Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.2 LAccepted-AOC 32 FATEH ENCLAVE OFFICERS ENCLAVE PHASE II PATIALA 147001 PB | PATIALA | PATIALA | PUNJAB | 147001 | L1 | Accepted-AOC Being Lowest Bidder | |
| 2 | L2₹36.0 L+₹25,115 (0.70%)Rejected-AOC 300 PREM BASTI 10 SANGRUR SANGRUR PUNJAB 148001 | SANGRUR | PUNJAB | 148001 | L2 | Rejected-AOC Being other than lowest bidder | |
| 3 | L3₹38.7 L+₹3.0 L (8.29%)Rejected-AOC | L3 | Rejected-AOC Being other than lowest bidder | |
| 4 | L4₹46.4 L+₹10.6 L (29.7%)Rejected-AOC H NO 597 SEONA ROAD RANJIT NAGAR PATIALA PB 147001 | PATIALA | PATIALA | PUNJAB | 147001 | L4 | Rejected-AOC Being other than lowest bidder | |
| 5 | L5₹50.7 L+₹15.0 L (41.8%)Rejected-AOC 852 EKTA VIHAR 1 C NEAR ANAND NAGAR 9 B PATIALA 147001 | PATIALA | PATIALA | PUNJAB | 147001 | L5 | Rejected-AOC Being other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
7 Oct 2024, 6:00 pmClosed
Garrison Engineer (South) Patiala
MILITARY ENGINEER SERVICES GARRISON ENGINEER SOUTH SANGRUR ROAD PATIALA CANTT
As per tender documents
2024_MES_670246_1
GE(S)/PAT/T-26/2024-25
Open Tender
Civil Works
Item Rate
240 days
Mil Stn Patiala
Refer tender documents
8 documents required · 8 mandatory
₹500
Yes
GE (South) Patiala
₹90,000
Yes
19 Nov 2024
2 Sept 2024
10 Oct 2024
2 Sept 2024
7 Oct 2024
23 Sept 2024
9 Sept 2024 - 17 Sept 2024
Amount
'Notes: (i) Please refer Schedule 'A' Notes of tender documents.
M&L for removing blockage from WC's, traps (P-trap/ floor trap/gully trap etc) inside the buildings at any floor including cleaning and flushing the pipes upto first man hole complete all as directed. Note :(i) This item includes cleaning of all the traps and pipes of toilet block/kitchen irrespective of Nos and length of pipes involved, up to first man hole and altogether shall be taken as one job for payment purpose. (ii) In case the blockage reoccurs in the same location with in the month, the same shall be cleared by the contractor at his own cost and no extra payment shall be made for the repetitive cleaning.
M&L for cleaning of blockage in existing sewage line of 100mm to 200mm dia from one manhole to next manhole and washing through in fresh water including removing all sludge from the sewage lines and disposing off sludge outside the defence land (area specified by the municipal carporation for disposal) complete all as directed. NOTE :- Cost of all T&P and transportation required is included in quoted rate and nothing extra shall be paid by the Govt.
Cleaning of blockage in existing sewage line of 300mm to 450mm dia from one manhole to next manhole and washing through in fresh water including removing all sludge from the sewage lines and disposing off sludge outside the defence land (area specified by the municipal carporation for disposal) complete all as directed. NOTE :- Cost of all T&P and transportation required is included in quoted rate and nothing extra shall be paid by the Govt.
Excavation in trenches in soft/loose soil not exceeding 1.50 metre wide and not exc. 1.5 metre in depth and getting out complete all as specified and directed.
Excavation in trenches in soft/loose soil exceeding 1.50 metre and not exceeding 3 metre depth complete all as specified and as directed.
Returning and filling including spreading, leveling , watering and well ramming in layer not exceeding 25cm thick complete all as specified and as directed.
Removing excavated spoil to a distance not exceeding 50 metre and deposting where directed at a level not exceeding 1.5 meter above the starting point complete all as specified and as directed.
M&L for cement plastering 15mm thick in cemet mortar 1:4 including mixing of liquid water proofing compound as per manufacturer's instructions on fair face of brick work or concrete surfaces or in chajjas/parapet walls etc finished even and fair without using extra cement complete all as specified and directed. Note: - Locations for use of WPC shall be given by Engineer Incharge and WPC Shall be measured and paid for separately under respective item.
Supply only integral water proofing compound complete all as specified and as directed.
M&L for PCC (1:2:4) type B-0 using 12.5mm graded crushed stone aggregate as in benching for manholes, bands , coping , bed plate etc with slightly chamfered or rounded angles including necessary form work, if any, and finishing exposed surface even and smooth without using extra cement complete all as specified and as directed.
M&L for PCC (1:4:8) type D-2 (using 40 mm graded mechanically crushed stone aggregate) as in foundation of manholes completed all as specified and directed.
M&L for reinforced concrete pipes including Demolition by breaking up drain pipes salt glazed stone ware pipe any dia jointed in cement mortar and taking out of root trenches removing the debries from site complete all as specified and as directed. of 150mm dia, class NP2, laid and jointed complete with collars and jointed complete in cement mortar (1:1)
M&L for reinforced concrete pipes including Demolition by breaking up drain pipes salt glazed stone ware pipe any dia jointed in cement mortar and taking out of root trenches removing the debries from site ,of 200 mm dia, class NP2, laid and jointed complete with collars and jointed complete in cement mortar (1:1) complete all as specified and as directed.
M&L for Reinforced concrete pipes including Demolition by breaking up drain pipes salt glazed stone ware pipe any dia jointed in cement mortar and taking out of root trenches removing the debries from site ,of 300 mm dia, class NP2, laid and jointed complete with collars and jointed complete in cement mortar (1:1) complete all as specified and as directed.
Demolition of Reinforced cement concrete of any description and manhole covers, in any position not otherwise described for complete all as directed and removal of debris outside the defence land.
M&L for RCC (1:2:4) type B-1 using 20mm graded mechanically crusted stone aggregate as in precast slabs for covers of manholes and set in CM 1:4 including necessary form work and placing of manholes cover in version complete all as specified and as directed.
S&F mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding witgh and including mild steel wire (annealed not less than 0.9 mm dia or securing with clips complete all as specified and as directed.
M&L for Cutting into existing manholes for connecting new drains of internal dia of 150mm, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required completed all as specified and diredcted.
M&L for Cutting into existing manholes for connecting new drains of internal dia of 200mm, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified and as directed.
M&L for Cutting into existing manholes for connecting new drains of internal dia of 300mm, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified and as directed.
M&L for Mild steel works as in steps, rungs, balusters, handles and other similar small article fixed independently, made to shape duly tarred and sanded conforming to Fe290 Grade E-165 complete all as specified and as directed. (PCC for filling shall be measured and paid separately.
Demolition of brick work built in cement mortar including all quoins, arches, pillars etc. complete all as specified and directed.
M&L for brickwork with sub class ‘B’ bricks, straight or curved on plan exc 6m mean radius built in built in cement mortar 1:6 complete all as specified and directed.
M&L for brickwork with sub class ‘B’ bricks, straight or curved on plan exc 6m mean radius built in built in cement mortar 1:6 but except bricks complete all as specified and directed.
M&L for Brickwork with sub class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in built in cement sand 1:4 complete all as specified.
M&L for Brickwork with sub-class ‘B’ bricks in brick-on-edge walls (less than ½ brick thick), built in cement sand 1:4 complete all as specified and as directed.
M&L for Flush pointing in CM 1:3 to brick walls laid flat or on edge incl raking out joints/ pointing built in cement mortar to existing brick work in walls or to bricks on edge/flat in floors, surface channels, roofs, etc complete all as specified and as directed.
M&L for Flush pointing in CM 1:3 to brick walls laid flat or on edge complete all as specified and as directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc complete all as specified and as directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
M&L for PCC flooring 1:3:6 using 20mm graded aggregates complete all as specified and as directed.
Taking down of eaves gutters and rain water pipes(AC Rain water pipe/SWG pipe line) of any size or pattern including all fittings etc complete all as specified and directed.
M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls of 110 mm bore of pipe etc complete all as specified and directed.
S&F PVC (SWR) junction single, (single T) equal or un equal of 110 mm bore of pipe complete all as specified and directed.
S&F PVC (SWR) bends any radius of 110 mm bore with out access door complete all as specified and directed.
Taking up or down existing GI steel tubing and connections, 15mm bore complete all as specified and as directed.
S&F 20mm (OD 22.20mm) CPVC pipes SDR 11 for potable hot and cold water supplies lead free incl all fitting suitable for fixing 15mm CP fitting & fixtures on walls/ceiling or laying in floors complete all as specified and as directed.
Taking up or down existing steel tubing and connections, 20mm bore complete all as specified and as directed.
M&L for Steel water tubing medium grade 20mm bore galvanised with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and as directed.
Refixing for labour 20mm bore GI steel water tubing medium grade with all fittings and fixed to walls and ceiling or laid in floors after cleaning, threading etc. complete all as specified and directed.
S&F 75 mm outlet dia PVC (SWR) floor trap, with CP grating including jointing to waste pipe with solvent complete all as specified and as directed.
S&F in repairs 75mm dia PVC (SWR) multi floor trap with grating including jointing with solvent cement complete all as specified and directed.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position and cleaning and removing all scale and dirt, etc form existing water storage tank of capacity exc 250 litre and n.exc 500 litre by emptying, drying and cleaning the tank by scrubbing the dust with wire brush from the tank including cleaning from mouths of circulations pipe, complete all as specified and directed. NOTE:- Float valve should be replaced without any extra cost to government.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position and cleaning and removing all scale and dirt, etc form existing water storage tank of capacity exc 500 litre and n.exc 1000 litre by emptying, drying and cleaning the tank by scrubbing the dust with wire brush from the tank including cleaning from mouths of circulations pipe, complete all as specified and directed. NOTE:- Float valve should be replaced without any extra cost to government.
S&F lid/ tank covers of any type white colour (flap/thread/lock type) as per existing pattern to existing PVC water storage tanks of capacity 250 to 1000 Ltrs complete all as specified and as directed.
M&L for cast iron nahani trap 100 mm dia with long arm n less than 450mm grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and as directed.
M&L for vitreous china premium/1st quality wash down water closet pan floor mounting (pedestal pattern/EWC) white colour including CI S/P trap as directed including connection to drain (or out going pipe) and to flushing pipe, antisyphonagee pipe,etc.,with flush pipe PVC 32mm dia and incl. plastic seat cover as recommended by manufacturer closed pattern with flat bottom etc; and incl all necessary accessories like rag bolts/gel gasket etc as recommended by manufacturer for fixing, packing and including supply and fix of PVC long arm S/P trap so that joint is avoided inside the building as well as in wall and outlet straight away come out of wall in all floors G.F. and taking down existing of any description/size complete all as specified and as directed.
M&L for vitreous china squatting pan of Orissa patten size 580 x 440 white colour including CI S/P trap long size as directed joint run and lead front or back inlet with integral footrest including connection to trap and to flushing pipe,anti-syphonage pipe, etc, fixed in repair complete and making good to floor in CM 1:3 complete all as specified and as directed.
S&F health faucet with 8mm dia and 1.2 metre long flexible tube in chorme finish and wall hook including making connections and fixed in position complete all as specified and as directed.
Dismantling, floor, hearth or wall tiling including CM(bedding (but not backing), removing serviceable tiles to store & rubbish off the premises complete in all respect as specified.
Demolition of cement concrete un -reinforced in ground floors and pavings n.exc 15cm thickness complete all as specified.
M&L for cement concrete work 1:4:8 type D-2 in sub-case to flooring etc complete all as specified and as directed.
M&L Machine pressed rubber moulded ISI marked precast cement concrete interlocking paver block any shape and size and of colour 50% red coloured tiles and 50% grey coloured tiles confirming to IS-15658-2006 of 60mm thickness M-35 Grade and including filling of interstices with fine sand over including 25mm thick layer of sand chusion complete all as specified.
M&L for 25mm thick cement concrete 1:2:4 using 12.5mm graded stone aggregates as in flooring/sub-base complete all as specified and as directed.
M&L for anti-skid ceramic joint free premium quality coloured tiles 300 X 300 mm and 6-7 mm thick, as in floors etc. in any pattern of light & dark tiles as approved, set and jointed in neat cement slurry and pointed in white or coloured cement to match, in floors etc. over & including 20 mm thick screed in cement mortar (1:4) over and pointed in white cement with pigment to match the colour of tiles complete all as specified and as directed.
M&L for ceramic glossy finish, joint free premium quality coloured tiles 600 X 300 mm and 8-9 mm thick, in any pattern of light & dark/highlighters tiles etc as approved, on vertical surfaces such as in skirting/dado etc, set and jointed in cement slurry over & including 10 mm thick rendering in cement mortar (1:4) and pointed in white cement with pigment to match the colour of tiles complete all as specified. Note : Dado should be flushed with the wall plastering.
S&F for Angular Stop Cock, CP, fency type with wall flange, fency type chromium plated cast copper alloy screwed down, high pressure, screwed ends for 15mm bore of iron pipe or for union and fixed in position complete fixed as in repair complete all as specified and as directed.
S&F Bib taps, CP, fency type long nose with wall flange screwed for 15mm bore of iron pipe or for brass ferrule and fixed in position complete fixed as in repair in all respect all as specified.
S&F Concealed Stop Cock, fancy type, CP with long shank and cup, exposed part kit with wall flange, fitting sleeve, operating lever, adjustable wall flange and including regular brass body of concealed stop cock suitable for 15mm line with protection cap fixed in position complete in all respect all as specified.
S&F overhead shower 120mm dia with 225-230mm long brass shower arm with wall flange and incl all necessary accessories as recommended by manufacturer for fixing complete in all respect all as specified.
S&F CP jet for EWC with chrome finished connction pipe including all accessories for fixing complete in all respect all as specified.
S & F Supply and fix in repair, Vitreous China Urinal, Half stall type, white including fixing plug, Cast Iron Bracket duly painted/Erecting Stand including cutting,CP 32mm flush pipe etc all fittings complete all as specified and directed.
S& F Vitreous china wash hand basin white flat back size 550 x 400 mm including PVC waste pipe 32 mm bore and CP Waste coupling with and incl a pair of suitable mild steel brackets, fixed all in repairs, including cutting for or pinning in and making good disturbed portion as reqd and removal of unserviceable material from site complete all as specified and directed.
S&F single liver basin mixer with popup waste system & 450mm long braided hoses, fency type, cast copper alloy, with capstan heads, chromium plated, screwed down, high pressure, with long screwed shanks and fly nuts, screwed for 15mm bore of iron pipe complete all as specified and directed.
S&F CP Urinal spreader for urinals and incl all necessary accessories as recommended by manufacturer for fixing complete in all respect all as specified and directed.
S& F 600 mm long PVC connection with brass nuts on both ends for 15mm bore pipes of approved quality complete ., incl taking down & removing old unserviceable PVC connection any size complete all as specified and directed.
S& F 450 mm long PVC connection with brass nuts on both ends for 15mm bore pipes of approved quality complete ., incl taking down & removing old unserviceable PVC connection any size complete all as specified and directed.
S&F 6mm thick looking mirror fixed to wall with stainless steel plugs/connecter/spacers/screws etc. chrome finish without any beading, including ends/edges of the mirror to be tapered etched smooth finish etc.complete fixed in position all as specified and directed.
S&F Flushing cistern of PVC 10 ltr. cap. with dual flushing system, valveless syphonic action type, , low level, white/ivory/off white with inlet, ball valve, float and including brackets and connection to pipe etc. and incl all necessary accessories like rag bolts/gel gasket etc as recommended by manufacturer for fixing, packing and taking down existing of any description/size complete all as specified and directed.
S & F Ball brass valves, high pressure, with polythene float and flynut complete, screwed for 20mm bore iron pipe or brass ferrule and fixed in repairs complete all as specified and as directed.
S&F Sensor Set for urinals complete set to be replaced in repairs as per manufacturer's instructions including suitable batteries etc complete all as specified and directed.
S&F cockroach trap gratings AISI-304 of size 150X150mm square in shape with 5mm border complete in all respect all as specified and directed.
Disconnecting the electrical connections from LT panel board, taking out from sump well 40 HP electric motor pump set non clogging self priming 100x125 mm size Horizontal/ vertical type disconnecting input and output sewage connections by manual/mech arrangements, dismantling the motor and carrying to workshop for repair and carrying back the after repair, reconnecting with pump set, fixing on foundation in sump well and testing, commissioning to the entire satisfaction of Engineer-in-Charge. (Including taking out pumping set from sumpwell and lowiring the same after suitable repair.)
All as per serial item No 74 here-in-before but 20 HP pump set non clogging self priming 100 x 125 mm size.
All as per serial item No 74 here-in-before but 12.5 HP pump set non clogging self priming type (Horizontal/Vertical type)
M & L for rewinding the electric induction motor 3 phase 400/415 Volts 40 HP, 50 C/S by opening the same carefully removing all windings and cleaning the slots properly and rewinding the same with copper binding wire of existing guage including providing paper insulation sheets, bamboo sticks and applying two coat of varnish for proper insulation, reassembling the motor, testing and commissioning of motor on full load to the entire satisfaction of Engr-in-Charge complete and all as directed and specified. (Incl taking out induction motor and lowering after suitable repair.)
M & L for rewinding the electric induction motor 3 phase 400/415 Volts 20 HP, 50 C/S by opening the same carefully removing all windings and cleaning the slots properly and rewinding the same with copper binding wire of existing guage including providing paper insulation sheets, bamboo sticks and applying two coat of varnish for proper insulation, reassembling the motor, testing and commissioning of motor on full load to the entire satisfaction of Engr-in-Charge complete and all as directed and specified. (Including taking out induction motor and lowering after suitable repair)
All as per serial item No 78 here-in-before but 12.5 HP motor.
M & L for rewinding the submersible electric motor 3 Phase 400/415 Volts 05 /7.5 HP 50 C/S by opening the same carefully removing all winding and cleaning the slots properly and rewinding the same with PVC insulated copper binding wire of existing guage (Make: Devidayal or equivalant as approved GE) including replacement of oil seal & water seal, refilling of oil, lubricants as per existing sizes, ressembling the motor,testing and commissiong of motor on full load to the entire satisfaction of Engr-in-Charge ( including taking out and lowering in position in well of submersible Pumping set )and all as specified and directed.
All as per item No. 80 hereinbefore but capacity of motor 12.5 HP complete (Including taking out and lowering in position in well of submersible pumping set ) and all as specified and directed.
All as per item No.80 hereinbefore but capacity of motor 35 HP complete (Including taking out and lowering in position in well of submersible pumping set ) and all as specified and directed.
Supply only for replacement ball bearing/roller bearing of existing size and make in electric induction motor, 40 HP including applying correct grade grease before replacement and cleaning the motor parts properly complete all as specified and directed.
All as per serial item No 83 here-in-before but 20 HP complete all as specified and directed.
All as per serial item No 83 here-in-before but 12.5 HP complete all as specified and directed.
Supply only for replacement cooling fan of electric induction motor 40 HP to suit the existing size of fan in replacement of fan nut bolt, keys etc all as directed by Engineer-in-Charge.
All as per serial item No 86 here-in-before but 20 HP complete all as specified and directed.
All as per serial item No 86 here-in-before but 12.5HP complete all as specified and directed.
Disconnecting the electric connection from LT Panel board, dismantling pump set non clog self priming 100 x 125 mm size horizontal/vertical type suitable for 40 HP motor complete after diconnecting input and output sewage connections by manual/mechanical arrangements and taking out pump from sump well including dismantling the pump and replacement of unserviceable part ie , steel metal bushes,bearing , nut bolts washer etch cleaning and ressembling the pump and type of machine work ie making shaft and reaming bushes etc, and transporting back the same after repair,reinstalling with motor, fixing on foundation in well and testing,commissiong to the entire satisfaction of Engr- in-Charge. (Including taking out and lowering in position in well of pumping set) all as specified and directed.
All as per serial item No 89 here-in-before but 20 HP complete all as specified and directed.
All as per serial item No 89 here-in-before but 12.5 HP complete all as specified and directed.
M & L for replacement of cast iron sluice valve 100 mm dia PN-1.6 as per IS-780 with brass spindle and iron wheel head including providing new nut, bolt, washers and rubber insertion sheets on both ends and taking down the existing unserviceable valves complete all as specified and directed.
All as per serial item No 92 here-in-before but 150 mm dia complete all as specified and directed.
Supply and replacement of Automatic Star Delta starter 3 phase, 415 volt for centrifugal pump set 12.5 HP with over load relay, contactor ML 1.5 magnetic coil duly fixed in enclosure having relay setting suitable for 12.5 HP pump set including taking down exisiting unservicable starter of any make & type complete all as specified and directed.
Supply and replacement of Automatic Star Delta starter 3 phase, 415 volt for centrifugal pump set 20 HP with over load relay, contactor ML 1.5 magnetic coil duly fixed in enclosure having relay setting suitable for 20 HP pump set including taking down exisiting unservicable starter of any make & type complete all as specified and directed.
Supply and replacement of Automatic Star Delta starter 3 phase, 415 volt for centrifugal pump set 40 HP with over load relay, contactor ML 1.5 magnetic coil duly fixed in enclosure having relay setting suitable for 40.0 HP pump set including taking down exisiting unservicable starter of any make & type complete all as specified and directed.
Supply and replacement of DOL starter 3 phase, 415 volt for centrifugal pump set 5 HP with over load relay, magnetic coil duly fixed in enclosure having relay setting suitable for 5 HP pump set including taking down exisiting unservicable starter of any make & type complete all as specified and directed.
Dismantling the Monoblock/Tulu pump set 1.00 HP, single phase 230 Volt and carrying the pump to workshop for repair, replacement of required parts such as CI impeller, nut bolts, bushes, packing sheet etc.,servicing to motor, greasing etc including rebinding of the copper winding and making ready for fixing, bringing back the pump set and fixing in foundation and testing to the entire satisfaction of Engr-in-Charge complete all as specified and directed.
M&L for painting to CI pipes of any size with two coat of paint to oxidation pound pipes complete all as specified and directed.
M&L for painting with two coats of synthitic enamel paint to Areator motor with gear including gear boxes alongwith connected equipments complete with spray painting complete all specified & directed.
Painting to section line , discharge line, pump, motor with frame and all type of fixture i.e sluice valve, non return valve etc, with one coat of paint after removing cleaing the pipe including marking the direction of flow of Sewage, complete installaton with colour code as directed by Engr-in-Charge. Installation No 5,6,7,11,12,13,14,& 15 (08 Nos)
Taking up/out cast iron Pipe of 100 mm bore water mains including all fittings with spigot and socketed ends or flanged ends including burning out lead joints or dismantling flanged joints for pipe of following bore complete all as specified and directed.
Supply and laying Cast iron Pipe of 100 mm bore with spigot and socketed ends or flanged ends including burning out lead joints or dismantling flanged joints complete all as specified and directed.
M&L for 'Cast iron fittings of size upto 150 mm bore for bends Tapers ,Tee pieces ( single & double branch ) any type and angle/radius and straight connecting pieces but all ends flanged complete all as specified and directed. (Excavation, earth work, & joints shall be measured and paid separately).
M&L for cutting existing cast iron pipe of 100 mm following bore of any description for insertion of fittings and setting the pipe in proper alignment complete all as specified and directed. (Excavation earth work and fittings shall be measured and separately).
Cleaining of sewage well from bottom by means taking out soild sludge/sewage wastage to be disposed out side MOD Land from the starting point complete all as specified and directed. (Sze of well 5 to 7 metre depth , 6 to 8 metre dia approximate ) Sump well 2,5,6,7,10 /11,12,13,14 & 15.
Supply and fix pvc extra flexible suction hose pipe 100mm complete all as specified and directed.
Supply only nut bolt with washer for suitable size complete all as specified and directed.
Repair/replacement of unserviceable phase preventor of existing size of motor capacity 5 HP to 40HP complete all as specified and directed.
M & L for rewinding the electric induction motor 3 phase 400/415 Volts 5 HP, 50 C/S by opening the same carefully removing all windings and cleaning the slots properly and rewinding the same with copper binding wire of existing guage including providing paper insulation sheets, bamboo sticks and applying two coat of varnish for proper insulation, reassembling the motor, testing and commissioning of motor on full load to the entire satisfaction of Engr-in-Charge complete and all as directed and specified. (Incl taking out induction motor and lowering after suitable repair.)
Repairs to gear box of ariaator motors by greasing ,replacement of bearing ,replacement of shaft for Gear box to areaitor ,iron coupling reqd at site testing and commissioning of motor on full load to the entire satisfaction of Engr-in-Charge complete and all as directed and specified. (Incl taking out induction motor and lowering after suitable repair and minor /major items reqd it to make functional at site deemed to be icluded in quated rate )
Supply & lay in replacement of existing unserviceable XLPE insulated, armoured heavy dutyelectric cable with aluminium conductor, 1100 volt grade of crosssectional area 16 Sqmm 4 Core complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of Pipes, cables, poles,Stay and strips etc and getting out in Soft/Loose soil complete all as specified.
Returning, filling-in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified.
Removing excavated material not exceeding 50m and depositing where directed at a level of not exceeding 1.5m above the starting point.
Supply & fixing 3 core PVC Insulated & PVC sheathed Industrial cable for Submersible motors of size 10 Sq mm 415 v complete all as directed and specified .
M&L for MCCB, 4 Pole, 125 A, 25 KA for fixing in existing LT panel box including proper thimble connection, thermal and magnetic release protection complete all as specified and directed.
M&L for MCCB, 4 Pole, 160 A, 25 KA for fixing in DB including proper thimble connection, thermal and magnetic release protection complete all as specified and directed.
Supply and replacement of Automatic Star Delta starter 3 phase, 415 volt for centrifugal pump set 15 HP type MU-2 suitable for single submersible motor with over load relay, contactor ML 1.5 magnetic coil duly fixed in enclosure having relay setting suitable for 12.5 HP pump set including taking down exisiting unservicable starter of any make & type complete all as specified and directed.
Supply and replacement of installation sign board of size 1.2x1.2 x.0.30 mtr with LED tube light 2 nos prewired made out G I sheet with MS pipe 50 mm grouting into ground in PCC height upto 1.50 mtr from ground level and connected to MCB / Street lights for on/off system including necessary pvc aluminium service wire 2 core of 4 sq mm with written name of insttalation No and name complete all as specified and directed including taking down exisiting unservicable installation sign board of any make & type
AGGARWAL & CO (BID ID -3121730)
AR CONSTRUCTIONS (BID ID -3130348)
Jawandha Enterprises (BID ID -3122205)
Arneja Builders (BID ID -3108841)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .