Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical MU PO KOPARDE HAVELI TA KARAD | KARAD | SATARA | MAHARASHTRA | Accepted-Technical accept |
| 2 | Accepted-Technical | Accepted-Technical accept |
| 3 | Accepted-Technical | Accepted-Technical accept |
| 4 | Accepted-Technical | Accepted-Technical accept |
| 5 | Accepted-Technical | Accepted-Technical accept |
Tender Value
₹14.3 L
EMD Value
₹14,293
Closing Date
30 Apr 2026, 5:00 pmClosed
Additional Chief Executive Officer,Z.P.Satara
Additional Chief Executive Officer,Z.P.Satara
Repairs to Medical officer Quarters and Staff Quarters at Masur PHC Dist. Satara
2026_SATAR_1295302_3
A-2/E-Tendering/93/2026
Open Tender
Civil Works
Percentage
at Masur PHC TAL. KARAD Dist. Satara
OPEN CLASS 5 A AND ABOVE
9 documents required · 9 mandatory
₹1,180
₹14,293
7 Oct 2026
16 Apr 2026
4 May 2026
16 Apr 2026
30 Apr 2026
16 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting excetra complete. - (Lift upto 1.5 metre) By Mechanical Means
Item / Page No : 2 / 153
Specification No : Bd.A.1
Spec. Page No : 259 | - | Cubic Metre | - | - |
| 2 | Providing and laying Cast in situ/Ready Mix, cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailling out water, formwork, laying/ pumping, compacting and curing, excetra complete, with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed, excetra) (using ARTIFICIAL SAND).
Item / Page No : 1 / 175
Specification No : Bd.E.1
Spec. Page No : 287-288
Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. | - | Cubic Metre | - | - |
| 3 | Providing soling using 80 milimetre size trap metal in 15 centimetre layer including filling voids with crushed sand / grit, ramming, watering, excetra complete.
Item / Page No : 40 / 157
Additional Specifications : The work shall be carried out as per instructions of Engineer in-charge. | - | Cubic Metre | - | - |
| 4 | Providing and fixing in position thermo mechnically treated FE-500 steel bar reinforcement of various dias for reinforced cement concrete pile caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardis, copings, fins, arches, excetra as per detailed designs, drawings and schedules including cutting, bendding, hooking the bars, binding with wires or tack welding and supporting as requied complete.
Item / Page No : 33 / 188
Specification No : Bd.F.17
Spec. Page No : 306 | - | Metric Ton | - | - |
| 5 | Providing and laying in situ/Ready Mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete work in foundations like raft, strip foundations, grillage and footings of reinforced cement concrete columns and steel stanchions, excetra including bailling out water, formwork, cover blocks, compaction, curing and roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel), excetra complete, with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (using ARTIFICIAL SAND).
Item / Page No : 11 / 178
Specification No : Bd.F.3, B-7
Spec. Page No : 298, 38-40
Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. | - | Cubic Metre | - | - |
| 6 | Providing second class burnt brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 in foundations and plinth of inner walls / in plinth of external walls including bailling out water manually, striking joints, on unexposed faces, racking out joints on exposed faces and watering, excetra complete. (using ARTIFICIAL SAND).
Item / Page No : 1 / 197
Specification No : Bd.G.1
Spec. Page No : 313
Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. | - | Cubic Metre | - | - |
| 7 | Providing internal cement plaster 20 milimetre thick in single coat in cement mortar 1:4 without neeru finish to concrete, brick surface, in all positions including scaffolding and curing, excetra complete. (using ARTIFICIAL SAND).
Item / Page No : 7 / 209
Specification No : Bd.L.4
Spec. Page No : 368
Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. | - | Square Metre | - | - |
| 8 | Providing and fixing machine cut machine polished 18 milimetre to 20 milimetre thick telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on a bed of 1:4 cement mortar including float, filling joints with neat cement slurry, curing, polishing and cleaning, excetra complete. (using ARTIFICIAL SAND).
Item / Page No : 35 / 216
Specification No : Bd.M.22 B
Spec. Page No : 390
Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. | - | Square Metre | - | - |
| 9 | Providing soak pit of size 120 centimetre X 120 centimetre X 120 centimetre including excavating and filling with brick bats.
Item / Page No : 19 / 275
Specification No : Bd.V.46
Spec. Page No : 576 | - | Number | - | - |
| 10 | Providing and laying cement concrete pipe confirming to Indian Standard 458:2003 non pressure class-2 of 450 milimetre diameter in proper line, level and slope including providng and fixing collars in cement mortar 1:2 and curing, excetra complete. (using ARTIFICIAL SAND).
Item / Page No : 8 / 81
Specification No : CD.7
Spec. Page No : 162 | - | Running Metre | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.84 MB
B193.pdf
Tender Documents • 0.88 MB
BOQ_2225565.xls
BOQ • 0.32 MB
CORREGENDUMCOMMONmerged.pdf
PDF • 4.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .