Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹85.4 LAccepted-AOC FLAT NO 151 BLOCK NO 1 DIAMOND SQUARE CGHS LTD PLOT NO 13A SECTOR 6 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | L1 | Accepted-AOC Accepted being lowest quoted tenderer | |
| 2 | L2₹96.7 L+₹7.0 L (7.82%)Rejected-AOC WZ 1000 NANGAL RAYA PANKHA ROAD SOUTH WEST DELHI DELHI 110046 | DELHI | SOUTH WEST DELHI | DELHI | 110046 | L2 | Rejected-AOC Rejected being other than lowest quoted tenderer | |
| 3 | L3₹1.0 Cr+₹14.0 L (15.6%)Rejected-AOC | L3 | Rejected-AOC Rejected being other than lowest quoted tenderer | |
| 4 | L4₹1.5 Cr+₹62.4 L (69.5%)Rejected-AOC | L4 | Rejected-AOC Rejected being other than lowest quoted tenderer | |
| 5 | Rejected-Technical NH 17 MAIN ROAD BINAGA BAZAR KARWAR 581307 | KARWAR | UTTARA KANNADA | KARNATAKA | 581307 | - | Rejected-Technical Rejected due to being two class below |
| Sl No | Description | Qty | Unit | mayur enterprises L2 | M/s Sohanil Construction L3 | SHREE Glass and Plywood L4 | BRIJ MOHAN LAL AND CO. L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Repair/Servicing to Power Transformer of 5MVA capacity complete all as specified and as directed.by using suitable Crane on to the Transporting Trolley Vehicle, Transporting the unserviceable Transformer on Trolley Vehicle to civil Workshop Naini industrial area and after completion of Repairs at Workshop, Transporting the serviceable Transformer on Trolley Vehicle to 33 KV MRS Yard and unloading and placing it on the Transformer Foundation carefully complete all as specified and as directed.
[i] Draining out transformer oil in the suitable capacity of tanker / drums, old burnt oil is not allowed to reuse, old burnt oil to be replaced with new oil.
[ii] Lifting, transporting & handling the transformer to the work shop and opening top cover of the transformer by unscrewing nuts / bolts / washers etc. including disconnecting core assembly from HV / LV bushing and lifting the same gently with the help of EOT crane and taking out from the shell [Container / Body] of the transformer.
[iii] Visual inspection of entire Core Assembly, Transformer Tank, Core Limbs, OLTC etc., locating the fault / damages.
[iv] Cleaning the transformer body from inside, removing deposited dirt / sludge / foreign particles etc. from the bottom / body of the transformer, cleaning and drying up the shell from inside before refilling with the new Transformer Oil. | 1 | Each Job | 1,00,000 ₹1,00,000 | 20,000 ₹20,000 Lowest | 1,10,000 ₹1,10,000 | 40,000 ₹40,000 |
| 1.01[v] Cleaning and washing thoroughly core and serviceable windings of the transformer by hosing down with clean dry hot oil conforming to IS – 336, removing deposited dirt / sludge / foreign particles from the windings / core through inspection of windings, providing insulations to leads and terminals complete and re-assembling the core including newly winded coils etc. [vi] Heating / drying / baking complete carefully and thoroughly inside the heating chamber at suitable temperature to obtain required value of insulation resistance etc all as per IS. [vii] Lifting and refixing core assembly inside the transformer shell gently and carefully connecting Primary / Secondary / Neutral Terminal Connections to the bushings assembly, fixing of Tap changer including tightening of nuts, bolts, washers of the core to reduce humming noise. [viii] Refilling the filtered new transformer oil in to the transformer complete. [ix] Refixing the top cover including replacement of Cork Sheet / Gasket 8 mm thick tightening of nuts / bolts / washers etc. and replacement of Breather with new blue Silica Gel. | |||||||
| 1.02[x] The inspection of transformer shall involve Checking of all clamps, nuts, bolts including core bolts & cover fixing bolts, Checking all brazing, joints, Tap heads and connection joints, Checking all jumpers, terminations / connections inside the transformer and Checking the Bulcholtz Relay / Conservator MOG if any. Note:- [a] Cranes used for Loading, Unloading of Transformer on to the Transporting Trolley Vehicle. [b] Any damage to insulators / bushes / windings etc. while in the custody of the contractor shall be made good at no extra cost to the Government. The serviceability of the transformer shall be checked and confirmed by the contractor before taking into his custody. [c] The rate quoted shall be deemed to be include for necessary new nuts, bolts, washers, gasket all as per existing etc. [d] Supply of New Transformer Oil & filteration will be measured separately. [e] Supply of Silicagel & breather assembly HT bushing etc will be measured separately. (f) All labour cost are included in this item. | |||||||
| 2.00 | M&L for spray Painting of Power Transformer of capacity 5 MVA complete with Two Coats of Synthetic enamel paint externally on the Transformer including cleaning , scrubing & dusting, complete all as specified and as directed. | 2 | Each Job | 22,000 ₹44,000 | 1,500 ₹3,000 Lowest | 18,000 ₹36,000 | 15,000 ₹30,000 |
| 3.00 | Supply only HV Bushings (Primary side) made out Porcelain alongwith Brass/Copper bushing rod 33 KV and suitable length/size all as per existing, capacity distribution transformers of 5 MVA size, including dismantling old one, complete all as specified and as directed. | 3 | Each | 7,300 ₹21,900 | 1,400 ₹4,200 Lowest | 8,400 ₹25,200 | 6,000 ₹18,000 |
| 4.00 | Supply only HV Bushing (Secondary side) alongwith Brass/Copper bushing rod 11 KV with threading and suitable length/size all as per existing etc, complete the following capacity power transformers of Size 5MVA ,all as directed including dismantling old one, complete all as specified and as directed. | 3 | Each | 4,000 ₹12,000 | 1,400 ₹4,200 Lowest | 7,800 ₹23,400 | 4,500 ₹13,500 |
| 5.00 | S&F butterfly valve for radiatior suitable size all as per existing etc, complete for power transformers of any make/size/type all as directed including dismantling old one, complete all as specified and as directed. | 2 | Each | 2,250 ₹4,500 | 3,500 ₹7,000 | 1,250 ₹2,500 Lowest | 2,000 ₹4,000 |
| 6.00 | S&F WTI (Winding Tempreture Indicator) for any capacity Power Transformer suitable size all as per existing etc, complete of any make/size/type all as directed including dismantling old one, complete all as specified and as directed. | 1 | Each | 12,700 ₹12,700 | 72,000 ₹72,000 | 14,950 ₹14,950 | 12,000 ₹12,000 Lowest |
| 7.00 | S&F OTI (Oil Tempreture Indicator) for any capacity Power Transformer suitable size all as per existing etc, complete of any make/size/type all as directed including dismantling old one, complete all as specified and as directed. | 1 | Each | 11,600 ₹11,600 | 2,500 ₹2,500 Lowest | 14,950 ₹14,950 | 12,000 ₹12,000 |
| 8.00 | S&F SRC Gaskit for any capacity Power Transformer suitable size all as per existing etc, complete of any make/size/type all as directed including dismantling old one, complete all as specified and as directed. | 1 | Each Set | 42,450 ₹42,450 | 1,500 ₹1,500 Lowest | 3,500 ₹3,500 | 40,000 ₹40,000 |
Tender Value
₹1.1 Cr
EMD Value
₹1.9 L
Closing Date
4 Sept 2025, 6:00 pmClosed
HQ CWE Prayagraj
HQ CWE New Cantt Prayagraj
REPAIR/MAINT OF HT SWITCH GEAR, TRANSFORMERS, LIGHTING ARRESTER INSULATOR, HT JOINTS AND CONNECTED WORKS AT NEW CANTT UNDER GE (WEST) PRAYAGRAJ.
2025_MES_722532_1
82001/W/E8
Open Tender
Civil Works
Item Rate
180 days
Prayagraj
Class B and Category b(ii)
6 documents required · 6 mandatory
₹1,000
GE (West) Prayagraj
₹1.9 L
Yes
10 Nov 2025
25 Jul 2025
11 Sept 2025
25 Jul 2025
4 Sept 2025
16 Aug 2025
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .