| 1 | L1₹26.9 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹28.9 L+₹83,300 (2.96%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹29.5 L+₹1.4 L (5.04%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹32.4 L+₹4.2 L (15.1%)Rejected-Finance P O CHAMURCHI BAZAR CHAMURCHI DIST JALPAIGURI | CHAMURCHI | JALPAIGURI | WEST BENGAL | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹33.4 L+₹5.3 L (18.9%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
30 Dec 2019, 6:00 pmClosed
CWE BINNAGURI
HQ CWE BINNAGURI
REPAIR REPLACEMENT OF STREET LIGHT GARDEN LIGHT PERAMETER LIGHT GEYSER SOLAR WATER HEATER OTHER CENTRAL AMENITIES SUB MAIN DB AND INTERNAL ELECTRIFICATION UNDER GE SEVOKE ROAD
2019_MES_303443_1
8010/BIN/(SEV)/43/2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
SEVOKE ROAD MIL STN
AS PER TENDER DOCUMENT
8 documents required · 8 mandatory
₹500
GE SEVOKE ROAD
₹80,000
Yes
7 Feb 2020
4 Dec 2019
31 Dec 2019
4 Dec 2019
30 Dec 2019
18 Dec 2019
Amount
Schedule 'A'
Taking down street light fittings/bulk head fitting and refixing after repair/replacement of unserviceable spare part with the new one including retightening of loose connections with all accessories of any type and size from existing position/location and removing materials to store for keeping in safe custody or taking credit all as specified and as directed. (Note:unserviceable spare part required to be replaced with the new one will be measured and paid seperately under relevant items)
S & F including taking down existing, new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium roadway luminaire Greenline V2 with high power LED as light source lamp type 72W with SPD, IP 66 on pole(9/11mtr)/ wall/ tower, complete all as specified and as directed.
Supply only silicon filled moulded type weather proof LED driver suitable for 60/72W LED street light fittings, driver operating voltage should be 140V-270V, 50 Hz, PF>0.9
Supply only silicon filled moulded type weather proof LED driver suitable for 36-70 W LED street light fittings, driver operating voltage should be 140V-270V, 50 Hz, PF>0.9
Supply only silicon filled moulded type weather proof LED driver suitable for Highbay DuraLED flood light fittings, driver operating voltage should be 140V-270V, 50 Hz, PF>0.9
Supply only electronic ballast including taking down existing u/s for T5 fittings THD<33% and 2x24W capacity of make Havells cat part no: LHBT01224034 or equivalent makes all as directed and specified.
Supply only T5 high efficiency/high output FTL lamp of 24W capacity for T5 fittings all as directed and specified.
S&F in repair LED garden spike light 7W 360 lm, with dust jet water protection including taking down old u/s and making necessery connections all as specified and directed.
Taking down LED Garden Light 9 watt and refixing after repair/replacement the diffective part i.e holder/diode / LED lamp with new one including all accessories and repair/replacement of u/s Wire any size connected to garden lightwith new one and removing unserviceable material to store for keeping in safe custody or taking credit and refixing complete all as specifed and directed . (Note:unserviceable spare part required to be replaced with the new one will be measured and paid seperately under relevant items)
Supply only holder
Supply only diode
Supply only LED lamp
Supply only water proof, 3core PVC insulated and PVC sheathed, copper conductor cable of size 1.5 sqmm, 1100 Volts grade for electrical connection of street light fittings, complete all as specified and directed.
Supply and fixing thermoplastic cable junstion box having protection IP 66/67 "weather proof" for outside installation with knockout entry for cable of size 10 - 16 sqmm and 155x210x92mm with terminals and provision of one 16A MCB SP all as specified and as directed.
Excavation in trenches not exc 1.5 Mtr wide and not exc 1.5 Mtr deep soft/loose type of soil getting out and levelling of bottom surface to required level for cable/stay all as directed.
Removing excavated soil to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point all as specified and as directed.
Returning,filling in,including spreading,levelling,watering and well ramming in layers not exceeding 25 cm thick all in soft/loose soil as specified and as directed.
Supply & laying in trenches clear sand for cushioning under cable 8 cm below and 15 cm above complete in level all as specified and directed by Engr-in-Charge.
Supply and lay in trenches/wall LT UG XLPE insulated ,armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 10sq mm 2 core including taking down old u/s making necessery connections all as specified and as directed. (NOTE: Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this schedule 'A'). NOTE : Specification of cable shall be as under:- (a) Inner sheathing shall be of extruded PVC. (b) Cable shall also be supplied with sequences hall marking at every metre on the luner sheathing. (c) Ultra violet radiation resistance compounded comprising to ASRM-2863 flame netarded as per EIV specification. (d) Anti rodent and antitermite compound added. (e) PVC compounds of various grades as IS-5831. (f) Compaction conductors shall be shaped and arrangment to the same will be on the cable.
All as per item No 19.00 here in above but 16sq mm 4 core
All as per item No 19.00 here in above but 6sq mm 2 core
Supply and laying burnt clay sub class B brick as cable protection including taking down old u/s all as specified and directed.
Supply and fix GI pipe 40mm medium grade ISI marked for cable protection complete all as specified and as directed.
Taking down ceiling fan, exhaust fan and wall hanging fan from any location and any height, removing fan blades and caried to workshop for repair/rewinding and refixing the same after repair all as directed by Engineer-in-Charge. (Note- Cost of repair/Rewinding will be measure and separatly under relevant items).
M&L for rewinding of wall mounted fan of size upto 600mm sweep with super enamelled copper winding wire of 35 gauge of approved quality duly varnishing including replacement of minor part and reassembling, testing complete all as directed. (Make:-Finolex/Atlas/Devidyal or equivalent as approved by GE)
All as per item No 25.00 here in above but ceiling fan of size 1200/1400mm sweep
All as per item No 25.00 here in above but exhaust fan of size upto 300mm sweep
All as per item No 25.00 here in above but exhaust fan of size above 300mm upto 450mm sweep ---ditto--
Supply only ball bearing No 6201 for ceiling fan including taking out old & UNSV complete all as directed. Make- SKF/NBC/Tata.
Supply only ball bearing No 6304 for exhaust fan/wall fan including taking out old worn out complete all as directed Make- SKF/NBC/Tata.
Supply only capacitor 2.5 mfd complete all as directed Make- EPCOS/ASIAN/CG.
Supply only capacitor 4 mfd complete all as directed Make- EPCOS/ASIAN/CG.
Supply only canopy (Top & bottom) as per sample for ceiling fan including dismantling complete all as directed.
Supply only PVC insulated, PVC sheathed 3 core copper flexible cable round of size 23/.0076 Make-Plaza/Rallison/Seiko.
Supply only Fan down rod made out of GI pipe (LG) 15mm bore and 1.20 mtr long including rubber real and suitable nuts and bolts,safty pin complete all as specified and directed.
Taking down geyser of any capacity horizontal or vertical for repair/over hauling/replacement of unserviceable parts with new one and disconnection of electric/ water supply lines and refixing the geyser in serviceable condition after assembling & reconnecting the electric & water supply line including testing complete as specified and directed. (Note-Unserviceable spare parts required to be replaced with new oneshall be measured and paid separately under relevant item)
Supply only heating element of geyser 1.5 KW any shape "ISI marked" . Make : Bajaj/Recold or equivalent make as approved by the GE.
Supply only heating element of geyser 2 KW any shape "ISI marked" . Make : Bajaj/Recold or equivalent make as approved by the GE.
Supply only thermostat for geyser 300mm long ISI marked . Make - Bajaj/Recold or equivalent make as approved by the GE.
Supply only indicating lamp (Red/Green) any shape for geyser . Make : Bajaj/Recold or equivalent make as approved by the GE.
M&L for repairing of leakage of inner tank of geyser by brazing including required denting etc. for any type and make & capacity of Geyser complete as specified and directed.
Supply only PVC flexible heat resistant connection pipe 660mm long heavy duty with two brass coupling nut suitable for 15mm bore GI pipe including dismantling old unserviceable complete as specified and directed.
M&L for preparing the surface of geyser by cleaning all dust etc of capacity 25 Litre and painting complete in external surface only with one coat of synthetic enamelled paint by spraying machine including filling cavities with filler after cleaning all dust etc including writing the MES No complete as specified and directed.
All as per item No 43.00 here-in-before but 35 litre capacity.
All as per item No 43.00 here-in-before but 50 litre capacity.
Supply only glass wool in any type of geyser complete as specified and directed.
Supply only fusible plug for any make of geyser complete as specified and directed.
Labour only for maintenance and servicing of Solar water heater capacity 200 liters with cleaning of tanks and replacement of unserviceable spare parts as per existing make and model with new one including taking down and removing unserviceable material to store for keeping in safe custody or taking credit and refixing complete all as specifed and directed . (Note:unserviceable spare part required to be replaced with the new one will be measured and paid seperately under relevant items)
M&L for maintenance and servicing of Solar water heater capacity 300 liters with cleaning of tanks and replacement of unserviceable spare parts as per existing make and model with new one including taking down and removing unserviceable material to store for keeping in safe custody or taking credit and refixing complete all as specifed and directed . (Note:unserviceable spare part required to be replaced with the new one will be measured and paid seperately under relevant items)
Supply only 3KW KWIKOT Geyser Hard water element .
S & F in repair fountain light LED 15Watt coloured waterproof with all accessories including taking down unserviceable complete all as specified and as directed.
Labour only for maintenance and servicing of water purifier of capacity 10 liters/hrs with cleaning of tanks and replacement of unserviceable spare parts as per existing make and model with new one including taking down and removing unserviceable material to store for keeping in safe custody or taking credit and refixing complete all as specifed and directed . (Note:unserviceable spare part required to be replaced with the new one will be measured and paid seperately under relevant items) Make - AQUAGUARD.
Supply only activated Carbon in 200 gm packet.
Supply only Sediment Filter for Aqua guard.
Supply only UV tube 230 volts for Aqua guard.
Supply only solenoid valve for Aqua guard.
Supply only PCB complete for Aqua guard.
Labour only for maintenance and servicing of water purifier of capacity 10 liters/hrs with cleaning of tanks and replacement of unserviceable spare parts as per existing model and as per existing make and model with new one including taking down and removing unserviceable material to store for keeping in safe custody or taking credit and refixing complete all as specifed and directed . (Note:unserviceable spare part required to be replaced with the new one will be measured and paid seperately under relevant items) Make - KENT RO
Supply only activated Carbon filter big size one for KENT RO.
Supply only Sediment Filter size one for KENT RO.
Supply only UV tube 230 volts for KENT RO.
Supply only solenoid valve for KENT RO.
Taking down carefully old unsv copper /aluminium point wiring (light, fan, socket or power) complete including fittings and fixtures, removing materials to store for keeping in safe custody or for taking credit all as directed making good disturbed surfaces of walls with putty, cement and matching the colour of the surface as per existing.
M&L for concealed point wiring with two single core PVC insulated, unsheathed, multistranded copper conductor of size 1.5 sqmm and one single core PVC insulated unsheathed stranded copper conductor of size 1.50 sqmm green in colour as earth lead in and including PVC rigid conduit (medium grade) with all fittings & accessories including provn of MS sunk terminal box of appropriate size suitable for flush to wall for mounting switch, sockets, fan regulators etc with 3mm thick hylum sheet top cover with screws & cup washers for one light / fan point / call bell complete. NOTE : Cost of making good the disturbed surfaces (if any) matching with the existing surface is deemed to be included in the unit quoted rates.
All as per item No 64.00 here in before but for 5 pin, 5/6 A socket point on the independent board complete.
All as per item No 64.00 here in before but for 5 pin, 5/6 A socket point on the as the same board complete.
All as per item No 64.00 here in before but with two single core PVC insulated, unsheathed, multistranded copper conductor of size 4 sqmm and one single core PVC insulated unsheathed stranded copper conductor of size 4 sqmm green in colour as earth lead for 15/16 A switch-socket point on independent board complete.
M&L for wiring in existing conduit with two single core PVC insulated, unsheathed, multistranded copper conductor of size 1.5 sqmm and one single core PVC insulated unsheathed stranded copper conductor of size 1.50 sqmm green in colour as earth lead in and including provn of MS sunk terminal box of appropriate size suitable for flush to wall for mounting switch, sockets, fan regulators etc with 3mm thick hylum sheet top cover with screws & cup washers for one light / fan point / call bell complete including dismantiling of old unserviceable aluminium /coper wiring from existing concealed conduit all as per specified and directed by Eng-in-charge.. NOTE : Cost of making good the disturbed surfaces (if any) matching with the existing surface is deemed to be included in the unit quoted rates.
M&L for point wiring with two single core PVC insulated, unsheathed, multistranded copper conductor of size 1.5 sqmm and one single core PVC insulated unsheathed stranded copper conductor of size 1.50 sqmm green in colour as earth lead in and including PVC rigid casing caping (medium grade) with all fittings & accessories including provn of MS sunk terminal box of minimum size 75 x75 mm fixed flush to wall for mounting switch, socket, fan regulator etc with 3mm thick hylum sheet top cover with screws & cup washers for one light / fan point / complete. NOTE : Cost of making good the disturbed surfaces (if any) matching with the existing surface is deemed to be included in the unit quoted rates.
All as per item No 69.00 here in before but for 5 pin, 5/6 A socket point on the independent board complete.
All as per item No 69.00 here in before but for 5 pin, 5/6 A socket point on the as the same board complete.
All as per item No 69.00 here in before but with two single core PVC insulated, unsheathed, multistranded copper conductor of size 4 sqmm and one single core PVC insulated unsheathed stranded copper conductor of size 4 sqmm green in colour as earth lead for 15/16 A switch-socket point on independent board complete.
S & F switch piano flush type single, pole one way, 5 Amp complete
S&F ceiling rose, surface bakelite 3/2 terminal complete
S & F switch socket combination 5 in 1, 5/6A complete
S & F socket outlet only 5 in 1,5A/ complete
S & F switch socket combination 5 in 1, 15/16A complete
S&F modular switch one way 6 Amps 230 volts,1 module all as specified and as directed by the Engineer in charge
S&F modular bell push switch one way 6 Amps 230 volts,1 module all as specified and as directed by the Engineer in charge
S&F modular switch one way with indicator 16 Amps 230 volts,1 module all as specified and as directed by the Engineer in charge
S&F modular socket 2 in 1, 2/3 pin ,6 Amp all as specified and as directed by the Engineer in charge.
S&F modular socket 3 pin, 6 Amp-16 Amp combined shuttered specified and as directed by the Engineer in charge.
S&F modular white cover plate with frame 1 module inclusive of inner & outer plate complete all as specified and as directed by the Engineer in charge.
S&F modular white cover plate with frame 2 module inclusive of inner & outer plate complete all as specified and as directed by the Engineer in charge.
S&F modular white cover plate with frame 3 module inclusive of inner & outer plate complete all as specified and as directed by the Engineer in charge.
S&F modular white cover plate with frame 4 module inclusive of inner & outer plate complete all as specified and as directed by the Engineer in charge.
S&F modular white cover plate with frame 6 module inclusive of inner & outer plate complete all as specified and as directed by the Engineer in charge.
S & F modular metal flush box 1/2 module all as directed.
S & F modular metal flush box 3 module all as directed.
S & F modular metal flush box 4 module all as directed.
S & F modular metal flush box 6 module all as directed.
S&F modular fan step regulator, 120W, 230 volts,2 module all as specified and as directed by the Engineer in charge
S&F electronic step regulator (speed regulation in 5 steps) suitable for ceiling fan 1200/1400mm sweep, 120 Watt complete
S&F in repair decorative box type fitting with LED retrofit tube 10 watt 2 feet with Aluminium extruded batten luminaire for 230 volt AC,including LED tube 10 Watt complete all as directed by Engineer-in-Charge
S&F in repair decorative box type fitting with LED retrofit tube 21 watt with Aluminium extruded batten luminaire for 230 volt AC,including LED tube 21 Watt complete all as directed by Engineer-in-Charge
S & F energy saving decorative LED post top lantern with diffuser and painted aluminium deflector 30 W with base including making necessery fixing and connection arrangements complete all as specified and directed.
Fixing only serviceable light fittings, any type recovered from item No.63.00 including making necessery end connections with suitable wire all as directed.
S&F MCB, DB, TPN, 4 ways DOUBLE DOOR, IP-42, IK-09 with arcylic door, rated bus bars, earth bar, neutral links complete incl. blanking plates as required & fixed flush to wall and making good the disturbed surfaces complete all as specified and as directed including dismantling taking down unsv one with MCBs complete.
All as per item No 98.00 here in before but SPN 12 way complete
All as per item No 98.00 here in before but SPN 8 way complete
S&F MCB, SP, 10KA, 230V, "C" curve, 06-32 A, ISI Marked complete
S&F MCB, DP, 10KA, 415V, "C" curve, 06-32 A, ISI Marked complete
S&F MCB, TPN, 10KA, 440V, "C" curve, 40 A, ISI Marked complete
S&F in repair exhaust fan AC, single phase, 230/240 V, of size 300 mm sweep steel/aluminium metal body incl making holes on wall & making good the distrubed surfaces with all connecting arrangements complete.
M&L for submain wiring with casing caping two single core PVC insulated, unsheathed, stranded copper conductor of size 6.0 Sqmm one single core PVC insulated, unsheathed solid copper conductor 6.0 Sqmm green in colour as earth lead in existing concealed PVC conduit wiring with all fitting & accessories incl taking down old unsv aluminium sub-main wiring from existing concealed conduit complete all as specified and directed by Eng-in-Charge
M&L for submain concealed wiring with two single core PVC insulated, unsheathed, stranded copper conductor of size 4.0 Sqmm one single core PVC insulated, unsheathed solid copper conductor 4.0 Sqmm green in colour as earth continuity conductor drawn into PVC conduit (medium grade) with all fitting & accessories incl taking down old unsv sub-main wiring complete .
M&L for submain wiring with casing caping two single core PVC insulated, unsheathed, stranded copper conductor of size 4.0 Sqmm one single core PVC insulated, unsheathed solid copper conductor 4.0 Sqmm green in colour as earth lead in existing concealed PVC conduit wiring with all fitting & accessories incl taking down old unsv aluminium sub-main wiring from existing concealed conduit complete all as specified and directed by Eng-in-Charge
M&L for earthing complete with galvanized steel earth plate electrode 600x600x 6mm burried directly in ground (in vertical position) earth pit not less then 2.25 mtr below narmal ground level with the top edge of the earth plate not less than 1.5 mtr (B.G.L) and connected to galvanized iron earth wire of 4mm dia GI wire with GI protection pipe upto pole junction box by means of bolts, nuts, check nuits, and washer of galvanized iron including PCC (1:2:4) type B1 precast RCC cover slab with suitable handle made of 6 mm round bar, including necessary excavation and earth work in any type of soil, 20 mm dia med grade galvanized steel tube for watering with one end fixed with cast iron funnel and wire mess, 20 bore light grade galvanized steel tubing up to 7.5 mtr lenght for drawing earth lead GU wire protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No. 3 of SSR part 1 and testing on completion incl taking down old unsv earthing complete.
M/S Dutta Das Engineering Co
CHANDAN TRADERS
JHA CONSTRUCTION AND CO
SHRI JIBANDHAN PAUL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .