400063 | ₹5.2 Cr+₹18.6 L (3.75%) | L2 | Rejected-Finance L2 |
| 3 | L3₹5.3 Cr+₹30.7 L (6.18%)Rejected-Finance CHENNAI | CHENNAI | TAMIL NADU | 600001 | ₹5.3 Cr+₹30.7 L (6.18%) | L3 | Rejected-Finance L3 |
| 4 | L4₹5.8 Cr+₹79.8 L (16.0%)Rejected-Finance 201 PLOT NO 32 SHALAKA BLDG TPS II JUHU ROAD SANTACRUZ WEST MUMBAI SUBURBAN MAHARASHTRA 400054 | MUMBAI SUBURBAN | MAHARASHTRA | 400054 | ₹5.8 Cr+₹79.8 L (16.0%) | L4 | Rejected-Finance L4 |
Tender Value
Refer Docs
EMD Value
₹14.0 L
Closing Date
18 Dec 2020, 5:00 pmClosed
AGM (E-E)-II
Airports Authority of India, Southern Region, Operational Offices, Chennai Airport, Chennai 600 027
FACILITY MANAGEMENT CONTRACT OF E AND M INSTALLATIONS AT AAI RHQ SR CHENNAI AIRPORT
2020_AAI_62661_1
AAI/RHQ-SR/E-E/FMC/2020
Open Tender
Electrical Works
Item Rate
730 days
Chennai
As per NIT Criteria
18 documents required · 18 mandatory
₹1,770
₹14.0 L
Yes
18 Jan 2021
26 Nov 2020
23 Dec 2020
26 Nov 2020
18 Dec 2020
26 Nov 2020
26 Nov 2020 - 17 Dec 2020
SH I: Monitoring and Maintenance of E & M Installations
Monitoring and Maintenance of Utility Services at ATS Complex Power House Cum Sub-Station comprising of 11 KV VCB Panels (05 Nos.), 2 Nos. of 2000 KVA 11 KV/433 V Transformers, 2 Nos. of 750 KVA LT DG Sets, Bus Ducts, LT Panels, Capacitor Panels, Battery Banks, HT/LT Cabling, associated Earthing System of Utilities etc., (As per Annexure 'A1' - List of Inventories) for round the Clock 24X7 Basis (Three Shift Basis - 8 Hours For One Shift), Monitoring, Control and General Maintenance for 100% Serviceability including Co-ordination with AAI Metro Chennai Airport Intake and KDT Substations and i/c providing consumable material like cotton waste, oil, grease & other sundry material required for cleaning etc., attending minor faults of Equipments/Repairs/Replacement of defective components with AAI Supplied New Components, ensuring 100% Serviceability/satisfactory working condition of the Systems, Routine and General Preventive Maintenance on Daily/Weekly/Monthly/Quarterly/Half Yearly/Yearly Basis as per Standard Manufacturers' Practices and as per Techno Commercial Specifications (TCS), Maintenance of Records and Log Books and reporting as and when required, complete Upkeeping of the Installations etc., on all days including Sundays & Holidays as specified and as directed by Engineer-In-Charge as required.
Monitoring and Maintenance of Internal and External Electrical Services at ATS Complex including Ancillary Buildings at ATS Complex comprising of Light Fittings, Power Points, Circuit/Submain Wiring, DBs, LT Panels, Aviation Obstruction Lights, Lightning Arrestors, Street Light Poles/External Lights, Signage etc., at ATS Complex (As per Annexure 'A2' - List of Inventories) for round the Clock 24X7 Basis (Three Shift Basis - 8 Hours For One Shift), Monitoring, Control and General Maintenance for 100% Serviceability including Co-ordination with ATS Substation and i/c providing consumable material like cotton waste, oil, grease & other sundry material required for cleaning etc., attending minor faults of Equipments/ Repairs/ Replacement of defective components with AAI Supplied New Components, ensuring 100% Serviceability/satisfactory working condition of the Systems, Routine and General Preventive Maintenance on Daily/Weekly/Monthly/Quarterly/Half Yearly/Yearly Basis as per Standard Manufacturers' Practices and as per Techno Commercial Specifications (TCS), Maintenance of Records and Log Books and reporting as and when required, complete Upkeeping of the Installations etc., on all days including Sundays & Holidays as specified and as directed by Engineer-In-Charge as required.
Monitoring and Maintenance of Water Supply Installations at ATS Complex comprising of Water Supply Pumps, RO Plant, LT Panels etc., at Pump House of ATS Complex, Including Operation of Elevators at ATS Complex as per the Direction of Engineer-In-Charge (As per Annexure 'A3' - List of Inventories) for round the Clock 24X7 Basis (Three Shift Basis - 8 Hours For One Shift), Monitoring, Control and General Maintenance for 100% Serviceability including Co-ordination with ATS Switch Room and i/c providing consumable material like cotton waste, oil, grease & other sundry material required for cleaning etc., attending minor faults of Equipments/Repairs/Replacement of defective components with AAI Supplied New Components, ensuring 100% Serviceability/satisfactory working condition of the Systems, Routine and General Preventive Maintenance on Daily/Weekly/Monthly/Quarterly/Half Yearly/Yearly Basis as per Standard Manufacturers' Practices and as per Techno Commercial Specifications (TCS), Maintenance of Records and Log Books and reporting as and when required, complete Upkeeping of the Installations etc., on all days including Sundays & Holidays as specified and as directed by Engineer-In-Charge as required.
Monitoring and Maintenance of Utility Services/Internal and External Electrical Services at at AAI Operational Offices comprising of Light Fittings, Power Points, Circuit/Submain Wiring, DBs, LT Panels, Aviation Obstruction Lights, Lightning Arrestors, Street Light Poles/External Lights, Signage etc., at RHQ SR Operational Offices (As per Annexure 'A4' - List of Inventories) on General Duty Basis (8 Hours of Duty of Time as decided by Engineer-In-Charge), Monitoring, Control and General Maintenance for 100% Serviceability including Co-ordination with Chennai Airport Admin Power House Cum Substation and i/c providing consumable material like cotton waste, oil, grease & other sundry material required for cleaning etc., attending minor faults of Equipments/ Repairs/ Replacement of defective components with AAI Supplied New Components, ensuring 100% Serviceability/ satisfactory working condition of the Systems, Routine and General Preventive Maintenance on Daily/ Weekly/ Monthly/ Quarterly/ Half Yearly/ Yearly Basis as per Standard Manufacturers' Practices and as per Techno Commercial Specifications (TCS), Maintenance of Records and Log Books and reporting as and when required, complete Upkeeping of the Installations etc., on all days as specified and as directed by Engineer-In-Charge as required.
Monitoring and Maintenance of Utility Services/Internal and External Electrical Services at AAI RHQ SR Residential Colony comprising of 11 KV VCB Panels (03 Nos.), 2 Nos. of 11 KV/433 Volt Transformers (500KVA and 315 KVA), 2 Nos. of 125 KVA LT DG Sets, LT Panels, associated Earthing System of Utilities, Light Fittings, Power Points, Circuit/Submain Wiring, DBs, LT Panels, Street Light Poles/External Lights, Signage etc., at Quarters (As per Annexure 'A5' - List of Inventories) for round the Clock 24X7 Basis (Three Shift Basis - 8 Hours For One Shift), Monitoring, Control and General Maintenance for 100% Serviceability including Co-ordination with TANGEDCO and i/c providing consumable material like cotton waste, oil, grease & other sundry material required for cleaning etc., attending minor faults of Equipments/Repairs/Replacement of defective components with AAI Supplied New Components, ensuring 100% Serviceability/satisfactory working condition of the Systems, Routine and General Preventive Maintenance on Daily/Weekly/Monthly/Quarterly/Half Yearly/Yearly Basis as per Standard Manufacturers' Practices and as per Techno Commercial Specifications (TCS), Maintenance of Records and Log Books and reporting as and when required, complete Upkeeping of the Installations, on all days including Sundays & Holidays as specified and as directed by Engineer-In-Charge as required.
Monitoring and Maintenance of Water Supply/Sewage Treatment Installations at AAI RHQ SR Residential Colony comprising of Water Supply Installations (Borewell Submersible Pumps/Open Well Submersible Pumps/Jet Pumps) and Sewage Treatment Installations (Pumps/Aerator/Filters/LT Panels) etc., (As per Annexure 'A6' - List of Inventories) for round the Clock 24X7 Basis (Three Shift Basis - 8 Hours For One Shift), Monitoring, Control and General Maintenance for 100% Serviceability including providing consumable material like cotton waste, oil, grease & other sundry material required for cleaning etc., attending minor faults of Equipments/Repairs/Replacement of defective components with AAI Supplied New Components, ensuring 100% Serviceability/satisfactory working condition of the Systems, Routine and General Preventive Maintenance on Daily/Weekly/Monthly/Quarterly/Half Yearly/Yearly Basis as per Standard Manufacturers' Practices and as per Techno Commercial Specifications (TCS), Maintenance of Records and Log Books and reporting as and when required, complete Upkeeping of the Installations etc., on all days including Sundays & Holidays as specified and as directed by Engineer-In-Charge as required.
Monitoring and Maintenance of Utility Services/Internal and External Electrical Services at MSSR Porur Power House Cum Sub-Station/MSSR Building comprising of 11 KV VCB Panels (03 Nos.), 2 Nos. of 250 KVA 11 KV/433 Volt Transformers, 2 Nos. of 160 KVA LT DG Sets, LT Panels, associated Earthing System of Utilities, Light Fittings, Power Points, Circuit/Submain Wiring, DBs, LT Panels, Aviation Obstruction Lights, Lightning Arrestors, Street Light Poles/External Lights, Signage etc., Including Operation of Elevator, AC Units, Water Supply Installations and Water Softening/Treatment Units (As per Annexure 'A7' - List of Inventories) for round the Clock 24X7 Basis (Three Shift Basis - 8 Hours For One Shift), Monitoring, Control and General Maintenance for 100% Serviceability including Co-ordination with TANGEDCO and i/c providing consumable material like cotton waste, oil, grease & other sundry material required for cleaning etc., attending minor faults of Equipments/ Repairs/ Replacement of defective components with AAI Supplied New Components, ensuring 100% Serviceability/ satisfactory working condition of the Systems, Routine and General Preventive Maintenance on Daily/ Weekly/ Monthly/ Quarterly/ Half Yearly/ Yearly Basis as per Standard Manufacturers' Practices and as per Techno Commercial Specifications (TCS), Maintenance of Records and Log Books and reporting as and when required, complete Upkeeping of the Installations, on all days including Sundays & Holidays as specified and as directed by Engineer-In-Charge as required.
Monitoring and Maintenance of Utility Services/Internal and External Electrical Services at WT Station Mugalivakkam Power House Cum Sub-Station comprising of 11 KV VCB Panels (03 Nos.), 2 Nos. of 250 KVA 11 KV/433 V Transformers, 2 Nos. of 62.5 KVA LT DG Sets, LT Panels, associated Earthing System of Utilities, Light Fittings, Power Points, Circuit/Submain Wiring, DBs, LT Panels, Aviation Obstruction Lights, Lightning Arrestors, Street Light Poles/External Lights, Signage etc., Including Operation of AC Units, Water Supply Installations and Water Softening/Treatment Units (As per Annexure 'A8' - List of Inventories) for round the Clock 24X7 Basis (Three Shift Basis - 8 Hours For One Shift), Monitoring, Control and General Maintenance for 100% Serviceability including Co-ordination with TANGEDCO and i/c providing consumable material like cotton waste, oil, grease & other sundry material required for cleaning etc., attending minor faults of Equipments/Repairs/Replacement of defective components with AAI Supplied New Components, ensuring 100% Serviceability/satisfactory working condition of the Systems, Routine and General Preventive Maintenance on Daily/Weekly/Monthly/Quarterly/Half Yearly/Yearly Basis as per Standard Manufacturers' Practices and as per Techno Commercial Specifications (TCS), Maintenance of Records and Log Books and reporting as and when required, complete Upkeeping of the Installations, on all days including Sundays & Holidays as specified and as directed by Engineer-In-Charge as required.
Monitoring and Maintenance of Utility Services/Internal and External Electrical Services at Outer Marker comprising of 1 No. of 15 KVA LT DG Set, LT Panel, associated Earthing System of Utilities, Light Fittings, Power Points, Circuit/Submain Wiring, DBs, LT Panels, Aviation Obstruction Lights, Lightning Arrestors, Street Light Poles/External Lights, Signage etc., Including Operation of AC Units, Water Supply Installations and Water Softening/Treatment Units (As per Annexure 'A9' - List of Inventories) for round the Clock 24X7 Basis (Three Shift Basis - 8 Hours For One Shift), Monitoring, Control and General Maintenance for 100% Serviceability including Co-ordination with TANGEDCO and i/c providing consumable material like cotton waste, oil, grease & other sundry material required for cleaning etc., attending minor faults of Equipments/Repairs/Replacement of defective components with AAI Supplied New Components, ensuring 100% Serviceability/satisfactory working condition of the Systems, Routine and General Preventive Maintenance on Daily/Weekly/Monthly/Quarterly/Half Yearly/Yearly Basis as per Standard Manufacturers' Practices and as per Techno Commercial Specifications (TCS), Maintenance of Records and Log Books and reporting as and when required, complete Upkeeping of the Installations, on all days including Sundays & Holidays as specified and as directed by Engineer-In-Charge as required.
Monitoring and Maintenance of Utility Services/Internal and External Electrical Services at ASR/MSSR Power House Cum Sub-Station/MSSR Building in Operational Area of Chennai Airport comprising of 11 KV VCB Panels (07 Nos.), 2 Nos. of 500 KVA 11 KV/433 Volt Transformers, 2 Nos. of 320 KVA LT DG Sets, LT Panels, associated Earthing System of Utilities, Light Fittings, Power Points, Circuit/Submain Wiring, DBs, LT Panels, Aviation Obstruction Lights, Lightning Arrestors, Street Light Poles/External Lights, Signage etc., Including Operation of AC Units, Water Supply Installations and Water Softening/Treatment Units (As per Annexure 'A10' - List of Inventories) for round the Clock 24X7 Basis (Three Shift Basis - 8 Hours For One Shift), Monitoring, Control and General Maintenance for 100% Serviceability including Co-ordination with ATS SS/Old Airport Power House/Remote Bays Power House and i/c providing consumable material like cotton waste, oil, grease & other sundry material required for cleaning etc., attending minor faults of Equipments/Repairs/Replacement of defective components with AAI Supplied New Components, ensuring 100% Serviceability/satisfactory working condition of the Systems, Routine and General Preventive Maintenance on Daily/Weekly/Monthly/Quarterly/ Half Yearly/Yearly Basis as per Standard Manufacturers' Practices and as per Techno Commercial Specifications (TCS), Maintenance of Records and Log Books and reporting as and when required, complete Upkeeping of the Installations, on all days including Sundays & Holidays as specified and as directed by Engineer-In-Charge as required. complete Upkeeping of the Installations, on all days including Sundays & Holidays as specified and as directed by Engineer-In-Charge as required.
Providing Supervisory Engineering Services for All E&M Installations Covering Item 1 to 10 as above including Monitoring/Control/Co-ordination/Maintenance of Utility Services/Internal and External Electrical Services for round the Clock 24X7 Basis (Three Shift Basis - 8 Hours For One Shift)/General Duty (Timing as decided by EIC) , Maintenance of Records and Log Books and reporting as and when required, on all days as specified and as directed by Engineer-In-Charge as required.
SH: II A ISC of HT Panels and LT ACBs of Power Supply Installations.
Overhauling and Servicing of (400 - 1250) Amp 11 KV HT VCBs by Deploying Authorised Service Personnel of Manufacturer/Service Dealer/ Specialised Agency experienced in similar nature of work, provided at Various Power Houses/ Substations including drawing out of the VCB, opening the same, Inspection, Servicing, Cleaning of Contact Surfaces, Overhauling of Operating Mechanism, Lubrication of Moving Parts, Cleaning of CTs, PTs, Busbars and Chambers, Checking of Busbars and bus links, Replacement of Gasket of Panel, Checking of Electrical and Mechanical Operation, measuring of Contact Resistance, Checking of IR values, Testing of ON OFF Time, replacement of minor defective spares supplied by AAI (excluding supply of spares), Testing and Commissioning etc., as required. ISC of VCBs [CG Make VCBs-3 Nos. At NAD Colony SS + JYOTHI Make-3 Nos. At MSSR Porur SS+ KIRLOSKAR Make-06 Nos. at ATS Complext SS + CG make - 7 Nos at ELDIS Radar]
First Year
Second year
Overhauling and Servicing of Trip Circuit Battery Charging Unit by Deploying Authorised Service Personnel of Manufacturer/ Service Dealer/ Specialised agency experienced in similar nature of work, provided at Various Power Houses/ Substations including Inspection, Servicing, Cleaning of Charger, Checking of Charger Circuit (Control and Power Circuit) including Instruments/ Relays/ Meters/ Transformers/ Rectifiers/ Filters, attending faults, Replacement of Defective Components (Excluding Cost of Spares), Checking of Batteries, Terminals, Checking of Operation, Testing and Commissioning etc., as required.
First Year
Second Year
Inspection/Overhauling/Servicing of ACBs of L&T/ GE/ C&S Make of Various Capacities provided in the various LT Panels at Various Power Houses/ SSs by Deploying Authorised Service Personnel of Manufacturer/ Service Dealer/ Specialised Agencies experienced in Servicing of ACBs including cleaning of ACBs, opening the same, inspection, servicing, cleaning of contact surfaces, arc chutes, overhauling of operating mechanism, lubrication of moving parts, Checking of UV Coils, Trip Circuits, Checking of Control Circuits, replacement of minor defective spares supplied by AAI (excluding supply of spares), testing and commissioning etc., as required.
First Year
Second Year
Calibration of Releases provided in various ACBs in various LT Panels, Testing of Tripping, Timing, etc., i/c adjustment of Settings if required at site by Secondary Injection Test as required.
First Year
Second Year
SH: II B Calibration of Relays and Testing of CTs.
Calibration of Relays [(Electro-Mechanical/ Static/ Digital/ Microprocessor Based Relays)-(O/C and E/F)/] provided in various HV/LV Panels, Testing of Insulation Values, Pick-up Value, Timing, Burden, etc., i/c adjustment of Settings if required at site, Relay Co-ordination with immediate Up and Down Circuit etc., as required, conforming to IS 9124 - 1979 by Secondary Injection Test as required.
First Year
Second Year
Calibration of Auxillary Relays/Master Trip Relay provided in various HV/LV Panels, Testing of Insulation values, Pick-up Value, Drop Off, Burden etc., as required, conforming to IS 9124 - 1979 by Secondary Injection Test as required.
First Year
Second Year
Testing of 11 KV CTs (3 Nos. of Current Rating of Upto 400 Amps associated with Relays (OC/EF/Master) provided in various HV Panels, Tesing of Polarity, Ratio, Insulation values, Testing of Ammeter connected in the Panel, Marking of available CT Ratio, Checking of Trip Circuit and Breaker Operation/Tripping etc., as required, conforming to IS 9124 - 1979 by Primary Injection Test (Maximum upto 50% of Rating of CTs-Testing at 25% and 50% of Original Rating) as required.
First Year
Second Year
SH II C : Filtration of Transformer Oil and Servicing of OLTCs.
Filtration of Transformer Oil of following Equipments conforming to IS 6792/72 and IS 1866 as required with up to date amendments, including transporting Filtration Plant and BDV Test Kit, Replacement of Silica Gel, Acidity Testing of Oil at Chemical Testing Lab, Submission of Reports, Checking of Cable Tightness, Gasketting of Cable End Boxes etc. as required.
MSSR PORUR SUBSTATION 250 KVA 11KV/433V Transformer Approx Oil Qty in ltrs 370.00
First Year
Second Year
ATS COMPLEX SUBSTATION 2 MVA 11KV/433V Transformer Approx Oil Qty in ltrs 2130.00
First Year
Second Year
NAD RESIDENTIAL COLONY SUSBSTATION 500KVA 11KV/433V Transformer Approx Oil Qty in ltrs 540.00
First Year
Second Year
NAD RESIDENTIAL COLONY SUSBSTATION 315 KVA 11KV/433V Transformer Approx Oil Qty in ltrs 350.00
First Year
Second Year
Supply of Transformer Oil conforming to IS 335/1983 for topping up of oil for Transformer during filtration of Oil and for replacement of Oil for the Transformers.
First Year
Second Year
ELDIS RADAR SUSBSTATION 400KVA 11KV/433V Transformer
First Year
Second Year
Testing of Power Transformer of following rating 11 / 0.433 KV i/c testing of Insulation resistance, Magnetising current, winding resistance with mico-Ohm meter and Magnetic balance, etc., as required.
MSSR PORUR SUBSTATION 250 KVA 11KV/433V Transformer
First Year
Second Year
ATS COMPLEX SUBSTATION 2 MVA 11KV/433V Transformer
First Year
Second Year
NAD RESIDENTIAL COLONY SUSBSTATION 500KVA 11KV/433V Transformer
First Year
Second Year
NAD RESIDENTIAL COLONY SUSBSTATION 315 KVA 11KV/433V Transformer
First Year
Second Year
ELDIS RADAR SUSBSTATION 400KVA 11KV/433V Transformer
First Year
Second Year
Providing and Fixing Glass Cover, Rubber Beading for Marshelling Boxes of Transformers as required.
First Year
Second Year
Servicing of Voltamp Make OLTC available in 2 MVA, 11 KV/433 V Transformer at ATS Complex Power House by OEM/OEMs' Authorised Service Dealer completely including removing of Oil from the tank, flushing out of deposits, cleaning of contacts, checking and tightening of contacts and fasteners, checking of transient resistance, topping up of New oil/Filtration of Oil through oil Filtration machine (excluding supply of oil), lubricating the mechanism, replacing top cover gasket, Checking of RTCC Panel, checking of operation electrically and manually (local & remote operation), replacement of minor defective spares supplied by AAI (excluding supply of spares), etc., as required.
First Year
Second Year
SH II D : CMC of Active Harmonic Filter
Comprehensive Annual Maintenance Contract of Active Harmonic Filters of Capapcity 35A including replacement of all spares, consumables, manpower required for trouble shooting arrangement of all tools and plants, routine preventive and breakdown maintenance etc. as required as per good Engineering practice for maintaining the system in operational and serviceable state. .
MSSR Porur- 1No
First Year
Second Year
SH-III (A): Servicing of E & M Installations.
Lifting of Submersible Pumps of various capacities from the existing Bore Well/Well and reinstalling the Submersible Pumps in the existing bore well / well (After servicing/ repairing both are exclusive) complete as required.
Rewinding of 1 No. 5HP / 7.5 HP borewell pumpset, including replacement of damaged parts such as inlet base, bushes, thrust bearing set, neck rings etc, including reassembling, painting, testing, transpotation etc as required.
Rewinding of 1 No. 10 HP borewell pumpset, including replacement of damaged parts such as inlet base, bushes, thrust bearing set, neck rings etc, including reassembling, painting, testing, transpotation etc as required.
Lifting of 3 HP/5 HP Sewage Submersible pump in the existing raw sewage sump and servicing of shaft, replacement of mechanical seal & bearing and reinstallation of servicable Sewage Submersible pump in the sump etc., as required.
Rewinding of 5 HP Foot mount motor including dismantling and reinstallation etc as required.
Servicing of 7.5 HP Pressure Filter pump including repalcement of damaged parts like Pump shaft, Bearing, Oil seal, Mechanical seal, Screw & Gasket etc., and reinstallation of servicable pump as required.
Comprehensive Annual Maintenance Contract of 2 Nos 400 LPH RO Plant inclusive of monthly servicing, attending faults/ breakdowns and taking rectification action as and when required, maintaining the serviceability / satisfactory working condition of the plants, adding antiscalant chemicals to avoid scaling of pipelines as and when required, replacement of prefilter cattridge once in three months, including sand filter ,maintaining the required taste and required TDS level (30 to 120) including providing test reports for the same, etc as required. (excluding Membrane).
Comprehensivel Maintenance Contract of 10 LPH RO water purifier Ozone make inclusive of monthly servicing, attending faults/ breakdowns and taking rectification action as and when required, maintaining the serviceability / satisfactory working condition of the plant,including replacing of One set of Membrane and Filters and including providing test reports for the same, etc complete as required.
Supply of RO membrane for RO plant of 400LPH capacity (Make CSM , model RE 4040 -BN or its equivalent).
Annual Maintenance Contract of Fire Hydrant System consisting of Jockey/ Electrical/ Diesel pumps with associated Electro Meachanical installations at ATS Complex, carrying out regular monthly checks required, attending breakdowns as and when required, carrying out B checks for Engines excluding supply of B check spares and other spares as required.
Repair & Rewinding of 1400/1200 mm Sweep Ceiling fan i/c replacement of spares as required.
Repair & Rewinding of all capacities of exhaust fan i/c replacement of spares as required.
Maintenance of Conventional/ Microprocessor Based Fire Alarm System [FAS] including all Associated Accessories and Auto Dialer of all FAS Types/ Models/ Make installed at following Locations including Repairs and Maintenance, attending Faults of Systems, Replacement of Defective Components with AAI Supplied New Components, ensuring 100% Serviceability/ Satisfactory Working Condition of FAS, Routine and General Preventive Maintenance on Monthly/ Quarterly/ Half yearly/ Yearly Basis as per Standard Manufacturers' Practices, Break-Down Maintenance, Maintenance of Records/Service Reports and Reporting as and when required, complete Up-keeping of the Installations [FAS], as specified and as directed by Engineer-In-Charge as required.
Localizer 07 (Two Zone - Make : Ravel)
Localizer 25 (Two Zone - Make : Ravel)
GLIDE PATH 07 (Two Zone - Make : Ravel)
GLIDE PATH 25 (Two Zone - Make : Ravel)
GBAS (Two Zone - Make Morley IAS)
Remote Receiver Station (Four Zone - Make : Ravel)
Com Stores (AAI-SR Colony)-(Eight Zone - Make : Morlay IAS)
Maintenance of Addressable Type Fire Alarm System [FAS] including all Associated Accessories and Auto Dialer of all FAS Types/Models/Make installed at following Locations including Repairs and Maintenance, attending Faults of Systems, Replacement of Defective Components with AAI Supplied New Components, ensuring 100% Serviceability/Satisfactory Working Condition of FAS, Routine and General Preventive Maintenance on Monthly/Quarterly/Half yearly/Yearly Basis as per Standard Manufacturers' Practices, Break-Down Maintenance, Maintenance of Records/Service Reports and Reporting as and when required, complete Up-keeping of the Installations [FAS], as specified and as directed by Engineer-In-Charge as required.
ATS Complex (8 Loop, Make: Edward)
Operational Offices Admin Budilding(NAD) ( Four Loop - Make: EDWARD )
DVOR 07 (Single Loop - Make : EDWARD)
DVOR 12 (Single Loop - Make : EDWARD)
New ASR/MSSR (Single Loop - Make : MORLAY)
MSSR Porur (Two Loop - Make : EDWARD)
WT STATION (Single Loop - Make : EDWARD)
SH III(B) : AMC of Automatic Sliding Door
Annual Maintenanace contract of 2Nos Automatic Sliding Doors including Routine/preventive quarterly maintenance, attending Break down Maintenanace , attending Minor & Major repair works,ensuring 100% serviceability and satisfactory working conditionas per standard manufacturers practices and documentation of service/ complaints/PMI Checks etc as required ( spares excluded).
First year (2020-21)
Second Year (2021-22)
SH-IV: Annual Rate Contract for Internal Electrical works
Wiring for light point/ fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Group B
Group C
Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Group B
Group C
Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required.
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing following size/ modules, PVC box alongwith modular base & cover plate for modular switches in recess etc as required
3 Module
6 Module
8 Module
12 Module
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
2 X 1.5 sq.mm + 1 X 1.5 sq.mm earth wire
2 X 2.5 sq.mm + 1 X 2.5 sq.mm earth wire
2 X 4 sq.mm + 1 X 4 sq.mm earth wire
2 X 6 sq.mm + 1 X 6 sq.mm earth wire
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing of following sizes of medium class PVC Casing 'N' Caping along with accessories in surface as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel / PVC conduit as required.
3 x 1.5 sq. mm
3 x 2.5 sq. mm
3 x 4 sq. mm
Supply and fixing rotary stepped type electronic fan regulator (1 module) on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required
5/6 Amps switch
15/16 Amps switch
3 pin 5/6 Amps socket outlet
6 pin 15/16 Amps socket outlet
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted,inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required • (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
TPN 8 Way (8+24) MCB DB double door
TPN 4 (8+12) Way MCB DB double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator)
SPN 8 Way MCB DB double door
SPN 6 Way MCB DB double door
SPN 4 Way MCB DB double door
Supplying and fixing following rating, 415 volts, Four pole MCB, C curve in the existing MCB DB complete with connections, testing and commissioning etc., as required
40A FP MCB
63A FP MCB
Supplying and fixing following rating, 415 volts, Four pole RCCB, C curve in the existing MCB DB complete with connections, testing and commissioning etc., as required
40A FP RCCB, 300mA
63A FP RCCB, 300 mA
40A FP RCCB, 100mA
63A FP RCCB, 100 mA
Supplying and fixing of 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing of 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
Supplying and fixing of 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole andearth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steelenclosure, on surface or in recess, with chained metal cover for the socket out letand complete with connections, testing and commissioning etc. as required.
Supplying and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4 pole andearth, metal enclosed plug top alongwith 20 A "C" curve, TPMCB, in sheet steelenclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Providing illumination with standard couloured serial lamps sets for one day on different occassions (Containing minimum 20 Nos of lamps per set) on the ADMN building,ATS and other ancillary building and trees as directed by the Engineer-In - Charge.
Providing illumination with multicolour LED colour wash flood light for one day on different occassions with required cables and all accessories to illuminate the fasia of the buildings as directed by the Engineer -In- Charge.
SH-V: Annual Rate Contract for External Electrical Works
SH-V-A : Cabling Works
Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Above 95 sq. mm and upto 185 sq. mm (clamped with 25x3mm MS flat clamp)
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Above 95 sq. mm and upto 185 sq. mm (clamped with 25x3mm MS flat clamp)
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Supplying and making cable route marker with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 120 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 120 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required. Above 120 sq. mm and upto 400 sq. mm
Retrievel of one number PVC/XLPE insulated and PVC sheathed power cable of 1.1KV grade of size upto 400 Sqmm from ground including excavation and refilling the trench etc.. as required.
Retrievel of one number PVC/XLPE insulated and PVC sheathed power cable of 1.1KV grade of size upto 400 Sqmm from the existing RCC/ HUME/ STONEWARE/ METAL/ GI PIPES/ Duct/ TRAY/ TERRACE etc., as required.
Retrievel of one number PVC/XLPE insulated and PVC sheathed power cable of 11KV grade of size upto 300 Sqmm from ground including excavation and refilling the trench etc.. as required.
Retrievel of one number PVC/XLPE insulated and PVC sheathed power cable of 11KV grade of size upto 300 Sqmm from the existing RCC/ HUME/ STONEWARE/ METAL/ Duct/ GI Pipe etc., as required.
Retrievel of one number PVC/XLPE insulated and PVC sheathed power cable of 1.1KV grade of size exceeding 120 sqmm but not exceedind upto 400 Sqmm from ground including excavation and relaying after fault rectification using same brick, fresh sand cushioning protective covering and refilling the trench etc.. as required.
Retrievel of one number PVC/XLPE insulated and PVC sheathed power cable of 11KV grade of size exceeding 120 sqmm but not exceedind upto 300 Sqmm from ground including excavation and relaying after fault rectification using same brick, fresh sand cushioning protective covering and refilling the trench etc.. as required.
Laying of one number PVC/XLPE insulated and PVC sheathed power cable of 1.1KV grade of size exceeding 120 sqmm but not exceeding 400 sqmm direct in ground including excavation upto 0.75 Mtrs Depth, sand cushioning, protective covering refilling the trench etc. as required
Laying of one number PVC/XLPE insulated and PVC sheathed Power cable of 1.1KV grade of size exceeding 120 sqmm but not exceeding 400sqmm direct in ground including demolishing cement concrete/bituminous road, excavation of trench of upto 0.75 Mtr Depth refilling the trench making the surface to original finish with CC of 1:3:6 ratio on top (150 mm) etc. as required
Supplying and making indoor end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required.
4 X 16 sq. mm (28mm)
4 X 25 sq. mm (28mm)
3½ X 35 sq. mm (32mm)
3½ X50 sq. mm (35mm)
3½ X 70 sq. mm (38mm)
3½ X 95 sq. mm (45mm)
3½ X 120 sq. mm (45mm)
3½ X 150 sq. mm (50mm)
3½ X 185 sq. mm (57mm)
3½ X 240 sq. mm (62mm)
3½ X 300 sq. mm (70mm)
3½ X 400 sq. mm (82mm)
Supplying and making straight through joint with heat shrinkable kit including ferrules and other insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
4 X 16 sq. mm
4 X 25 sq. mm
3½ X 35 sq. mm
3½ X50 sq. mm
3½ X 70 sq. mm
3½ X 95 sq. mm
3½ X 120 sq. mm
3½ X 150 sq. mm
3½ X 185 sq. mm
3½ X 240 sq. mm
3½ X 300 sq. mm
3½ X 400 sq. mm
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 Core, XLPE Aluminium Conductor cable of 11 KV grade as required
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 Core, XLPE Aluminium Conductor cable of 33 KV grade as required 150 Sq. mm
Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 Core, XLPE Aluminium Conductor cable of 11 KV grade as required
Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 Core, XLPE Aluminium Conductor cable of 33 KV grade as required. 150 Sq. mm
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 300 mm (W) X 62.5 mm (D) X 2.0 mm Thickness
Supplying and making OF HEAT SHRINKABLE OUTER COVERING SLEEVE for following size of PVC/XLPE insulated and PVC sheathed Aluminium conductor cable of 1.1/11/33 KV grade as required.
Upto 3 1/2 x 095-150 Sq.mm 1.1 KV
Upto 3 1/2 x 185-400 Sq.mm 1.1 KV
Upto 3 x 120-185 Sq.mm 11/33 KV
Upto 3 x 240-300 Sq.mm 11/33 KV
Locating the Cable fault on LT/HT feeder cables laid directly in ground/ duct/ pipe including providing Cable Fault Tracer (Rental) etc., as required.
LT CABLES [ONLY IN CASE OF EMERGENCY]
HT CABLES
Supplying and laying of 75 mm OD HDPE Pipe of PE 80 PN 6 ISI Marked along with all accessories like socket, bend etc., confirming to IS 4984 complete with fitting and cutting, jointing etc., direct in ground (1.2 mtr below the ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., as required.
Supplying and laying of 125 mm OD HDPE Pipe of PE 80 PN 6 ISI Marked along with all accessories like socket, bend etc., confirming to IS 4984 complete with fitting and cutting, jointing etc., direct in ground (1.2 mtr below the ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., as required.
SH-V-B : EARTHING
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 Sets of brass nut bolt & spring washer spaced at 50mm)
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 Sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required
Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Providing and fixing MV danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
SH-V-C : SITC of Switch Gear Works
Supply, Replacement, Testing and Commissioning of 400 A, 4P, 50KA, MCCB with Micro Processor release protection, in the existing Panel with CT operated multifunction digital metering class 1.0 with RS485, ON/OFF/Trip Indication Lamps and Phase Indication Lamps i/c providing Handle, providing and fixing 600 A Busbar, with all accessories, interconnection, connection, earthing, painting of door, etc. as required.
Supply, Replacement, Testing and Commissioning of 250 A , 4P, 50KA MCCB with Micro Processor release protection, in the existing Panel with CT operated multifunction digital metering class 1.0 with RS485, Equivalent), ON/OFF/Trip Indication Lamps and Phase Indication Lamps i/c providing Handle, providing and fixing 400 A Busbar, with all accessories, interconnection, connection, earthing, painting of door, etc. as required.
Supply, Replacement, Testing and Commissioning of 400 A 4P MCCB with Micro Processor release in the existing Panel including providing Handle, with all accessories, interconnection, connection, earthing, painting of door, etc. as required.
Supply, Replacement, Testing and Commissioning of 250 A 4P MCCB with thermal magnetic release in the existing Panel including providing Handle, with all accessories, with all accessories, interconnection, connection, earthing, painting of door, etc. as required.
Supply, Replacement, Testing and Commissioning of multifunction digital metering class 1.0 with RS485 (having measuring parameters V, A, F, KW, KVA, KAVr, KWh, KVAh, KVArh, PF, THD)in the existing Panel including with all acessories, interconnection, connection, etc. as required.
Supply, Replacement, Testing and Commissioning of LED indication lamps (R/Y/G) in the existing Panel including with all acessories, interconnection, connection, etc. as required.
Supply, Replacement, Testing and Commissioning of Blue LED indication lamp in the existing Panel including with all acessories, interconnection, connection, etc. as required.
SH-V-D : Labour Works
Cleaning of cable trenches by lifting the cables, supporting the cables, removing waste materials I/c malba, debris etc., and transporting and dumping the same to waste dumping yard etc. as required.
Cleaning of bus ducts I/c removing of covers, checking of bus bars, bus supports, tightening of busses and supports and re-fixing of covers, testing, commissioning etc., as required.
Providing one Skilled Wireman and two Unskilled Khalasi to attend any urgent Preventive Maintenance/ Breakdown Maintenance/ Emergency Work at Electrical Installations provided in Main Power House/ Substations with necessary T&P as and when required.
Providing Labour and Hire Charges for deploying Excavater (JCB) i/c Operator for tracing the cable faults, excavation and refilling of Cable trench after work etc., as required.
Providing one FITTER and ONE Unskilled Khalasi to attend any urgent Preventive Maintenance/ Breakdown Maintenance/ Emergency Work at Electrical Installations provided in Main Power House/Substations with necessary T&P as and when required.
Providing Labour and Hire Charges for deploying WELDING MACHINE i/c WELDER, Welding Rods etc., for WELDING WORKS as required.
Providing Labour and Hire Charges for deploying Lorry/ Truck/ Tractor i/c Operator and loaders for shifting of debris/ wastes from Power Houses/ Substations etc., to waste dump yard as required.
Hire Charges for deploying TEMPO/ SMALL TrucK i/c Operator for shifting of Diesel from Diesel Distribution Station to Power Houses etc., as required.
Providing labour and hire charges for deploying Crane (upto 10 Ton) i/c operator for lifting/ Shifting of Equipments/ Cable Drums, etc., as required.
SH-V-E : Civil Works
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc as required
100 mm dia
150 mm dia
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 300 mm dia
Supplying and laying of "B" Class G.I pipe of following dia, i/c excavation of bituminous/ concrete road/ pavement, excavation of Soil to maximum depth of 1.2 Mtrs from ground refilling the Soil and with CC of ratio 1:3:6 on top for 0.15 Mtrs after laying Pipe and plastering, making good the same etc., as required.
100 mm Dia
150 mm Dia
Construction and Supply of Pre-Cast RCC Manhole Chamber of Internal Dimension 1MX1MX1M (External 1.2MX1.2MX1.2M) with CC of 1:2:4 of thickness 100mm with Square Top Cover of 600X600mm size with L angle reinforced at all side of top and bottom of cover, lifting hook including finishing with Cement Coat as required.
Making of cable trenches of sizes 1 Mtr. (L) X 0.6 Mtr. (W) X 0.6 Mtr. (D) including demolishing of cement concrete/ flooring on existing floor, excavation of trenches of required width upto a depth of 0.8 Mtr. below the concrete area and getting out the excavated soil/sand within a lead of 50 M providing and laying in position 1:4:8 (1 cement : 4 sand : 8 graded stone graded stone 40 mm nominal size.) cement concrete at bottom [20 cm] excluding the cost of centring and shuttering, making of brick wall of thickness 9 inch as required with good quality bricks and cement mortar 1:6 (1 cement :6 coarse sand) and plastering the surface of walls of cable trenches with cement plaster 1:6 ( 1 cement : 6 fine sand) matching with existing trench etc., as required.
Fabrication, Supply and Fixing of 6mm thick chequered plates including providing and fixing 40mmx40mmx6mm angle iron supports on cable trenches, 25mmx6mm MS flat around the chequered plate by welding, providing lifting hook etc., as required.
Supply, fabrication and installation of the MS channel/ angle/ flat for cable tray/ support including cutting, welding, drilling, fixing, grinding, painting etc., as required for composite M.S. works as & when required basis.
Painting of Power Supply Installations with two coats of synthetic enamel paint of approved shade, quality and brand i/c scrapping and cleaning, providing putty wherever required, inscription etc., as required.
Spraying
Brushing
Providing Civil Works as required as detailed below:
Cement concrete in 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20mm nominal size)
Cement mortar in 1:6 (1 cement: 6 coarse sand )
Brick work with bricks of class designation 60 in foundation and plinth in 1:6 (1 cement: 6 coarse sand)
Cement plaster 12mm thick of mixture 1:6
Steel rod for RCC Slabs
SH-V-F : Supply of Cables
Supply of Aluminium Conductor, XLPE insulated, PVC sheathed, armoured power cable of 1.1 KV grade of following Sizes conforming to IS 7098 (Part-1) as amended upto date as required. [AS AND WHEN REQUIRED BASIS ONLY]
4 X 16 sq. mm
4 X 25 sq. mm
3½ X 35 sq. mm
3½ X50 sq. mm
3½ X 70 sq. mm
3½ X 95 sq. mm
3½ X 120 sq. mm
3½ X 150 sq. mm
Supply of compact circular stranded Al conductor provided with conductor screening of semi-conducting compound XLPE insulated provided with insulation screening over individual cores, consisting of extruded semi-conducting compound followed by lapped semi-conducting copper tapes, cores laid together with suitable filters, in the interscripes covered with inner sheath by extrusion, galvanized flat steel strip armoured and overall PVC sheathed cable, suitable for 11 KV (E) System conforming to IS 7098 (Part-II) 1985 as amended upto date and of following Size as required. [AS AND WHEN REQUIRED BASIS ONLY]
3 X 240 Sq.mm
PREMIER ENGINEERING TECHNICS PVT. LTD.
SHRI VAARI ELECTRICALS PVT LTD
DElite System Engineering (India) Pvt. Ltd.
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .