EXECUTIVE ENGINEER
Room 602 bsnl bhavan Adarsh nagar hyderabad
Shifting installation testing and commissioning of 160kVA DG set from Madhapur TE to Gowliguda TE, SH Attending DG repair works, wiring and miscellaneous works.
2023_BSNL_175305_1
50/BEDH-II/2023-24
Open Tender
Electrical Works
Item Rate
180 days
HYDERABAD
Please refer Tender documents.
15 documents required · 15 mandatory
₹590
AO CASH MAIN BSNL HYDERABAD
₹5,263
6 Dec 2023
22 Nov 2023
1 Dec 2023
22 Nov 2023
30 Nov 2023
22 Nov 2023
Amount
Wiring for light/ power plug with 2x4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4x4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (a) 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire
(b) 2 x 4 sq. mm + 1 x 4 sq. mm earth wire
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator) (a) 4 way (4 + 12), Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 5A to 32 A Single pole MCB
(b) 63A Triple pole Isolator
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (a) 5/6 amps switch
(b) 15/16 amp switch
(c) 3 pin 5/6 amp socket outlet
(d) 6 pin 15/16 amp socket outlet
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. (a) 4 Module (125mm x 75mm)
(b) 6 Module (200mm x 75mm)
(c) 8 Module (125mm x 125mm)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. (a) 4 Module
(b) 6 Module
(c) 8 Module
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing of following accessories suitable for operation on 230volts, 50Hz AC supply including removing the faulty fittings etc as requirted. (a) 18/20 watts 4' LED type fittings (Make: CG / SS)
(b) 18" exhaust fan. (Make: CG / SS)
Attending emergecy break down works for EA sets upto 63 kVA by deputing skilled technician to identify the fault and inform the same to the concerned Engineer in - Charge, rectifying the fault and bringing the DG in working condition in case of minor faults.
Attending emergecy break down works for EA sets above 63 kVA EA sets by deputing skilled technician to identify the fault and inform the same to the concerned Engineer in - Charge, rectifying the fault and bringing the DG in working condition in case of minor faults.
Repair of 12 V Self startor of 63 kVA EA Set by removing from EA set by disconnecting the Battery cable c onnections, taking it work shop for repair and service by repacing the follwing faulty components and bringing back to site fixing it to EA set, connection of battery leads, testing the same etc. as required. (a) Bentex
(b) Bush cutting
(c) carbon brushes
(d) Clutchplate assembly
(e) Solenoid Switch ( Coil )
(f) service charges for repair
Repair of 24 V DC burnt out Starting Motor of above 63 kVA Engine Alternator set by rdisconnecting the Battery cable connections, taking it to work shop for repair and Service by replacing the folloing faulty components testing at work shop and bring back to site, fixing to Engine, reconnction of battery leads, testing etc. as required (a) Pinion Gear teeth filling
(b) Bush cutting and grinding
(c) carbon brushes
(d) Clutchplate assembly
(e) Solenoid coil
(f) Body coils rewinding
(g) service charges for repair
Attending idle Engine of 6R Kirloskar at Fire Station BSNL Bhavan Adarshnagar by complete cleaning of EA set, removing and cleaning of chowked fuel pipe lines, filling of water in the existing radiator, connection of battery cables, releasing of Air lock, cleaning of Nozzle pressure pipes, arranging external Diesel by bypassing the existing diesel tank for starting the EA set and testing etc. for checking the water pump fuction and pressure etc. as required during the Inspection of concerned officers etc. as required
Supply and fixing of 12V SMPS Battery charger for charging of existing battery including interconnections etc. as required.
Complete cleaning of Diesel tank with necessary cleaning agents, checking of leakages if any before installing the same and connecting the fuel flexible pipes to the existing EA set for both suction and return including disconnection of existing fuel pipe lines etc. as required.
Providing and fixing of new high pressure hydraulic pressure pipes externally by disconnecting the underground MS fuel line for suction and return to EA set including hydraulic crimping of banzos at both ends for both pipes etc as required.
Providing and fixing of MS cover plate of size 11"x11" for filling of diesel from the top including fixing arrangement etc. as required.
General servicing of the existing 30kVA oil cooled AVR including cleaning, replacing the components testing the same and other connected works.
Supplying and fixing of following electronic and electric components related to AVR including removing of burned components, testing etc, as required. (a) New Control board and PCB
(b) Sensing Transformers
(c) RYB Indicator bulbs
(d) Potentiometer & related control wiring
(e) Carbon brush
(f) Repairing of PCB control board including replacement of minor spares, inlcuding refixing and testing etc., as required.
(g) 40A 3Pole power contactor (Make: L & T)
(h) S/F control Relay
SRI SRINIVASA ELECTRICALS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .