Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹31,500
Closing Date
13 Sept 2023, 9:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Public Works Department
RajesH B Tengli
Annual Maintenance to the 1 x 250 KVA, 1 x 500 KVA D.G. Sets and HT substation, Solar Water Heating System installed at Karnataka Bhavan-1 Annexe Building, Koutilya Marg, Chanakyapuri and 2 Nos of 320 KVA D.G.Sets and LT control Panels, Solar Water Heating sysem at Karnataka Bhavan-2 Sardar Patel Marg, and Karnataka Bhavan-3 Hudco Place, New Delhi.
PWD/2023-24/EL/WORK_INDENT3442
PWD/2023-24/EL/WORK_INDENT3442
Open
Electrical
Electronic Documents, First(One Cover)
PWD Electrical Division Office Bengaluru
2 documents required · 2 mandatory
₹500
₹31,500
22 Aug 2023
22 Aug 2023
30 Aug 2023
Annual Maintenance to the 1 x 250 KVA, 1 x 500 KVA D.G. Sets and HT substation, Solar Water Heating System installed at Karnataka Bhavan-1 Annexe Building, Koutilya Marg, Chanakyapuri and 2 Nos of 320 KVA D.G.Sets and LT control Panels, Solar Water Heating sysem at Karnataka Bhavan-2 Sardar Patel Marg, and Karnataka Bhavan-3 Hudco Place, New Delhi.
Supplying of 15/40 multi grade Engine lubricating oil (AQR)
Supplying and filling of distilled water for batteries (AQR)
Supplying and filling of radiator water coolant solution for DG Set (AQR)
Supplying and fixing of radiator drive belts for DG Sets (AQR)
a) 500 KVA DG Set
Supplying and fixing of radiator drive belts for DG Sets (AQR) b) 250 KVA DG Set
Supplying of petroleum jelly
Supplying and installation of electronic timer for start, stop running time delay and start failure for DG Set (AQR)
Supplying and supply of bearing grease
Charges for caliberation of fuel pumps of
a) 500 KVA DG Set (AQR)
Charges for caliberation of fuel pumps of b) 250 KVA DG Set
Charges for caliberation of fuel injectors of a) 500 KVA Set (AQR)
Charges for caliberation of fuel injectors of b) 250 KVA DG Set
Charges for servicing of Diesel Engine for replacement of following items such as old oil from crank case, cleaning of crank case, cleaning and engine, changing of lube oil filters, fuel, filters incl...
Charges for servicing of Diesel Engine for replacement of following items such as old oil from crank case, cleaning of crank case, cleaning and engine, changing of lube oil filters, fuel, filters incl...
Charges for servicing and lubrication of Alternator (AQR)
a) 500 KVA DG Set
Charges for servicing and lubrication of Alternator (AQR) b) 250 KVA DG Set
Charges for servicing of air circuit breakers of following: cleaning of ACB arcing contacts, main contactors / arc cuts, testing of manual spring change motor, assembly testing of triping coils and lu...
Charges for servicing of air circuit breakers of following: cleaning of ACB arcing contacts, main contactors / arc cuts, testing of manual spring change motor, assembly testing of triping coils and lu...
Charges for servicing of air circuit breakers of following: cleaning of ACB arcing contacts, main contactors / arc cuts, testing of manual spring change motor, assembly testing of triping coils and lu...
Charges for servicing and maintenance of 1000KVA Compact HT substation for the following items such as a) Three way 11 KV, 20kA for 3 sec Non extensible compact ring mai...
Charges for servicing with replacing of carbon brushes to self starter for DG sets(AQR)
500 KVA DG Set. 1 time in a year.
Charges for servicing with replacing of carbon brushes to self starter for DG sets(AQR) 250 Kva DG set. 1 time in a year.
Charges for servicing of auxillary contactor, relay, timer testing of connections of all contactor, relays timers and general check up of control circuit of announciation panel, periodical maintenance...
Charges for servicing of auxillary contactor, relay, timer testing of connections of all contactor, relays timers and general check up of control circuit of announciation panel, periodical maintenance...
Servicing of MCCB with control contacts operating mechanism and termination etc, main panel periodical maintenance for every six months (AQR) 630A capacity 3 pole MCCB as per manufacturers standards...
Servicing of MCCB with control contacts operating mechanism and termination etc, main panel periodical maintenance for every six months (AQR) 430A capacity 3 pole MCCB as per manufacturers standards...
Servicing of MCCB with control contacts operating mechanism and termination etc, main panel periodical maintenance for every six months (AQR) 250A to 100A capacity 3 pole MCCB as per manufacturers st...
Supply and Fixing of water temperature safety switch, it includes cost of all materials, lead lift and transportation etc. The work should be carried out as per the direction of the Engineer in Charg...
Supply and Fixing of water temperature safety switch, it includes cost of all materials, lead lift and transportation etc. The work should be carried out as per the direction of the Engineer in Charg...
Supply and Fixing of lube oil pressure safety switch, it includes cost of all materials, lead lift and transportation etc. The work should be carried out as per the direction of the Engineer in Char...
Supply and Fixing of lube oil pressure safety switch, it includes cost of all materials, lead lift and transportation etc. The work should be carried out as per the direction of the Engineer in Char...
Supply and Fixing of coolant water sensor, it includes cost of all materials, lead lift and transportation etc. The work should be carried out as per the direction of the Engineer in Charge of the wor...
Supply and Fixing of coolant water sensor, it includes cost of all materials, lead lift and transportation etc. The work should be carried out as per the direction of the Engineer in Charge of the wor...
Supply and Fixing of Diode Kit for Alternators , it includes cost of all materials, lead lift and transportation etc. The work should be carried out as per the direction of the Engineer in Charge of ...
Supply and Fixing of Diode Kit for Alternators , it includes cost of all materials, lead lift and transportation etc. The work should be carried out as per the direction of the Engineer in Charge of ...
Supplying, fixing and wiring 3 phase Digital Ammeter/ Voltmeter (48/6.27)
Solar- Annual Maintenance of the 500Ltrs 8nos Solar Water Heaters. The systems require periodic inspections and routine maintenance to keep them operating efficiently.Routine maintenance Look for dama...
Supplying and fixing of Pressure release valve for the above 500 ltrs tank suitable for 1/4 5.5 K.G pressure @ 80 degree temperature complete including the removing the damaged one from the tank. For...
Supplying and fixing of Air release valve for the above 500 ltrs tank suitable for 1/2 connection outlet (ID) complete including the removing the damaged one from the tank.For Karnataka Bhavan-1 Annex...
Supplying and fixing of Hose pipe for the above tank suitable for steam, PRD 25mm dia of 600 mm length with end fitting of 3/4 Check nut(ID) including removing the damaged one from the tank and re-fix...
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
High Court Letter FF-40 Air Condtioner.docx
Tender Document • 0.06 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .