Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.4 LAccepted-AOC PLOT NO 81 SHANTAJI COLONY JANKI NAGAR JABALPUR MP PIN 482002 | JABALPUR | MADHYA PRADESH | 482002 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹37.6 L+₹75,136.80 (2.04%)Rejected-Finance 00 PANCHARIYA NEAR SANTOSHI MATA TEMPLE MAHARASHI GOUTAM MARG NEW LINE GANGASHAHAR BIKANER BIKANER BIKANER RAJASTHAN 334401 | BIKANER | RAJASTHAN | 334401 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹41.5 L+₹4.7 L (12.6%)Rejected-Finance 1814 NARSING NAGAR RANJHI JABALPUR MP 482005 | JABALPUR | JABALPUR | MADHYA PRADESH | 482005 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹42.2 L+₹5.3 L (14.3%)Rejected-Finance A BLOCK 302 SHRIFAL RESIDENCY JANTANAGAR PARSHWANATH NAGAR GANDHI NAGAR GUJARAT 382424 UDYAM GJ 09 0033153 | AHMADABAD | GUJARAT | 382424 | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹43.8 L+₹6.9 L (18.8%)Rejected-Finance HO SR NO 73 TAPKIR MALA CHOWK TAPKIR NAGAR KALEWADI PIMPRI PUNE 411017 | PUNE | MAHARASHTRA | 411017 | L5 | Rejected-Finance Being L5 |
Tender Value
₹48.0 L
EMD Value
₹95,900
Closing Date
10 Jun 2020, 6:00 pmClosed
GE (I) (P) Fy Jabalpur
GE (I) (P) Fy Jabalpur PO-Khamaria PIN-482005
REPAIR COMPREHENSIVE MAINTENANCE TO INTERNAL ELECTRIFICATION INCLUDING REPLACEMENT OF CONVENTIONAL LIGHT FITTINGS TO LED FITTINGS IN DOMESTIC AND RESTRICTED AREA OF DGQA UNITS AT GCF, VFJ, OFK AND LPR AREA JABALPUR
2020_MES_345305_1
8322/KH/E8
Open Tender
Civil Works
Item Rate
330 days
Jabalpur
As per eNIT
7 documents required · 7 mandatory
₹500
GE (I) (P) Fy Jabalpur
₹95,900
Yes
27 Aug 2020
16 May 2020
15 Jun 2020
16 May 2020
10 Jun 2020
30 May 2020
Amount
Supply, install, testing and commissioning of LT distribution panel, CPRI approved, weather/vermin proof, made out of 3 mm thick CRCA sheet, factory assembled cubicle pattern modular and compartmentalized construction, outdoor type, with front and backside hinged double door with locking arrangement, floor mounted free standing type, duly powder coated, 3 phase and neutral 400 amps current carrying capacity aluminium bus bar with epoxy insulated coating with colour code and insulated support with aluminium earth bus of size 25x3mm with terminal switch, cable gallery, inter connecting bus bar connection/linkage complete and comprising of following switch gears and mounting panel board on ground with PCC (1:3:6) bedding upto a height of 30 cm above gorund level including dismantling and taking out old u/s LT Panel Board and remove from site reconnecting existing LT Cables with new panel board complete all as directed :-
(a) MCCB, 415 Volt, 4 pole, of capacity 160 Amps, with adjustable thermal and fixed magnetic setting, 36 KA - 1 Nos.
(b) MCCB, 415 Volt, 4 pole, of capacity 63 Amps, with adjustable thermal and fixed magnetic setting, 25 KA - 4 Nos
(d) Ammeter digital type with CT for three Phase 0-300 Amps with selcetor switch - 1 Set
(e) LED indication lamps with backup MCB for 3 phase supply –1 set.
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below ground level, connecting GI strip of size 32mm x 6mm from earth plate to body of the equipment by means of bolts, nuts, check nuts and washers of galvanised iron or steel, 40 mm bore GI light grade pipe for protection of earth lead from earth plate(6 mtrs long), 20 mm GI light grade watering pipe, PCC 1:3:6 type C-2 (using 40mm graded stone aggregates) as in earhing pit, PCC cover, charcoal or coke & salt filling and necessary excavation and earth work and all other relevant works including testing all as specified and shown in electrical plate No.3 of MES Schedule part-I.
Supply, install, testing and commissioning of LT distribution panel, CPRI type tested, weather/vermin proof, made out of 2 mm thick CRCA sheet, factory assembled cubicle pattern modular and compartmentalized construction, Indoor type, with front side hinged door with locking arrangement, floor mounted free standing type with base frame, provided with gasket for all the doors & removable covers, duly powder coated, 3 phase and neutral 600 amps current carrying capacity aluminium bus bar with heat shrinkable PVC sleeve insulated coating with colour code and insulated support with aluminium earth bus of size 25x3mm with terminal switch, cable galleries, inter connecting bus bar connection/linkage complete and comprising of following switch gears and mounting panel board on floor including dismantling and taking out old u/s LT Panel Board and remove from site reconnecting existing LT Cables with new panel board complete all as directed :-
(a) MCCB, 415 Volt, 3 pole, of capacity 400 Amps, with adjustable thermal and fixed magnetic setting, 36 KA - 1 No.
(b) MCCB, 415 Volt, 3 pole, of capacity 100 Amps, with adjustable thermal and fixed magnetic setting, 25 KA -9 Nos
(c) Star delta starter, fully automatic complete with all accessories, 3 phase, air coooled, panel mounted, open execution type, 415 Volt, suitable for 7.5 HP pump set, with on/off push button in the front panel - 9 Nos
(e) Ammeter with CT for three Phase 0-100 Amps with selcetor switch - 9 Nos
(f) LED indication lamps in in/out going.
Supply and Fixing in repairs, Post top lantern luminaire comprises of die-cast aluminium flat top cover canopy, with aluminium reflector, translucent UV protected polycarbonate diffusers, with B22 Lamp holder and LED retrofit lamp 12 watts, B-22, 230 Volt, including GI Pipe of suitable size for mounting the lantern, duly errected on compond wall/pillars, with Cable entries for through-wiring of mains supply cable, Protection class IP54, Suitable for operation on 240V, 50Hz single phase ac supply Complete all as directed.
S & F in repairs Weather proof street light junction box Made of FRP of size not less than 20 x 20 x 15 cm depth including MCB, TPN, 10 Amps-1 No and MCB, SP, 6 Amps -1 No and connecting terminals 4 way including necessary Clamps made out of MS flat iron, nuts and bolts suitable for fixing on wall complete all as directed.
S & F in repairs Weather proof street light junction box Made of FRP of size not less than 15 x 15 x 15 cm depth including MCB, SP, 6 Amps -1 No and connecting terminals 4 way including necessary Clamps made out of MS flat iron, nuts and bolts suitable for fixing on wall/Pole complete all as directed.
S& F in repairs two single core PVC insulated cables 2.5 Sqmm size, 1100 Volt grade with copper conductor and in and drawing through PVC Conduits and connecting with Junction Box and Post top Lanterns/Street light fittings including continuous PVC insulated copper conductor single core earth continuity conductor of size 2.5 Sqmm complete all as directed. (Note : two runs of 2.5 sqmm cable, one run of 2.5 sqmm cable and one run of PVC conduit will be measured as one length)
Supply and laying in trenches/through pipes or bare in road crossings/paths/drains/ ducts/floors/along poles/walls/ ceilings/ equipments etc. Cable Under ground, Heavy duty, armoured, PVC insulated with stranded aluminium conductor, 1100 Volts grade of cross sectional area 35 Sqmm 3.5 Core including taking out old cable and remove from site.
Supply and laying in trenches/through pipes or bare in road crossings/paths/drains/ ducts/floors/along poles/walls/ ceilings/ equipments etc. Cable Under ground, Heavy duty, armoured, PVC insulated with stranded aluminium conductor, 1100 Volts grade of cross sectional area 16 Sqmm 4 core including taking out old cable and remove from site.
Supply and laying in trenches/through pipes or bare in road crossings/paths/drains/ ducts/floors/along poles/walls/ ceilings/ equipments etc. Cable Under ground, Heavy duty, armoured, PVC insulated with stranded aluminium conductor, 1100 Volts grade of cross sectional area 10 Sqmm 2 core including taking out old cable and remove from site.
Excavation in trenches in hard/dense soil not exceeding 1.5m wide and not exceeding 1.5 metre in depth for laying of cable and not exceeding 10 Sqm on plan for poles, struts, stays etc. and not exceeding 1.5 m in depth and getting out complete all as specified.
Returning, filling in, trenches including spreading leveling, watering and well ramming in layers not exc 25 cm.
Removing excavated material to a distance not exc 50 mtrs and depositing where directed at a level n.exc 1.5 mtr above the starting point.
M&L for cushioning for protection of cable using dry river or M sand, free from particles all as specified and directed.
M&L for Protection to cable with one layer of new bricks laid flat butting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable using old size sub-class ‘B’ bricks.
Supply and lay in trenches/under roads/crossings are fixed to wall/pole, GI tubing medium grade of size 50 mm bore including taking out old pipe and remove from site. Note : Excavation and earth work shall be paid for separately under relevant items of Schedule.
Supply and filling Transformer oil of dielectric strength not less than 40 KV, conforming to IS-335.
Supply and Fixing RCCB, double Pole, 100 mA, 32 A amps, 10 KA. Make : Havells/Schneider/Legrand
Supply only LED tube lamp 20 watts, 230 volts, retrofit type, T-8, 4 ft long, with inbuilt electronic driver and Poly carbonate cover, Complete all as specified and directed.
Supply only Tube lamp fitting 4 ft long, box type, with asthetic end caps, suitable for LED tube lamp T-8 type complete with all accessories, without lamp.
Supply only MCB, SPN, (6-32 Amps) as ordered, 10 KA.
Supply only MCB, SP, (6-32 Amps) as ordered, 10 KA.
Supply only MCB, TPN, (40-63 Amps) as ordered, 10 KA.
Supply only LED lamp bulb 12 watts, 230 volts, retrofit type, with B22 cap, (Cool Day Light/Warm White) as ordered Complete all as directed.
Supply only LED lamp bulb 9 watts, 230 volts, retrofit type, with B22 cap (Cool Day Light/Warm White) as ordered Complete all as directed.
Supply only LED lamp bulb 7 watts, 230 volts, retrofit type, with B22 cap (Cool Day Light/Warm White) as ordered Complete all as directed.
Supply only Wall mounted fan, 400 mm sweep, 230 Volt, with built in regulator complete with all accessories.
Supply only Switch flush type, 5 Amps, single pole, one way.
Supply only Switch Socket combination, 2 in 1, 3 pin 5 & 15 Amps (6 pin) flush type universal.
Supply only Switch Socket combination, 3/2 pin 5 Amps flush type.
Supply only Ceiling Rose Surface PVC type 65 x 50 mm two to three terminals.
Supply only Bell push, flush type, 5 Amps, single pole.
Supply only Bell, AC, Ding Dong type 230 Volt.
Supply only Regulator, Modular, Electronic Step type, 2 Module, 120 Watts, 230 Volt suitable for Ceiling fan
Supply only Modular type Switch single pole 6 Amps one way
Supply only Modular type Switch Bell Push Single pole 6 Amps one way
Supply only Modular type Switch single pole 16 Amps one way
Supply only Modular type socket out let 2 in 1, 6/16 Amps.
Supply only Modular type Socket out let 6 Amps.
Supply only Lamp holder PVC type with back plate suitable for batten fittings.
Supply only PVC insulated copper flexible wire, twin twisted, of size 23/0.0076.
Supply only PVC insulated, 1100 Volt grade, Single core, cable with multi stranded copper conductor of size 1.5 Sq mm
Supply only PVC insulated, 1100 Volt grade, Single core, cable with multi stranded copper conductor of size 2.5 Sq mm
Supply only PVC insulated, 1100 Volt grade, Single core, cable with multi stranded copper conductor of size 4 Sq mm
Supply only PVC insulated, 1100 Volt grade, Single core, cable with multi stranded copper conductor of size 6 Sq mm
Supply only PVC insulated and PVC Sheathed, 1100 Volt grade, three core, cable with multi stranded copper conductor of size 6 Sq mm
Supply only Flat, 3 Core PVC Insulated, Sheathed Submersible cable with multi stranded copper conductor of size 4 Sq mm,1100 V grade.
Supply only PVC Insulation tape Roll, Self-Adhesive, Electrical Insulation Tape of length 30 mtrs and 30 mm wide. Make : Steel Grip
Supply only Electronic driver suitable for LED lamps of capacity 150 to 350 Watts of any make.
Supply only Electronic driver suitable for LED lamps of capacity 70 to 90 Watts of any make.
Supply only Electronic driver suitable for LED lamps of capacity 36/46 Watts of any make.
Supply only Plug top 15 Amps, 3 Pin, PVC body
Supply only Plug top 5 Amps, 3 Pin, PVC body
Supply only Capacitor 2.5 Mfd suitable for Fans
Supply only Capacitor 4 Mfd suitable for Fans
Supply only Modular white cover plate 2 Module with frame
Supply only Modular white cover plate 3 Module with frame
Supply only Modular white cover plate 4 Module with frame
Supply only Modular Metal flush box 2 Module
Supply only Modular Metal flush box 3 Module
Supply only Modular Metal flush box 4 Module
Supply only Supply only Electronic Regulator, Flush, Step type, 120 Watts, 230 Volt suitable for Ceiling fan
Supply only Rigid non-metallic PVC conduit of size 20 mm dia, exclusive of boxes (junction/terminal) but inclusive of all tees, bends,elbows reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.
Supply only PVC casing caping of size 20 mm dia, exclusive of boxes (junction/terminal) but inclusive of all tees, bends,elbows reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles etc.
Manning and Operation of CQA(W) Sub Station Cum Service center at CQA(W) Colony, GCF and VFJ by employing one Electrician (Skilled) Labours per Shift of 8 hrs for 3 Shifts, 24 Hrs per day, including Sundays & Holidays, comprising the following works :- (i) Monitoring/operatting including replacing blown out fuses, as and when required, of Two/Four pole structure with Air break switches and expulsion fuse units - 2 Nos. (ii) Monitoring/ operatting HT 11 KV OCB Panels, indoor/outdoor type- 02 Nos. (iii) Monitoring checking and watering Earthing system. (iv) Monitoring/operating as and when required LT Panel Boards with LT ACB and MCCBs & APFC Panel - 4 Nos (v) Monitoring/operatting Transformers - 3 Nos including checking oil level, silica gel in breather and leakage as directed (vi) Maintaining record of Electric Supply break downs/shut downs (vii) Attending day to day complaints of Internal/External Electric Supply including replacement of fittings/fixtures/Lamp fittings/Lamps etc. (viii) Any other works for smooth functioning of installation all as directed by the Engineer-In-Charge. The installation is comprising of the following : -
DETAILS OF ELECTRIC SUPPLY INSTALLATION :-
(a) Transformer - 3 Nos
(b) OCB - 2 Nos
(c) Two Pole Structure with GO Switches and DO fuses - 2 Nos
(d) LT Panel Boards - 04 Nos
MAN POWER TO BE EMPLOYED ARE AS UNDER :-
Electrician - 01 No per shift Total No. of Shift - 03
Manning and Operation of Troops Line Sub Station Cum Service center, NAI and LPR by employing one Electrician (Skilled) Labours per Shift of 8 hrs for 3 Shifts, 24 Hrs per day, including Sundays & Holidays, comprising the following works :- (i) Monitoring/operatting including replacing blown out fuses, as and when required, of Two/Four pole structure with Air break switches and expulsion fuse units - 8 Nos. (ii) Monitoring/ operatting HT 11 KV OCB Panels, indoor/outdoor type- 01 No. (iii) Monitoring checking and watering Earthing system. (iv) Monitoring/operating as and when required LT Panel Boards with LT ACB and MCCBs & APFC Panel - 8 Nos (v) Monitoring/operatting Transformers - 7 Nos including checking oil level, silica gel in breather and leakage as directed (vi) Maintaining record of Electric Supply break downs/shut downs (vii) Attending day to day complaints of Internal/External Electric Supply including replacement of fittings/fixtures/Lamp fittings/Lamps etc. (viii) Any other works for smooth functioning of installation all as directed by the Engineer-In-Charge. The installation is comprising of the following : -
DETAILS OF ELECTRIC SUPPLY INSTALLATION :-
(a) Transformer - 7 Nos
(b) OCB - 1 Nos
(c) Two Pole Structure with GO Switches and DO fuses - 8 Nos
(d) LT Panel Boards - 08 Nos
MAN POWER TO BE EMPLOYED ARE AS UNDER :-
Electrician - 01 No per shift Total No. of Shift - 03
Note for item No. 65 & 66 :-
The rate quoted shall be deemed to be included for the following provisions :-
(i) Operator must be skilled & must have knowledge of operation & maintenance of Electrical Sub Stns including VCBs, Transformers, Pump Sets, DG Sets, Panel, AC Plants etc.
(ii) Consumable stores such as cotton waste, Grease including tools required shall be provided by the contractor
(iii) Operator must ensure cleanliness of VCBs, Transformers, Pump Sets/DG Sets/Panels/AC Plants
(iv) The rate quoted by the contractor shall be inclusive of Life insurance for the tradesmen employed by him in case of untoward incident such as injuries, fracture or casualty while on duty
(v) Carrying out minor repairs viz. replacing blown out fuses, recharging MCCBs, priming of pumps, repair to pipe lines as directed.
(vi) Inform the JE/AGE E&M inchrge of any electric faults and any other mishappenings.
(vii) Attending day to day complaints as detailed by the JE/AGE
(viii) Any other work, not specifically mentioned above, but ordered by the Engr-in-Charge for the smooth functioning of Sub Station and Service Centre
(ix) Items/spares required to be replaced will be measured and paid as supply only under relevent items of this schedule.
M K ENTERPRISES
TRISHLA CONSTRUCTIONS
M/S CENTRAL REFRIGERATION AND ELECTRICALS
Goodluck Enterprises
M/S. HONEY CONSTRUCTIONS
RAVINDRA ELECTRICAL
RAINA SALES AND SERVICES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .