Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.5 LAccepted-AOC 4 28 VIVEK NAGAR KOLKATA 700075 | KOLKATA | KOLKATA | WEST BENGAL | 700075 | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹5.9 L+₹41,074 (7.42%)Rejected-Finance 49 1 ISWAR GUPTA ROAD KOLKATA 700006 | KOLKATA | KOLKATA | WEST BENGAL | 700006 | L2 | Rejected-Finance 2nd lowest bidder | |
| 3 | L3₹7.3 L+₹1.7 L (31.5%)Rejected-Finance MASAT HARIPUR RD VILL P O HARIPUR HOOGHLY | HARIPUR | HOOGHLY | WEST BENGAL | 712701 | L3 | Rejected-Finance 3rd lowest bidder | |
| 4 | L4₹7.6 L+₹2.0 L (36.9%)Rejected-Finance 59 4 23 TANTI PARA LANE HOWRAH PIN 711104 | HOWRAH | HOWRAH | WEST BENGAL | 711104 | L4 | Rejected-Finance 4th lowest bidder | |
| 5 | Rejected-Technical 24C GOABAGAN LANE KOLKATA 700 006 | KOLKATA | KOLKATA | WEST BENGAL | 700006 | - | Rejected-Technical Disqualified in technical evaluation |
Tender Value
Refer Docs
EMD Value
₹17,065
Closing Date
4 Dec 2021, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE_I, Kolkata South Health El. Divn., P.W.Dte
75 D H Road Kidderpore Kol_23
Renovation and Repairing of Electrical Installation Work at basement of new Casualty Building for setting up of store to cope up with the upcoming 3rd wave of COVID pandemic at Sambhu Nath Pandit Hospital Kolkata.
2021_WBPWD_349076_1
WBPWD/KSHED/Q39/21-22
Open Tender
ELECTRICAL WORKS ORG
Item Rate
Kolkata
Please refer Tender documents.
2 documents required · 2 mandatory
₹17,065
O/o Exe. Engr, KSHED, P.W.Dte
4 May 2023
1 Nov 2021
6 Dec 2021
1 Nov 2021
4 Dec 2021
16 Nov 2021
16 Nov 2021
120 days
Amount
Supply & Installation of 415V., 50 Hz, wall mounted, industrial type, LT Panel Board with following accessories made out of 14 SWG (BBC) & 16 SWG (Cable end boxes) CRCA shet on MS frame structure made out of MS angle (30 x 30 x 5 mm) & MS flat (30 x 5 mm). The main connection & interconnections to switches are of suitable size & capacity of wires with colour sleeves. Paint shade should be RAL 7032 both inside and outside. Continuous Earth bus of size 40 x 6 mm to be provided at a height of 150 mm from the bottom and brought outside of the panel of 75 mm length.
INCOMER
a) 415V, 160A TPN SFU in SS enclosure with 3 nos. 160A HRC Fuse (minimum 80kA) having blown fuse indication and with following MFM & CTs. [Make :- L&T/ ABB/ Schneider/ Legrand] Complete Set -- 1 No.
i) Digital Multifunction Meter (class 0.5) capable of display of Current, Volt, KWH, PF, MD with date & time stamp etc. - 1 no
ii) CT's for metering; CL:0.5, 160/5A, 5VA, tape wound (Make- Kappa) for all three phases
BUSBAR
S&F Busbar Chamber having with 99.9% - 99.5% electrolytic tinned copper 4 nos bar of size 40 mm x 5 mm mounted on non-hygroscopic porcelain insulator / hylam sheet having sufficient di-electric strength duly wrapped with colour PVC tapes (Red, yellow, blue & black) for phases & neutral identification & all connection made with required size cu bars - 1set.
OUTGOING:-
a) 415V 125A TPN SFU in SS enclosure with 3 nos. 125A HRC Fuse (minimum 80kA) having blown fuse indication. [Make :- L&T/ ABB/ Schneider/ Legrand] Complete Set --- 2 Nos.
b) 415V 63A TPN SFU in SS enclosure with 3 nos. 63A HRC Fuse (minimum 80kA) having blown fuse indication. [Make :- L&T/ ABB/ Schneider/ Legrand] Complete Set --- 2 Nos.
INDICATORS: 3 nos LED R, Y, B indicators (Siemens) with 3 nos 6A SPMCB
SAFETY: EI Danger board.
Supply & Laying 1.1KV gr. 4 Core 50 mm² XLPE Ar./Al. Cable with 2 nos. 10 SWG G.I. Wire On wall surface by MS saddle as to G.S incl. making connections as per direction of E.I.C. (from existing Panel to Floor VTPNDB ) (Make: Havells / Polycab /Universal)
Supply & Laying 1.1KV gr. 4 Core 16 mm² XLPE Ar./Al. Cable with 2 nos. 10 SWG G.I. Wire On Wall Surface incl. S&F MS saddle as to G.S. incl. making connections as per direction of E.I.C. (from VTPN DB to 4-way PDB) (Make: Havells / Polycab / Gloster / Universal)
S & Fixing of compression type brass cable gland including end finishing of the following size cables :-
4 Core 50 mm² XLPE Ar./Al. Cable
4 Core 16 mm² XLPE Ar./Al. Cable
S & F 8-Way Double Door vertical TPN MCB PDB (IP 42/43 Protection) comprising with 1 No. 415V, 125A 4-Pole MCCB (36 KA), 2 Nos. 32 A (10 KA, 'C' Curve) TPMCB & 6 Nos. 63 A TP MCB, 2 nos. cable end boxes, DIN rail, N&E Bar, Spreader links, internal connections and other accessories, on wall with MS frame, including earthing attachment as per direction of EIC. (Make - Legrand, / ABB Elegance /Schneider)
S & F 4-Way Double Door horizontal TPN MCB PDB (IP 42/43 Protection) comprising with 1 No. 415V, 63A. 4-Pole Isolator,12 nos. 240 V, 16-32 A. SP MCB(10 KA, 'C' Curve), DIN rail, N&E Bar, internal connections and other accessories, on wall with MS frame, including earthing attachment as per direction of EIC. (Make - Legrand / Schneider/ABB Elegance)
S & Fixing of Double Door Type SPN MCB DB (IP 42/43 Protection) DIN rail, N&E Bar, internal connections and other accessories, on wall with MS frame, including earthing attachment as per direction of EIC. as follows:- (Make - Legrand, / ABB Elegance / Schneider)
2+14 Way SPN MCB PDB comprising with 1 No. 240V., 63A. DP Isolator as incoming and 14 nos. 6/16A. SP MCB (10 KA-'C' Curve) as outgoing.
2+10 Way SPN MCB PDB comprising with 1 No. 250V., 63A. DP Isolator as incoming and 10 nos. 6/16 A. SP MCB (10 KA-'C' Curve) as outgoing.
Distribution wiring in 1.1 KV grade 3 x 1.5 sq mm S/C stranded 'FRLS' PVC insulated & unsheathed copper wire (Finolex / Havells / Polycab) partly in 19mm dia 3mm thick polythene pipe embeded in wall for vertical portion & in 20mm dia PVC Rigid conduit for ceiling & horizontal run on wall to light/fan points complete with 6A Piano Key type Switch (Anchor) fixed on 16 SWG M.S. Box with 3mm thick Bakelite top cover and 3 nos. suitable size cu connecting bars (P, N & E) on double bakelite insulation chairs duly fixed inside the switch board flushed in wall with earthing attachment & mending good damages to original finish as to GS. [Avg. Run 10 Mtrs]
S & F 240V., 6A. 5 Pin Plug Socket without Top and Piano Key switch (Anchor) on Board as per direction of E.I.C.
S & F following sizes 16 SWG M.S. Box complete with 3mm thick Bakelite top cover, 3 nos. suitable size cu connecting bars (P,N, & E) each on double bakelite insulation chairs on wall with earthing attachment including S & F electrical accessories (All are Anchor Make) & making necesary connection as required.
175mm X 125mm X 65mm comprising with 1 No. 240V 6 pin 20A plug socket with 1No. 20A piano key switch.
150mm X 100mm X 65mm comprising with 2 Nos. 240 V 5 pin 6A plug socket with 2 Nos. 6A piano key switch.
240mm X 200mm X 65mm comprising with 1 No. 240 V 6 pin 20A plug socket with 1No. 20A piano key switch, 3 nos. 250V 6A 5 Pin plug socket with 3 nos. 6A Piano Key switch & 1 No. Indicator.
S & Drawing following sizes S/C stranded 'FRLS' PVC insulated & unsheathed copper wire (Make Finolex / Havells / Polycab) in 20 mm dia PVC rigid conduit (Precision, MMS, FR) on wall as to G.S. :-
Finishing the end of following sizes copper wire end with dowells solderless socket by crimping method as per GS :-
S & Fixing of 240V AC Superior type Call Bell (Anchor) on T.W. Board incl. S & F T.W. Board and making connection as to G.S.
S & Fixing of 240 V, 100 Watt Step type Electronic Fan Regulator (Make - Anchor) after making housing on the switch board.
S & Fixing of 240 V 1200 mm (48") sweep A.C. ceiling fan without regulator incl. down rod, canopy & fan blades etc. complete set and engraving & Painting the Departmental Number upto 15 digit on Fan Body and making necessary interconnection as required. [Make: Crompton HS Plus or HB Plus / Orient Energy star (wood finish) / USHA Striker Plus]
S & Fixing of 240 V Single LED fittings made of minimum 22 SWG sheet and fittings cover must be fixed with 2 nos. screws, incl. 1 no 18 /20 Watt LED Tube lamp. [Philips, Cat no.TMC 501 P 1xT LED, Master LED tube, model no. 18W 865 T8 I 2100 lm / Wipro Cat no. WIO921208, LED tube LL13-181-65SE] suspended 25 cm below the ceiling by nos. 20 mm dia E.I. conduit (14 SWG) support with MS clamp and necessary connection by 2x1.5 sq.mm. PVC insulated copper wire and painting.
S & Fixing of 240V Twin LED fittings made of minimum 22 SWG sheet and fittings cover must be fixed with 2 nos. screws incl. 2 nos 18/20 Watt LED Tube lamp. [Philips, Cat no. TMC 501 P 2 x TLED, Master LED tube, model no. 18W 865 T8 I 2100 lm, Wipro, Cat no. WIO 92 2208, LED tube LL13-181-65SE] suspended 25 cm below the ceiling by nos. 20 mm dia E.I. conduit (14 SWG) support with MS clamp and necessary connection by 2x1.5 sq.mm. PVC insulated copper wire and painting.
S & F 18 Watt LED Tube lamp (Philips, Cat No. Master LED tube, 18W 865 T8 I 2100 lumens) in place of damaged tube light.
S & Fixing Extra 14 SWG E.I. Conduit for suspension of FTL fittings exceeding 25 cm with addl. 2x20 mm dia. E.I. Conduit supports & necessary connection by 2 x 1.5 Sq. mm. S/C PVC Cu. Wire, painting etc. as per GS.
S & Fixing Extra fan down rod (14 SWG) with connecting wire for hanging the fans with S&F of Hevy type insulaters, Nuts, bolts, Washers, Split pins etc. & necessary inter-connection as per the direction of EIC.
Supply of 230V, 18" (450mm) 4 (four) Blades (whole metal body with metal blade) Industrial type Bracket Fan complete with assembling all accessories of motor shaft, blade & cage guard with S/F of 100mm long 10mm dia anchor fastners & other fixing materials and making connection. (Make - E.P.C. Electrical Pvt. Ltd., Heavy Duty)
Supply of 230 V., 18" (450mm) 4 (four) Blades Industrial type Air-Circulator Pedestal Fan (whole metal body and metal blade) complete with all accessories such as Regulator, Cord and 15 Amp. 3-pin Top (Make - E.P.C. Electrical Pvt. Ltd., Heavy Duty)
S & F 415 V. single timer controlled starter assembled in S.S. enclosure of 2+14 way double door SPNDB comprising with 1 no 63A 4P MCB, 1 no. 32A TP power Contractor (Eq to MNX 40) , 2NO+2NC auxiliary contact, 1 no. 24 hrs. digital timer (Eq. to T2DDT7), 1 no Auto-Off-manual switch, 1 no 10A single way switch, 1 no. Indicating lamp & 1 no 6A SP MCB incl. front locking arrangement, internal wiring & earthing attachment as per direction of EIC. (Make - L&T /ABB /Legrand/ Schneider)
S & F 240 V. single timer controlled starter assembled in S.S. enclosure of 2+14 way double door SPNDB comprising with 1 no 63A DP MCB, 1 no. 2 Moduler AC motor starter (Legrand/Myrius Cat no 673031), 1 no. 32A TP power Contractor (Eq to MNX 40) , 2NO+2NC auxiliary contact, 1 no. 24 hrs. digital timer (Eq. to T2DDT7), 1 no Auto-Off-manual switch, 1 no 10A single way switch, 1 no. Indicating lamp & 1 no 6A SP MCB incl. front locking arrangement, internal wiring & earthing attachment as per direction of EIC. (Make - L&T /ABB /Legrand/ Schneider)
Connecting the equipments to earth busbar incl. S & Drawing No. 6 SWG G.I. earth wire as to G.S.
S & F Earth bus-bar of 25 mm x 6 mm GI flat on wall with drilled holes, double nut-bolts & washers etc. as to GS.
Earthing installation with 50mm dia, 3.04 m long G.I. pipe (TATA-M) for soft soil including excavation of earth & ramming properly as per G.S.
Cost of Dismantling the existing Cubicle type floor mounted LT panel after disconnecting all cables & retermination of incoming cable, the main source, to the new panel including S & F necessary electrical assessories, rerouting of cable with required man power and arrangements of tools and tackles and the old panel has to be deposited to sectional store / to be stacked at any safe place carefully as per direction of EIC.
Special Terms and Conditions 1. It is stated that the above work place is existing COVID Hospital and in some areas inside COVID ward. In case of any mishap or accidental to any staff that deputed by the agency the whole responsibility is to be borne by the concern agency. 2. The Agency shall be responsible for provisioning of all COVID safety measures including regular sanitization of work places, vaccination of employees and compliance of stated directive and COVID appropriate norms. 3. All the issues related to the safety of the staffs should be taken care by the agnecy itself.
Defect Liability period 1 (One) Year
Electromech Engineers Co-Operative Society Ltd.
GHANASHYAM ELECTRIC STORES
RUBY ENTERPRISE
technical_671611.pdf
PDF • 0.08 MB
techsummary_671611.pdf
PDF • 0.09 MB
finance_671611.pdf
PDF • 0.08 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_671611.pdf
PDF • 0.08 MB
AOC0001.pdf
PDF • 0.55 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .