| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.1 LAccepted-Finance | L1 | Accepted-Finance Rate quoted is lowest | |
| 2 | L2₹3.9 L+₹81,987.40 (26.4%)Accepted-Finance | L2 | Accepted-Finance Rate quoted is second lowest | |
| 3 | L3₹4.2 L+₹1.1 L (35.7%)Accepted-Finance | L3 | Accepted-Finance Rate quoted is highest |
Tender Value
₹5.5 L
EMD Value
₹6,000
Closing Date
11 May 2021, 4:00 pmClosed
Superintending Engineer
SE ETC Sultanpur 400KV S/S Campus Payagipur Sultanpur
ANNUAL MAITENANCE OF 220KV TRANSMISSION LINES UNDER ETD, SULTANPUR.
2021_UPTCL_578431_1
T. NO. 148/ETCS/2020-21
Open Tender
Electrical Works
Item Wise
365 days
Sultanpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹708
SE ETC Sultanpur
₹6,000
12 May 2021
31 Mar 2021
12 May 2021
31 Mar 2021
11 May 2021
31 Mar 2021
31 Mar 2021 - 11 May 2021
Amount
Following work are to be Carried out on 220KV Transmission Lines under ETD-Sultanpur with all Cost of Men Misc. Consumable T&P etc. Required for Satisfactory Completion of the work as per Technical Specifications & Direction of the Supervising Engineer.
Quarterly Routine Tower to Tower Patrolling from one end to other end of following Transmission lines and Submission of Patrolling report in Triplicate in Prescribed Proforma Mentioning the Stolen /Missing Tower part & Tower Accossries Tree falling in Range of Line Corridor Damage to Earth Wire Conductor Jumper Insulator & other Line Accessories damage to Foundation ,copping, Chimney ,Earthing etc.The Patrolling shall be done every Quarter ,with all due Care of Safty & Precautions.
220KV Sultanpur -Tanda Thermal Line, Line Length 69.87Km (Total Length 69.87x4=279.48Km)
220KV Sultanpur -New Tanda Line, Line Length 67.56 Km(Total Length 64.34x4= 257.36 Km)
Lilo of 220KV Sultanpur-Sangipur @ 220KV S/S Amethi Line Length 3.4 Km (Total Length 3.4x4=13.6 Km)
Emergency Patrolling of the above Transmission Lines the event of Tripping/Break Down of the Line (to Commence with 2 hrs of Intimation for the same if Tripping/Breakdown in Day Time and by 07:300 AM if Tripping /Breakdown in Night Hours) as per Instruction of Supervising Engineer as per Details given below
Emergency Patrolling of the above Transmission line up to 20Km Distance ( one job each Emergency Patrolling)
Emergency Patrolling of the above Transmission line 20Km to 50Km Distance ( one job each Emergency Patrolling)
Periodic Cutting of different type of Trees like Mango Neem, Sheeshem, Peepal, Semal, Eucalyptus, Popular etc. having Girth 0.5 Meter to 1.0 Meter and falling in the Range of Corridore of above transmission line to provide minimum clerance of about 8 Meter between tree and Conductor on boath side if Tower/Line with all due Care of Safty & Precaution to Avoid any Damage of Building Power & Telephone Line Passing Nearby ,Crops, other Nearby Tree etc.The work Includes Eliminating & Cleaning the Lines Site after Cutting of Tree (30No Tree x4 Times in ayear =120 No Trees)
Periodic Lopping/Chopping of different type of trees like Mango,Neem Semal,Eucalyptus,Popular etc. having Girth 0.5 Meter to 1.0 Meter and falling in the Range of Corridore of above transmission line to provide minimum clerance of about 8 Meter between tree and Conductor on both side if Tower/Line with all due Care of Safty & Precaution to Avoid any Damage of Building Power & Telephone Line Passing Nearby ,Crops, other Nearby Tree etc.The work Includes Eliminating & Cleaning the Lines Site after Cutting of Tree ( 250No Tree x4 Times in ayear =1000 No Trees)
Periodic Hot spot Scanning of Section towers, mid, Span joint ,repair seleves & Jumper of followling transmission lines
220KV Sultanpur -Tanda Thermal Line, Line Length 69.87Km
220KV Sultanpur -New Tanda Line, Line Length 67.56 Km (Total Length 64.34x4= 257.36 Km)
Lilo of 220KV Sultanpur-Sangipur @ 220KV S/S Amethi Line Length 3.4 Km (Total Length 3.4x4=13.6 Km)
Replacement of missing tower part along with fabrication work and fixing after shifting of tower part ,nut & bolts from UPPTCL store to work site of above mention lines.
Checking & Tightening of Jumpers of tension towers including replacement of damaged jumpers fasteners if needed and including carriage of material from store to site of work of 220KV Transmission lines under ETD-Sultanpur.
Re-Fixing & Tightening of Dislocated /Shifted Conductor Vibration Dampers to its Place Including Replacement of Fasteners,if Required to be Provided by Department as Per Requirment of 132KV Transmission Lines.
Attending of breakdown due to failure of disc insulator and replacement of tension & suspension string/polymer along with mobilization of skilled gang including carriage of material from store to site & site to store after completion of work.
Tension string (160KN disc insulator)
Suspension /polymer string (70KN disc insulator/polymer)
Jumper replacement
NIRBHAY TRADERS
m/s Ramesh Kumar Singh
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .