Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.5 LAccepted-AOC | L1 | Accepted-AOC founf lowest and reasonable and accepted | |
| 2 | L2₹16.8 L+₹1.3 L (8.52%)Rejected-Finance | L2 | Rejected-Finance being not L1 | |
| 3 | L3₹20.4 L+₹4.9 L (31.6%)Rejected-Finance | L3 | Rejected-Finance being not L1 |
| Sl No | Description | Qty | Unit | PRABHAT ENGINEERING SOLUTION AND SERVICES L2 | KUKREJA BROTHERS L3 | KPS ELEVATORS AND COMPANY L1 |
|---|---|---|---|---|---|---|
| 1.00 | Supply, Installation,Testing and commissioning of 5 KWp off Grid type Solar system comprising mono crystalline PV Panel minimum 545Wp x 10 Nos (or nearest size suitable for 5KW supply) with Lithium-ion batteries and including mounting GI structure with tilt angle of 15-20 degree for maximum absorption of sun light as recommended by manufacturer and array junction box, module mounting structure, including taxes all as per MNRE Policy all as specified and as directed. The following items are included in this solar power system :-
Notes:- (i) The rate quoted by the lowest bidder are deemed to be included for the following provisions :- | 2 | Each Job | 4,95,999 ₹9,91,998 | 5,70,000 ₹11,40,000 | 4,00,000 ₹8,00,000 Lowest |
| 1.01 | Photo Voltaic (PV) Modules : Mono Crystelline Solar Modules > 545Wp(Nominal), 72 Mono Perc (144 half-Cells), Voc ~ 50.14, Isc ~ 13.55 A, Vmp ~ 42.02 V, Imp ~ 12.98,Efficiency not less than 20.0%, Junction Box IP65,4T with 3 Diodes,
Make: Tata power solar /Vikram solar/Waaree Energies/ adani solar. | - | - | - | - | - |
| 1.02 | Each PVC module must use a RF identification tag (RFID), which must contain the following information : (i) Name of the manufacturer of PV Module (ii) Name of the Manufacturer of Solar cells (iii) Month and year of the manufacture (separately for solar cells and module) (iv) Country of origin and both solar cells and modules shall comply with domestic content requirement & shall be made in india (separately for solar cells and module) (v) I-V curve for the module (vi) Peak Wattage, lm Vm and FF for the module) (vii) Unique Serial No and Model No of the module (viii) Date and year of obtaining IEC PV module qualification certificate (ix) Name of the test lab issuing IEC certificate (x) Other relevant information on traceability of module as per ISO 9000 series. Note: RFID shall be mandatorily placed inside the module laminate. | - | - | - | - | - |
| 1.03 | PV modules used in solar power plants/ systems must be designed for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. PV modules shall have product warranty of 10 years after completion of work. | - | - | - | - | - |
| 1.04 | Silicon Mono Crystalline SPV cells shall be used in the Solar Photo voltaic module. SPV modules should be essentially indigenously manufactured (manufactured in India and shall comply with domestic content requirement). | - | - | - | - | - |
| 1.05 | Mounting structure : To Support the PV Modules, Well designed Galvanized Mild Steel Mounting Structure made of Angles /Pipes/Flats as per latest IS 2062:2011 with GI Coating as per IS 4759 and designed to handle wind speed of 100 km/Hr, with Suitable leak proof mounting Fastners and heavy duty Nut Bolts and Washers of stainless steel of grade SS 304, all inclusive necessary Civil Foundation work as required at site as per direction of Engineer in charge. Note : The drawing along with design structure should be submitted by contractor from vetted By NIT/MNRE approved institute before execution of work. | - | - | - | - | - |
| 1.06 | Off Grid Inverter :- IGBT based single Phase Inverter of 5 KW , 240V,50 Hz Capacity, having MPPT Tracker (200-240V) with SPD, Class 1 &2 Surge protection devices having efficiency 98%, Graphical Displays+ LED,interfaces with Ethernet.USB,RS485,SO Output, Suitable for ambient temperature -20 to +60 Degree Centigrade,Protection IP65, Fuse Protection DC input Plus and minus, Overvoltage Protection Type 1+2, Night Consumption not more than 1.5KW, with LAN Monitoring System. compatible with solar/DG/Main supply.
Make: ABB/Delta/Luminious/UTL. | - | - | - | - | - |
| 1.07 | Array junction box :-Suitable Array Junction Box to connect Strings of panels, IP 65 Protection,1000V DC SPD TypeII,With MC4 Connectors,Earhing Gland with Terminals blocks.
Makes for internal components:Polycab /L&T/ Schneider
ACDB:-IP 65 Protection AC I/P and O/P connection box with AC SPD TypeII,,Earthing Gland with Terminals blocks.
Makes for internal Components Polycab /L&T/ Schneider | - | - | - | - | - |
| 1.08 | Cables and wires :-
(a) 2.5 Sqmm Weather proof DC copper Cable
(b) 4 Sq mm 2 Core Flexible Copper Cable
( c)16 Sqmm 2 core aluminium armoured Cable
Note :- Qty of wire should be provided as per site requirement/ OEM instruction from SV panel to Invertor/AJB/ACDB and invertor to main DB and main DB to invertor.
Make: Polycab/Finolex/Havells. | - | - | - | - | - |
| 1.09 | Supply ,testing & commisioning of Lithium-Ion battery 12V-200AH -08 Nos with syncronisal with invertor complete All as directed & specified by Engr-in-charge.
Make:-EXIDE /AMARON /LUMINIOUS | - | - | - | - | - |
Tender Value
₹21.3 L
EMD Value
₹43,000
Closing Date
3 Oct 2025, 6:00 pmClosed
GE (U) Meerut Cantt
Roorkee road Meerut Cantt
PROVN OF 2 X 5 KVA SOLAR CONTROLLER UNITS WITH ACCESSORIES FOR P-19 (ADM BLOCK) AND P-26 (OFFR MESS) AND 3 X 2 KVA POWER CONTROLLER UNITS WITH ACCESSORIES FOR SECURITY POST NO. 6,7 AND 8 OF SECTOR 7, ZONE 3 AT 2AHQSR UNDER GE(U) MEERUT CANTT.
2025_MES_719591_2
8725/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
Meerut Cantt
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE (U) Meeerut Cantt
₹43,000
Yes
3 Dec 2025
9 Sept 2025
10 Oct 2025
9 Sept 2025
3 Oct 2025
19 Sept 2025
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .