Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.0 LAccepted-AOC 482 GALI NO 4 TULSI VIHAR AZAD NAGAR HISAR 125001 | HISAR | HISAR | HARYANA | 125001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹35.6 L+₹1.6 L (4.62%)Rejected-Finance A 249 1ST FLOOR TODAY BLOSSOM 1 SEC 47 GURUGRAM | GURUGRAM | GURUGRAM | HARYANA | L2 | Rejected-Finance L2 | |
| 3 | L3₹40.1 L+₹6.1 L (17.8%)Rejected-Finance NA | NA | NA | 121004 | L3 | Rejected-Finance L3 |
Tender Value
Refer Docs
EMD Value
₹61,920
Closing Date
25 Mar 2021, 5:00 pmClosed
R. Nagender Singh
XEN (E) Rewari
Construction of Sports Stadium in village Surheli in Distt. Rewari (Pdg. E.I. internal and 30 KVA DG set only)
2021_HRY_155050_3
PWD/Rewari/jan20
Open Tender
Electrical Works
Works
90 days
XEN (E) Rewari
Refer DNIT
2 documents required · 2 mandatory
₹5,000
₹61,920
16 May 2022
16 Mar 2021
26 Mar 2021
16 Mar 2021
25 Mar 2021
16 Mar 2021
Amount
Wires and Cables.Suply and erection of PVC copper insulated and sheathed 2-core circular flexible wire.Size 1.50 sqmm ( 48 / 0.20mm).
Main Switches.Supply and erection of metal clad switches / B.D.Bs with rag bolts on wall or on existing angle iron board / pedestal including bonding to earth and necessary connections .Four pole change over switch 100 amp. 415 Volts,
Moulded case Circuit breakers.Supply and erection of moulded case circuit breakers on wall or on existing pedestal including bonding to earth and necessary connections. 15 amp.to 60 amp. 415 V ,10 KA 3-phase.
(K) Distrubution board with plug and socket.Supply and erection of sheet steel enclosure 2 pole / 3 pole with earth plug and socket suitable for incorporating single pole / triple pole MCB on wall / on existing pedestal complete with necessary connections etc. S.P.N. enclosure for single pole MCB 20 amp
Blanking sheet .Supply and erection of blanking sheet in existing distribution board.
(L) Miniature Circuit Breaker and Isolator.Supply and erection of miniature circuit breaker / isolator 240 /415 V in the existing distribution board including making necessary connections.SP MCB of 9 KA breaking capacity 6 amp. to 32 amp.( for TPN DB,s outgoing)
SPN MCB of 9 KA breaking capacity 6 amp. To 32 amp.
TPN MCB of 9 KA breaking capacity 40 amp. to 63 amp.
(M) Supply and erection of Fittings and Accessories. Call bell 220 / 230 volts A.C. bakelite with double coil.
Bell push with 4 metres 2-core , 0.50 sqmm (16 / 0.20 mm).PVC flexible wire.
Bakelite angle / straight button holder large size.
Supply and erection of hexagonal M.S. box 1.60 mm thick having each side 8 cms , 7.5 cms deep top covered with M.S. lid by means of screws including 10 mm dia 30 cm long mild steel rod made into suitable suspension hook and erected in RCC slab for erection of fan , the bottom covered with 3 mm thick bakelite sheet with suitable holes , painting etc. complete with all labour and material required to complete the job. .
Erection and carriage of fans.Making suitable hole in the wall upto 450 mm sweep exhaust fan including finishing the same and fixing of wire mesh duly fixed with Deodar wood frame of section 40 mm x 25 mm thick.
Pdg. and fixing of required size of deodar wood frame of section 50 mm x 32 mm for fixing exhaust fan upto 450 mm sweep.
(P) Pipe Laying.Supply and erection of pipe for wiring purposes including bends inspection boxes etc. where necessary and painting as required. Heavy guage welded conduit pipe 20 mm dia 1.60 mm thickness flushed.
Heavy guage welded conduit pipe 25 mm dia 1.60 mm thickness flushed.
Supply and erection of PVC pipe of 6 kg. pressure laid 1 metre below ground level complete including digging refilling of the trench with jointing etc. PVC pipe 120 mm dia.
PVC pipe 80 mm dia.
(Q) Earthing Earthing with GI earth pipe 4.5 m long and 40 mm dia with masonry enclosure on the top etc. as required .
Extra for using salt and charcoal / coke for pipe earth electrode as required.
Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required.
Extra for charcoal or coke and salt for G.I. Plate or copper plate earth electrode.
Pdg. and fixing 25 mm x 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode as required .
Pdg. and fixing 25 mm x 5 mm G.I. Strip on surface or in recess for connections etc. as required with all labour and material.
Pdg. and fixing 4.00 mm dia G.I.wire on surface or in recess for loop earthing as required .
Under Ground Cables. Supply and erection of under ground cable 1 metre below ground level covered with sand and bricks including necessary connections,digging and refiling of trenches. 16 Sq. mm 2 Core Ard Cable .
25 Sq. mm 3.5 Core Ard Cable
35 Sq. mm 3.5 Core Ard Cable
16 Sq. mm 4 Core Ard Cable .
Supply and erection of under ground cable ,loose in existing pipe or trenches complete with necessary connections . 16 Sq. mm 2 Core Ard Cable .
25 Sq. mm 3.5 Core Ard Cable.
35 Sq. mm 3.5 Core Ard Cable .
50 Sq. mm 3.5 Core Ard Cable
16 Sq. mm 4 Core Ard Cable .
Supply and erection of suitable compression type brass cable glands for underground Cable. 25 Sqmm to 50 Sqmm Cable 2 to 4 Core.
Street Light.Supply and erection of weather proof M.S.Box of size 20 cm x 15 cm x 10 cm. covered with 3.00 mm thick M.S.sheet hinged cover, locking arrangemrnt , housed in wall , including the cost of 1 no. 16 amp. 415 volts kit-kat and 2 nos. 63 amp. 415 volts neutral links fixed on hard wood board in the M.S.Box including painting and necessary connections .
Pedestal .Supply and erection of Godrej Almirah typeM.S.pedestal made of 50 mm x 50 mm x 6 mm angle iron frame with 3.00 mm thick M.S.sheet covering including shutters with suitable hinges and locking arrangement with Godrej type handle including round bars . The top covering should have downward overhang of 75 mm on all sides of pedestal , having two sets of water proof ventilation holes of suitable size on the sides , at top and bottom , each set containing four Nos. holes to discharge the heat produced by the current . The shutters fixed with rubber gasket of superior quality and of suitable size to make it water proof . The pedestal duly painted both inside and outside with two coats of approved paint and primary coat and its legs are embeded upto the entire depth in 1:2:4 cement concrete block , projected 75 mm all around the pedestal and 200 mm above the ground level including the cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work:- M.S.pedestal of size 600 mm wide , 750 mm high ,300 mm deep and bottom totally open , duly embeded in cement concrete block of size 750 mm x 450 mm x 200 mm above ground level duly plastered with 12 mm thick 1:4 cement plaster , having a base of size 900 mm x 600 mm x 250 mm below ground level.
(X) Miscellaneous Supply and erection of caution notice plate in three languages.
Supply and erection of shock restoration chart in glass frame
Supply and erection of aluminium lugs heavy duty including crimping etc. upto the entire satisfaction of the Engineer-in-charge of the work.16 sqmm .
PVC Insulated wiring in recessed conduit. Wiring in 1.5 sq.mm PVC Insulated copper conductor cable in 1.6 mm thick conduit pipe. Fan Point - Medium Point .
Long Point .
Light point.Short Point
Medium Point .
Long Point .
Twin control light point with 2 way 5 amp. single pole switch. Long point.
Call bell point including M.S box of size 180 mmX100 mmX 60 mm deep for Call bell . Long point
3 pin 5 amp. plug point including earthing the 3rd. pin etc.Short point.
Long point.
3 pin 15 amp. plug point including earthing the 3rd. pin etc. with 4 sq mm PVC insulated copper conductor cable. Long point.
Supply and erection of PVC unsheathed copper conductor cable single core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe. Size 1.5 sqmm (3 / 0.81mm).
Size 4 sqmm (7 / 0.85mm).
Size 6 sqmm ( 7 / 1.05mm).
Supply and erection of double door sheet steel enclosures distribution boards suitable for MCBs and ELCBs etc. recessed in wall including bonding to earth with all labour and material requared complete the job in all respect upto the entire satisfaction of the Engineer-in Charge of the work. 4 way SP&N (Horizontal)
4 way TP&N (Horizontal) (8 + 12)
4 way TP&N (Vertical) (8 + 12)
Supply and erection of PVC conduit pipe ISI marked (Medium) recessed in wall / ceiling etc. including cost of PVC bends, inspection box and all other material required to complete the job in all respect to the entire satisfaction of Engineer-in-Charge of work.25 mm dia
Supply and erection of MS sadles and clamps on wall / RCC parapit for fixing underground cable at distance of 0.60 metre centre to centre fixed by means of rawl plug including the cost of all labour and material required to complete the job in all respect.
Supply & erection of Socket size rotary step type Electronic regulator for A.C. ceiling fan Anchor make Delux model No. 50440 ISI / SSK make PC 561 operated on 120/280 V A.C. Supply complete including cutting of existing Bakelite sheet and making necessary connection etc. up to the entire satisfaction of the Engineer-in-Charge of the Work.
S/E of ISI mark double walled corrugated (DWC) HDPE pipe laid 1 mtr. Below ground level including diging and refilling of earth including cost of suitable size socket/cuppler for HDPE pipe including the cost of labour and material required to complete the job in all respect upto the entire satisfaction of Engineer-In- Charge of the work. HDPE pipe 63/50 mm outer dia/ inner dia.
S/E of Hot Dip Galvanized octagonal pole of 3 mm thickness, with base plate including cost of nut and bolts and all accessories as supplied by the manufacture including cost of foundation accessories etc. the foundation bolts as per manufacturer design should be hot dipped galvanized pole complete with door locking arrangement, Terminal plate consisting of 2 nos. 100 A, 4 pole natural links inclding connection etc. with suitable connecting arrangement for 2 nos. MCBs/ kit- kat including cost of RCC 1:1.5:3 for foundation of size 0.7 m x 0.7 m x 1.8 m with minimum 8 nos. 12 mm dia longitudinal MS reinforcement rods with rings of 8 mm dia not more than 200 mm C.C. for fixing the pole with all labour & material required to complete the job in all respect upto the entire satisfaction of Engineer - In - Charge of the work.8 Mtr. Long pole with top dia 70 mm and bottom dia 135 mm with base plate of size 225 x 225 x 16 mm
Supply and erection of moulded case circuit brecaker single pole/ 4 pole on wall/ on existing pedestal including bounding to earth and making necessary connection required to complete the job the job in all respect up to the entire satisfaction of the Engineer -in - Charge of the work.4 pole MCCB 200 amp.
Supply, installation, testing and commissioning of 16 mtr. long High Mast manufactured from B.S.E.N. 10025 or equivalent grade material in, 2 (two) section hot dip, galvanized inside and outside in single dip, suitable for wind velocity as per IS 875 Part-3 suitable for 9/12 nos. luminaire loading fully motorized (power tool) with starter & cable complete along with standard accessories supplied by the manufacturer with 3 nos. steel wire rope double drum system and twin dome aviation light with LED without foundation but including cost of set of foundation nut and bolts, installation at site complete in all respect upto entire satisfaction of Engineer -in-Charge. Thickness of Top Section = 3 mm (Minimum). Bottom Section = 4 mm (Minimum).Top Dia = 150 mmBottom Dia = 410mm,Thickness of Galvanization Top = 65 micron (Min.).Bottom = 85 micron (Min.)
Supply and erection of 80 watts LED flood light energy saving long life execlusive innovative die cast aluminum flood light with high power LEDs as light source suitable for highlighting with all labour and material required to complete the job in all respect upto entire satisfaction of Engineer - In- Charge Make: Havell's/ Bajaj/ Crompton / Phillips / Jaquar.
Supply and erection of 200 watts LED flood light energy saving long life execlusive innovative die cast aluminum flood light with high power LEDs as light source suitable for highlighting with all labour and material required to complete the job in all respect upto entire satisfaction of Engineer - In- Charge Make: Havell's/ Bajaj/ Crompton / Phillips / Jaquar.
S/E of integral LED street light luminaire 70 /72W of with lense suitable for 50 OD pipe ingress protection IP 65/66 and accessories required to complete the job in all respect including erection of existing pole/ bracket upto 7 mtr. high including connection of the same upto the entire satisfaction of Engineer - in - Charge of work.Make: Havell's/ Bajaj/ Crompton / Phillips / Jaquar
Supply and erection of Celing Fans 1200mm / 48" Size complete in all respect upto the entire satisfaction of the Engineer- in -Charge of work Make Crompton Greaves/ Bajaj / Orient/ Usha.
Supply and erection of 2*2 LED panel 80 watts with all labour and material required to complete the job in all respect upto entire satisfaction of Engineer - In- Charge Make: Havell's/ Bajaj/ Crompton / Phillips / Jaquar.
Supply and erection of LED fitting 18/20w. complete in all respect upto the entire satisfaction of the Engineer- in -Charge of work Make Crompton Greaves/ Bajaj / Jaquar/ Surya/ Impulse / Havells.
Supply and erection of Exhaust Fan 12'' complete in all respect upto the entire satisfaction of the Engineer -in-charge of the work Make Crompton Greaves/ Bajaj / Orient/ Usha.
Supply and erection of Air circulator wall fan 24" complete with in all respect Make Crompton Greaves/ Bajaj / Orient/ Usha/ Havells.
Supply and erection of single arm bracket made of 50 mm dia G.I pipe B class ISI 1.5 mtr. long with 25 mm dia G.I. bottom pipe with 75 mm dia 60 cm. long G.I. collar pipe, top covered with ornamental cap duly welded, painted 2 coats of aluminium paint on bracket and golden paint on ornamental cap including erection of same with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In - charge of work.Single G.I. Bracket
Double G.I. Bracket
Earth work in excavation in fundations, trenches, etc in all kinds of soils, not exceeding 2 Meter depth including dressing of bottom and sides of trenches, stacking the excavated soil, clear from the edge of excavation and subsquent filling around masonry in 15 cm layers with compaction, including disposal of all surplus soil as directed with a lead of 30 metes.
Cement lime concrete 1:8:16 with brick blast 40mm nominal size in foundation and plinth.
Cement concrete 1:2:4 with slone aggregate 20mm nominal size in foundation and plinth.
First Class bricks work laid in cement sand mortar 1:6 in foundation and plinth
11:43 cm thick bricks wall laid in cement sand mortar 1:4 without rainforecement, in foundation and plinth.
Conglomerte floor 50 mm thick CC topping 1:2:4
12 mm thick cement plaster 1:6
Cost of RCC foundation of suitable size for 16 mtr. High Mast Completed in all respect.
JMD ELECTRICALS
kunwar electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .