| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.7 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹39.2 L+₹5.0 L (14.7%)Rejected-Finance | L2 | Rejected-Finance LOWEST OTHER BIDDERS | |
| 3 | L2₹40.1 L+₹5.9 L (17.4%)Rejected-Finance | L2 | Rejected-Finance LOWEST OTHER BIDDERS | |
| 4 | L4₹40.3 L+₹6.2 L (18.1%)Rejected-Finance | L4 | Rejected-Finance LOWEST OTHER BIDDERS | |
| 5 | L5₹45.5 L+₹11.3 L (33.1%)Rejected-Finance 0 MANPUR CHITBARAGAON CHITBARAGAON BALLIA UTTAR PRADESH 221713 | BALLIA | UTTAR PRADESH | 221713 | L5 | Rejected-Finance LOWEST OTHER BIDDERS |
| Sl No | Description | Qty | Unit | M/S PARSHOTAM KUMAR GUPTA L3 | narayan construction L1 | M/S BHATT TRADERS L2 | NATIONAL TRADING COMPANY L5 | MEELU ENTERPRISES L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | True vertical steel tubular swaged pole, 9 metre long, complete with mild steel base plate 6mm thick of size 300mm x 300mm, B-118 finial taper plug, bolts, nuts, washers and screws, type 410 SP-31 including drilling of holes of required size and nuts for fixing of cross arms, painting with two coats of aluminium paint over a coat of red oxide and two coats of black bituminous paint for portion embedded in concrete, painting five black and white bands at lower portion of pole each of 300 mm height at 300mm spacing complete all as specified and directed.
(Note : Excavation, earth work and PCC in foundation of poles, coping etc shall be measured and paid separately under respective items of work). | 12 | Each | 11,000 ₹1,32,000 Lowest | 15,000 ₹1,80,000 | 11,000 ₹1,32,000 Lowest | 11,000 ₹1,32,000 Lowest | 16,500 ₹1,98,000 |
| 2.00 | Energy efficient LED street light fitting, 75W, input voltage 230VAC, 50Hz with ingress protection IP 65, CRI >70, PF>0.9, minimum 25000 burning hous, LM-80, lumen efficacy ≥100 lumen/watt, THD> 20, CRCA housing including all fixing arrangment like clamps, nuts, bolts, washers, LED lamp with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable with all necessary staging, etc. for fixing at any locations, complete all as specified and directed. | 3 | Each | 2,700 ₹8,100 | 2,000 ₹6,000 Lowest | 5,000 ₹15,000 | 2,500 ₹7,500 | 2,600 ₹7,800 |
| 3.00 | Factory made PVC pole mounted street light junction box, three phase and neutral, 415 volts, weather proof of size 155x155x100mm depth, accommodated with properly insulated 04 Nos of aluminium busbar of 40 Amps rated current cap, 02 Nos of insulators per each bus bar, nut bolts & clamps of GI flat iron of size 25x3 mm for fixing of junction box etc. and including MCB SP 6 Amps - 01 Nos, for connecting of security light fittings, with hinged door and locking bolt complete all as specified and directed. | 133 | Each | 900 ₹1,19,700 | 1,000 ₹1,33,000 | 600 ₹79,800 Lowest | 850 ₹1,13,050 | 800 ₹1,06,400 |
| 4.00 | Timer switch 415 V, three Phase of 20 Amp rating with contactor fitted inside steel enclosure, complete all as specified and directed. | 1 | Each | 8,000 ₹8,000 | 2,500 ₹2,500 | 20,000 ₹20,000 | 5,500 ₹5,500 | 1,900 ₹1,900 Lowest |
| 5.00 | Cable LT XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor, 1100 volt grade, cross sectional area 35 sqmm 3.5 core laid in trenches/ on floor or passing through pipe/ under road complete all as specified and directed. | 200 | RM | 200 ₹40,000 Lowest | 249 ₹49,800 | 220 ₹44,000 | 210 ₹42,000 | 255 ₹51,000 |
| 6.00 | Cable LT XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor, 1100 volt grade, cross sectional atea 16 sq mm 4 core laid in trenches/ on floor or passing through pipe/ under road complete all as specified and directed. | 3,510 | RM | 100 ₹3,51,000 Lowest | 150 ₹5,26,500 | 280 ₹9,82,800 | 195 ₹6,84,450 | 135 ₹4,73,850 |
| 7.00 | Excavation in trenches n.exc 1.5m wide and n.exc 1.50m in depth for taking up or laying of under ground cable in soft/loose soil and getting out complete all as specified and as directed. | 346 | Cum | 80 ₹27,680 Lowest | 100 ₹34,600 | 150 ₹51,900 | 150 ₹51,900 | 100 ₹34,600 |
| 8.00 | Excavation in trenches not exc 1.5 m wide and depth exceeding 1.50 m and not exceeding 3m complete all as specified and directed. | 0.2 | Cum | 100 ₹20 | 20 ₹4 Lowest | 100 ₹20 | 250 ₹50 | 100 ₹20 |
| 9.00 | Returning, filling in of soil in trenches including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick complete all as specified and as directed. | 206 | Cum | 10 ₹2,060 Lowest | 20 ₹4,120 | 50 ₹10,300 | 230 ₹47,380 | 30 ₹6,180 |
| 10.00 | Removal of excavated soil not exc 50 m distance and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and as directed. | 137 | Cum | 10 ₹1,370 Lowest | 20 ₹2,740 | 40 ₹5,480 | 50 ₹6,850 | 100 ₹13,700 |
Tender Value
₹48.5 L
EMD Value
₹97,000
Closing Date
20 Oct 2025, 6:00 pmClosed
GE 881 EWS
GE 881 EWS C/O 56 APO
SPL REPAIR TO SECURITY LIGHTS, CABLES, POLES AND ACCESSORIES AT MENDHAR AND SPL REPAIR TO SECURITY LIGHTS, JUNCTION BOXES WITH OTHER ALLIED WORKS AND WATER PIPE LINE WORKS AT BG AND SPL REPAIR TO BUILDING NO T-12 (COOK HOUSE) OF SIGNAL COY AT BG
2025_MES_732303_1
GE/PNH-70/2025-26
Open Tender
Civil Works
Item Rate
180 days
GE 881 EWS C/O 56 APO
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE 881 EWS
₹97,000
Yes
19 Dec 2025
23 Sept 2025
22 Oct 2025
23 Sept 2025
20 Oct 2025
7 Oct 2025
Amount
True vertical steel tubular swaged pole, 9 metre long, complete with mild steel base plate 6mm thick of size 300mm x 300mm, B-118 finial taper plug, bolts, nuts, washers and screws, type 410 SP-31 including drilling of holes of required size and nuts for fixing of cross arms, painting with two coats of aluminium paint over a coat of red oxide and two coats of black bituminous paint for portion embedded in concrete, painting five black and white bands at lower portion of pole each of 300 mm height at 300mm spacing complete all as specified and directed. (Note : Excavation, earth work and PCC in foundation of poles, coping etc shall be measured and paid separately under respective items of work).
Energy efficient LED street light fitting, 75W, input voltage 230VAC, 50Hz with ingress protection IP 65, CRI >70, PF>0.9, minimum 25000 burning hous, LM-80, lumen efficacy ≥100 lumen/watt, THD> 20, CRCA housing including all fixing arrangment like clamps, nuts, bolts, washers, LED lamp with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable with all necessary staging, etc. for fixing at any locations, complete all as specified and directed.
Factory made PVC pole mounted street light junction box, three phase and neutral, 415 volts, weather proof of size 155x155x100mm depth, accommodated with properly insulated 04 Nos of aluminium busbar of 40 Amps rated current cap, 02 Nos of insulators per each bus bar, nut bolts & clamps of GI flat iron of size 25x3 mm for fixing of junction box etc. and including MCB SP 6 Amps - 01 Nos, for connecting of security light fittings, with hinged door and locking bolt complete all as specified and directed.
Timer switch 415 V, three Phase of 20 Amp rating with contactor fitted inside steel enclosure, complete all as specified and directed.
Cable LT XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor, 1100 volt grade, cross sectional area 35 sqmm 3.5 core laid in trenches/ on floor or passing through pipe/ under road complete all as specified and directed.
Cable LT XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor, 1100 volt grade, cross sectional atea 16 sq mm 4 core laid in trenches/ on floor or passing through pipe/ under road complete all as specified and directed.
Excavation in trenches n.exc 1.5m wide and n.exc 1.50m in depth for taking up or laying of under ground cable in soft/loose soil and getting out complete all as specified and as directed.
Excavation in trenches not exc 1.5 m wide and depth exceeding 1.50 m and not exceeding 3m complete all as specified and directed.
Returning, filling in of soil in trenches including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick complete all as specified and as directed.
Removal of excavated soil not exc 50 m distance and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and as directed.
Dry sand river for cushioning with layers of sand 8 cm thick before laying of cable and 15 cm thick after laying of cable note in trenches, duly punning plinned thicknes shall be complete all as specified & directed. ( Note: Thickness after punning shall be measured for payment )
Old size bricks burnt best quality locally available bricks laid in trenches perpendicular to UG cable for cable protection, complete all as specified and as directed.
40mm bore galvanised steel water tubing, light grade including all fittings, fixed to pole / along wall / floor etc for protection of cable/strip including MS clamp, nuts, bolts etc complete all as specified and as directed.
Making bore to road/cement path/hard standing/Taxi track for providing GI pipe 40mm, both end socketed for passing armoured cable incl making good the disturbed surface complete all as specified and directed.
Double wall corrugated pipe (DWC) of 50mm dia conforming to IS: 16205 part-24 and IES 61386 (Part-24) for cable protection laid in trenches, complete all as specified and directed by Engr-in-Charge.
Cable end jointing kit for 1.1 KV grade suitable for outdoor type terminal heat shrinkable type joints with jointing material for 4/3.5 core XLPE armoured aluminium conductor cable of size 16 Sqmm to 50 Sqmm complete all as specified and directed.
Bus bar chamber of size 600x600x450mm suitable for 3 phase 433V outdoor type fabricated out of 3.15mm thick MS sheet with 300A rated aluminium busbar 4Nos., PVC sleeves (coloured red, yellow, blue and black) with suitable locking arrangments and four legged angle iron stand made of angle iron of size 40x40x6mm duly grouted in and including foundation in PCC 1:2:4 type B1 (using 20mm graded stone aggregates) alongwith all necesary cable connections, lugs and cable glands including applying two coats of synthetic enamel paint (of approved tint) over a coat of red oxide zinc chrome primer, complete all as specified and as directed.
PCC 1:3:6 (nominal mix) type C-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete, complete all as specified and as directed
Coping for steel tubular poles with PCC 1:2:4, Type B-1 (using 20 mm graded stone aggregate) for coping of poles including necessary form work and finishing the exposed surface even and smooth with out using extra cemen, including necessary work complete all as specified and as directed.
Earthing complete with galvanized steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected to and including galvanized earth lead strip 32 x 6 mm size upto 7.5 mtrs long by means of nuts and bolts, check nuts and washers of GI and connected to earhi test point and earth dolly all as shown in electrical plate No 3 of MES SSR part I and testing on completion including necessary excavation and earth work in any type of soil, PCC(1:3:6)type C1 chamber, pre-cast RCC slab 50mm thick in cement concrete (1:2:4),type B1,reinforced with welded steel wire fabric or XPM,(weight not less than 4 Kg per Sqm) with cast iron frame,funnel with watering pipe 20mm dia medium grade,wire mesh and lugs,GI protection pipe 40mm dia, light grade, 7.5 mtr long for protection of earth lead upto test point etc completed all as specified and as directed.
Earthing complete with galvanized steel earth plate electrode of size 600x600x6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected to and including galvanized earth lead wire 4.0 mm dia upto 7.5 mtrs long by means of nuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dolly all as shown in electrical plate No 3 of MES SSR part I and testing on completion including necessary excavation and earth work in any type of soil, PCC(1:3:6) type C1 chamber, pre-cast RCC slab 50mm thick in cement concrete (1:2:4), type B1, reinforced with welded steel wire fabric or XPM, (weight not less than 4 Kg per Sqm) with cast iron frame, funnel with watering pipe 20mm dia medium grade, wire mesh and lugs, GI protection pipe,15mm dia,light grade, 7.5 mtr long for protection of earth lead upto test point etc all as specified and as directed.
Energy efficient LED street light fitting, 60W, input voltage 230VAC, 50Hz with ingress protection IP 65, CRI >70, PF>0.9, minimum 25000 burning hours, LM-80, lumen efficacy ≥100 lumen/watt, THD> 20, CRCA housing including all fixing arrengment like clamps, nuts, bolts, washers, LED lamp with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable with all necessary staging, etc. for fixing at any locations, complete all as specified and directed.
Street light bracket made out of GI tubing 40mm bore, medium grade, 1.5 metre long bent to shape as directed, including suitable MS clamp of MS Flat with MS bolts, nuts and washer fixed to steel tubular pole/PCC pole duly painted with two coats of aluminium paint complete, complete all as specified and as directed.
PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sq mm ,3 core, 1100 Volts grade complete all as specified and as directed.
Cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core, complete all as specified and as directed.
Instantaneous electric water heater, steel body with stainless steel inner tank and heating element upto 3 KW capacity 3 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, PVC connection pipe etc complete all as specified and as directed.
Rigid non-metallic 20mm PVC conduit exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends, and fixing accessories such as couplers, lock nuts, saddles, pipe hooks, etc. complete all as specified and as directed.
Galvanized iron, medium pipe with and including all fittings such as elbows, tees, nipples, , reducess and short piecies of size 40 mm bore laid in trenches/ under road/ path complete all as specified and directed by Engr-in-Charge.
Description as all as per srl item No 30 above but 25 mm bore pipe complete all as specified and directed by Engr-in-Charge.
Description as all as per srl item No 30 above but 20 mm bore pipe complete all as specified and directed by Engr-in-Charge.
Gun metal globe gate valve of size 40 mm dia with iron wheel, screwed at both ends complete all as specified and directed by Engr-in-Charge.
Gun metal globe gate valve of size 25 mm dia with iron wheel, screwed at both ends complete all as specified and directed by Engr-in-Charge.
Gun metal globe gate valve of size 20 mm dia with iron wheel, screwed at both ends complete all as specified and directed by Engr-in-Charge.
Cutting through existing bituminous road /PCC/floor/approx size 5cm X 60cm along cross section of the road for laying of GI tubing and repairing the road with existing specification to match with the original finish, complete all as specified and directed.
Drilling/Tapping the existing DI/CI/GI pipe line for fixing tee / bend etc of pipe of 50/80 mm bore including necessary fittings complete all as specified and directed
B/R Portion: Demolition of cement concrete (including floor tiles, kota stone flooring etc) (un-reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing debris and rubbish off the premises and stacking serviceable tiles complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 sqm each complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area exceeding 1.50 sqm and not exc 4 Sqm each complete all as specified and directed.
Taking up or down 15 mm bore steel tubing and connections, including cleaning for re fixing complete all as specified and directed.
Taking up or down 20 mm bore steel tubing and connections, including cleaning for re fixing complete all as specified and directed.
Disconnecting/dismantling PVC water tanks of capacity 1000 Ltrs from roof top complete all as specified and directed.
Disconnecting/dismantling water tanks of capacity 500 Ltrs from roof top complete all as specified and directed.
Demolition of Brick work or stone/boulder masonry, built in Cement Mortar or cement lime mortar incl all quions, arches, pillars etc complete all as specified and directed.
Walling of random rubble stone masonary, uncoursed, well bonded, bedded and solidly hearted built in cement mortar in CM 1:6 complete all as specified and directed.
All as per item No 48 above but except stone.
Extra over stone walling for hammer dressing to face stones & dressing of face beds and joints, with max.depression on face from straight edge held against the dressed surface n exc.20mm in granite, trap or basalt stone of random rubble walling, uncoursed or brought upto courses complete all as specified and directed.
Raised pointing to random rubble stone masonary, uncoverd, RR masonry in CM 1:4 complete all as specified and directed.
Brick work with sub class 'B' bricks straight of curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and directed.
Cement concrete 25 mm thick type B-0, 1:2:4 (12.5mm graded stone aggregate) as in flooring, roof etc complete all as specified and directed by Engr-in-Charge.
50 mm thick plain cement concrete type C2 ( 1:3:6)( using 40 mm graded stone aggregate ) as in plinth protection, laid in alternate bays (not exceeding 2 Sqm each) finished even and smooth at top without using extra cement and providing joints throughout the thickness of plinth protection, filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and directed.
GI wire chicken mesh of size 25mmX25mm to concrete of joists, etc. in walls, ceilings, stanchions, beams, etc. including all laps, cutting and waste complete all as specified and directed.
Rendering 10mm thick in cement mortar 1:4 on fair faces of brick or concrete surface of walls and finished the surfaces even & fair without using extra cement complete all as specified and directed.
15 mm thick rendering on fair faces of brick work or cement concrete surfaces in cement mortar 1:4, finished even and smooth without using extra cement incl mixing of water proofing compound complete all as specified and directed. (Note: Water Proofing compound shall be measured and paid for separately)
Complete removal of existing treatment of any description, including preparation of surfaces, on wall surfaces of any description and applying two coats of cement base paint complete all as specified and directed.
Preparation of new plastered wall surface and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
Complete removal of existing treatment of wall surfaces of any description complete all as specified and directed.
Applying wall care putty 1 to 2mm thick, in two layers on wall surfaces & smoothening the surfaces with sand papers etc., (preparatory to OBD/ plastic emulsion/ interior/ exterior emulsion paint as directed) complete all as specified and directed. MAKE: ASIAN, BIRLA, JK, WEBER.
Appling two coats of distemper oil emulsion (OBD) on wall on prepared surface complete all as specified and directed.complete all as specified.
Glazed ceramic coloured tiles of size 300x450x 7mm thick on vertical surfaces of wall such as skirting/ daeto set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 10mm thick rendering in CM (1:4) backing of wall tiles complete all as specified and directed.
Non skid ceramic coloured ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of mortar 15mm thick for laying floor finishes in CM (1:4) complete all as specified and directed.
18-20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including moulding of corners as required, complete all as specified and directed.
Aluminium anodised barrel tower bolts of extruded section with 200 mm long bolt, complete all as specified and directed.
150 mm size Mild steel pressed handles, oval type, stove enameled black complete all as specified and directed.
Preparation of new steel or iron surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
Steel ventilators fixed type with glazing bars and with top hung shutter including hinges, steel peg stay,complete all as specified and directed.
15 mm bore tube medium grade galvanized iron with all fittings & fixed complete to walls & ceiling or laid in floors complete all as specified and directed.
20 mm bore tube medium grade galvanized iron with all fittings & fixed complete to walls & ceiling or laid in floors complete all as specified and directed.
PVC 1000 litre capacity, triple layered polyethylene water storage tanks with threaded lead (cylindrical vertical with closed top) including hoisted and fixed in position, making connections, complete all as specified and directed.
PVC 500 litre capacity, triple layered polyethylene water storage tanks with threaded lead (cylindrical vertical with closed top) including hoisted and fixed in position, making connections, complete all as specified and directed.
Nipple 20mm dia suitable for HDPE water tank. (Minimum weight 20mm - 45gms) complete all as specified and directed.
Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed. (Minimum weight 20mm - 210 g ms) complete all as specified and directed.
Supply only liquid water proofing compound complete all as specified and directed. (Makes :Pidilite Industries / Impermo /Snowcem India Ltd / Sika
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
Pre-painted galvalume aluminium zinc GI based profile pattern steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa, as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed by Engineer- in Charge.
Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa, as in ridge covering/cladding to wall, fixed with self tapping screws as specified and directed by Engineer- in Charge.
Dismantling wooden scantlingunframed of any size and shape and in position complete all as specified and directed.
Cleaned sawn timber scantling of second class hard-wood (hollock/sal) as in purlins etc complete all as specified and directed.
Cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in foundations filling and mass concrete complete all as specified and directed.
RCC M-25 desigh mix (using 20mm graded aggregate)Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
RCC M-25 desigh mix (using 20mm graded aggregate) for columns, pillars, piers, post and strut complete all as specified and directed.
RCC M-25 design mix (using 20mm graded aggregate) Beams, cantilevers,bressummers, lintels over 1.5m span complete all as specified and directed.
Flat formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter with fain finish surface of concreate complete all as specified and directed.
Flat Formwork to sides of pillars, posts, struts, piers, columns and stanchions with rough finish surface of concreat complete all as specified and directed.
Formwork to sides and soffits of floor or roof beams, beam haunch?ings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc with rough finish surface concreat complete all as specified and directed.
Mild steel TMT bars 10mm dia and over cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
ALL as per Srl item 90 above but 5 to 10 mm dia as in as stirrups completed all as specified and directed.
Demolition Stone slabs and tiles of any description or thickness in floors, aprons etc, laid, bedded and pointed in any mortor complete all as specified and directed.
Pre polised Kota stone slab 20-25mm thick in flooring laid over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polising complete all as specified and directed.
E&M Portion:Taking down carefully aluminium/copper point wiring (light, fan socket or power) complete including fittings & fixtures such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. and making good disturbed surfaces of walls, floors etc complete all as required and keeping serviceable light fittings in safe custody for reuse in the work as directed.
Point wiring on wall/ surface in PVC casing caping of size 20mm complete with 1.5 Sqmm single core multistranded copper conductor FRLS PVC insulated and unsheathed cable 1100 volts grade drawn through including PVC casing caping and provisining of 1.5 sqmm FRLS PVC insulated unsheathed cable 1100 volt grade with multi stranded copper conductor to common earth and connected to earth dolly with sunken type pressed steel/welded MS terminal boxes made out of 1.6 mm MS sheet, 3mm thick laminated sheet top cover for mounting of fittings,switches, sockets outlets,regulators etc complete One light/Fan point controlled by one switch 5 amp one way complete
All as per item No 96 but One 3 pin 5 Amps socket point controlled by one switch on same board.
All as per item No. 96 but One 3 pin 5 Amps socket point controlled by one switch on independent board.
All as per item No. 96 but point wiring with 2.5 sqmm single core multi stranded copper conductor FRLS PVC insulated & unsheathed cable 1100 volt grade and 2.5 sqmm FRLS PVC insulated and unsheathed cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 amp multi purpose socket combination point on independent board.
Submain wiring with 2 runs of copper conductor FRLS PVC insulated unsheathed cable 1100 volt grade 4 sqmm drawn through PVC casing caping 25mm dia ISI marked as per IS specification fixed on wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 4 Sqmm FRLS multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distamper all as directed at site Note : Two runs of 4 sqmm cable alongwith one run of 4 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length complete all as specified and directed .
Switch piano flush type single pole, one way 6 amp complete all as specified and directed
Socket outlet 2 in 1 , 3 pin 5 A flush type complete all as specified.
Switch piano flush type single pole, one way 15 amp complete all as specified and directed .
Socket outlet 2 in 1 , 3 pin 15 A flush type complete all as specified and directed.
Ceiling rose 65x50mm three terminals 230 volt complete all as specified and directed.
Lamp holder,PVC/Polycarbonate type and back plate suitable for batten fitting complete all as specified.
Inverter LED lamp, CDL 9 watt, B22 base, complete all as specified and directed.
Replacemnt 1100 Volts grade heavy duty capble PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspebded by insulating hangers not more than 1 mtr apart incl 4mm suspension wire one twin core flat of size 16 sqm sold aluminium conductor complete all as specified and directed.
Inverter LED batten 1x 20W, with square profile and polycarbonate channel, lithium iron battery with charging time of 8 to 10 hours and backup tile upto 04 hours with driver, holder incl LED tube light connecting up with with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
Sheet metal enclosures for MCB distribution board 230 Volts single pole and neutral 12 way double door type flushed inside the wall with 200 Amp rated bus bar incl making the surface good complete all as specified and directed.
Sheet metal enclosures for MCB distribution board 230 Volts single pole and neutral 8 way double door type flushed inside the wall with 200 Amp rated bus bar incl making the surface good complete all as specified and directed.
MCBs SPN 63 amp B curve 240 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB complete all as specified and directed.
MCBs SPN 40 amp B curve 240 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB complete all as specified and directed.
MCBs SP 5 to 32 amp B curve 240 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB complete all as specified and directed.
Heavy duty exhaust fan, steel body AC Single Phase, 230V size 300mm sweep with, blades, and frame and louvers complete all as specified and directed.
Providing opening and grouting the nuts and bolts for fixing of exhaust fan in wall incl civil work as required on site and making the good disturbed surface, complete all as specified and directed by Engineer-in-Charge.
Taking down ceiling fan, sealing cable end, dismantling blades and removing fan and blades, complete all as specified and directed by Engineer-in-Charge.
Rewinding the ceiling fan 1200mm Sweep with the same gauge of copper winding wire as well as number of turns and reassembling the fan after replacing the unserviceable spares like bushes, shafts, fasteners, bearings, capacitors and flexible cord for putting fan in serviceable condition including refixing the same after carrying out necessary repairs to original place all as directed by Engineer-in-Charge.
Painting of ceiling fans and writing of MES No on fans in situ with synthetic enamel paint by spraying incl filling cavities with filler, one coat after cleaning all dust etc, complete all as specified and directed by Engineer-in-Charge.
Ceiling fans complete with three blade, down rod, accessories 230V, 1200mm sweep, BLDC fan with 5 star rating including fan regulator electronic type with 5 step speed complete all as specified and as directed.
Replacement 50mm HDPE pipe PN 10 and fitting include for jointing and jointing materials for cable protection laid in trenches, complete all as specified and directed by Engineer-in-Charge
Energy efficient LED light fitting, 45W, input voltage 110V to 280VAC, 50Hz with ingress protection IP 66, LM 80, stranded luminries with efficiency 100lumen/Watt, with secondary optics, perfectly matched lenses, complying to IEC60598/IS10322, with auto shut down on high voltage, CRI>70, PF>0.95, with short circuit & reverse circuit protection against 10kV high surges, minimum 25000 burning hours (life), operating temperature 1 to 50oC, rectangular shape with pressure die cast aluminium housing with weather proof gasket for lamp and driver compartment with system wattage of 35W=10%W, rated lumens, 120o view angle, constant current type driver having THD<10%, including all fixing arrengment like clamps, nuts, bolts, washers, 35W LED rod lamp (havng PF>0.9, input voltage 90-300V, IP-66, LM80) with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable with all necessary staging, etc.including bracket complete all as specified and as directed
M/S BHATT TRADERS (BID ID -3454018)
M/S PARSHOTAM KUMAR GUPTA (BID ID -3455914)
MEELU ENTERPRISES (BID ID -3449874)
NATIONAL TRADING COMPANY (BID ID -3455456)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.46 MB
TENDER70.pdf
Tender Documents • 1.32 MB
BOQ_819926.xls
BOQ • 4.89 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .