| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1ST LOWEST₹23.8 LAccepted-AOC TUEM PEDNEM GOA | GOA | 1ST LOWEST | Accepted-AOC lowest |
Tender Value
₹22.7 L
EMD Value
₹45,402
Closing Date
11 Dec 2021, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Electricity dept, Div-VI Ansabhat, Mapusa
Work of erection of new 200KVA DTC at Sateri Nagar Verla to reduce existing feeder loading and to solve low voltage faced by the locals of Sateri Nagar Verla
2021_ED_948_1
Tender 05(2021-22)/ TECH/DIV-VI/21-22 38
Open Tender
Electrical Works
Item Rate
90 days
Verla Canca, Mapusa
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
₹45,402
Yes
6 Sept 2023
29 Oct 2021
13 Dec 2021
29 Oct 2021
11 Dec 2021
29 Oct 2021
180 days
Amount
Cost of Material
Supply and Erection HDGI Cut point of 75 x 40 x 7.3 mm Channel 1.3 Mtr long as per the drawing No EE/IV/11 KV/X-Arms as per annexure confirming to IS - 2633/72or the latest version thereof
Supply and Erection of Break insulators 8 KV (44KN) as per the drawing No. CEE/E-425 as per annexure confirming to the IS:5300-1969 or the latest version thereof
Supply and Erection 11 KV brown glazed ball and socket type disc insulators as per the drawing No. CEE/E-128 conforming to IS:2486 Pt No.1 to 4 and type 46 of IS-3188/80 as ammended upto date for a minimum failing load of 45KN with minimum creepage distance of 320 mm with16mm ball and socket alternative `B'
Supply and Erection of Metal parts for 11 KV disc 45 KN, 3 bolted type as per IS-2486 part - II& III /1974 as ammended upto date& 3 `U' bolted type tension/ suspension clamp.
Supply and Erection of LT brown glazed shackle Insulator of size 100 mm x 115 mm conforming to fig No. 4 and type 2 fo IS: 1445/77 as amended upto date. Minimum failing load shall be 16 KN with GI hardware suitable for LT shackle insulator of size 100 x 115 mm conforming to type 2 fig 4 of IS: 1445/77 as amended upto date as per the drawing No.EE/X/TRN/DRG1/2.
Supply and Stringing of AAC 'ANT' Conductor, hard drawn stranded aluminium conductor & conforming to IS:398(Pt-I/76) with ammendment no. 1,2 & 3 & of size 7/3.10mm aluminium, (nominal aluminium area 50mm)
Supply and Stringing of AAC 'GNAT' Conductor, hard drawn stranded aluminium conductor & conforming to IS:398(Pt-I/76) with ammendment no. 1,2 & 3 & of size 7/2.21mm aluminium, (nominal aluminium area 25mm2)
Supply and Stringing of Hard drawn stranded aluminium conductor galvanized steel reinforced & conforming to IS:398(Pt-II/96) with amendment no. 1 & 3 & of size 6/2.59 mm aluminium, 1/2.59 mm steel wire "WEASEL"
Supply and Erection PVC insulated single core cable 50 mm2 for D.P. earthing
FRP Fencing complete with Gate as per specification for Distribution Transformer (Size 3Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6
Supply and Erection 200 KVA 11kv/.4kv Distribution Transformers level II losses, Alluminium Winding, with Bimetallic Terminal Connectors, Energy Efficiency Level-II as per IS: 1180 (Part-I): 2014
Supply and Erection DTC Metering Unit
Supply and Erection Modem for Automatic Meter Reading
Supply and Erection of MS Distribution box as per drg No. CEE/E-689 Revision No. 2 along with MCCB 400 A, Bus bar made out of Aluminium strips 40 x 10 mm, Other accessories & 200 Amps, Porcelain KitKat Fuse Carrier & Base with extended terminals shall be as per drawing No.CEE/E/543-Rev 4 (Set of 3) for 4 feeder arrangement with 1 no of moulded case circuit breaker (MCCB) of 400A, 415V, AC 50 Hz for 200 KVA Distribution Transformer centre
Supply and Erection Enamelled Danger board 400V of size 250mm x 200 mm as per the drawing No. CEE/E-490.
Supply and Erection Anticlimbing deviceas per the drawing No. CEE/E-478.
Supply and Erection HDGI DP Structural material shall include :-a) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for incoming line & installation of disc insulators b) GI channel ISMC75x40x7.3mm 2.75mtrs long 2 pieces for GOAB switch c) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for HG fuses d) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for installation of lightening arrestor e) GI channel ISMC 100x50x7.3mm 2.75 mtrs long 2 pieces for installation of Trasformer f) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for side support of trasformer g) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 4 pieces for installation of any other items h) GI channel ISMC 100x40x7.3mm 0.52 mtrs long 2 pieces for installation of Transformer base channel
Supply and Erection HDGI Structural material for 11 KV GOAB Switch
Earthing complete comprises of H.D.G.I. Pipe of class B length 2.5 mts , 40mm nominal bore(outside diameter 48.8mm maximum and 47.9mm minimum ,thickness4.0mm and mass of tube plain end 4.37kg/m) conforming to IS1239 Part 1 1990 asamended upto date and hot dip zinc coating shall conform to IS 4736 as ACSR'Weasel' Conductor( quantity as required) , pit filled with homogeneous layer of20 kgs of charcoal, sand and salt as per the drawing No. CEE/E-829
GI Flat 25 x 5 mm.
Supply and Erection XLPE Single Core unarmoured 300 sq mm,cross linked polyethelene insulated, PVC shealthed 1 core 185 sqmm cable 1.1.KV gradesuitable for 3 phase earthed system and conforming to IS: 7098 (Part-I)/1988 as amended upto date.
Supply and Erection of Aluminium crimping Lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade IE of IS: 5082/1969 suitable for aluminium cable of 300 sq.mm
Supply, Erection Tesing and Commissioning of 11KV, 630 Amps, Outdoor, SF6 Ring Main Unit with two Load Break Switches and One Circuit Breaker as per the specifications enclosed
Supply, storage transportation to work site, laying termination, testing and commissioning of XLPE cable of voltage 11 KV 3 core 185 Sq.mm excluding cable end termination.in accordance with the IS: 7098 (Part-2) and shall also conform to the requirements of internationally accepted standards IEC 60502-2(applicable clause only) for construction and IEC 60840 for testing(Double Run Cable)
Supply, storage transportation to work site, laying termination, testing and commissioning of XLPE cable of voltage 11 KV 3 core 95 Sq.mm excluding cable end termination.in accordance with the IS: 7098 (Part-2) and shall also conform to the requirements of internationally accepted standards IEC 60502-2(applicable clause only) for construction and IEC 60840 for testing.
H.S.11 KV Heat shrinkable XLPE termination kit for 3 x 185 Sq.mm. Cable indoor type Suitable for heavily polluted atmosphere conditions with total creepage distance of 31mm/KV & protected creep age distance of not more than 50% of the total creep age distance, complying to IS:1255-1983.
H.S.11KV Heat shrinkable XLPE termination kit for 3 x 185 Sq.mm. Cable Outdoor type Suitable for heavily polluted atmosphere conditions with total creepage distance of 31mm/KV & protected creep age distance of not more than 50% of the total creep age distance, complying to IS:1255-1983.
H.S.11 KV Heat shrinkable XLPE termination kit for 3 x 95 Sq.mm. Cable indoor type Suitable for heavily polluted atmosphere conditions with total creepage distance of 31mm/KV & protected creep age distance of not more than 50% of the total creep age distance, complying to IS:1255-1983.
H.S.11KV Heat shrinkable XLPE termination kit for 3 x 95 Sq.mm. Cable Outdoor type Suitable for heavily polluted atmosphere conditions with total creepage distance of 31mm/KV & protected creep age distance of not more than 50% of the total creep age distance, complying to IS:1255-1983.
Supply & laying of sand.
Sand for cushioning of HT underground cables.
GI Pipe 100 mm , class B
Supply and laying of RCC protective cover of size 600 mm long x 250 mm width and 50 mm thick capable of bearing load of 135 Kg. And covered with earth / sand upto depth of 0.15 mts. Confirming to IS 1255 - 1967 at non-road crossing.
Bricks class design 75 kg/cm2 (1st class wire cut)
Cable route Markers as per the drawing No. DIV IV/UG2
Warning tape.
Erection/Dismantling (Dismantled materials to be handed over to concerned Sub Division)
Supply and Erection of RCC pole 11 mtr as per the drawing No.CEE/E-698 REV-3 as per annexure confirming to IS 785-1998 as amended upto date. The component used for pole shall conform to following IS amended up to date. 1) Ordinary Port land cement 53 grade IS 12269 2) Aggregate IS 383-1970 3) Torsteel IS 1786-7985 4) MS bar IS 432 p 1 & 2-1982
Supply and Erection HDGI 2 pin 'X' arm of 75 x 40 Channel as per the drawing No.CEE/E/704 as per annexure confirming to IS- 2633/72 or the latest version thereof
Supply and Erection HDGI 4 pin 'X' arm of 75 x 40 Channel as per the drawing No.CEE/E/705 as per annexure confirming to IS- 2633/72 or the latest version thereof.
Supply and Erection HDGI Cut point of 75 x 40 x 7.3 mm Channel 1.3 Mtr long as per the drawing No EE/IV/11 KV/X-Arms as per annexure confirming to IS - 2633/72or the latest version thereof
Supply and Erection HDGI X arm clamps for RCC Pole 11.00 mtr L.A as per the drawing No.CEE/E-711 as per annexure confirming to IS- 2633/72 or the latest version thereof
Supply and Erection HDGI stay clamps for RCC Pole 11.00 Mts L.A.as per the drawing No.CEE/E-711 as per annexure confirming to IS- 2633/72 or the latest version thereof
Supply and Erection of HDG.I. stay wire 7/10 SWG conforming to IS-2141/1979 grade- I, IS:4826-1979 & IS:6594-1974 or latest version thereof with tensile grade 4 & having minimum tensile strenght of 700N/mm2 conforming to IS:2141 or the latest version thereof
Supply and Erection of H.D.G.I. stay rod of 1200mm long and 16mm dia with an eye band of internal dia 40mm at one end and threaded up to length of 200mm at the other end galvanised. H.D.G.I.stay plate of 450x450x8mm size with a hole drilled at the centre to suit 16mm dia GI rod galvanised.as per the drawing No. CEE/E-465
Supply and Erection G.I. Turn Buckle with eye bolt 11 KV as per the drawing No. CEE/E-466
Supply and Erection of Break insulators 8 KV (44KN) as per the drawing No. CEE/E-425 as per annexure confirming to the IS:5300-1969 or the latest version thereof
G.I. Nuts & Bolts as per annexure confirming to the IS- 2633/72 or the latest version thereof
Supply and Erection 11 KV brown glazed ball and socket type disc insulators as per the drawing No. CEE/E-128 conforming to IS:2486 Pt No.1 to 4 and type 46 of IS-3188/80 as ammended upto date for a minimum failing load of 45KN with minimum creepage distance of 320 mm with16mm ball and socket alternative `B'
Supply and Erection of Metal parts for 11 KV disc 45 KN, 3 bolted type as per IS-2486 part - II& III /1974 as ammended upto date& 3 `U' bolted type tension/ suspension clamp.
Supply and Erection of LT brown glazed shackle Insulator of size 100 mm x 115 mm conforming to fig No. 4 and type 2 fo IS: 1445/77 as amended upto date. Minimum failing load shall be 16 KN with GI hardware suitable for LT shackle insulator of size 100 x 115 mm conforming to type 2 fig 4 of IS: 1445/77 as amended upto date as per the drawing No.EE/X/TRN/DRG1/2.
Supply and Erection Metal parts for L.T. Shackle insulators or the Strap type fittings shall consists of a pair of H.D.G.I. straps, 2nos. H.D.G.I. bolts with hexagonal head & nuts, 2 nos. H.D.G.I. spring washers, & helically formed conductor dead-end fittings made of aluminium alloy or aluminium-clad steel conforming to the relevant IS specifications as per the drawing No.EE/X/TRN/DRG1/2.
Removing and Restringing of AAC 'ANT' Conductor, hard drawn stranded aluminium conductor & conforming to IS:398(Pt-I/76) with ammendment no. 1,2 & 3 & of size 7/3.10mm aluminium, (nominal aluminium area 50mm)
Removing and Restringing of AAC 'GNAT' Conductor, hard drawn stranded aluminium conductor & conforming to IS:398(Pt-I/76) with ammendment no. 1,2 & 3 & of size 7/2.21mm aluminium, (nominal aluminium area 25mm2)
Supply and Stringing of AAC 'ANT' Conductor, hard drawn stranded aluminium conductor & conforming to IS:398(Pt-I/76) with ammendment no. 1,2 & 3 & of size 7/3.10mm aluminium, (nominal aluminium area 50mm)
Supply and Stringing of AAC 'GNAT' Conductor, hard drawn stranded aluminium conductor & conforming to IS:398(Pt-I/76) with ammendment no. 1,2 & 3 & of size 7/2.21mm aluminium, (nominal aluminium area 25mm2)
Supply and Stringing of Hard drawn stranded aluminium conductor galvanized steel reinforced & conforming to IS:398(Pt-II/96) with amendment no. 1 & 3 & of size 6/2.59 mm aluminium, 1/2.59 mm steel wire "WEASEL"
Supply and Erection PVC insulated single core cable 50 mm2 for D.P. earthing
FRP Fencing complete with Gate as per specification for Distribution Transformer (Size 3Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6
Supply and Erection 200 KVA 11kv/.4kv Distribution Transformers level II losses, Alluminium Winding, with Bimetallic Terminal Connectors, Energy Efficiency Level-II as per IS: 1180 (Part-I): 2014
Supply and Erection 11 KV rated voltange GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming toIS-9921 (Part-I to IV) [ 1981 - 85] as amended up to date and detailed specification eclosed herewith. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufacturer of the insulators and have minimum 320 mm creepage distance and AB switchs contacts shall be of copper/ copper alloy. The AB switch shall be of following current rating: 200 A
Supply and Erection 11 KV rated voltange GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming toIS-9921 (Part-I to IV) [ 1981 - 85] as amended up to date and detailed specification eclosed herewith. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufacturer of the insulators and have minimum 320 mm creepage distance and AB switchs contacts shall be of copper/ copper alloy. The AB switch shall be of following current rating: 400 A
Supply and Erection of 9 KV, 5 KA nominal discharge current metal oxide gapless distribution class Lightning arrestor conforming to IEC-600994-4 and IS: 3070 part 3 1993 as amended upto date suitable for 11 KV 50 HZ effectively earthed neutral system with necessary mounting arragements and connector suitable to connect ASCR conductor upto overall diameter 12.30 mm
11 KV , 200 A Horn gap fuse unit (Set of three) shall be as per drg No. CEE/E-786 as per annexure confirming toI.S. 2062,IS: 1367,IS: 4218,IS: 1363,IS-209 1979 or the latest version thereof
Supply and Erection DTC Metering Unit
Supply and Erection of MS Distribution box as per drg No. CEE/E-689 Revision No. 2 along with MCCB 400 A, Bus bar made out of Aluminium strips 40 x 10 mm, Other accessories & 200 Amps, Porcelain KitKat Fuse Carrier & Base with extended terminals shall be as per drawing No.CEE/E/543-Rev 4 (Set of 3) for 4 feeder arrangement with 1 no of moulded case circuit breaker (MCCB) of 400A, 415V, AC 50 Hz for 200 KVA Distribution Transformer centre
Supply and Erection Enamelled Danger board 400V of size 250mm x 200 mm as per the drawing No. CEE/E-490.
Supply and Erection Anticlimbing deviceas per the drawing No. CEE/E-478.
Supply and Erection HDGI DP Structural material shall include :-a) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for incoming line & installation of disc insulators b) GI channel ISMC75x40x7.3mm 2.75mtrs long 2 pieces for GOAB switch c) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for HG fuses d) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for installation of lightening arrestor e) GI channel ISMC 100x50x7.3mm 2.75 mtrs long 2 pieces for installation of Trasformer f) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for side support of trasformer g) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 4 pieces for installation of any other items h) GI channel ISMC 100x40x7.3mm 0.52 mtrs long 2 pieces for installation of Transformer base channel
Supply and Erection HDGI Structural material for 11 KV GOAB Switch
Earthing complete comprises of H.D.G.I. Pipe of class B length 2.5 mts , 40mm nominal bore(outside diameter 48.8mm maximum and 47.9mm minimum ,thickness4.0mm and mass of tube plain end 4.37kg/m) conforming to IS1239 Part 1 1990 asamended upto date and hot dip zinc coating shall conform to IS 4736 as ACSR'Weasel' Conductor( quantity as required) , pit filled with homogeneous layer of20 kgs of charcoal, sand and salt as per the drawing No. CEE/E-829
GI Flat 25 x 5 mm.
Supply and Erection XLPE Single Core unarmoured 300 sq mm,cross linked polyethelene insulated, PVC shealthed 1 core 185 sqmm cable 1.1.KV gradesuitable for 3 phase earthed system and conforming to IS: 7098 (Part-I)/1988 as amended upto date.
Supply and Erection of Three and half core armoured XLPE cable of size 120 Sq.mm cross linked polyethelene insulated, PVC shealthed 3.5 core 120 sqmm cable with galvanized steel strip armoured aluminium cable of 1100 volts grade suitable for 3 phase earthed system and conforming to IS: 7098 (Part-I)/1988 as amended upto date.
Supply and Erection of Aluminium crimping Lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade IE of IS: 5082/1969 suitable for aluminium cable of 120 sq.mm
Supply and Erection of Aluminium crimping Lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade IE of IS: 5082/1969 suitable for aluminium cable of 300 sq.mm
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in s per the drawing No EE-IV/DRG/CABLE TRENCH
Supply, Erection Tesing and Commissioning of 11KV, 630 Amps, Outdoor, SF6 Ring Main Unit with two Load Break Switches and One Circuit Breaker as per the specifications enclosed
Supply, storage transportation to work site, laying termination, testing and commissioning of XLPE cable of voltage 11 KV 3 core 185 Sq.mm excluding cable end termination.in accordance with the IS: 7098 (Part-2) and shall also conform to the requirements of internationally accepted standards IEC 60502-2(applicable clause only) for construction and IEC 60840 for testing(Double Run Cable)
Supply, storage transportation to work site, laying termination, testing and commissioning of XLPE cable of voltage 11 KV 3 core 95 Sq.mm excluding cable end termination.in accordance with the IS: 7098 (Part-2) and shall also conform to the requirements of internationally accepted standards IEC 60502-2(applicable clause only) for construction and IEC 60840 for testing.
H.S.11 KV Heat shrinkable XLPE termination kit for 3 x 185 Sq.mm. Cable indoor type Suitable for heavily polluted atmosphere conditions with total creepage distance of 31mm/KV & protected creep age distance of not more than 50% of the total creep age distance, complying to IS:1255-1983.
H.S.11KV Heat shrinkable XLPE termination kit for 3 x 185 Sq.mm. Cable Outdoor type Suitable for heavily polluted atmosphere conditions with total creepage distance of 31mm/KV & protected creep age distance of not more than 50% of the total creep age distance, complying to IS:1255-1983.
H.S.11 KV Heat shrinkable XLPE termination kit for 3 x 95 Sq.mm. Cable indoor type Suitable for heavily polluted atmosphere conditions with total creepage distance of 31mm/KV & protected creep age distance of not more than 50% of the total creep age distance, complying to IS:1255-1983.
H.S.11KV Heat shrinkable XLPE termination kit for 3 x 95 Sq.mm. Cable Outdoor type Suitable for heavily polluted atmosphere conditions with total creepage distance of 31mm/KV & protected creep age distance of not more than 50% of the total creep age distance, complying to IS:1255-1983.
Back Filling up of available excavated earth (excluding rock/stones) in trenches, plinth, sides, foundations etc. in layer not exceeding 0.2 mtrs. depth consolidation each deposited layer by ramming and watering (1 x 0.4 x 230)
Disposal of surplus earth
GI Pipe 100 mm , class B
Cable route Markers as per the drawing No. DIV IV/UG2
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .