EE(CD-III), East Campus Maintenance (Residential Area Maintenance) , IIT DELHI
Name of work- Construction of temporary faculty rooms, labs, corridors and toilets in the Gramodaya Parisar at IIT Delhi. Sub Head- Civil, Electrical, Air conditioning and CCTV works
2021_IIT_618868_1
IITD/ WORKS(SP-3400) /2021
Open Tender
Civil Works
Works
550 days
IIT Delhi, Hauz Khas, New Delhi
As per tender document
16 documents required · 16 mandatory
₹1,500
ragistrar IIT Delhi
Exempted
1 Apr 2021
25 Feb 2021
17 Mar 2021
25 Feb 2021
16 Mar 2021
25 Feb 2021
Amount
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m : All kind of soil
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m: All kinds of soil
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil : Pipes, cables etc, not exceeding 80 mm dia.
4) Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
5) Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Supplying chemical emulsion in sealed containers including delivery as specified. : Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to the full depth of the hole : With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
8) Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size)
9) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size
PProviding and laying in position ready mixed plain cement concrete, with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. Note : 1) Excess/less cement used than specified in this item is payable/recoverable separately. :All works upto plinth level : M-10 grade plain cement concrete (cement content considered @ 220 kg/cum)
Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately). : All works upto plinth level
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level :Thermo-Mechanically Treated bars of grade Fe-500D or more
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. : Granite of any colour and shade : Area of slab over 0.50 sqm
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete.
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 300x16 mm
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 250x10 mm
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. : Twin rubber stopper
Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer.
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. : Hot finished welded type tubes. Note :- For design of truss detailed structural design by any structural designer and duly vetted by NIT/IIT will be submitted by the agency . The Sucesfull bidder esentially submit the detailed structural design within a week from the date of issue the award letter which will be than vetted by NIT/IIT & agency will also be submit the stability report duly examined & issued by NIT/IIT. All above work will be in the scope of sucessful bidder & nothing extra will be paid on account of structural design.
Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.: Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing and fixing thermal insulation with Resin Bonded Fibre glass wool conforming to IS: 8183 having density 24 kg/m3, 50 mm thick, wrapped in 200G Virgin Polythene Bags fixed to wall with screw, rawel plug & washers and held in position by criss crossing GI wire etc. complete as per directions of Engineer-in-Charge.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. : 110 mm diameter
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm)
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Gutter (600 mm over all girth)
35) Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
35.1) GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer’s specification. Two or more coats on new work
37) Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
38) Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
39) 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand)
40) 15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand)
41) Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
42) Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge
43) Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
44) Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
45) Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge.
46) Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe: 32 mm dia
47) Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 1500x450 mm
48) Providing and fixing soil, waste and vent pipes : 100 mm dia Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989
49) Providing and fixing soil, waste and vent pipes : 75 mm dia Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989
50) Providing and fixing plain bend of required degree. 100 mm dia: Sand cast iron S&S as per IS : 3989
51) Providing and fixing plain bend of required degree. 75 mm dia, Sand cast iron S&S as per IS - 3989
52) Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 100x100x100 mm : Sand cast iron S&S as per IS - 3989
53) Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete : 75x75x75 mm : Sand cast iron S&S as per IS - 3989
54) Providing and fixing terminal guard : 100 mm Sand cast iron S&S as per IS - 3989
55) Providing and fixing collar : 75 mm : Sand cast iron S&S as per IS - 3989
56) Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter : 100 mm
57) Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter :75 mm
58) Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 100 mm outlet: Sand cast iron S&S as per IS: 3989
59) Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 75 mm outlet : Sand cast iron S&S as per IS - 3989
60) Providing & fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology
61) Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
62) Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. : 40 mm dia nominal bore
63) Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 25 to 40 mm nominal bore
64) Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.: 25 mm dia nominal bore
65) Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : : 15 mm dia nominal bore
66) Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall :20 mm dia nominal bore
67) Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 20 mm nominal bore
68) Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore
69) Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 40 mm nominal bore
70) Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) :20 mm nominal bore
71) Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 40 mm nominal bore
72) Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) 15 mm nominal bore
73) Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) :25 mm nominal bore
74) Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 100 mm diameter
75) Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : 100 mm diameter S.W. pipe
76) Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 100x100 mm size P type : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
77) Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 Fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
78) Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : For pipes 100 to 250 mm diameter
79) Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :250 mm dia. R.C.C. Pipe
80) Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
81) Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
82) Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion : Powder coated aluminium (minimum thickness of powder coating 50 micron)
83) Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free,straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) : Powder coated aluminium (minimum thickness of powder coating 50 micron)
84) Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge .(Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm)
85) Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540- F & ISO 11600: Upto 20 mm depth and 20 mm width
86) Providing and fixing 100mm C.P. grating with or without hole for nahani trap/floor trap of approved make and as per directions of Engineer-In-Charge.
87) Providing and fixing factory made hot pressed both side laminated flush door ready made shutter with one mm thick decorative laminate on both side confirming to IS:2202 (Part-I) non decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grain or cross bands and face veneer on both face of shutters.: 35mm thick including ISI marked stainless steel butt hinges with necessary screws.
88) Providing and fixing C.P. brass angle valve/angular stop cock for wash basin and geyser and WC points of approved quality complete as per the direction of Engineer in-charge.(Make - Jaquar (Fusion series)/ Roca- (Victoria Series) or equivalent of Kohler)
1.11) Providing and fixing 10 mm thick non - asbestos multipurpose cement board rainforced with cellulose fiber manufactured through autoclaving process ( high pressure steam cured ) as per IS:14862 of Everest industries Ltd or equivalent make , over the exidting MS frame work ( to be paid in basic items ) with 25 mm counter sunk ribbed hard screws @200m center to center.
1.9) Providing and fixing 50 mm thick sandwich roof puff panel (factory made only) as per specification as follow. A) trapezoidal steel sheet having minimum 30mm crest depth, polyester top coat & alkyd backer. Zinc coating shall be 120g/sqm as per IS-277. Top coat polyester 15-18 microns over 5-7 micron epoxy primer. b) Insulation: High density puff insulation. c) Inner sheet: Colour coated galvanized slightly ribbed. Thickness 0.50mm (TCT) minimum 15-18 micron top coat polester coation, zinc coating 120g/sqm as per IS-277
Providing and laying unglazed matt finished heavy duty homogenous body 10mm thick vitrified tiles having water absorption less than 0.5% and confirming to IS-15622 & IS.-of size- 600x600 mm of approved make and brand (Somany STONE 10 series or equivelent) laid on 20 mm thick base on cement mortar 1:4 (1 cement : 4 Coarse Sand)/ 6 mm thick (Avg.) base cement based high polymer modified quick set tile adhesive (water based) confirming to IS- 15477, including grouting of joints with white cement and matching pigment etc. complete as per direction of Engineer-in-Charge.
92) Providing and Fixing of CP Brass bib cock (Short body) of approval quality complete as per the direction of Engineer in-charge. (Make - Jaquar/Marc/Kohler)
93) Providing and fixing 18 mm thick WPC (wooden polymer composit) board inside shelves, sides, back portion or in drawer units etc. for specific size and 18 mm thickness, composed of wood dust (min 30% - 40% and remaining PVC, fungus/Acid/termite/water proof , fire retardent, formaldehyde free, virgin thermoplastic,single Extruded and screw-able/nail-able, having density of 680 - 720 kg/cum. and water absorption up to 1 % with approved make with necessary fixing arrangement and as per requirement complete as per direction of Engineer in charge.
94) Providing and fixing wash basin with C.I./M.S. brackets, 32mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. : Oval shaped counter top wash basin (Size - 560mm x 400mm)
95) Providing and fixing C.P. Health Faucet with 1 Mtr long tube & Hook complete as per the direction of Enginere- in-charge. (Make - Jaquar (Fusion series)/ Roca- (Victoria Series) or equivalent of Kohler)
96) Providing and fixing fire resistance Roller blinds of 400 GSM (make VISTA or equivalent ) with anodized aluminium channel weight, chord, runners, end caps, hangers and chain etc.
97) Supply and installation of reqired size, shape, design and colour Table 1650 mm wide (as per enclosed drawing) as per approved make and direction of Engineer- in-charge. (Make-Godrej Model No.- ARISTO Back unit 750H (W= 1650mm,D=500mm,H=750mm ) /equivalent of Featherlite/ equivalent of Wipro, In this estimate , Godrej Interio's "ARISTO Back unit 750H Model" in Table 1650 mm wide series has been considered. In case of other makes, technical specifications should be equivalent and cost adjustment shall also be done if the equivalent make is of lesser market price than Godrej Interio)
98) Supply and installation of reqired size, shape, design and colour Chair (as per enclosed drawing) as per approved make and direction of Engineer- in-charge. (Make-Godrej Model No.- Marvel HB Chair /equivalent of Featherlite/ equivalent of Wipro, In this estimate , Godrej Interio's "Marvel HB Chair Model" in Chair series has been considered. In case of other makes, technical specifications should be equivalent and cost adjustment shall also be done if the equivalent make is of lesser market price than Godrej Interio)
99) Supply and installation of reqired size, shape, design and colour Visitor Chair (as per enclosed drawing) as per approved make and direction of Engineer- in-charge. (Make-Godrej Model No.- Marvel Visitor Chair / equivalent of Featherlite/ equivalent of Wipro, In this estimate , Godrej Interio's "Marvel Visitor Chair Model" in Visitor Chair series has been considered. In case of other makes, technical specifications should be equivalent and cost adjustment shall also be done if the equivalent make is of lesser market price than Godrej Interio)
100) Supply and installation of Glass Door Storewell shall have an overall size of 916mm(W)x486mm(D)x1980mm(H) with welded construction. It should have shelf thickness of 0.7 mm, Back thickness of 0.8mm, Door thickness of 0.8mm (high yield strength) and all other components shall have a thickness of 0.9mm. These components shall be made of CRCA ‘D’ grade high yield strength as per IS:513. The glass door storwel shall have a brass handle and a 2 way locking mechanism with shooting bolt . It should have a height wise adjustable shelf mounting which shall have a Uniformly Distributed Load Capacity of max 40 Kg. It should also have a M10 Screw type Leveller with Hex plastic base. The finishing shall include Epoxy powder coated to the thickness of 50 microns (+/- 10). Plenty of colour options and shelving options as decided by Engineer-in-charge. In this estimate , Godrej Interio's "Glass Door Storewell Model" in Storewell series has been considered. In case of other makes, technical specifications should be equivalent and cost adjustment shall also be done if the equivalent make is of lesser market price than Godrej Interio)
101) Top Panel :Made of 25mm thick MDF one side pre-laminate board confirming to IS-14587:1998 with 0.4mm PVC membrane pressed on to top Slide Door Unit: Made of 25mm Thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping for body panels like side, bottom,back and shelves. Shutters are made of 25mm thick MDF one side pre-laminate board confirming to IS-14587:1998 with 0.4mm PVC membrane pressed on to top. Shutters have a soft closing & anti slam mechanism. Handles are provided for ease of opening. Storage is provided with lock for security. In this estimate , Godrej Interio's "Aristo Bckunt 1650 W 750H (1650x500x750) Model" in Backunit series has been considered. In case of other makes, technical specifications should be equivalent and cost adjustment shall also be done if the equivalent make is of lesser market price than Godrej Interio)
102) Providing services of a Computer Operator cum supervisor for utilization of computer installed in the office of the Executive Engineer during the office hours for day to day work on 22 working days in a month. The person to be employed for this job should have working experience of M.S. Word, M.S. Excel & Esta as required for preliminary estimate, detailed estimate, justification, NIT, E.I.S, D.I.S preparation of monthly reports, quarterly report for various categories of works, financial progress report, letters, budget report etc. and update the works information system. (The rate should be quoted inclusive of all satutory payments & all other applicable Government taxes if any).
103) Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
103.1) Group C
104) Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
104.1) Group C
105) Wiring for light/ power plug with 2X4 sq.mmFRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 1 No 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as reqd.
106) Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
107) Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required
107.1) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
107.2) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
107.3) 2 X 10 sq. mm + 1 X 6 sq. mm earth wire
107.4) 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
107.5) 4 X 6 sq. mm + 2 X 6 sq. mm earth wire
107.6) 4 X 10 sq. mm + 2 X 6 sq. mm earth wire
108) Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.
108.1) 3 x 4 sq. mm
108.2) 6 x 4 sq. mm
109) Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
109.1) 5/6 A switch
109.2) 15/16 A switch
109.3) 3 pin 5/6 A socket outlet
109.4) 6 pin 15/16 A socket outlet
110) Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
111) Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
111.1) 6 Module (200 mmX75 mm)
111.2) 12 Module (200 mmX150 mm)
112) Supplying and fixing following size/ modules, PVC box alongwith modular base & cover plate for modular switches in recess etc. as required.
112.1) 6 Module (200 mmX75 mm)
112.2) 12 Module (200 mmX150 mm)
113) Supplying & fixing suitable size GI box with modular plate & cover in front on surface or in recess, including providing & fixing 3 pin5/6 amps modular socket outlet & 5/6 amps modular switch, connection etc. as reqd.
114) Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
115) Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
115.1) 125 A, 16 kA,TPMCCB
116) Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
116.1) 8 way, Double door
116.2) 12 way, Double door
116.3) 16 way, Double door
117) Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer MCCB) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
117.1) 4 way (4 + 12), Double door
117.2) 8 way (4 + 24), Double door
117.3) 12 way (4 + 36), Double door
118) Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
118.1) Single pole
118.2) Triple pole
119) Supplying and fixing following rating, double pole, 240 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required.
120) Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
121) Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
122) Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
123) Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
123.1) 200 mm width X 50 mm depth X 1.6 mm thickness
124) Supplying and fixing 63A, 415 V, 5 pin Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 63A "C" curve, TPNMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
125) Providing and fixing M.S. Fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. Rate to be taken
126) Supplying and Fixing DLP U-PVC turnking of 105mm x 50mm on surface etc as required.
127) Supplying and Fixing Full Flexible cover of width 85mm on existing DLP U-PVC turnking etc as required.
128) Supplying and Fixing of 90ͦ flat angle in existing DLP U-PVC turnking etc as required.
129) Supplying and Fixing of End cap on existing DLP U-PVC turnking etc as required.
130) Supplying and Fixing 3 module support for 85mm cover etc as required.
131) Supplying and Fixing 6 module support for 85mm cover etc as required.
132) Supplying and fixing following modular switch/ socket on the existing U-PVC trunking system including connections etc. as required.
132.1) 10 A switch
132.2) 20 A switch
132.3) 3 pin 10 amp socket outlet
132.4) 6 pin 20 A socket outlet
133) S/I/T/C of 1200 mm size (5 star) of double ball bearing,copper winding, capacitor start Ceiling fan of approved make suitable for 230 volt, 50 Hz, sigle phase A.C. supply and complete with all standard accessories such as Motors, Blades & Capacitor, fan box cover i/c wiring the down rod with 1.5 sq.mm FRLS copper conductor wires from the point outlet etc complete as required.
134) S/I/T/C of 1400 mm size of double ball bearing,copper winding, capacitor start Ceiling fan of approved make suitable for 230 volt, 50 Hz, sigle phase A.C. supply and complete with all standard accessories such as Motors, Blades & Capacitor, fan box cover i/c wiring the down rod with 1.5 sq.mm FRLS copper conductor wires from the point outlet etc complete as required.
135) S/I/T/C of 12"(300mm) size,1400rpm,copper wound, heavy duty metalic Exhaust Fan of double ball bearing capacitor start,suitable for 230 volt,50 Hz,single phase A.C. supply and complete with accessories such as motor, legs,frame,loober and Nut & bolts etc complete as required
136) S/I/T/C of 10"(250mm) size,copper wound, ventiling fresh air fan of double ball bearing capacitor start,suitable for 230 volt,50 Hz,single phase A.C. supply and complete with accessories such as motor, legs,frame,loober and Nut & bolts etc complete as required.
137) S/I/T/C of Recess/ Surface mounting LED luminaire equipped with CRCA powder coating housing, anti glare polycarbonate diffuser with energy efficient electronic driver with following features:- Suitable for operating voltage and frequency: 130-300 Va.c, 50 Hz.; wattage not more than 34 Watts;Output lumens not less than 3300 lm; CCT 6500K; Dimension in mm (595X595X70); Nominal surge protection 2.5 kV;Power factor not less than 0.9; Minimum IP protection 20;
138) S/I/T/C of 18 watt LED batten with its coextrusion polycarbonate construction & Integrated electric driver IP20 protection, 6500k.
139) S/I/T/C of 12 watt Surface mounted LED with its coextrusion polycarbonate construction & Integrated electric driver IP20 protection, 6500k.
140) S/I/T/C of 60watt LED Floodlight equiped with Aluminium die cast housing luminaire and toughened glass with silicon gasket for IP66 protection. Suitable for operation 230 volt,50Hz and output lumens not less than 6000lm etc as required.
141) Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
142) Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
143) Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
144) Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
145) Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
146) Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE Aluminium power cable of 1.1 KV grade of following size direct in ground including excavation,sand cushioning,protective covering and refilling the trench etc as required.
146.1) Above 35 sq. mm and upto 95 sq. mm (3.5C x 95 sq.mm)
146.2) Above 95 sq. mm and upto 185 sq. mm (3.5C x 150 sq.mm)
147) Supplying & Laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium power cable of 1.1 kV grade of following size on wall surface as required.
147.1) Upto 35 sq. mm (3C x 25 sq.mm) (clamped with 1mm thick saddle)
147.2) Upto 35 sq. mm (3.5C x 35 sq.mm) (clamped with 1mm thick saddle)
147.3) Above 35 sq. mm and upto 95 sq. mm (3.5C x 50 sq.mm) (clamped with 25x3mm MS flat clamp)
148) Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
148.1) 3 X 25 sq. mm (25mm)
148.2) 3½ X 35 sq. mm (32mm)
148.3) 3½ X 50 sq. mm (35mm)
148.4) 3½ X 95 sq. mm (45mm)
148.5) 3½ X 150 sq. mm (50mm)
149) Supplying, Installation, Testing & Commissioning i/c making foundation of cubical type Feeder Pillar Double Door Outdoor Type suitable for 415V, 3 Phase, 4 wire 50 Hz AC supply system, fabricated in compartmentalized (preferably) design from CRCA sheet steel of 2mm thick for frame work and covers, 3mm thick for gland plates i/c cleaning & finishing complete with for powder coating for prickling and degreasing in approved shade, having 500 amp capacity extensible type TPN Aluminium Alloy bus bars of high conductivity, DMC/SMC bus bars supports with short circuit withstand capacity of 31 MVA for 1 sec., bottom base channel of MS section not less than 100mm x 50mm x 5mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of AL. bus bars and control wiring with 2.5 sq.mm PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears.Size of Feeder Pillar : 1.0 mtr x 0.9 mtr x 300mm deep.
Incomer
1 Nos. 400 Amps. FP MCCB of 36 KA with inbuilt protection.
MAIN BUS BARS
TPN aluminium bus bars of minimum of 500 Amps capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 sec.
METERING
iii) 3 Nos. phase indication lights LED type with protection MCB.
OUTGOINGS
i) 2 Nos. 250 Amps. FP MCCB of 25 KA with inbuilt protection.
ii) 2 Nos. 160 Amps. FP MCCB of 25 KA with inbuilt protection.
Total Panel Cubical Type Feeder Pillar AS DESCRIBED ABOVE.
150) Supplying, Installation, Testing & Commissioning i/c making foundation of cubical type Feeder Pillar Double Door Outdoor Type suitable for 415V, 3 Phase, 4 wire 50 Hz AC supply system, fabricated in compartmentalized (preferably) design from CRCA sheet steel of 2mm thick for frame work and covers, 3mm thick for gland plates i/c cleaning & finishing complete with for powder coating for prickling and degreasing in approved shade, having 300 amp capacity extensible type TPN Aluminium Alloy bus bars of high conductivity, DMC/SMC bus bars supports with short circuit withstand capacity of 31 MVA for 1 sec., bottom base channel of MS section not less than 100mm x 50mm x 5mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of AL. bus bars and control wiring with 2.5 sq.mm PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears.Size of Feeder Pillar : 1.0 mtr x 0.9 mtr x 300mm deep.
INCOMER
1 Nos. 250 Amps. FP MCCB of 36 KA with inbuilt protection.
MAIN BUS BARS
TPN aluminium bus bars of minimum of 300 Amps capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 sec.
METERING
iii) 3 Nos. phase indication lights LED type with protection MCB.
OUTGOINGS
i) 4 Nos. 160 Amps. FP MCCB of 25 KA with inbuilt protection.
Total Panel Cubical Type Feeder Pillar AS DESCRIBED ABOVE.
C) FIRE ALARAM SYSTEM
151) Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required.
152) Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.
153) Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as require
154) Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required
155) Supplying & laying and fixing of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
156) Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
157) Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
158) Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required.
159) Supply & Fixing 1080p 2 MP IP Network TDN Low-Light IR Bullet Camera, 1/2.7" CMOS, 2 MP @ 25fps, triple stream, Min. Illumination required 0.01 lux @ F1.4 (color), 120dB True WDR, Min. Pixels 1920 × 1080, triple stream, 2.7–12 mm motorized focus & zoom lens, BLC, HLC, 3DNR, Privacy Mask, 4 IR LEDs Smart IR with upto 60m IR distance, Dual channel Audio G.711a/G.711u/AAC, 128GB SD card support, Alarm: 2 In/ 1out, PoE, H.264 High Profile and MJPEG, PoE Class 3 and 12V DC, IP 67, IK 10 vandal proof, Having Operating temp range : – 40°C to 60° C. Certifications: ONVIF Profile S & Profile G compliant, UL, CSA 60950-22, CE (EN 50130-4 & EN 55022) , FCC Part 15 & RoHS compliant. Approved Makes MAF/Letter of Authorization from original equipment manufacturer (OEM) on the same and specific to the tender should be enclosed.
160) Supply & Fixing of 32 Channel NVR with Dualcore embedded processor, Embedded LINUX, BIDIRECTIONAL AUDIO 1 channel input; 1 channel output; RCA, RESOLUTION 1920 x 1080; 1280 x 1024; 1280 x 720; 1024 x 768, OSD Camera title; Time; Video loss; Camera lock; Motion detection; Recording, COMPRESSION H.264 / MJPEG, BIT RATE* 48 to 8192 Kbps, RECORDING MODE Manual; Schedule (Regular [Continuous], Motion Detection, Alarm, Motion Detection+Alarm); Stop, SUPPORTED PROTOCOLS** HTTP; TCP/IP; IPv4/IPv6; UPnP; RTSP; UDP; SMTP; NTP; DHCP; DNS; IP filter; PPPoE; DDNS; FTP; Alarm server; IP search, ETHERNET 1 x RJ-45 port (10/100/1000 Mbps, USB 2 ports: USB 3.0 on rear panel; USB 2.0 on front panel. The proposed system should provide 15 days recording. Approved Makes NVR & Cameras should be from the same make only.
161) Supply & Fixing of Layer -2 Switch with Power on Ethernet (PoE) enabled, with 24 port. 10/100/1000 base Tx PoE port, 1 no. dual personality Gbe Port for copper/fiber uplink, 3.7 Gbps switching capacity, 2.7 MPPS forwarding rate, maximum power consumption 135 watt. Approved Makes
162) Supply & Fixing of Layer -2 Switch with Power on Ethernet (PoE) enabled, with 8 nos. 10/100/1000 base Tx PoE port, 1 no. dual personality Gbe Port for copper/fiber uplink, 3.7 Gbps switching capacity, 2.7 MPPS forwarding rate, maximum power consumption 135 watt. Approved Makes
163) Supply & Fixing of 24 port jack panel. Approved Makes
164) Supply & Fixing of 17U rack for switch Mounting with Fan and power Strip, PDU, Hardware Mounting Kit. Approved Makes
165) Supply & Fixing of 6U rack for switch Mounting with Fan and power Strip, PDU, Hardware Mounting Kit. Approved Makes
166) Supply & Fixing of 42" LED Monitor, Full HD, HDMI Port, Component Video Inputs, 1 Digital Audio Out, VGA, Port. Approved Makes
167) Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
167.1) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
168) Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
168.1) 1 run of cable
168.2) 2 run of cable
169) Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
169.1) 63 mm dia (OD-63 mm & ID-51 mm nominal)
170) Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
171) Supply & Fixing of 1 mtr patch cord.
172) Supply & Fixing of 3 KVA UPS INVERTOR With 30 Minutes Backup. Approved Makes
173) Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at 43 Degree C ambient and work even at 50 Degree C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions (35 deg C) at 50% load shall not be less than 6.4 and IEER not less than 6.5 (Make: Bluestar / LG / Carrier / Toshiba / Mitsubishi / Hitachi)
174) Supply, installation, testing and commissioning of following minimum capacity VRV/VRF High wall type Indoor unit equipped with washable synthetic media pre - filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V +/- 10%, 50 Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. (same as outdoor unit)
175) Supply, Installation, testing and commissioning including vaccumisation and nitrogen testing of following nominal sizes of soft / hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, Y-type joints wherever required, with adjustable with ring type hanger supports, jointing / brazing including accessories, insulated with XLPE class - O tubular insulation / with Class-O closed cell elastomeric nitrile rubber tubular sleeves sections of specified thickness as given below for suction and liquid lines, all accessories as per specifications etc. as required:
175.1) NOTE: (1) The copper piping and piping circuit should be with minimum number of joints, which shall be attained by: (a) Using one end expanded tubes (b) bending the tubes instead of using elbow joints wherever 90 degree bending is required (2) Piping should be routed at site in such a manner, that brazed joints in the refrigeration piping are kept to a minimum (3) The makes of tube fittings shall be same as that of tubes (4) The thickness of fittings used shall be same as that of the pipe
175.2) 9.5 mm dia (OD) (soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
175.3) 12.7 mm dia (OD) (soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
175.4) 15.86 mm dia (OD) (soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
175.5) 19 mm dia (OD) (hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
175.6) 22.2 mm dia (OD) (hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
175.7) 25.4 mm dia (OD) (hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
175.8) 28.58 mm dia (OD) (hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
175.9) 34.9 mm dia (OD) (hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
176) Supplying and installing following size of perforated Hot Dipped Galvanised Iron Cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5% in convenient sections, joined with connectors, suspended from the ceiling / steel truss as available with GI suspenders including GI bolts and nuts, etc. as required.
176.1) 225 mm width x 50 mm depth x 1.6 mm thickness
177) Supplying and laying of ISI marked CPVC pipe of 32 mm dia for draining of sweated water from AC evaporator unit including providing tee, joints, elbows, supports, etc. with thermal insulation wherever necessary etc. complete as required.
178) Fabricating, Providing and fixing M.S. iron frame fabricated with M.S. C-channel of size 100 mm x 50 mm x 6 mm (thick) for resting the condenser unit on the roof / floor of the building duly supported from the bottom as required including painting the framework etc. complete as required.
179) Supplying and laying of ISI marked FR pvc insulated flexible copper cable of size 2 core x 1.5 sqmm of 1.1 kv grade including making connection etc. for communication between indoor and outdoor unit and other units, etc. through conduit complete as required.
180) Supplying and laying of following size pvc insulated pvc sheathed XLPE armoured copper conductor cable of 1.1 kV grade including making connections etc. as required.
180.1) 3 core x 2.5 sqmm
181) Supplying and laying of following size pvc insulated pvc sheathed XLPE armoured aluminium conductor cable of 1.1 kV grade direct in ground including excavation, sand cushioning, protective covering and refilling the trench including making connections etc. as required.
181.1) 3.5 core x 35 sqmm
182) Supplying and making end termination with brass compression gland and tinned copper lugs for following size of pvc insulated and pvc sheathed / XLPE copper conductor cable of 1.1 kV grade as required.
182.1) 3 core x 2.5 sqmm
183) Supplying and making end termination with brass compression gland and aluminium lugs for following size of pvc insulated and pvc sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
183.1) 3.5 core x 35 sqmm
184) Providing and fixing 8 SWG dia GI wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required.
185) Supplying and fixing of 2 way rectangular sheet steel MCB enclosure duly phosphatised, powder painted complete with Din rail, in accordance with IS 13032, IS 8623, IEC/BS EN 60439-3 including SPN MCB of 5/10 amps etc. complete as required. (Reference similar product: Havells Cat No. DHDESDP)
186) Providing and laying in position cement concrete 1:3:6 (1 cement : 2 coarse sand : 6 graded stone aggregate 40 mm nominal size) in foundation of VRF Condenser unit etc including form work etc as required.
AMC PART (Supplementary agreement shall be formed) under ARMO Fund
187) Routine, Preventive and Breakdown maintenance of VRF/VRV AC units including its all accessories, condensers, evaporator units, time to time checking of refrigerant leakage, electrical circuits, etc. for smooth operation of the entire AC units during the defect liability period of 1 year after date of commissioning as per maintenance schedule. (Completely free of cost): 1st Year – 01 Job
188) Routine, Preventive and Breakdown maintenance of VRF / VRV AC units including its all accessories, condensers, evaporator units, time to time checking of refrigerant leakage, electrical circuits, etc. for smooth operation of the entire AC units after defect liability period of 1 year from the date of commissioning as per maintenance schedule. Any breakdown shall be attended within 4 hours of reporting. Spare parts required during breakdown maintenance shall be arranged by the Institute. (N.B.: 01 Job means during a period of one year)
188.1)2nd year
188.2) 3rd year
188.3) 4th year
188.4) 5h year
188.5) 6th year
KBG ENGINEERS
RAJENDRA MITTAL CONSTRUCTION CO. PVT. LTD.
Confoss Construction
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .