| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.0 LAccepted-AOC BUDHAR ROAD SHASTRI NAGAR SHAHDOL MP | SHAHDOL | SHAHDOL | MADHYA PRADESH | 484001 | L1 | Accepted-AOC L1 bidder | |
| 2 | L2Rejected-AOC 20 7 C S M B BLOCK JANAKPURI NEW DELHI 110058 | NEW DELHI | NEW DELHI | DELHI | 110058 | L2 | Rejected-AOC L2 bidder | |
| 3 | Rejected-Technical | - | Rejected-Technical On ground of PQR clause 5a 5b Tender Cost Annex IX and tender acceptance letter |
Tender Value
₹31.4 L
EMD Value
₹62,900
Closing Date
21 Feb 2024, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE PnW o/o ED Gen Brs
SE PnW o/o ED Gen Brs
Design Engineering manufacturing supply assembly erection testing and commissioning work and retrofitting of 415 volts 3 pole electrical operated draw out type U power 400 Amp rating breaker for 4x210 Mw CHP 1 SGTPS MPPGCL Birsinghpur
2023_MPPGC_317447_1
317447
Open Tender
Miscellaneous Goods
Item Wise
90 days
SE PnW o/o ED Gen Brs
As Per NIT
19 documents required · 19 mandatory
₹1,000
Yes
₹62,900
Yes
23 Sept 2024
21 Dec 2023
23 Feb 2024
21 Dec 2023
21 Feb 2024
21 Dec 2023
Supply Part
Design, Engineering, manufacturing, supply, assembly, erection, testing & commissioning work and retrofitting of 415 volts, 3 pole electrical operated draw out type U Power 400 Amp. rating breakers for 4x210 MW, CHP-I, SGTPS, MPPGCL, Birsinghpur breakers for 400 Amp. Rating. Having microprocessor based release with inbuilt over load and short circuit protection ACB s will also have door sealing frame closing coil and shunt trip coil with facility of latest Communication capability. To retrofit supplied breakers in existing modules with door cutout power bush bar/control wiring etc. along with associated fitting /panels retrofitting in place of exiting direct on line starters MCC’s for following feeders as per scope of work and supplied ACB’s technical details. In :400A , Uimp : 12KV. , 400/415V ~ 65KA, ICW 65KA - 0.5s, 65KA -1.0s, 50/60Hz Location :- conveyor 14,15,16 & Belt feeder 1&2, 01 Spare Note : Out of 06 nos. proposed quantity 05 nos. breaker shall be retrofitted
Work Part
Retrofitting of supplied breakers in existing module, installation, commissioning & testing. Scope of work: 1. Retrofitting of supplied breakers in existing module, installation, commissioning & testing. 2. Installation of 60x06 mm, EC grade Copper busbar with PVC coloured heat-shrinkable sleeves (45 Mtrs approx.), 3. Installation of Current transformer 400/5A, class 5P10, tapped (15 Nos approx.), 4. Installation of IDMT relay 230VAC, 5A, 50,50N, 51,51N protection with communication (5 Nos approx.), 5. Installation of 2.5 Sq mm single copper flexible cable (90 mtrs approx.) 6. Installation of 1.5 Sq mm single copper flexible cable (90mtrs approx.) 7. Installation of 6A SP 10kA C curve MCB for Control (24 nos approx.), 8. installation of LED indication lamp 240V AC for Phase indication and on, off (25 Nos approx.), 9. Installation of 40x06mm MS Angle for ACB mounting (82 Kg approx. 10. Installation of 2.5sqmm disconnecting CT terminal (50 Nos. approx.), 11. Installation of Nut bolt washer miscellaneous (1 lot approx.) NOTE- In the instant tender, the existing module is to be converted into 415V breaker therefore it is advised to visit the site and make himself conversant before participation in the bid and signed MOM with site authorities to avoid any dispute at any stage.
MASTER ENGINEERING SERVICES
MASTER ENGINEERING SERVICES
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .