| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.5 CrAccepted-AOC 11 JAMES HICKEY SARANI 2ND FLOOR KOLKATA 700069 | KOLKATA | KOLKATA | WEST BENGAL | 700069 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹13.3 Cr+₹1.8 Cr (15.9%)Rejected-Finance SRIVARI NILAYM 3C 714 3RD CROSS KALYAN NAGAR 1ST BLOCK HRBR LAYOUT BANGALORE 560043 | BANGALORE | BANGALORE | KARNATAKA | 560043 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹14.0 Cr+₹2.5 Cr (21.5%)Rejected-Finance | L3 | Rejected-Finance Not being L1 | |
| 4 | Rejected-Technical 116 RUNWAL DIAMOND OPP PALACE ORCHARD N I B M UNDRI ROAD MOHAMADWADI PUNE 411 060 | PUNE | PUNE | MAHARASHTRA | 411060 | - | Rejected-Technical See evaluation report | |
| 5 | Rejected-Technical | - | Rejected-Technical See evaluation report |
Tender Value
₹13.6 Cr
EMD Value
₹10.0 L
Closing Date
31 Dec 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Chief Engineer AF Bangalore
Chief Engineer AF Bangalore No. 2 DC Area MES Road Yeshwantpur Post Bangalore 560022
PROVISION OF DEFICIENT MARRIED ACCOMMODATION AT AF STN SULUR (PHASE-II)
2024_MES_682064_1
801646/AF/E8
Open Tender
Civil Works
Lump-sum
1080 days
GE(AF) Sulur
S CLASS Cat a i
8 documents required · 8 mandatory
₹3,000
GE (AF) SULUR
₹10.0 L
Yes
24 Jan 2025
31 Oct 2024
7 Jan 2025
31 Oct 2024
31 Dec 2024
11 Dec 2024
1 Nov 2024 - 11 Nov 2024
Amount
BOQ Dated 29 Nov 2024
GENERAL SUMMARY NOTE: Schedule ‘A’ Part II to XII are prepriced by MES under Ser No. 2 to 12. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lumpsum price worked out by the contractor for “Internal Water Supply” as listed in Schedule ‘A’ Part–II
Lumpsum price worked out by the contractor for “Internal Electric Supply" as listed in Schedule ‘A’ Part–III
Lumpsum price worked out by the contractor for “Site clearance and development" as listed in Schedule ‘A’ Part- IV.
Lumpsum price worked out by the contractor for "Road/culvert/Footpath" as listed in Schedule ‘A’ Part -V .
Lumpsum price worked out by the contractor for “Sewage Disposal” as listed in Schedule ‘A’ Part – VI.
Lumpsum price worked out by the contractor for “Area Drainage” as listed in Schedule ‘A’ Part – VII.
Lumpsum price worked out by the contractor for “External Water supply” as listed in Schedule ‘A’ Part – VIII.
Lumpsum price worked out by the contractor for “External Electric Supply ” as listed in Schedule ‘A’ Part – IX.
Lumpsum price worked out by the contractor for “Fire fighting ” as listed in Schedule ‘A’ Part – X.
Lumpsum price worked out by the contractor for “LIFT” as listed in Schedule ‘A’ Part – XI.
Lumpsum price worked out by the contractor for “Lighting Protection” as listed in Schedule ‘A’ Part – XII.
Sch 'A' Part - I : BUILDINGS OR WORKS Design and Construction of Md Accn for Sergeant /Cpl including GF stilt parking in 7 storey (Ground+6 storey) with using 3D monolithic modular Technology / precast construction in RCC of grade as per structural drawings with Cast in Situ foundation with ATT, PU based WPT, RCC Water Tank on terrace, earthquake resistance as per latest IS, UPVC window and Green building norms with GRIHA three star rating etc complete all as specified and as shown on drawings. (Note: The quoted rate against is deemed to included for the provisions contained in Sch 'A' Notes. Refer Sch 'A' Notes complete before quoting these items. Structural design and structural drawings for super structure and foundations for the building/structure shall be prepared to comply with the provisions for design and analysis of RCC structures as per latest editions relevant IS Codes).
Sch 'A' Part - XIII : Fittings / Fixtures & Misc items. INTERNAL WATER SUPPLY Supply and fix 15 mm bore kitchen sink tap, brass chromium plated dual flow pattern with silicon black flexible hose swivel type complete all as specified and as directed.
Supply and fix 15 mm bore washing machine tap, brass chromium plated complete all as specified and as directed.
INTERNAL ELECTRIC SUPPLY Supply and Fix Surface mounted square panel light fitting 1ftx1ft of 18W, 220Volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers suitable for roof ceiling in and including connecting up with three core flexible copper conductor cable of suitable size and connected accessories etc. complete in all as specified and as directed .
S&F TPN vertical Distribution board 8 Way, Protection class IP-43 Double door suitable for incomer MCCB suitable upto 160 Amps and outgoing MCB TPN/SP MCB with minimum 200 Amps rating bus bar etc. complete in all respects all as specified and as directed .
S&F TPN vertical Distribution board 4 Way, Protection class IP-43 Double door suitable for incomer MCCB suitable upto 160 Amps and outgoing MCB TPN/SP MCB with min 200 Amps rating bus bar etc. complete in all respects all as specified and as directed .
Supply and fix MCCB 4 Pole, 415 Volts, Adjustable Thermal & Fixed magnetic type 100Amps with breaking capacity 25 KA etc. complete in all respects all as specified and as directed.
Supply and fix MCCB 4 Pole, 415 Volts, Adjustable Thermal & Fixed magnetic type 63 Amps with breaking capacity 16 KA etc. complete in all respects all as specified and as directed .
S & F Sub main wiring complete with Four runs of 4.0 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with two run of 4.0 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including rigid nonmetallic PVC conduit and conduit accessories(Concealed in walls / roofs) etc. complete in all respects all as specified and as directed.
S & F Sub main wiring complete with Four runs of 2.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with two run of 2.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including rigid nonmetallic PVC conduit and conduit accessories(Concealed in walls / roofs) etc. complete in all respects all as specified and as directed.
S & F Sub main wiring complete with Four runs of 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with two run of 2.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including rigid nonmetallic PVC conduit and conduit accessories (Concealed in walls / roofs) etc. complete in all respects all as specified and as directed.
Supply and fix Modular TV Socket, one module etc complete in all respect all as specified and as directed .
M&L for TV Wiring with unarmored co-axial cable, RG-11 in and including concealed with PVC Conduit 25 mm dia etc complete in all respect all as specified and as directed.
Supply and fix exhaust fan/ventilation fan of 300mm sweep made of sturdy engineering steel metal body complete with louvers shutter, voltage 230V, 50Hz 1200 RPM, copper winding including writing MES no of letter height 2cm with synthetic enamel black paint etc complete in all respect and all as specified and as directed.
Supply and fix exhaust fan/ventilation fan of 250mm sweep made of sturdy engineering plastic metal body complete with louvers shutter, voltage 230V, 50Hz 1200 RPM, copper winding including writing MES no of letter height 2cm with synthetic enamel black paint etc complete in all respect and all as specified and as directed.
EXTERNAL WATER SUPPLY Cutting cast iron and reducing to required length before laying pipes in position for insertion of new tees, branches of different sizes as per site requirement for 100 mm bore complete all as directed.
Construction of valve chamber with inner clear dimension 600 x 600 x 900mm suitable for 80mm sluice Valves with PCC (1:4:8) 150mm thick type D2 for foundation, Brick masonry 230mm wall in CM (1:4), PCC (1:2:4) 75mm type B1 for coping, rendering in CM (1:4) 15mm thick including provision of 3mm thick MS sheet cover and 25 x 25 x 3mm angle frame embedded in coping with two coats of synthetic enamel paint over a coat of red oxide primer with locking arrangements including necessary earth work complete all as specified and as directed .
EXTERNAL ELECTRIC SUPPLY Taking down existing transformer of capacity 200 KVA safely from the existing platform with the help of hydra by disconnecting the existing LT/HT cables and earthing after taking proper shutdown from the Engineer in charge or his representative . Shifting of the same to the new proposed location of approx 3Km with the help of hydra and suitable load carrying vehicle and placing the same on a new platform with the help of hydra. Making the connections of HT cable, LT cable and earthing strip including testing and commissioning of transformer complete all as specified and as directed.
Material and labour for brick masonry transformer platform of size 1.5m x 1.5m with height 1.2m above GL, cement concrete in foundation of PCC 1:4:8 type D2 using 40mm graded stone aggregate, 1:3:6 PCC block masonry in cement mortar 1:4, moorum filling sand consolidating inside the brick work, sub base concrete with PCC 1:3:6 and 100mm thick top PCC 1:2:4 type B2 using 40 mm grade stone aggregate and 15mm thick (1:4) cement plaster on side walls including two coats of white wash complete all as specified and as directed.
Taking down existing diesel generating set of capacity 30KVA from the existing platform with the help of hydra by disconnecting the existing LT cables and earthing after taking proper shutdown from the department. Shifting of the same to the new location of approx 3KM with the help of hydra and suitable load carrying vehicle and placing the same on a new platform with the help of hydra. Making the connections of LT cable and earthing strip complete including testing and commissioning of DG set complete all as specified and as directed.
Returning and filling in two parts (i) using riddled soil obtain from excavated soil upto depth of 30 cm (8 cm below cable and remaining above cable) for cushioning of cable and (ii) refilling the trench of remaining depth with normal excavated soil all as specified and directed. Note:- Excavated soil shall be riddled by using sieve to separate composite particles etc as per IS 1255 1983 and refilling in trenches as in cable cushioning. In case of sufficient soil is not obtained from excavation, the quoted rate is deemed to be inclusive for the required additional qty obtain from outside MD land.
Supply Install, and commissioning LT feeder pillar Outdoor typeIP-65 made out of 3.15 mm thick MS sheet and angle Iron frame work, cubicle type with copper bus bars and with suitable mounting plate, frame and canopy, confirms to IEC61439-2 with following accessories suitable for incoming/outgoing arrangements:- (a) MCCB with extended rotary handle and spreader link 250 A 35kA 4 pole - 01 No (b) MCCB with rotary handle and spreader link 160 AMP 25kA 4 pole - 01 No (c) MCCB with rotary handle and spreader link 40 AMP 25kA 4 pole- 01 No (e) Digital panel meter for volt Amp/Volt/KWH&PF - 01 No (f) LED indicating lamp set- 01 Set of three (g) Timer Switch 20 Amps (h) Channel size 70x40x6MM suitable for LT Panel Load (j) PCC foundation as per OEM drg.
M & L for GI bracket suitable for street light fittings bend to required shape made up of dia GI tubing 40mm dia medium grade of length 1.50 Mtr including clamps nuts bolts washers complete all as specified and as directed.
Supply and fix Synchronising electronic timer unit operated on AC 230 Volts, 24 hrs clock time for controlling street lights/ flood lights etc all as directed. (Make :- Cat Part No : 4126 41 of Legrand or equivalent in makes specified in PS)
Supply and fix Power contactors 63 Amps, 4 pole, 415V etc all as directed. ( Make : Cat No 4125 57 of Legrand or equivalent in makes specified in PS)
Supply and fix junction box of size 280mm x 170mm x 130mm(cat No. GS-JB-2817 hinged (L) with aluminium bus bar bag of 50Amps for phase and neutral on porcelain based installations fixed on pole with the help of MS nuts and bolts and MS clamps 2 Nos of size 40mm x 4mm fuse with one MCB SP 6 Amps capacity mounted on rail inside box also includes making suitable hole in the pole to take out connections to fitting if required at site complete all as specified and as directed.
FIRE FIGHTING S&F Clean Agent based stand alone automated Fire Suppression system HCFC123-10 KG complete all as specified and as directed. (Make- Ceasefire/Model No.CF000771 or equivalent as approved by GE)
Supply, install, testing and commissioning terrace pump sets, centrifugal type electric driven suitable for capacity of 900 LPM and 3.5 KG/CM2 inclusive of starter and suitable PCC foundation complete all as specified and as directed.
Supply and install testing and commissioning of yard hydrant consisting of the following components complete all as specified and as directed:- (a) 63 mm dia instantaneous pattern oblique hydrant with chain cap (b) 63 mm dia size controlled peculation hose of 2 Nos 15 mtr with gun metal female instaneous coupling as necessary. (c ) Sheet steel fabricated hose cabinet of suitable size powder coat painted to house the above accessories. (d) one set of branch pipe made of gun metal.
Supply and laying of PVC insulated PVC sheathed wire armoured with multi stranded copper conductor of size 4 Sqmm 4 core 1100 volts grade complete all as specified and as directed.
Supply and fix Dry Chemical Powder (ABC) 4 KG fire extinguisher complete all as specified.
Supply and fix Light weight squeeze grip type CO2 Type Extinguisher (IS: 15683) - 3 Kg capacity complete all as specified.
Supply and fix Fire Extinguisher water (Stored pressure type) 9 Ltr capacity complete all as specified.
Supply and fix Dry chemical powder extinguisher 9 kg complete all as specified.
Supply and fix Light weight squeeze grip type CO2 Type Extinguisher (IS: 15683) - 4.5 Kg capacity complete all as specified.
Supply and fix Mechanical foam type Fire Extinguisher (IS: 15683) - 9 Ltrs capacity complete all as specified.
Supply and fix Fire Buckets-02 Nos (IS: 2546) including fire point made of PCC bed, MS pipe of 40mm dia, CGI sheet etc. complete as specified and as directed.
LIFT Supply and fix 4 Pole MCCB 63 Amp, 50 Hz, 415 V with rupturing capacity 25 KA complete all as specified and as directed.
LIGHTINING PROTECTION Supply and fix epoxy base insulators of suitable size 40mm height for fixing GI earth strip on wall/ceiling/floor/poles etc complete all as specified and as directed.
AVIATON OBSTRUCTION LIGHT Supply and fix aviation obstruction light LED type comprising of aluminium housing with polycarbonate enclosure complete all as specified and as directed. (Make Bajaj Cat No. BGAV 302 LED or equivalent as given in PS and as approved by GE)
S&F DP MCB 6 A with enclosure complete all as specified and as directed.
Supply and fix time switches 250 V single Phase of 20 Amp rating with contactor fitted inside steel enclosure complete all as specified and as directed.
SMART PREPAID METER Supply installation testing and commissioning of smart meters with prepaid metering facility, AC single, intergradation phase, two wire, 240 volts, 5o Hz, 10 to 60 Amps all as per BIS 16444:2014 (Reaffirmed 2020) with plug in type bi directional communication module (The plug in module shall be field swappable/replaceable) suitable for integration with approved communication technology GPRS/RF/Hybrid (GPRS+RF) / any other advanced technology as per CEA/TRAI regulatories etc. easily adoptable for network interface and integration with Advanced metering infrastructure (AMI) complete in all respect all as specified and as directed.
Schedule 'A' Part - XIV (Comprehensive operation including required manning of AMI system) Comprehensive operation and maintenance of AMI system including project implementation & management, all expenditure including periodic charges of telecom operator, smart meter billing and maintenance, for a period of 2 years post completion of work i.e Defects Liability Period.
Schedule 'A' Part - XIV (Outsourcing services for operation of lifts) Outsourcing man power for maintenance and operation of (01x passenger lift and 01 x goods lift) at SMQs by deploying 1 No lift operator (per shift) for 3 shift (3 Nos lift operator). Each shift shall be 08 Hrs timings 0600 Hrs to 1400 Hrs, 1400 Hrs to 2200 Hrs and 2200 Hrs to 0600 Hrs including sundays and Holidays during first year after completion of main project (Phase -I) complete all as specified and as directed. Notes:- (i) Lift operator shall have ITI certificate in the trade fitter/ mechanic / Electrician / 10+2 with minimum 3 years experience in relevant trade (ii) Necessary daily log sheet in respect of the lift shall be maintained by the operator on printed log sheet shall be provided by the contractor as approved by Engineer in charge. The cost of stationary and printed log sheet is deemed to be included in the quoted rate. (iii) To ensure working on all the days of week, relief for individuals to be provided to ensure adequate periodical breaks as required under labour laws for which cost is deemed to be included in the quoted rate. (iv) The contractor is advised to ensure all safety measures to prevent any mishaps to the labour employed in the lifts. (v) A penalty of Rs 2000/per day will be imposed on the contractor if the lift operator is found absent from duty on any day.
All as per serial item No.55 but for second year after completion of main project (Phase-I)
Schedule 'A' Part - XV (Comprehensive AMC for the lift) Comprehensive AMC for the lift through OEM during first year post defects liablity period for (01 x passenger lift & 01 x goods lifts). This includes regular inspection, servicing and maintenance of lift components, lubrication of all moving parts and cleaning of lifts shafts and pits. Schedule preventive maintenance as per OEMs recommendations replacement of worn-out parts including batteries before they fail to prevent lift breakdowns. Testing and calibrations of safety devices to ensure they function correctly, 24x7 emergency call out services to attend lift breakdowns or malfunctions.
Notes:- (i) In case of lift breakdown or malfunction, the contractor must respond within 2 hours of receiving the notification failure to respond within the specified time will result in a penalty of Rs.1000 per hour of delay. (ii) Routine maintenance visit must be carried out and any missed routine maintenance visit will incur a penalty of Rs. 500 per missed visit. (iii) Detail logs of all maintenance activities must be maintained and made available to the JE/Engineer in charge. Logs must include date and time of maintenance activities performed and parts replaced. (iv) Details reports of any breakdowns, malfunctions or safety incidents must be recorded in the logs as well as to submit the same to JE/Engineer in Charge within two hours of occurrence. The report must include the cause of the incident. Corrective actions taken and preventive measures to avoid recurrence. (v) The comprehensive AMC contractor starts after the post defects period i.e. after the two years post defects liability period. (vi) The comprehensive AMC is for both passenger lift and goods lift. Payment may be taken monthly depending upon and the fund availability. Penalty if any will be deducted from RAR/final bills.
All as per serial item 57 for but Second year after completion of Phase-II i.e After the expiry of Defects Liability Period.
All as per serial item 57 for but Third year after completion of Phase-II i.e After the expiry of Defects Liability Period.
Schedule 'A' Part - XV (Outsourcing services for operation of lifts) All as per serial item No.55 but for Third year after completion of main project (Phase-I)
All as per serial item No.55 but for Fourth year after completion of main project (Phase-I)
All as per serial item No.55 but for Fifth year after completion of main project (Phase-I)
UNITED TECHNO PROJECTS PVT LTD (BID ID -3192156)
DABAS CONSTRUCTION COMPANY (BID ID -3192179)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
recovered-award.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
155463048.pdf
Tender Document • 0.81 MB
155463050.html
Tender Document • 0.06 MB
157176379.pdf
Tender Document • 0.04 MB
157859096.pdf
Tender Document • 0.05 MB
159449273.pdf
Tender Document • 0.05 MB
159649474.pdf
Tender Document • 4.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .