| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹62.3 LAccepted-AOC 387 M G ROAD KRISHNANAGAR NADIA PIN 741101 | NADIA | WEST BENGAL | 741101 | ₹62.3 L | L1 | Accepted-AOC L1 |
| 2 | L2₹62.3 LRejected-Finance | ₹62.3 L | L2 | Rejected-Finance L2 |
| 3 | L3₹62.4 LRejected-Finance | ₹62.4 L | L3 | Rejected-Finance L3 |
| 4 | L4₹62.5 LRejected-Finance 30 2 BOWBAZAR WEST LANE P O KRISHNAGAR DIST NADIA 741101 | KRISHNAGAR | NADIA | WEST BENGAL | 741101 | ₹62.5 L | L4 | Rejected-Finance L4 |
Tender Value
Refer Docs
EMD Value
₹1.3 L
Closing Date
9 Mar 2026, 4:30 pmClosed
Executive Engineer (A-M) Burdwan (A-M) Division
Kalna Road, Near Agril Farm, Purba Bardhaman- 713101
Conversion with Renovation of WTA of Charki Govt. O and O Major RLI Scheme at Mouza- Charki, Block-Ketugram-II under Katwa(A-M) Sub- Div in the District of Purba Bardhaman under the E E (A-M), Burdwan (A-M) Division under Core sector 2025-26
2026_WRDD_1012924_1
WBWRDD EEAM BDN eNIT-46 CS 2025-26
Open Tender
Miscellaneous Works
60 days
Charki RLI, Block-Ketugram-II
Please refer Tender documents.
4 documents required · 4 mandatory
₹1.3 L
13 Mar 2026
23 Feb 2026
11 Mar 2026
23 Feb 2026
9 Mar 2026
23 Feb 2026
Procurement of UPVC; M.S. / C.I. ; ERW / GI pipes etc Materials and other Fittings etc. ( Please see the details in Sheet Material Procurement)
Laying of Water Transmission Arrangment (WTA). ( Please see the details in Sheet WTA)
Internal Wiring . ( Please see the details in Sheet IW)
Cost of Energisation. (Please see the details in Sheet Energ)
BoQ_Ver3.0
Bidder Name :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
Procurement of UPVC: Supply and Transportation of UPVC Pipes (Class-I) IS:4985/2000 Certification marked with latest ammendments, Ivory Grey coloured, both end plain, along with one matching coupler/socket(Class-II)duly IS:10124/1988 matked & required Solvent cement duly IS:14182/1994 marked for each pipe. Length of each straight pipe 6.0 mts with tolerence (± )10 mm
315 mm dia P.V.C. Pipe(Cl-I) with Coupler (Class-I)
200 mm dia P.V.C. Pipe(Cl-I) with Coupler (Class-I)
140 mm dia P.V.C. Pipe(Cl-I) with Coupler (Class-I)
Supply and Transportation of UPVC Pipes (Class-II) IS:4985/2000 Certification marked with latest ammendments, Ivory Grey coloured, both end plain, along with one matching coupler/socket(Class-II) duly IS:10124/1988 matked & required Solvent cement duly IS:14182/1994 marked for each pipe. Length of each straight pipe 6.0 mts with tolerence (± )10 mm
140 mm dia P.V.C. Pipe(Cl-II) with Coupler (Class-II)
Supply of UPVC fittings conforming to IS 10124 (Part-1 to 10) / 1988 with latest ammendments.
200 mm dia P.V.C. Equal Tee (Class-II)
140 mm dia P.V.C. Equal Tee (Class-II)
315 mm dia F.T.P. (Class-II)
200 mm dia F.T.P. (Class-II)
160 mm dia F.T.P. (Class-II)
160 X 140 mm P.V.C. Reducer (Class-II)
200 X 140 mm P.V.C. Reducer (Class-II)
200 X 60º P.V.C. Bend (Class-II)
140 X 90º P.V.C. Bend (Class-II)
140 X 60º P.V.C. Bend (Class-II)
200 mm dia P.V.C. End Cap(Cl-III)
140 mm dia P.V.C. End Cap(Cl-III)
315 mm dia P.V.C.Extra Coupler (Class-II)
200 mm dia P.V.C.Extra Coupler (Class-II)
140 mm dia P.V.C.Extra Coupler (Class-II)
Supply and Transportationof Solvent Cement ( conforming to IS 14182/1994 with latest ammendments)
Supply and Transportation of 150 mm dia PVC flexiable suction hose pipe
M.S. ACCESSORIES: Supply and Transportation of G.I. Quadrupped Set and Inlet & Outlet Pipe Fittings for Major RLI Scheme (2 nos. chamber for 1 set)
Supply and Transportation of 150 mm dia C.I. Sluice Valve with hand wheel,ISI marked,IS:14846
Supply and Transportation of Nipple Type 150 mm dia NB Alfa Alfa valve "Type-C". (1no Handwheel for 04Nos of Valve) as per existing drawing
Supply and Transportation of 150 mm dia 90 degree GI Bend both end flanged ISI Marked -IS 1239, Galv-IS-4736
Supply and Transportation of 150 mm dia 90 degree GI Priming Bend both end flanged ISI Marked -IS 1239, Galv-IS-4736
Supply and Transportation of 150 mm dia Galv. MS Flanged Pipes IS marked 1239,Galv-IS 4736 (4.8mm thick wall)
Supply and Transportation of 150 mm dia C.I. Foot valve, flanged end & swing type as per IS 4038/1986(Table-17) with latest amendment.The disc face will be made of leather and strainer made of galvanized steel.The Valves shall be tested for (closed end test) against Hydrostatic test requirement.
Supply and Transportation of 150 mm dia MS Heavy Duty Hose Clamp fitted with bolts & nuts (2 sets) 2.5 mm thick, 45 mm width.
Supply & Transportation of 150 mm dia C.I. Combined Tail Piece both side groved.
Supply & Transportation of 150 mm dia C.I. Tail Piece with flange adopter one side grooved overall length(175+/-15) mm and other end flanged(12 mm flange thk) with 7 nos. grooves as Per IS:1538 and drilled as Per Table-17 of IS:6392.
Fabrication, supply, and transport of heavy-duty movable trolley of size 1525 mm × 760 mm, made with 50×100×50 mm M.S. U-Channel (IS 2062) including cross-bracing, continuous welding (IS 814), fixing of heavy-duty castor wheels (150–200 kg capacity), top platform, surface preparation, primer and enamel painting – all complete as per direction of EIC.
Supply and Transportation of M.S. Hexagonal Head Nuts and Bolts conforming to IS 1363(Part-I)/1992 of product grade C with latest amendmends for Bolts & IS 1363(Part-3)/1992 of product Grade-C with latest amendments for Nuts properties /Class for Bolt-4.6 & for Nut-4.5.ISI marked.
Supply and Transportation of Foundation Bolt for Distribution Chambers (Quadruped Sets) and manufactured from 20 mm nominal diameter MS Rod as per IS:2062/1992. Total length of the Bolt is 375 +10 mm having welded head 80 +10 mm in length and 20 mm in nominal diameter nut and 2 nos. washer, The average weight of such bolt to be 1.1 kg. per bolt with tolerance in weight of each bolt @ +10%.
Supply and Transportation of 500 mm dia (Table-5) Compressed Asbestos Fibre Jointing for Quadruped set(for raised surface of flange as per IS:6392).
Supply and Transportation of 150 mm dia Foot Valve Leather Washer best quality brand (Imperial/Techno/Burhani).
Supply and Transportation of Rubber Insertion 5 mm thick with proper reinforcement 2 ply conforming to IS 638/79 with standard drilled holes with latest amendmends suitable for raised surface of MS flange as per IS 6392/71 (Table 5, 11 & 17).
300 mm dia Rubber Insertion (Table No.11)
300 mm dia Rubber Insertion (Table No.5)
200 mm dia Rubber Insertion (Table No.11)
200 mm dia Rubber Insertion (Table No.5)
150 mm dia Rubber Insertion (Table No.17)
150 mm dia Rubber Insertion (Table No.5)
80 mm dia Rubber Insertion (Table No.17)
Electro Motor Pump Sets,ISI Marked, IS 12615 & IS-6595;Mono block as per IS 9079 (Read with latest ammendment for all IS) 200Cum/hr,18m head. (20HP)
20 HP 30 Electromagnetic Star-Delta motor controllers with 4 pole heavy duty Power contactor, single phasing preventer and normal protective features, MCB, Indicators, push buttons, Ammeter &Voltmeter, all in IP54 enclosure of min 16swg. C R sheet steel,10 tank process powder coat painted and as per technical specification.
200A Four Pole Busbar Chamber with copper bars of 12" x 1.5" x 0.25" provide with requisite bolts (with insulated cap), nuts, washers in CRCA sheet metal enclosure of thickness 17 SWG (1.22 mm) having dimension of 18" x 12" x 6 " with rating & W.R.D.D. letter embossed on cover, with contineous welded smoothly chamfered edges, dust and vermin proof, stove, enamelled/powder coat painted and with raised mounting arrangement. IS 60947.
200A Heavy duty rewireable Switch Fuse Units with fuse base and carrier, shall comply with and be tested by CPRI/ERDA/BIS lab tested as per latest IS: 10027-2000 and IS/IEC 60947-3
63A Heavy duty rewireable Switch Fuse Units with fuse base and carrier, shall comply with and be tested as per latest IS: 10027-2000 and IS/IEC 60947-3, marked with standard ISI certification mark
Fabricated MS Kisok Box of size 1800 x 1200 x 750 mm mounted on 4 members of legs made of MS Angle of size 65 x 65 x 6 mm. All sides are covered with 3 mm MS Sheet on the frame of MS Angle of size 40 x 40 x 6 mm with back side cover made of 3 mm thk. MS Sheet and MS flat of size 40 x 6 mm and providing MS channel Door made off 20 x 6 mm MS flat inside the Box for fitting the electrical equipment having locking arrangement with 1 no of MS hasp bolt of 16 mm dia x 300 mm long & 2 nos MS Door handle. The legs are detachable type fitted with MS bolts and nuts bifurcated with 16 mm dia drilled hole for mounting the same with nuts & bolts in the concrete base /piller and painting 2 coats with anticorrosive red lead painting complete.
Total =
Say Rs.
Forty Six Lakh Fourteen Thousand Three Hundred & Seventy Only
BoQ_Ver3.0
Bidder Name :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
Laying of Water Transmission Arrangment (WTA).
Earthwork in excavation of foundation trenches or drains in all sorts of soil (including mixed soil but excluding laterite and sand stone), including removing, spreading or stacking the spoils, within a lead of 75 m as directed.The item includes necessary trimming the sides of trenches, levelling,dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1500 mm. ( Page- 01,Item no. 2(a), PWD SCHEDULE-2017)
Earthwork in excavation of field trenches as per designed section & alignment for laying of pipe lines(PVC,RCC,ACP etc.) upto a depth of 1500 mm in all sorts of soil including removing, spreading or stacking extra earth as directed.The item includes necessary trimming the sides of trenches, levelling,dressing and ramming the bottom as required complete. { WRI&DD SOR 2018/ Chapter No. VI.SLno.2.10,page no-14,Item No-1)
Laying of P.v.C. pipes of different diameters within field trenches in curve /straight line using P.V.C. fittings, viz. Bend, Tee, Reducer etc. and making leak proof joints with couplers after roughening the surface with wire brush and emery paper and applying solvent cement (The rate is inclusive of transport of pipes, fittings and solvent cement to be supplied by Deptt.) all complete as per direction of Engineer-in-Charge.{ WRI&DD SOR 2018/ Chapter No. VI.SLno.2.20,page no-14,Item No-1(A)(ii)(iii)
a) 200 mm dia
b) 140 mm dia
c) 315 mm dia
Earth work in filling in trenches after laying pipe lines (PVC,RCC,ACP etc.) with good earth obtained from excavation of field trences in layer not exceeding 225 mm , including watering & ramming etc. layer by layer complete. (payment will be made on the basis of measurement of finished quantity of work) { WRI&DD SOR 2018/ Chapter No.VI.SLno.2.10,page no-14,Item no-2
Filling in foundation or plinth by Silver sand in layers not exceeding 150 mm as directed and consolidated the same by through saturation with water ramming complete including the cost of supply of sand.a) Fine Sand ( Page- 02,Item no. 4(B), PWD SCHEDULE-2017)
Single brick flat soling of picked Jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. ( Page- 1, Item no. 1, PWD SCHEDULE 3rd corri-2018 )
Ordinary Cement concrete (Mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement , if any, in ground floor as per relevant IS codes.(a) Pakur vareity (Page- 10, (Item no. 27, PWD SCHEDULE 3rd corri-2018)
Hire and labour charges for shuttering with centering and necessary staging upto 4 metre using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor). 25 mm. to 30 mm. thick wooden shuttering as per decision & direction of Engineer-In-Charge. (Page- 42, Item no. 12(a), PWD SCHEDULE-2017)
Brick work with Ist class brick in cement mortar (1 : 6).(a) In foundation and plinth(Page- 2, Item no. 4, PWD SCHEDULE 3rd corri-2018)
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor. ( Page- 3, Item no.8 , PWD SCHEDULE 3rd corri-2018)
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (i) With 1:6 cement mortar (c) 15 mm thick plaster. (Pg - 49, Sl no - 1 of PWD 3rd corri -2018)
Neat cement punning about 1.5 mm. thick in wall dado, floor, drain, door and window sill etc. Complete. (Pg - 192, Sl no - 15-PWD-2017)
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction. For works in foundation, basement and upto roof of ground floor / upto 4m. Tor steel/Mild steelI. SAIL/ TATA/RINL (i)For foundation Blocks of Water Distribution System [ Page no.43, item no. 40 (a)(i)( I )of PWD Schedule 2017 ]
Fitting and fixing of M.S. / G.I. / C.I.accessories and special in pipe line (accessories & special to be supplied departmentally) including supply of jointing materials viz.rubber insertion, nuts & bolts, havoc Zink (Zink Oxide) complete as per direction of Engineer-in-Charge. a) 150 mm dia sluice valve. (WRI&DD SOR 2018/ Chapter No. VI.SLno.2.20,page no-15,Item No-2(b)(xxviii)
Labour Charges for fitting, fixing and laying, where necessary of following M.S / G.I. / E.R.W. pipes and accessories (to be supplied departmentally) including transportation of the same cutting, threading, jointing and making leak-proof threaded / flanged joint at site, by using socket / rubber insertion, nuts and bolts etc. maintaining proper alignment and level - all complete - as per direction of Engineer-in-Charge. (i) 150 mm. dia. ERW pipe. (WRI&DD SOR 2018/ Chapter No. VI.SLno.2.20,page no-14,Item No-2(i)(a)
Erection, fitting, fixing of set of M S Quadruped inlet and outlet pipe fittings for 1st chamber and 2nd chamber of Major RLI Scheme. (Rate inclusive of transportation from departmental store to work site) (WRI&DD SOR 2018/ Chapter No. VI.SLno.2.20,page no-16, Item No-12
Labour charges for fitting, fixing 150 mm. Dia. Alfa-Alfa valve with 140 mm. dia.P.V.C. pipe with the help of flanged P.V.C. tail-piece by joining the P.V.C.End of Tail-piece and riser pipe with coupler and flanged end of Tail-piece and Alfa-Alfa valve with rubber insertion, nuts and bolts etc. complete. { WRI&DD SOR 2018/ Chapter No. VI.SLno.2.20,page no-15,Item No-3)
Supplying, fitting and fixing including transportation of sign board for identifing the exact location of Major RLI scheme (one at road side and other at site) the board will be made 3 mm thick MS plate of size 300 mm × 600 mm and fitted and fixed on 50 mm GI Pipe of IS 1239/90 (part-1) including cutting, welding and writting of both sides of Sign board. Base - Yellow, and ward Red. Both bottom end of the stands pipe will be grouted in 1:2:4 CC on a single brick flat soiling. This will include one materials and labour complete as per drawing and direction of EIC. { WRI&DD SOR 2018/ Chapter No. VI.SLno.2.20,page no-17,Item No-17)
M.S. structural works with hollow sections (square or rectangular shape)conforming to IS: 806-1957 & IS:1161-1958) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-inCharge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1956 & IS: 9595 using electrodes of approved make and brand conforming to IS:814-1957, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete. Payment to be made on the basis of calculated weight of structural memebrs of MS Holow Section as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a hight of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for each additional floor or 4m. beyond the initial 8 m. or part thereof. i) For roof truss works a) Span up to 12 Mtr.(Sec-1(E),pg-91, sl no - 9 of PWD.)
Galvanised corrugated iron sheet work (excluding the supporting frame work) fitted and fixed with 10 mm. dia J or L hook-bolts, limpet and bitumen washers and putty complete with 150 mm. end lap and one corrugation minimum side lap. (Payment to be made on area of finished work)(GCI sheet to be supplied by contractor) In wall (a) With 0.60mm Thick Sheet (Sec-1(E),pg-91, sl no - 9 of PWD.)
Testing of pipe line system against leakages by filling the distribution chamber with water and supplying water through the entirepipe line net work for at least 4 (four) hour by running the departmental Diesel Engine pumping set, including supplying necessary fuels & lubricants and hiring and transporting tools and plants all complete as per direction of Engineer-in- Charge. for Major (Ch.6.2, para -2.3 , sl -7 .page- 16 of WRDD)
For Water transmission Arrangement of RLI I 4% extra over the schedule rates, save & except for earth work in excavation & filling works, will be allowed for extra carriage by cart I boat I head load besides initial transport by truck etc.for Item no-1 to 21 excluding item No-1,2,4,18 & 21 {WRI&DD SOR 2018/Introduction Point no-8)
Sub-Total
Add GST @18%
Cost of civil works excluding Labour welfare cess
Add Labour welfare cess @ 1%
Grand Total
Ten Lakh Thirty One Thousand Five Hundred & Sixty Four Only
BoQ_Ver3.0
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
Internal Wiring (IW).
Supplying, fitting & fixing 350 mm x 250 mm x 25 mm size Wooden Plank on wall I(for fitting & fixing of electrial equipments as necessary on the plank).(WRDD schedule Page-42, Item no-9,Sl no-8)
Fitting and fixing of 200 Amp. 415 volt iron clad / sheet steel / TP/TPN main switch on iron legs on wall . [Ref.- PWD SOR 2017 Ele.Sh. Item no.- 1 Page-C-1 ]
Fixing only MS sheet metal busbar Chamber on angle iron frame on wall [Busbar supplied departmentally] 4 bars 63 Amps [Ref.- PWD SOR 2017 Ele.Sh. Item no.-6, Page-C-1 ]
Supplying and Drawing with 1.1 KV, PVC flexible 'FR' cables copper conductor conforming to IS 694 in suitable size with fitting and fixing on wall/Kiosk Box, including making necessary connection to the pre-fixed devices with all necessary accessories like saddle, screw, clips, gland, socket etc. conforming to lEE regulation and as per direction of EIC. (Brand: Gloster/Havells/Finolex) 4Cx 25 sqmm Copper cable conforming to IS 694 in [100/200 A TPN switch to BUSBAR.[Ref:-WRIDD SOR 2018 item no -14 page no -112]
Fitting and fixing 63Amp. 415 volt iron clad / sheet steel / TP/TPN main switch on iron legs on wall. [Ref.- PWD SOR 2017 Ele.Sh. Item no.-1, Page-C-1 ]
Supplying and Drawing with 1.1 KV, PVC flexible 'FR' cables copper conductor conforming to IS 694 in suitable size with fitting and fixing on wall/Kiosk Box, including making necessary connection to the pre-fixed devices with all necessary accessories like saddle, screw, clips, gland, socket etc. conforming to lEE regulation and as per direction of EIC. (Brand: Gloster/Havells/Finolex) 3C X 16 sqmm copper cable conforming to IS 694. [Ref:-WRIDD SOR 2018 item no -14(ii) page no -112]
Fitting & fixing of Starter (Direct on Line or Star Delta/Auto- Transformer) with Nuts & Bolts fixed on Angle iron frame on wall and making necessary connection with the electrical cables.Star-Delta 1Auto-Transformer Starter (Above 15 HP upto 25 HP) [Ref.- WRIDD SOR 2018 Item no.-12, Page-42 ]
Supplying and Drawing with 1.1 KV, PVC flexible 'FR' cables copper conductor conforming to IS 694 in suitable size with fitting and fixing on wall/Kiosk Box, including making necessary connection to the pre-fixed devices with all necessary accessories like saddle, screw, clips, gland, socket etc. conforming to lEE regulation and as per direction of EIC. (Brand: Gloster/Havells/Finolex) 2 X 3C X 10 sqmm copper cable conforming to IS 694 in 32 mm GI conduit (lSI-Medium quality) If Star-Delta Motor starter to Motor][Ref:-WRIDD SOR 2018 item no -14(iii) page no -112]
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. PVC clips, fittings etc. to light/fan/call bell point with piano key type switch (Anchor make) fixed on sheet steel fabricated switch board with Perspex/bakelite top cover on wall incl. necy. connections and making earthing attachment and mending good damages to building works [PVC casing-capping and Switch board both on surface] Average run 6 meter.[Ref.- PWD SOR 2017 Ele.Sh. Item no.-D-2(b), Page-E-11 ]
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts.long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By TATA-Medium GI pipe [Ref.- PWD SOR 2017 Ele.Sh. Item no.-2, Page-G-1 ]
Supplying & fitting earth Busbar of galvanished Plate 25 mm X 6 mm having clearance of 6 mm. From wall including providing driled holes about 3cm.Apart complete with G.I Bolts washers etc. [Ref.- PWD SOR 2017 Ele.Sh. Item no.-4A, Page-G-2 ]
Connection the equipments to earth Busbar including S & F 8 SWG G.I wire of size as below on walls/floor with atiples buried inside floor/ walls required and making connection to equipments with bolts and nuts and washer, cable ling etc. Mending good damges [Ref.- PWD SOR 2017 Ele.Sh. Item no.-5A, Page-G-2 ]
Supplying &Wiring for Plug point 15 Amp. 250 volt switches with socket indicator and fuse (3 in one system) Anchoe make iincluding supplying wooden board screw 16 SWG G.I wire for necessary earthing arrangement as per direction of the Engineer-In-Charge. [Ref.- PWD SOR 2017 Ele.Sh. Item no.-5, Page-E-22 ]
Supply, fitting and fixing EI danger board size 20cm.X 30cm. As per I.E Rule [Ref.- PWD SOR 2017 Ele.Sh. Item no.-20(b), Page-41 ]
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection.Havells. 16A (PWD elec. Sh. 2017 Page-D-6, item-07 )
Supplying and fixing MCB Enclosure 2-way (PWD elec. Sh. 2017 Page-K-1 Annexure-I , Sl.No.-07 ) [for MCB Isolator]
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection.Legrand.DP. 32A (PWD elec. Sh. 2017 Page-D-5, item-06 )
Wiring from Busbar to MCB Enclosure by the following size of 1.1KV grade single core stranded 'FR' PVC insulated and unsheathed copper wire (Brand Approved by EIC) in 25 mm PVC casing-capping (Precision make) including necessary PVC clips fittings etc. as required. (PWD elec. Sh. 2017 Page-E-11, item-1b )
2X 22/0.3 (1.5 Sq mm) + 1 X 22/0.3(1.5 Sq mm) ECC
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling. (PWD elec. 2017 Sh. Page-D-13, item-22)
Supplying & Fixing bulk head light fitting (Havells make) with die cast aluminium housing & frosted glass on wall/ceiling incl. S&F 8watt CFL / 100 watts GLS lamp complete set. (PWD elec. 2017 Sh. Page-D-13, item-23)
Placing and positioning the Centrifugal pump motor set on the pump base / pump house floor, aligning properly with necessary packing and fixing the set with holding down nuts and washer including cutting holes of requisite size in the floor / base, grouting the bolts and mending good all damages complete as per direction of the Engineer-in-Charge.20 HP Capacity [Ref:-WRIDD SOR 2018 item no -14(ii) page no -112]
Sub-Total
Cost of internal electrical wiring works excluding Labour welfare cess:
Labour welfare cess @ 1%:
Sub-Total
Cost of civil works including Labour welfare cess
Total =
Say Rs.
Seventy Six Thousand Four Hundred & Ninety Two Only
BoQ_Ver3.0
Bidder Name :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
Materials.
PCC Pole 9Mt Long
MS Channel 100×50mm (9.2 Kg /Mtr)
MS Channel 75×40mm (6.8 Kg /Mtr)
MS Angle 65×65×6mm (5.8 Kg /Mtr)
MS Flate 65×6mm (3.1 Kg /Mtr)
MS Flate 50×6mm (2.4 Kg /Mtr)
11KV "V" Bracket for 9mtr PCC Pole
11KV Top adaptor for PCC Pole 9mtr Long
11KV Pin insulator (polymer)
11KV Disc insulator (45KN) (polymer)
Hardware fitting for 11KV Disc ins
HT Stay Set Complete
HT Guy Insulator
Earth Spike
Turn Buckle
GI Wire 6 SWG (0.148 Kg/Mtr)
Stay Wire 7/10SWG
Lighting Arrester (12KV)
11KV TP G.O Isolator 200 Amp
A C S R 50Sqmm
DTR 63VA 11/0.433KV
11KVA CABLE 3C×70+1C×16+1C×50 SQMM
LT DISTRIBUTION KIOSK FOR 63KVA DTR
CAUTION BOARD 11KV
Labour
Erection of single 9 Mtr. PCC Pole with all fittings without insulator (HT) & painting
Erection of Sub stn D.P with all fittings on 9 Mtr. PCC Pole including fixing of Isolator, Fuse unit, Transformer, kiosk & top channel, painting but without any insulator.
Erection of H.T Stay set complete
Earthing complete
Fixing of 11 KV Disc Insulator
Fixing of 11 KV Pin Insulator
Fixing of LT Kiosk & main switch with complete connection 1 Ckt.
Fixing of T.P.G.O Isolator
Fixing of "T" Bracket on D.P with painting
Stringing sagging 3 Cond. With A.C.S.R 50 Sq. mm
Erection of 63 KVA Transformer
Fixing of lightening arrestor (1 set of 3 L.A)
Survey of H.T O.H line (P&F)
GPS survey of L.T & H.T.O.H Line
3ph service connection
ERECTION OF NEUTRAL EARTHING (TURN KEY)
QUOTATION CHARGES (SUPERVISION CHARGE + SECURITY DEPOSIT)
CESS @1% (SUPERVISION CHARGE + LABOUR + MATERIAL COST)
GST @ 18% (SUPERVISION CHARGE + LABOUR + MATERIAL COST)
Grand Total
Five Lakh Eleven Thousand Six Hundred & Sixty One Only
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.16 MB
Tendernotice_2.pdf
PDF • 1.87 MB
Tendernotice_3.pdf
PDF • 1.38 MB
BOQ_2488189.xls
BOQ • 0.44 MB
Download all tender documents and submit your bid