| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.4 LAccepted-AOC | L1 | Accepted-AOC Being L1 bidder. | |
| 2 | L2₹39.8 L+₹1.3 L (3.49%)Rejected-AOC | L2 | Rejected-AOC Not being L1 bidder. | |
| 3 | L3₹41.2 L+₹2.7 L (7.12%)Rejected-AOC | L3 | Rejected-AOC Not being L1 bidder. | |
| 4 | L4₹41.9 L+₹3.4 L (8.91%)Rejected-AOC 2ND FLOOR 2B SORAJ ESTATE ULUBARI K C PATOWARI ROAD ULUABRI KAMRUP ASSAM 781007 | KAMRUP METRO | ASSAM | 781007 | L4 | Rejected-AOC Not being L1 bidder. | |
| 5 | L5₹43.9 L+₹5.4 L (14.1%)Rejected-AOC GOSWAMI COLONY PO UDAYAN VIHAR DISTT KAMRUP ASSAM 781171 | KAMRUP METRO | ASSAM | 781171 | L5 | Rejected-AOC Not being L1 bidder. |
| Sl No | Description | Qty | Unit | M/S TRADE CENTRE L2 | RS COOLING APPLIANCES L4 | M/s Ravi Enterprise L1 | M/s Capital Traders L3 | M.G. ENTERPRISE L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00JOB NO. : 51ASP/SR(E/M)/01/2024-25 | ||||||||
| 1.01 | Taking down of unserviceable any type of ACs, Water coolers, Refrigerators and Water heaters (Geyser) dismantling from all accessories complete collected from existing place and depositted to MES store yard. | 69 | Each | 1,505 ₹1,03,845 | 1,250 ₹86,250 | 700 ₹48,300 Lowest | 1,700 ₹1,17,300 | 1,920 ₹1,32,480 |
| 1.02 | Supply, fixing/install and testing high wall split units air conditioner inverter type indoor/outdoor with cordless remote control unit, electric driven single phase 230 Volt of capacity 1.0 TR, BEE 5 star rated with copper condensing unit complete all as specified and directed. | 1 | Each | 52,000 ₹52,000 | 49,000 ₹49,000 Lowest | 56,200 ₹56,200 | 55,500 ₹55,500 | 53,250 ₹53,250 |
| 1.03 | Supply, fixing/install and testing high wall split units air conditioner inverter type indoor/outdoor with cordless remote control unit, electric driven single phase 230 Volt of capacity 1.5 TR, BEE 5 star rated with copper condensing unit complete all as specified and directed. | 8 | Each | 58,110 ₹4,64,880 | 55,000 ₹4,40,000 | 61,200 ₹4,89,600 | 59,500 ₹4,76,000 | 54,320 ₹4,34,560 Lowest |
| 1.04 | Supply, fixing/install and testing high wall split units air conditioner inverter type indoor/outdoor with cordless remote control unit, electric driven single phase 230 Volt of capacity 2.0 TR, BEE 5 star rated with copper condensing unit complete all as specified and directed. | 16 | Each | 68,000 ₹10,88,000 Lowest | 68,520 ₹10,96,320 | 74,200 ₹11,87,200 | 70,200 ₹11,23,200 | 69,210 ₹11,07,360 |
| 1.05 | Supply & fixing/install refrigerator, electric driven single phase 230 Volt of capacity upto 210 Litres, BEE 5 star rated free ever cooling complete all as specified and directed. | 1 | Each | 45,000 ₹45,000 | 42,500 ₹42,500 | 34,960 ₹34,960 Lowest | 46,200 ₹46,200 | 40,420 ₹40,420 |
| 1.06 | Supply & fix refrigerator, electric driven single phase 230 Volt of capacity upto 310 Litres, BEE 5 star rated complete all as specified and directed. | 3 | Each | 55,000 ₹1,65,000 | 55,620 ₹1,66,860 | 51,600 ₹1,54,800 Lowest | 56,000 ₹1,68,000 | 56,740 ₹1,70,220 |
| 1.07 | Supply & fix water cooler, electric driven single phase 230 Volt having approx capacity of 80 Litres and nominal cooling capacity 40 Litres pere hour. complete all as specified and directed. | 3 | Each | 55,000 ₹1,65,000 | 52,600 ₹1,57,800 | 49,000 ₹1,47,000 Lowest | 59,000 ₹1,77,000 | 69,250 ₹2,07,750 |
| 1.08 | Supply & fix water cooler, electric driven single phase 230 Volt having approx capacity of 120 Litres and nominal cooling capacity 60 Litres pere hour. complete all as specified and directed. | 5 | Each | 65,000 ₹3,25,000 | 62,000 ₹3,10,000 | 43,500 ₹2,17,500 Lowest | 62,500 ₹3,12,500 | 64,350 ₹3,21,750 |
| 1.09 | Supply & fixing for electric water heater (Geyser), storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 Ltrs, BEE 5 star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc, complete all as specified and directed. | 32 | Each | 13,500 ₹4,32,000 | 18,000 ₹5,76,000 | 10,900 ₹3,48,800 Lowest | 14,500 ₹4,64,000 | 19,200 ₹6,14,400 |
Tender Value
Refer Docs
EMD Value
₹75,000
Closing Date
7 Aug 2025, 6:00 pmClosed
GE (P) AF Digaru
GE (P) AF Digaru PO Digaru Dist Kamrup Assam 782401
SPECIAL REPAIR / REPLACEMENT OF BER FANS, EXHAUST FANS, SPLIT AC, REFRIGERATORS, DEEP FREEZERS, WATER COOLER, GEYSERS AND SPECIAL REPAIR TO CERTAIN BUILDINGS AT MT HANGERS AT AF STN DIGARU.
2025_MES_719820_1
C/8807/E8 of 2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Digaru
Please ref Tender Documents
6 documents required · 6 mandatory
₹500
GE (P) AF Digaru
₹75,000
Yes
13 Oct 2025
11 Jul 2025
14 Aug 2025
11 Jul 2025
7 Aug 2025
26 Jul 2025
Amount
JOB NO. : 51ASP/SR(E/M)/01/2024-25
Taking down of unserviceable any type of ACs, Water coolers, Refrigerators and Water heaters (Geyser) dismantling from all accessories complete collected from existing place and depositted to MES store yard.
Supply, fixing/install and testing high wall split units air conditioner inverter type indoor/outdoor with cordless remote control unit, electric driven single phase 230 Volt of capacity 1.0 TR, BEE 5 star rated with copper condensing unit complete all as specified and directed.
Supply, fixing/install and testing high wall split units air conditioner inverter type indoor/outdoor with cordless remote control unit, electric driven single phase 230 Volt of capacity 1.5 TR, BEE 5 star rated with copper condensing unit complete all as specified and directed.
Supply, fixing/install and testing high wall split units air conditioner inverter type indoor/outdoor with cordless remote control unit, electric driven single phase 230 Volt of capacity 2.0 TR, BEE 5 star rated with copper condensing unit complete all as specified and directed.
Supply & fixing/install refrigerator, electric driven single phase 230 Volt of capacity upto 210 Litres, BEE 5 star rated free ever cooling complete all as specified and directed.
Supply & fix refrigerator, electric driven single phase 230 Volt of capacity upto 310 Litres, BEE 5 star rated complete all as specified and directed.
Supply & fix water cooler, electric driven single phase 230 Volt having approx capacity of 80 Litres and nominal cooling capacity 40 Litres pere hour. complete all as specified and directed.
Supply & fix water cooler, electric driven single phase 230 Volt having approx capacity of 120 Litres and nominal cooling capacity 60 Litres pere hour. complete all as specified and directed.
Supply & fixing for electric water heater (Geyser), storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 Ltrs, BEE 5 star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc, complete all as specified and directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for infput variation between 170 Volt to 250 Volt with uotput voltage stabilized at 230 Volt with accuracy of + 2.5% and capacity 5.0 KVA complete all as specified and directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for infput variation between 170 Volt to 250 Volt with uotput voltage stabilized at 230 Volt with accuracy of + 2.5% and capacity 3.0 KVA complete all as specified and directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for infput variation between 170 Volt to 250 Volt with uotput voltage stabilized at 230 Volt with accuracy of + 2.5% and capacity 1.0 KVA complete all as specified and directed.
Taking down of unserviceable any size of Fan ceiling/exhaust/ wall/pedestal including dismantling from all accessories collected from existing place and depositted to MES store yard complete all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1400 mm sweep. Min air delivery 245 CFM with service value 6.00 BEE Five star rated with brushless direct current motor (BLDC) accessories colmplete all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE Five star rated with brushless direct current motor (BLDC) accessories colmplete all as specified and directed.
S & F for Exhaust fan of size 450 mm sweep, 1400 RPM steel body AC single phase 230 Volt with including blades, frame and louvers complete all as specified and directed.
S & F Exhaust fan of size 300 mm sweep, 1400 RPM steel body AC single phase 230 Volt with including blades, frame and louvers complete all as specified and directed.
Supply and Fixing Wall Fan of size 400 mm, Single phase 230 Volt complete with louver accessories all as specified and directed.
Supply and Fixing Pedestal Fan of size 400 mm, Single phase 230 Volt complete with louver accessories all as specified and directed.
Taking down of unserviceable any size of sub main wiring including PVC conduit with all accessories collected from existing place and depositted to MES store yard complete all as specified and directed.
M&L for sub main wiring complete with two runs of 4 sqmm single core FRLS PVC insulated unsheathed cable, 1100 volt grade, multistranded copper conductor cable including one run of 4 sqmm single core FRLS PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 20 mm dia non metallic rigid PVC conduit/casing capping and all accessories of suitable size and accessories on surface of wall / roof etc. complete all as specified and as directed.
M&L for sheet metal enclosure with socket plg top and MCBs for single pole and neutral encloser with a two pin and earth plug and socket complete with one single pole MCB of 32Amp rating, 240 volts complete all as specified and directed.
JOB NO. : 51ASP/SR(B/R)/06/2023-24
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete of any type & specification, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.
Material and Labour for point wiring with FRLS PVC insulated unsheathed, stranded copper conductor cable single core 1.5 Sqmm for one light point/fan point controlled by one one way switch incl one PVC insulated, un sheathed single core stranded copper conductor cable of size 1.5 Sqmm for continues earth wire drawn in and including PVC conduit of suitable size complete with all accessories including sheet metal MS box of suitable size of 1.2mm thick or PVC rectangular switch board of suitable size incl 3.0 mm thick laminated sheet cover and fixed with brass screws, cap washers etc to be fixed flushed on wall including white washing/colour washing/distembering to match the disturbed surfaces complete all as specified & directed.
All as per Ser item No. 2.02 above but with 2.5 Sqmm single core copper conductor for one 16A socket outlet on independent board.
M & L switch piano flush type, single pole, one way, 5 amps 230 volts complete all as specified & directed.
S&F switch socket combination 2 in 1, 3 pin 6/16 Amps flush type universal.
S&F in repair ceiling rose, surface bakelite 65x50 mm three terminal.
Supply and fixing LED lights fitting 1x 18 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
S&F LED security light fitting 35 Watt 230 V AC outdoor tyoe with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection alongwith bracket for fixing of security light fitting made with 32 mm dia light grade GI pipr (not less than 1 mtr long) with and including MS clamp and two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
S&F of MCB SPN DB, 12 way made of sheet steel phosphatised, powder painted with 200 Amps rated busbar, neutral link, earthbar and Din rail, 230 Volts with double door complete all as specified and directed.
Supply, fixing, connection and testing MCB SPN 240 Volts, 'C' series, breaking capacity 10KA of rating 6-32 Amps.
Supply, fixing, connection and testing MCB SP 240 Volts, 'C' series, breaking capacity 10KA of rating 6-32 Amps.
Earthing complete with galvanised steel earth plate electrode 60cm x60cm x6 mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level ) with top edge of earth plate not less than 1.5m below ground level, connecting to the Galvanised iron wire 4.0 mm dia as earthing lead, by means of nuts, bolts, check nuts and washer etc. of galvanised iron and earth lead protected by provision of GI pipe light grade 25 mm bore light grade from earthing test point or main controling switch as directed including providing funnel with 20mm bore GI pipe light grade, wire mesh, charcoal or coke and common salt in alternative layer of 15 Cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:2:4) type B-1 using 20mm graded stone agagregates with 50mm thick cover of RCC (1:2:4) (re-inforced with 8mm dia TMT bar @15 cm C/C bothways and MS bar handle made of 10mm dia bar) including necessary earth work in excavation, returning in and removal of surplus soil to a distance not exceeding 50mtr, all as per electrical plate No 3 of MES Schedule Part-I including earthing pit cover etc. including taking down old unsv one complete all as specified and directed.
Supply & laying cable XLPE insulated screened PVC bedded, Galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 Sqmm x 2 core complete all as specified and directed.
Excavation in trenches in any type of soil (soft/loose) not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for LT underground cables / GI pipes for trenches complete all as specified and as directed.
Returning, filling in including spreading watering and well ramming in layers not exceeding 25cm in layers complete all as specified and directed.
Removal of surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L sand coushioning to UG cables (8cm deep before laying of cables and 15 cm over the cable) including spreading, levelling, well ramming in layers. Note : L Punned thickness of 18cm only will be considered for payment purpose.
S&F sub class 'B' bricks of standard size for cable protection in trenches complete all as specified and directed.
S&F GI tubing light grade 40mm dia for protection pipe complete all as specified and directed.
M/S TRADE CENTRE (BID ID -3376190)
M/s Capital Traders (BID ID -3376920)
RS COOLING APPLIANCES (BID ID -3377467)
M.G. ENTERPRISE (BID ID -3378627)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .