| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.6 CrAccepted-AOC C 9 53 IIND FLOOR SECTOR 08 ROHINI DELHI 110085 | DELHI | NORTH WEST DELHI | DELHI | 110085 | ₹3.6 Cr Quoted ₹2.6 Cr | L1 | Accepted-AOC Being lowest and reasonable |
| 2 | L2₹2.8 Cr+₹19.3 L (7.28%)Rejected-Finance 216 UGF RAM VIHAR ANAND VIHAR DELHI 110092 | SHAHDARA | DELHI | 110092 | ₹2.8 Cr+₹19.3 L (7.28%) | L2 | Rejected-Finance Not being lowest |
| 3 | L3₹2.8 Cr+₹20.2 L (7.63%)Rejected-Finance 110059 NEW DELHI NATIONAL CAPITAL TERRITORY OF DELHI 110059 | WEST DELHI | DELHI | 110059 | ₹2.8 Cr+₹20.2 L (7.63%) | L3 | Rejected-Finance Not being lowest |
| 4 | L4₹2.9 Cr+₹23.8 L (8.99%)Rejected-Finance | ₹2.9 Cr+₹23.8 L (8.99%) | L4 | Rejected-Finance Not being lowest |
| 5 | L5₹2.9 Cr+₹28.2 L (10.7%)Rejected-Finance WZ 250 B 2 GALI NO 08 SADH NAGAR I PALAM COLONY NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | ₹2.9 Cr+₹28.2 L (10.7%) | L5 | Rejected-Finance Not being lowest |
Tender Value
₹3.0 Cr
EMD Value
₹3.7 L
Closing Date
12 Jan 2023, 6:00 pmClosed
HQ Chief Engineer Delhi Zone Delhi Cantt-10
HQ Chief Engineer Delhi Zone Delhi Cantt-10
ADDN ALTN TO BLDG NO. P-2 P-5 and P-11 TOTAL 48 QTRS AT BASANTRA LINE UNDER GE WEST DELHI CANTT 10
2022_MES_557230_1
CEDZ/TOKEN-64 OF 2022
Open Tender
Civil Works
Item Rate
365 days
Delhi Cantt
As per NIT
9 documents required · 9 mandatory
₹2,000
GE (West)
₹3.7 L
Yes
31 Jan 2023
12 Oct 2022
14 Jan 2023
12 Oct 2022
12 Jan 2023
29 Dec 2022
12 Oct 2022 - 27 Oct 2022
Amount
M&L for repairing of spalled concrete from ceiling in the following stages:- 1. Prepration of existing surfaces like chipping of unsound weak / loose concrete with electric hammer or manually including tapering all edges, making square shoulders of cavities etc. n.exc 50 mm thickness removal of debries, complete all specified and directed by the Engineer-in-charge. 2. Applying rust remover cum passivator Sika rustoff 100 @ 0.20kg/Sqm/per coat or as per manufacturer's specifications to remove rust from existing reinforcement (Make : Sika or equivalent) 3. Applying a epoxy based zinc rich rebar corrosion protection system of product : Fiazin (R) R @ 0.15Kg/Sqm/coat or as per manufacturer's specifications (Make ; Sika or equivalent) 4. Mixing & applying two component Epoxy resin concrete Bonding coat of Sikadur(R)-32 LP A & B @ 0.40 Kg/Sqm(Mixing proportion as per manufacturer's instructions) on prepared RCC surfaces as per manufacture specification including prepartaion of surface by chipping and throughly cleaning of surface complete whereever required over new reinforcement (if required) and as directed by the Engineer-in-charge.(Make : Sika) (Reinforcement will be measured and paid separatley). 5. Apply a pre-batched one component polymer modified cementious patch repair thickness of mortar n.exc 50mm thick in 3 layer of Product: Sika Mono Top®-122 F as per manufacturer insturctions and as directed by the E-i-C. 6. Apply aluminised synthetic resin Concrete curing compounds for the prevention of premature water loss from concrete of product: Antisol®-E(WP) @ 0.10 to 0.20 kg/m2 as manufacturers instructions and as directed by the Engr-in-Charge.
M & L for providing rebar of required length & dia with Sika Anchor Fix ® -3/Mungo/Fischer FISV 390/Hilti RE-500 epoxy resin whereever required in RCC members including power drilling for holes (of size 16mmx160mm ), cleaning of holes, filled with epoxy to ensure the bond as per manufacturers instructions, complete all as specified and directed by the Engr-in-Charge. (Make : Sika/Fosroc/Pidilite)
M & L for applying one part plasto-elastic coating based on UV-curing acrylic dispersion with excellent crack-bridging properties, protective coating system to achieve DFT (Dry Film Thickness) of 150 microns in two coats after application of one coat of Silane Siloxane modified Primer on concrete surface including Surface preparation by high pressure water jet or manually as per direction of Engineer-In-Charge in recommended RAL Shades. Primer: Sikagard®-551 S @ 0.2 kg/m2. Coating: Sikagard®-550 W Elastic @ 0.2 kg/m2/coat in 2 coats. (Make : Sika/Fosroc/Pidilite)
Making "V" groove of 5mm wide and 5mm deep over crack line by electrically operated angle grinder with diamond concrete saw blade and cleaning it by air blower and sealing it with polymer modified mortar as directed by the Engineer-in-charge.(Make : Sika/Fosroc/Pidilite)
Drilling and fixing NRV injection packers in RC members including, (a) Drilling Holes: Drilling holes in structural members at the intervals as per recommendation of engineer in charge. (b) Cleaning of holes: Clean the holes by air blower prior to fixing nozzles. Fixing of Packers: Insert 12 mm dia., 50~75 mm long injection packers in cleaned holes with solvent free, moisture insensitive epoxy resin based putty or equivalent. (c) Cutting of Packers: Cut the packers by cut of wheel after completion of grouting without damaging structural elements.
M & L for shrinkage free low viscous epoxy resin based injection grout. Product: Sikadur®-52 as per manufacturers instructions and as directed by the Engr-in-Charge. (Make : Sika/Fosroc/Pidilite)
M & l for mixing & applying two component Epoxy resin concrete Bonding coat of Sikadur(R)-32 LP A & B @ 0.40 Kg/Sqm(Mixing proportion as per manufacturer's instructions) on prepared RCC surfaces as per manufacture specification including prepartaion of surface by chipping and throughly cleaning of surface complete whereever required over new reinforcement (if required) and as directed by the Engineer-in-charge. (Reinforcement will be measured and paid separatley). (Make : Sika/Fosroc/Pidilite)
FOR JACKETING OF COLUMN & BEAM WITH MICRO CONCRETE M & L for erecting steel props (upto full height) braced at centre, resting on wedge and block to support the structure provisionally during repair work and maintaining them in position till required etc. complete all as specified and directed by the Engineer-in-charge.
M & L for water tight centering, shuttering and form work to micro concrete including bolting, strutting, propping etc. and removal of form work from column, beam etc. in flat surfaces, complete all as specified and directed by the Engineer-in-charge.
M & L for ready to use non shrink, cementitious free flow micro-concrete (> 100 mm). Product: SikaRep® Microcrete-4 + adequate coarse aggregate, Yield: approx. 17 ltr/bag (30kg) (depending on the size and quantity of coarse aggregate added) Product requirements: compressive strength > 60 N/mm2 (28 days) according to ASTM C 1107-99, complete all as specified and directed by the Engr-in-Charge. (Make : Sika/Fosroc/Pidilite or equivalent)
M & L for aluminised synthetic resin Concrete curing compounds for the prevention of premature water loss from concrete of product Antisol®-E(WP) (Product Requirement: Antisol®-E(WP) conforms to ASTM C 309-89 Type II Class A) @ 0.10 to 0.20 kg/m2, complete all as specified and directed by the Engr-in-Charge. (Make : Sika/Fosroc/Pidilite or equivalent)
M & L for protection plaster (25 – 30 mm) reinforced with virgin polypropylene mono filament fibres with admixture: Sika® Plastocrete Plus @ 0.10 kg per bag of cement, reinforcement: Sika® Fibre h 150 @ 0.9 kg/cum complete all as specified and directed by the Engr-in-Charge. (Product requirements admixture: conforms to IS 2645. Product requirements reinforcement: conforms to ISO 9001-2000 and ASTM C 1116 type III4.1.3; specific gravity: 0.91 kg/ltr; fine monofilament; alkali proof; containing no reprocessed olefin materials). (Make : Sika/Fosroc/Pidilite or equivalent)
Dismantling of brick tiles or terracing tiles single layer on roof complete all as spd & directed.
M & L for PCC tiles of size 250mm x 250mm x 22mm thick set and jointed grey cement with pigment including 10mm thick cement plaster in CM 1:4 all as specified and directed.
Demolition of mud phuska on roof slabs, any thickness incl cleaning of roof surfaces and removing the debris upto the distance exc. 1.00Km but n. exc. 1.5Km complete all as spd & directed.
Scraping of old tar felt roof treatment over concrete padding of any thickness etc from roof incl finishes or junction or parapet and cleaning the surface (by mechanical means like grinder, etc) complete all as spd & directed.
M&L for cement concrete 1:3:6 type C-1 (using 20mm graded stone aggregate) on roof padding with water proofing compound surface finished even and smooth without using extra cement complete all as spd & directed. (Rate of WPC shall be included in unit rate)
M&L for water proofing treatment in following stages:- 1. Rendering 10mm thick in CM 1:3 with WPC (as per manufactures instructions) over concrete surfaces. 2. First coat of bitumen primer confirming to IS-3384@ 0.40 Kg/Sqm over plastered surface.(Bitumen primer shall be TANK MASTIC of M/S STP Ltd or ‘EMW FLATE’ of M/S Texas India Ltd). 3. Second coat of binding material using blown type bitumen confirming to IS-702 Gde 85/25 @ 1.2 Kg/Sqm applied over bitumen primer. 4. Third layer of APP polymeric water proofing membrane, minimum 3mm thick and weighing not less than 3.0 Kg/Sqm with a centre core of 90 micron high density polyethylene film protected on both sides with a high quality polymeric asphaltic mix, the polymeric asphaltic mix will be protected on both sides with thermo fusable HMHDPE film of make super thermolay manufactured by STP Ltd or ‘Hyper Plas’ (Polyster) manufactured by M/S IWL Ltd or ‘Shaliplas’ (polyester) manufactured by M/S Capital Steels and chemicals Pvt Ltd as approved by GE, black finish reinforced with non-woven polyester matt, with a thermo fusable finish.torching overlaps with a propane or a butane gas torch, with a overlap of 75mm at the sides and 100mm at the ends complete all as specified and as directed. 5. Final coat of binding material using blown type bitumen confirming to IS-702 Gde 85/25 @ 1.2 Kg/Sqm applied over APP membrane. Over this layer stone dust @ 0.50 Kg/Sqm shall be applied uniformly.
Taking down chowkats or frames not exc. 1.5 sq. m with shutters (without taking off shutters from the frames) , complete all as specified and directed.
Taking down chowkats or frames exc. 1.5 sq. m but not exc 4 sqm each with shutters (without taking off shutters from the frames) , complete all as specified and directed.
Taking down cupbord shutters of any description exc 1 sq. m and not exc 2 sqm each, complete all as specified and directed.
Taking down old window / ventilators with frame, any description, including guard bars not exc 1.5 sqm each , complete all as specified and directed.
S&F powder coated anodised aluminium frame for windows, ventilators with one or more rebates including necessary joining cleat, powder coated aluminium snap beading, screws for fixing etc. complete all as spd & directed. Note: (1) Only aluminium items to be measured. (2) Glass, wiremesh, handles to be measured & paid separately. (3) Minimum thickness of powder coating to be 50 micron.
S & F powder coated anodised aluminium window and ventilator shutters, side hung type with out sash bars, aluminium sections weighing not less than 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150 mm long ( 1 No.) hinges type B-21 100 mm long (2no.) suitable handle 1 no.) each shutter complete all as specified.
S & F powder coated anodised aluminium deco grills including channel, necessary fixing arrangement to the windows (Section approved by the GE/AGE) complete all as specified.
S & F for mild steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors, angle iron chowkhats; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and directed. .
S&F 35 mm thick 2nd class hardwood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, cla-use 8.24 (a); supplied and fitted to chowkats incl one shop coat of pink primer as speicifed and directed.
S & F factory made 35mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides all as specified and directed.
S&F 25mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides as shutter of cupboard complete all as spd & directed.
S&F Solid PVC door frame of size 50mm x 95mm made out of 5mm wood grain printed PVC sheet reinforced with M.S square tube, complete all as specified and directed.
S&F Factory Made Solid PVC Moulded Door Shutter, 28 to 30 mm thick (stiles),with 2, 4, or 6 raised panel design with 2mm thick 3D wood grain Moulded PVC Sheet Polyurethane painted on the front face & 2mm Plain colour PVC Sheet on back face complete all as specified and directed.
S & F stainless steel butt hinges 100mm long medium weight etc complete all as specified and directed.
S & F 200mm long aluminum, anodized barrel tower bolts of extruded section complete all as specified & directed.
S & F aluminum anodised handle 150 mm long cast type complete all as specified & directed.
S&F in repair stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples (for windows and gauzed doors) all as specified and directed
S&F for Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, fixing of nuts and bolts as necessary, gusset plates, riveting, etc., conforming to Fe -290 Gde E-165 complete all as specified and directed.
S&F for Pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/chajjas covering, cladding to wall fixed with self tapping screws incl cutting of chase in wall and inserting 50 mm deep, and making good and matching the surface with existing finish, complete all as specified and directed.
M&L for preparation of new steel surfaces over 10 cm width or girth, not otherwise described and applying two coat of synthetic enamel painting over a coat of red oxide primer etc all as specified and directed.
M & L for preparation of new or previously untreated wood or wood based surface of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint (approved tint) over a coat of pink primer complete as specified and directed.
S&F in repair110 mm bore PVC (SWR) pipes single socket in any length with rubber ring/ cement solvent cement jointsfixed to walls incl MS clamps of suitable size made of flat iron 25x3mm including taking down old unsv pipes complete all as specified and directed.
S&F PVC bend/tee suitable for 110mm bore pipe complete all as directed
S&F Rolled/rounded or tee sections, fixed independently, with and including connecting plates, etc. (cut to ordinary lengths for Railing and similar sections and similar work with fixing/grouting on wall in PCC 1:3:6 (block of size 200x200x200mm) complete all as specified and directed
Demolition of reinforced cement concrete roofs, floors (other than groung floor), beams, staircases, landing, chajjas and similar suspended work .
M&L for ready mix concrete (RMC) of design mix M-25 (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs landings, balconies canopies,deck slabs and in shelves and the like complete all as specified and directed.
S&F TMT bars 10mm dia and over, cut to lenght, bent to shape required, including cranking, bending spirally for hooping for coloums, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips as specified and directed.
S&F TMT bars 6mm to 8mm dia and over, cut to lenght, bent to shape required, including cranking, bending spirally for hooping for coloums, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips as specified and directed.
All as per Srl item No. 46 above but TMT bars 6mm and over upto and including 8mm as in stirrups, spacers and binders.
M&L form work to soffits of suspended slab such as roof beams/slabs, chhajja, floor slabs, cover slab, shelves, landing and similar work not exc. 200mm thickness finished rough (horizontal or sloping) as specified and directed.
M&L form work to sides and soffits of floor or roof beams, beams, haunchings, griders bressummers lintels, cantilevers shelves including sup-ports, overhangs, etc also splays between floors and beams etc, complete all as specified and directed.
M&L formwork to edges of concrete flats, treads, breaks in floors, windows cills, concrete railings, opening in concrete walls, floor and roofs n.exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n.exc 20cm wide rough finished surfaces complete all as specified and directed.
M&L rendering 15 mm thick in cement mortar 1:4 on fair faces of brick or concrete surfaces finished fair and even with using extra cement incl water proofing compound @ 3% by weight of cement and taking down old cement plaster of any description, complete all as specified and directed. Note:- (i) The rendering is to be done in cement and sieved badarpur sand only (1:4).(Supplying integral WPC is included in this unit rate.) (ii) Cost for necessary steel formwork & shuttering of the above aspects shall be deemed to be included in the quoted rate of the respective item and nothing extra shall be paid on any account.
M&L rendering 15 mm thick in cement mortar 1:4 on fair faces of brick or concrete surfaces finished fair and even with using extra cement incl water proofing compound @ 3% by weight of cement, complete all as specified and directed. Note:- (i) The rendering is to be done in cement and sieved badarpur sand only (1:4).(Supplying integral WPC is included in this unit rate.) (ii) Cost for necessary steel formwork & shuttering of the above aspects shall be deemed to be included in the quoted rate of the respective item and nothing extra shall be paid on any account.
M&L for Washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement; 4 coarse sand)(sand source - Badarpur only) furrowing the under layer with scatching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 white cement: 1/2 coarse sand: 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings incl nailing with 75 mm MS nails @ 450 mm both ways on wall surface complete all as specified and forming groove (area of each panel not exceeding 2 sqm each) of size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete incl taking down old plaster as per specifications and direction of the Engineer-in-charge.
M&L for rendering 15 mm thick in cement mortar 1:6 on fair face of brick work/ concrete surfaces and finished even and smooth without using extra cement incl taking down old plaster, complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar 1:6 on fair face of brick work/ concrete surfaces and finished even and fair without using extra cement complete all as specified and directed.
M&L for rendering 5 mm thick in cement mortar 1:3 on ceiling and finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 10 mm thick in cement mortar 1:3 on ceiling and finished even and smooth without using extra cement incl taking down old plaster, complete all as specified and directed.
M&L for complete removal of existing treatment on walls to the entire satisfaction of Engr-in-Charge including preparation of surfaces and applying two coat of cement base paint complete all as specified and directed.
M&L for preparing newly plastered surfaces on walls and applying two coat of cement base paint over a coat of alkali resistant primer complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls applying birla white putty 2mm on wall even and smooth surface and applying two coat of oil bound distemper over a coat of alkali resistance primer (of approved quality and tint) on wall using painting roller, complete all as specified and directed.
M&L for complete removal of existing treatment by brooming down or steel wire brushing, scrapping down smoke, mass, efflorescent salt and oil and greesy spot etc. washing rubbing down distemper surfaces and applying birla white putty 2mm on wall even and smooth surface and applying two coat of oil bound distemper over a coat of primer (of approved quality and tint) on wall using painting roller, complete all as specified and directed.
M&L for preparation of old decorated surfaces and applying two coats of white wash on ceiling complete all as specified and directed.
M&L for preparation of new plastered surfaces and applying two coats of white wash on ceiling complete all as specified and directed.
Demolition of cement concrete In ground floor and paving n.exc 15CM thickness (below or above ground levelall as specified and directed.
M&L for Plinth protection 75 mm thick in PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) laid in alternate bays(not exc 2 Sqm each) finished even and fair at top using extra cement and providing joints throughout the thickness of plinth protection, filled with mastic filling comprising one part of bitumen 85/25 graded and three parts of sand by weight all as directed at site.
S&F in repair 110mm dia PVC (SWR) pipes single socketed in any length with rubber joints laid in floor/trenches all as directed.
All as per item No. 66 above here-in-before but 75mm bore of pipe.
S&F in repairs 110mm PVC (SWR) junction single, (Single T) equal or unequal with access doors complete all as spd and directed.
All as per item No.68 above here-in-before but 75mm bore of pipe.
S&F in repair 40mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches, floors all as specified & directed.
S & F PVC (SWR) cowl for 75mm dia complete all as specified and directed.
M & L for preparation of old painted wood or wood based surface of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint (approved tint) complete as specified and directed.
Material and labour for preparation of old steel surface of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint (approved tint) complete as specified and directed.
Demolition of brick work or stone/boulder masonry built in cement mortar incl all quoins, arches, pillars etc but excluding ashlars facings dressed stone work and Precast concrete articles, complete all as sfd and directed.
M&L for Brick work with Sub class 'B' bricks straight or curved on plan exceeding 6m mean radius, built in CM 1:6.
M&L for Brick work with Sub class 'B' bricks straight or curved on plan to any radious in half brick thick walls, built in Cement mortar 1:4 complete all as specified and directed.
M&L for Providing precast cement concrete type B0 1:2:4 (12.5 mm graded agg) louvres and jallies, 25mm thick (measured solid), including all mouldingsfixed to brick/concrete surfaces with cement mortor 1:4 complete all as specified and directed.
S&F CPVC tubing 20mm bore with all fittings and fixed complete to wall and ceiling or laid in floors incl taking down old steel GI tubing complete all as specified and directed.
S&F CPVC tubing 25mm bore with all fittings and fixed complete to wall and ceiling or laid in floors incl taking down old steel GI tubing complete all as specified and directed.
S&F in repair vitreous chinaware wash hand basin flat back of size 550mm x 400mm complete including provision of pair of mild steel angle iron brackets of suitable size duly painted, 32 mm dia chromium plated waste coupling, PVC waste pipe and cutting for pinning in ends of brackets in wall etc complete all as specified and directed.
S&F in repair viterous china squatting pan (orissa pattern) long pan size 580x440mm white with integral footrest with & including 'P' or 'S' trap complete (excluding flushing cistern and flush pipe), complete all as specified and directed.
S&F in repair curtain rail (drapery rod ) 20 to 25 mm dia coloured with pair of suitable brackets,fennals and also making good the wall surface to match the existing surfaces complete all as specified and directed.
S&F in repair 15 mm bore angle valve, cast copper alloy screwed down high pressure with capstain head with long shank & cup complete all as specified and directed.
S&F in repair 15mm dia bib tap long body fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe, fancy type, cast copper alloy, chromium plated long body with flange complete all as specified and directed.
S&F in repair 15mm dia chromium plated pillar tap fancy type with fly nut capstan head screwed for 15mm dia pipe, complete all as specified and directed.
S&F in repair stop valve fancy type chromium plated cast copper alloy with crutch or butterfly handle screwed down both ends for high pressure as per IS suitable for 15 mm dia iron pipe all as specified.
S & F in repair CP shower rose with shower arm rod all as specified and directed.
S&F in repairs PVC low level white flushing cistern, valveless syphonic action type 10 ltr capacity with inlet, ball valve, float and handle including PVC flush pipe 32mm dia bend and a pair of mild steel iron brackets of suitable size including making necessary connection to water supply pip line and, complete all as specified and directed.
Dismantling of floor, hearth or walling including cement mortor bedding (but not backing removing unserviceable tiles and rubbish off the premises complete all as specified and directed.
M&L for Glazed ceramic colour tiles in vertical surface of size 350 x250x 7 mm or 450x 350x7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick cement plaster in CM 1:4 all as specified and directed.
M&L for Non Skid ceramic tiles 7 to 8 mm thick(square/ rectagular) area of each tile exceeding 0.11 sq m but not exceeding 0.18 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 15mm thick screed bed or bedding layer in CM 1:6, all as specified and directed.
M&L for Non Skid ceramic tiles 7 to 8 mm thick(square/ rectagular) area of each tile exceeding 0.18 sq m but not exceeding 0.38 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 15mm thick screed bed or bedding layer in CM 1:6, all as specified and directed.
All as per item No. 93 here-in-before but in skirting/ dado, over and including 10mm thick screed bed in CM 1:4 all as specified and directed.
Water proofing treatment of sunken RCC slab : (i) Demolition of unreinforced cement concrete exc 15cm thickness for sunken portion of WC, complete all as specified and directed. (ii) Apply a coat of cement sullry @ 0.488 kg/sqm mixed with tapecrete @ 0.253 kg/sqm after surface preparation all as per manufacturer's instructions. (Make of tapecrete : M/s CICO Engg service). (iii) Apply hot bitumen 30/40 (grade S-35) conforming to IS-73-1961 @ 0.70 kg/sqm and providing transparent polythene film 200micron (heavy duty) conforming to IS - 2508-1977 laid with 150mm overlaps. (iv) Then apply 1.5mm thick layer of cement slurry @ 1.288 kg/sqm mixed with tapecrete @ 0.570 kg/sqm and course sand @ 1.298 kg/sqm. Allow the treatment to air curing for 4 hours followed by water curing for 48 hrss. The whole treatment shall be taken upto full depth of parapet wall and tuck into groove in parapet alround. (v) Sunken floor shall be filled with graded cinder (including PCC 1:5:10 Type-C2 using 40mm graded stone aggregate).
S&F in repair SS kitchen utensil rack (Kitchen plate rack) rectengular of size 30x30x8 inch, made of stainless steel 1mm thick, all as specified and directted.
M & L for green marble 18mm thick (table rubbed and polished) in cooking platform/floor, trades & risers, skirting etc machine cut laid over 20mm thick screed bed or beding layer in CM 1:4 and jointed and pointed with grey cement mixed with colour pigment to match the shade of the slab including rubbing and poishing and making edges chamfered and demolition of old stone slab of any description, complete all as specified and directed.
Dismantling of PVC water storage tanks of 1000 ltrs capacity and removing from site all as specified.
S&F rotational moulded polythylene water storage tanks 500 Ltrs capacity, white coloured, triple layered (cylindrical vertical with closed top) hoisted including nipple suitable for water tank connection and fixed in position complete all as spd & directed.
S&F in repair sink made of stainless steel 1mm thick for kitchen with plugs, washers and wastes including bedding in cement mortar to dwarf wall or including fixing cantilever, brackets made out of angle iron of suitable size and connecting union to pipe over all size 495x420 mm, bowl size 410mm x 330mmx 160mm complete all as specified and directed.
M&L for 18 to 20mm thick machine cut kota stone as in treads and risers (in one piece) laid over 15mm thick cement screed base in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab inlcuding rubbing and polishing and demolition of old stone slab of any description complete all as specified and directed.
S&F aluminium powder coated openable double shutter window made of following specifications and including as under: (Net external size will be measured). (a) Aluminium frame powder coated all around of hollow section 100mm x 44mm x 1.50mm thick. (b) Provn of glazed openable shutter of section 44mmx18mmx1.25mm provided with 4mm thick tinted glass with suitable EPDM beading 0.2Nos 100mm powder coated aluminium hinges, 02 Nos 100mm long powder coated aluminium handle. (c) All as in para 102(b) above but using stainless steel wiremesh 0.36mm dia and 1.40mm aperature fixed with stainless steel screws and aluminium beading in lieu of 4mm thick tinted glass and EPDM beading. (d) Alum powder coated grill of weight not less than 2.60kg/sqm on external side with suitable frame/aluminium runner to be fixed on the window frame.
S&F aluminium powder coated ventilators made with following specifications and including as under: (Net external size of ventilator shall be measured.) (a) Aluminium frame powder coated styles, bottom, top and middle rail of hollow section 50mm x 25mm x 1.80mm thick. (b) Lower portion of ventilator shall be fixed with 3mm thick pin headed glass fixed with suitable aluminium beading clips and EPDM beading (rubber). (c) Upper portion shall be fixed with aluminium powder coated louver guides fixed with 3mm thick pinheaded glass with suitable EPDM beading incl suitable handle and clips. (d) Stainless Steel wire cloth, 0.36mm norminal dia of wire and average width of aperture 1.40mm and fixed with suitable frame in upper panel
Excavating in trenches, nexc 1.5 m wide and nexc 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes, etc nexc 10 sqm on plan and n exc 1.5m in depth and getting out in hard dense soil all as specified and directed.
Returing filling in including spreading, leveling, watering and well ramming in layers not exc 25cm all as specified & directed.
Removing excavation material out of MoD land and depositing where directed at a level n exc. 1.5m above the starting point all as specified & directed.
M&L for hardcore of broken stone or boulders of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface
M&L for PCC (1:3:6) type C2 using 40mm graded stone agg as in foundations filling and mass concrete all as specified and directed.
M&L for RCC 1:2:4 type BO using 12.5mm graded stone agg as in foundations including rafts, footings, foundation beams plinth beams bases for columns etc basement slabs, under reamed piles and mass concrete all as specified & directed
M&L for RCC 1:2:4 type BO using 12.5mm graded stone agg as in Beams cantilevers bressummers lintels over 1.5m span all as specified & directed
M&L for RCC 1:2:4 type BO using 12.5mm graded stone agg as in columns, pillars, piers, posts and struts all as specified & directed
M&L for RCC 1:2:4 type BO using 12.5mm graded stone agg as in slabs supported on walls beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified & directed
Use and waste of flat and rough finish formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation & plinth beams and similar work vertical or to batter all as specified & directed.
Use and waste of flat and rough finish formwork to sides of concrete formwork to sides of pillars, posts, struts, piers, columns and stanchions all as specified & directed.
M&L for cement concrete 1:4:8 type D2 (using 40mm graded aggregate) as in sunken floor all as directed by Engg-in -Charge.
Description of Work / Item(s)
Amount
Taking down carefully copper/aluminium any type of point wiring (light/fan/socket /power) complete (fittings such as switches, ceiling roses, holders, sockets,regulators light fittings) and making good the disturbed surfaces of wall/floors/ceiling etc) complete all as specfied & directed.
Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through and including non-metalic rigid PVC conduit medium grade ISI Marked and all conduit accessories concealed in wall/fixed to roof/truss/columns etc and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuity conductor, fabricated branded modular metal flush box duly make embossed, concealed in walls with suitable modular inner and outer plate for housing modular switches , socket outlet and fan regulators etc , all as specified and directed for the followings:- Note: ceiling Light/ Fan points wirings are to be drawn in existing in situ conduits all as directed.
(a) One light/Fan/bell/Exhaust Fan/Fresh Air Fan point controlled by one switch
(b ) One socket outlet point 5 Amps on independendent board
(c ) One socket outlet point 5 Amps controlled by one switch on same board along with other switches.
(d) One light point controlled by two, two way switch with cable 1.5 sqmm size ( switch to be measured and paid separtely)
All as per item No 2 above but with 2 core copper conductor cable FLRS 2.50 sqmm for one 3 pin modular socket outlet,15 Amps concealed and including provision of 2.50 Sqmm PVC insulated copper conductor cable as earth continuity conductor on independent board.
Supply and fix switch modular type single pole one way 6 Amps all specified and as directed.
Supply and fix modular socket 5 pin multi purpose 6 Amps flush type .
Supply and fix modular socket multi purpose 2-in-1, 6 pin 6/16 Amps 2 module.
Supply and fix modular switch 16 Amps one module single pole one way.
Supply and fix modular ceiling fan regulator , step type for ceiling fan 120 w -2 module .
Supply and fix switch modular type single pole two way 6 Amps all specified and as directed.
Supply and fix switch modular type single pole bell push 6 Amps.
S&F of electric bell Ding-Dong AC 230 Volt SP with brass screws and cup washers all as specified and directed.
M & L for Decorative City 3 walll light fixture made up of Polycarbonate,suitable for Spiral B-22 Base including 9 watt LED Bulb complete all as specified.
S & F of angle Lamp holder,PVC /Polycarbonete type with back plate and metallic ring suitable for B 22 base complete all as specified and directed.
S&F of LED bulb of 9 watt ,B 22 Base, colour temp 6500K complete all as specified and directed.
Supply, laying and drawing submain wiring in and including 20 mm dia concealed PVC rigid conduits including cutting of chases for laying conduit making good the surfaces as per existing surfaces or as directed on walls 02 runs of IC x 6.00 sqmm (Main Cable and neutral) and one run of IC x 6.0 sqmm (as earth wire) of multistranded copper conductor PVC insulated unsheathed cables of 1100 volts grade conforing to IS : 694 of 1990 complete including connection all as specified and directed.
Taking down ceiling fan, ceiling cable end, dismantling blades and removing fan and blades and deposit to the MES store yard complete all as specified and directed.
Fixing only old repaired ceiling fan and collected to MES Yard already taking down and Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. complete all as specified and directed
M&L for opening up the winding of ceiling fan 1200 mm sweep any make and type and rewinding with super enamelled copper winding wire,wraping insulating material, insertion and varnishing well including drying complete. Testing of the ceiling fan after refixing in position to the entire satisfaction of Engr-in-Charge.
Supply and fixing ceiling fans complete with blades, down rods,remote and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed.
S & F LED light fitting 1X10W bulk head luminaires including driver connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F of factory made epoxy polyester powder coated distribution board SP&N 8 way fabricated from minimum 1.6 mm thick CRCA sheet with metal double door (IP-43 protection ) fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, Neutral bar, standard DIN rail, eath bar and cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one DP MCB as incomer and 6 SP MCBs as outgoings complete all as specified and conforming to IS: 8623 alongwith cable end box for above DB all as specified and directed. NOTE (a) MCBs shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.
S&F of factory made epoxy polyester powder coated distribution board TP & N 4 way (VTPN MCCB DB) with metal double door (IP-54 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed on wall and suitable for universal mounting and including 200 Amps copper bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with provn for DPX 160, 4 pole MCCB and ELM as incommer and 12 SP MCBs outgoings complete all as specified and conforming to IS: 8623 along with cable end box for above DB including taking down old DBs all as specified. NOTE :- (a) MCBs shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.
S&F in of MCCB 125 Amp 4 pole 16 KA at 415 V with fixed thermal megnatic release complete all as specified directed.
S&F of single pole MCB 6 to 32 Amps, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for ‘B’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 including taking down old MCB's complete all as specified and directed.
S&F of SPN MCB 32 amp, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for ‘C’ curve, 10 KA breaking capacity, complete all as specified and directed.
Supply and fixing LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.complete all as specified and directed.
S & F PVC Frtesh Air Fan 250 mm sweep,,1400 RPM,single phase,240V,50Hz including cutting of holes complete all as specified and directed.
Supply and fixing LED Building security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65 protection complete. complete all as specified and directed.
S&F ceiling rose 3 phase/PVC/polycarbonate isolated body complete all as specified and directed.
S&F single pole and neutral enclosure with a two pin earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and directed.
Supply and Fix HOT press moulded SMC Meter box of inside dimensions 250x250x155 mm with hinged doors and all accessories suitable for fixing 01 nos single phase digital electronic meter dully inside the box complete all as specified and directed.
S&F of single pole MCB 40 Amps, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for ‘B’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 including taking down old MCB's complete all as specified and directed.
M&L far Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, burieddirectly in ground (earth pit not lessthan 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as specified and directed.
S&F of electric storage water heater of capacity 25 ltr with vitreous enamel coating with all accessories and fittings arrangements and testing after installation complete all as specified and directed. Model- Monza EC Make- Havells Note: Rates are inclusive of connection from existing pipe line to electric storage water heater.
Taking down carefully Exhaust fan and deposit to MES store with all connected accessories after disconnecting all connection of and refixing the same on site carefully all as specified and directed.
Taking down carefully electric meter and deposit to MES store with all connected accessories after disconnecting all connections and refixing the same on site all as specified and directed.
V M CONSTRUCTION
V r traders
CHOPRA BUILDERS
imran construction company
A R construction
M/s. Kansal Construction Co.
Adhunik Builders
V M CONSTRUCTION
V r traders
CHOPRA BUILDERS
A R construction
M/s. Kansal Construction Co.
L G BUILDERS
imran construction company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .