Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical 88 GIRRAJ NAGAR KALWAD ROAD JOTHWARA JAIPUR 302012 JAIPUR CITY NORTH RAJASTHAN 302012 | JAIPUR | RAJASTHAN | 302012 | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical 306 BAKSHI HOUSE 40 41 NEHRU PLACE NEW DELHI 110019 DELHI | SOUTH EAST | DELHI | 110019 | Admitted-Fee/PreQual/Technical |
Tender Value
₹43.1 L
EMD Value
₹86,300
Closing Date
5 Mar 2026, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Regsitrar
Central University of Rajasthan NH 8, Bandarsindari
Supply, Installation, Testing and Commissioning of Air- Conditioners in l0 Nos. Smart Classrooms at Central University of Rajasthan
2026_CURAJ_898030_1
CURAJ/R/F.172/2026/3767 DATE 06.02.2026
Open Tender
Electrical Works
Works
Central University of Rajasthan
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹86,300
30 Mar 2026
11 Feb 2026
6 Mar 2026
11 Feb 2026
5 Mar 2026
11 Feb 2026
11 Feb 2026 - 27 Feb 2026
PART - A: SITC of Ductable Split Type Air Conditioners SUPPLY OF DUCTABLE AC s
Supply of 8.5 TR (+-05%) capacity Ductable Air conditioning units (indoor+outdoor) with inverter technology, Scroll Compressor, Ecofriendly Refrigerant, vibration isolators, suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. Each unit shall comprise of separate indoor and outdoor unit.
INSTALLATION, TESTING AND COMMISSIONING OF DUCTABLE AC s:
Installation, Testing and Commissioning of Ductable Air conditioning Units (indoor & outdoor units) complete with all components such as M.S. Epoxy Painted Stand for condensing unit with vibration isolators, grouting for Bracket type stand without railing & catwalk, core cutting of holes in beam or slab (only with specific approval of Engineer-In-Charge) & finishing the same with provision of sleeves, mounting arrangement for units comprising anchor fasteners, clits, support rods, vibration isolators, Epoxy painted MS angles/ channel as per site requirements including charging of additional refrigerant required on site in accordance with the extra inter-connectiong copper pipeline as per OEM Norms as per standard practice and directions of EIC.
REFRIGRANT COPPER PIPE, INTERCONNECTIONG MICROPRECESSOR BASED CABLE & DRAIN PIPE:
Supply, Installation, Testing and Commissioning of interconnecting refrigerant copper pipe of suitable size as per OEM Norms along with microprocessor based communication copper cable of suitable size as per OEM Norms to interconnect outdoor and indoor unit, including insulated closed cell electrometric nitrile rubber/foam tubular insulation as per OEM Norms between each set of indoor & outdoor unit, including nitrogen pressure testing. All piping inside the room shall be properly fixed/supported with suitable size of clamp/ M.S. hanger and all external/exposed to sun piping shall run in M.S. painted cable tray as per standard practice and directions of EIC.
Providing & Fixing of IS : 4985 - 2000 Class - 4 (10 Kg / Sqcm) 25/32 mm UPVC drain water piping with fittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, tee, solvent cement jointing, support with MS hanger on ceiling or recessed in wall with chasing & plastering with 6 mm thick closed cell elastomeric nitrile rubber insulation including leakage testing etc. as required of following nominal sizes as approved by the EIC.
ACOUSTICALLY TREATED PLANUM:
Supply, Installation, Testing and Commissioning of acoustically treated & powder coated supply air planum, faricated with 22 gauge GI sheet, complete with acoustic insulation of 10 mm thick open cell nitrile rubber sheet etc. as required on site as per standard practice and directions of EIC.
Supply & fixing of powder coated aluminium eye ball of 300 mm diameter, for supply air and suitable for required system, as per standard practice and directions of EIC.
ELECTRICAL WORK:
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit / cable tray as required including making end connection and as per directions of EIC.
4 X 6 sq. mm
3 X 2.5 sq. mm
PART - B: SITC of High Wall Split Type Air Conditioners. Supply of high wall split type AC s
Supply, Installation, Testing and Commissioning of wall mount, cold, split type AC Units (indoor & outdoor) of following specifications as per IS along i/c handling charges etc. complete in all respects, as per standard practice and directions of EIC. Power Ratings: 01 phase, 230 V, 50 Hz, AC Supply Compressor: Roraty/Dual Rotary type Coil Material (evaporator & condensor): Copper Remote Control: Included AC Technology: Inverter BEE Star Rating: minimum 03 Star Eco friendly Green Refrigerant Gas Cooling & condenser copper pipe line along with round electric cable: Inclusive of 03 mtr minimum.
1.8-2.0 TR or equivalent.
Pdg. & fixing of extra cooling & condensing copper pipe line along with round electric cable of "stranded copper conductor, PVC insulated & PVC Sheathed" as per IS for connections from outdoor unit to indoor unit/voltage stabilizer etc. as reqd, as per standard practice, suitable for Split AC of 1.8-2.0 TR or equivalent capacity as per respective OEM standards.
Pdg. & fixing of extra UPVC drain pipe along with accessories etc. as reqd., as per standard practice and directions of EIC.
Pdg. & fixing of high wall split AC outdoor unit floor/wall stand along with accessories etc. as reqd., as per standard practice and directions of EIC.
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.68 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.97 MB
BOQ_943926.xls
BOQ • 0.28 MB
NITSITCofACSmartClassrooms.pdf
Tender Documents • 2.96 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .