Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.2 LAccepted-AOC 01 ENTERPRISES | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹21.9 L+₹1.4 L (6.60%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹22.8 L+₹2.3 L (11.0%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹25.3 L+₹4.7 L (22.8%)Rejected-Finance | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹26.3 L+₹5.7 L (27.6%)Rejected-Finance 2549 NATHA SINGH STREET MEHNA MOHALLA BATHINDA PB 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹33 L
EMD Value
₹66,000
Closing Date
7 Dec 2019, 6:00 pmClosed
CWE Bathinda
HQ CWE Bathinda, Bathinda Military Station
Special repairs to Bldg No P 128 OTM Accn of Corps Camp under GE (North) Bathinda at Bathinda Mil Stn
2019_MES_294756_1
CA NO CWE BTD 39 of 2019-20
Open Tender
Civil Works
Item Rate
180 days
Bathinda Mil Station
As per NIT
7 documents required · 7 mandatory
₹500
GE North Bathinda
₹66,000
Yes
7 Jan 2020
4 Nov 2019
9 Dec 2019
4 Nov 2019
7 Dec 2019
27 Nov 2019
4 Nov 2019 - 11 Nov 2019
Amount
Taking down chowkats or frames with shutters (without taking off shutters from the frames) area not exc 1.5 Sqm each and removing from site including cutting holes for removal of hold fast complete.
S&F factory made solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube all as specified in Preamble 8B.3.1 of SSR Part -II (2010) and all as shown on drawing of SSR Part-II (2010).
S&F factory made wire gauzed PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and gap insert for top rail and bottom rail; panel will be of wire gauze. The wire gauze shall be wrapped on an additional square 8mm M.S. Solid tube and this tube shall be welded to M.S. tubes. The wire gauge shall be stretched to tighten firmly all as per instruction and drawing shown for item No 8091 of SSR Part II.
S&F factory made solid PVC Moulded door shutter, 28 to 30 mm thick (stiles), with 2, 4 or 6 raised panel design with 2mm thick Moulded PVC sheet on the front face & 2mm plain colour PVC sheet on back face, supplying and fixing in frame at site all as specified in preamble 8B.4.1 and shown on drawing on Sl Page No 161 of SSR Part II (2010) and MES Schedule Part I clause 8.31.4.1.
S & F PTMT butt hinges, size of hinges 100mm.
S & F 150mm long PTMT handles.
S & F 150 mm long PTMT tower bolts.
S&F aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type), and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed, length of bolt 250mm.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) exc 1.5 sqm but not exc 4 Sqm each and removing from site including cutting holes for removal of hold fast complete.
S&F factory made pressed steel frames for door with one or more rebates including necessary fixing lugs, lock strike plate, hinges etc, compete, all as specified of frame size 105 mm x 60mm & thickness of MS sheet shall not be less than 1.25 mm including making holes for fixing hold fast etc and making good the wall with plaster in cement mortar (1:6) complete.
S&F factory made pressed steel frames for door with one or more rebates including necessary fixing lugs, lock strike plate, hinges etc, complete, all as specified of frame size 125 mm x 60mm & thickness of MS sheet shall not be less than 1.25 mm including making holes for fixing hold fast etc and making good the wall with plaster in cement mortar (1:6) complete.
M & L for PCC (1:3:6) type C-0 using 12.5 mm graded stone aggregate in filling in chowkats/ door frame or bed block of hold fast and the like including weathering, slightly rounded or chamfered angles and throating, as directed complete.
Taking down shutters of any description exceeding 1.00 Sqm and not exceeding 2.00 Sqm each and re-fixing the same in same opening.
S&F 35mm thick factory made panelled shutter (two panel) plain framed with lock rail and panel of 12mm thick veneered particle board with commercial veneering on both faces conforming to IS-3097 exterior grade kiln seasoned and chemically pressure treated of second class hard wood rails and styles and the size of rail and style as per IS-1003 (Part I).
S&F mild steel barrel tower bolts, stove enamelled black, with bright bolt, length of bolt 200mm.
S & F butt hinges, medium weight, cold rolled stainless steel and fixed, size of hinges 100mm.
S & F 150 mm mild steel pressed handles, oval type, stove enamelled black.
S & F floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, overall length of cover plate 150mm.
S & F 300 mm long MS ordinary rat tail rod pattern springs for doors including roller and roller plate complete.
S&F stainless steel wire cloth, 0.36 mm nominal dia of wire & average width of aperture 1.40mm and fixed with stainless steel wire staples complete.
S&F in repairs for stainless steel wire cloth, 0.36 mm nominal dia of wire & average width of aperture 1.40mm and fixed with stainless steel staples complete.
S&F factory made steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded including one shop coat painting including dismantling of old existing window as directed.
S&F factory made steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded including one shop coat painting including dismantling of old existing window as directed.
S&F factory made anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified.
S&F factory made anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing not less than 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.) hinge type B-21 100mm long (2 nos.) suitable handle (1 no.) complete all as specified.
S & F MS framed work such as grills, gratings, guard bars etc., with end of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe 290 Gde E-165.
M & L for MS framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc, not exceeding 10 Kg each brackets, conforming to Fe 290 Gde E-165.
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins / spring clips size not exceeding 1.5 Sqm each pane complete.
S & F sheet glass, 4 mm thick ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane fixed with oil putty or wooden beads including Provn of glazing pins/spring clips wherever necessary.
M & L for painting to new steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described with two coats of synthetic enamel paint over a coat of red oxide primer including preparation of surfaces.
M & L for painting to new wood and wood based surfaces of any description, over 10 cm in width or girth, not otherwise described with two coats of synthetic enamel paint over a coat of pink primer including preparation of surfaces.
S&F in repairs 20mm dia harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc as in curtain rails. (Note : The cost of brackets and knobs is deemed to be including in the quoted unit rate. Nothing extra shall be paid on this account.)
Demolition of PCC (unreinforced) of any description and in any position not otherwise specifically provided and removing the debris upto a distance exceeding 1 km but not exceeding 2 km etc complete all as specified.
M&L for PCC (1:5:10) type E2 using 40 mm graded stone aggregate as in filling of sunken floor all as specified.
M&L for sunken treatment to sunken floor, cleaning the surface by using wire brush, rendering to floor and sides with 10 mm thick cement mortar (1:3) including mixing of WPC in mortar @ 3% of cement content, finished even and smooth without using extra cement after that material & labour for providing two coats of two components (one part liquid two parts powder) ready to use cementations water proofing coating on properly prepared surfaces by brushing having elongation of >50% for the applying water proofing treatment as per following on horizontal and vertical surfaces of sunken floor complete all as per manufacturers instruction. (i) Applying 1st coat of two components modified polymer coating. (ii) Provn of glass fiber mess of 2 x 2mm immediately on alone coating. (iii) Apply 2nd coat of two components modified polymer coating after 72 hrs on horizontal and vertical surfaces.
Notes for Srl Item No. 35 : (i) Complete treatment shall be carried out by authorised applicator of waterproofing manufacturer as given in Appx 'B'. (ii) WPC for mixing in cement mortar shall be measured and paid separately.
M & L for 25 mm thick PCC (1:2:4) type B-0 using 12.5mm graded stone aggregate as in floors for bases sunken portion complete.
Supply only liquid water proofing material, ISI marked.
S & F plain mild steel 2.5mm dia wire, galvanised class 3, in fencing including straining and fixing to wood, concrete or steel posts and/or to straining bolts, including securing with and provision of galvanised iron tying wire, galvanised iron staples or steel pins, etc as directed. (Each line of wire to be measured.)
Demolition of brick tiles or terracing tiles, single layer on roofs including removing the demolished material exceeding 1 km and not exceeding 2 km away from site and disposal off in low lying area as directed.
Demolition of mud in roof, any thickness including plastering and leaping (where full thickness recovered or only a part there of) including removing the demolished material not exceeding 200 m away from site and disposal off in low lying area complete.
M&L for 15 mm thick screed bed or bedding layer in cement mortar (1:3) mixed with liquid water proofing material as per manufacturer's instruction as on roof surfaces parapet or vertical beam surface (horizental or vertical) finishing the surfaces even and smooth without using extra cement including racking out joint of brick tiles complete all as specified.(Water proofing material shall be measured and paid for separately). (Note :- Course sand (Toka sand) shall only be used in screed bed/plastering.)
M&L for Lime concrete using 40 mm graded brick aggregate, laid to slope as directed by Engineer in charge over RCC roofs as padding complete alll as specified. Note: Minimum thickness of lime concrete at lower end shall not be less than 50mm.
M&L for 20- 22 mm thick factory made PCC tiles of size 250mm x 250mm with grey cement and no pigment , bedded in cement mortar (1:4) 15 mm thick and joints grouted flush in CM (1:3) mixed with @ 5% of crude oil by weight of cement or mud phuska complete all as specified.
M&L for polythene film in two layers each layer 300 micron thick, laid on a coat of bitumen primer @ 0.30 to 0.50 Kg/Sqm after applying evenly a tack coat of industrial bitumen 85/25 @ 1.20 kg/Sqm complete.
M&L for PCC (1:2:4) type B-0 using 12.5 mm graded stone aggregate mixed with liquid water proofing material as in kerbs, mud stops, along side walls adjoining to roofs and similar items complete. (Water proofing material shall be measured and paid for separately).
S&F in repairs vitreous china wash down water closet pan (EWC) (pedestal pattern), white including white coloured closed pattern seat cover and fixing bolt (excluding flushing cistern and flush pipe)
S&F in repairs vitreous china squatting pan, 'Orissa' pattern, size 580mm x 440mm, white, with integral foot rests including connection to trap, and to flushing pipe, anti-syphonage pipe, etc. including making good to floor and excluding flushing cistern, flush pipe and waste pipe complete.
S & F in repairs PVC valveless, syphonic action type, flushing cistern, 10 litres capacity, low level, white, with inlet, ball valve, float and handle including brackets and PVC flushing pipe 32mm dia complete.
S&F in repairs vitreous china wash basin, white, flat back, size 580mm x 450mm excluding waste, chain and plug and porcelain stopper but including waste coupling and PVC waste pipe of 32 mm dia and fixed on existing brackets complete, .
Supply only 15mm bore chromium plated, fancy type, quarter turn Pillar cock screwed down high pressure, with or without lettered Hot ot Cold with long screwed shanks and flynuts screwed for iron pipe complete all as specified.
S&F in repairs, vitreous china urinal, half stall type, white with grating and union for discharge pipe including waste pipe and providing and fixing plugs bedding urinal against wall in cement mortar (1:2) securing urinal to plugs with and including connections to flushing pipe and outpipes.
S & F in repairs, PVC connections 15 mm bore, 450 mm length, heavy duty, with PTMT nuts.
S & F in repairs, 40mm bore low density polyethylene pipes (LDPE) of pressure rating 6 Kgf / sqcm, fixed complete to walls, ceilings or in floors etc.
S&F in repairs, chromium plated soap tray of size 100 x 100 x 60mm and fixed on wall with chromium plated brass screws complete.
S&F in repairs brass chromium plated shower rose 125 mm size with or without swivel joints fix to steel pipe or union complete all as specified and as directed.
S&F in repairs stop valves, chromium plated, fancy type, quarter turn, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions for 15 mm bore dia of pipe.
S&F stop valves, cast copper alloy, fancy type, quarter turn, chromium plated with long shank and cup (concealed type) screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions for 15 mm bore dia of pipe.
S&F in repairs, 15 mm bore chromium plated, fancy type, quarter turn, bib taps cast copper alloy with crutch or butterfly handle, screwed for iron pipe, or for brass ferrule complete all as specified and as directed.
S&F in repairs, brass chromium plated tubular towel rail, 20 mm dia, D type, 600 mm long between flanges fixed with CP screws and wooden cleats.
M & L for 15 mm bore GI pipe, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors including taking up or down 15 mm bore existing steel tubing and connections complete.
M & L for 20 mm bore GI pipe, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors including taking up or down 20mm bore existing steel tubing and connections complete.
M&L for non skid coloured ceramic tiles of size minimum 400mm x 400mm, 7 to 8 mm thick (square/rectangular), in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile with including 15 mm thick Screed bed or bedding layer in CM (1:6) including dismantling existing floor tiling including cement mortar bedding and removing rubbish to a distance exceeding 1 km but not exceeding 2 km etc complete all as specified. Note: Only course sand shall be used in screed bed.
M&L for non skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 but not exceeding 0.18 sqm, in vertical surface such as skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including M&L for 10 mm thick rendering in CM (1:4) complete and finish the surface rough to receive the tile including dismantling existing hearth or wall tiling including cement mortar bedding (but not backing) etc on brick or stone walls etc including racking out joints hacking for key and scrubbing removing rubbish to a distance exceeding 1 km but not exceeding 2 km etc complete all as specified. all as specified Note: Only course sand shall be used in rendering.
S&F glazed ceramic coloured tiles 450 x 350mm, 7 to 8mm thick in verticle surfaces such as dado / skirting, set and jointed in neat cement slurry and pointed in white or coloured cement pigmented to the match the shade of tiles laid over and including 10 mm thick rendering in cement mortar (1:4) as backing coat and finish the surface rough to receive the tile including dismantling existing hearth or wall tiling including cement mortar bedding (but not backing) etc on brick or stone walls etc including racking out joints hacking for key and scrubbing removing rubbish to a distance exceeding 1 km but not exceeding 2 km etc complete all as specified.
Demolition of PCC (unreinforced) in ground floors and pavings not exc 15cm thickness (below or above ground level) and removing the debris upto a distance exceeding 1 km but not exceeding 2 km etc complete all as specified.
M & L for 50 mm thick PCC (1:3:6) type C2 using 40mm graded stone aggregate as in sub base, floor, path, pavings etc.
M&L for machine cut kota stone slab flooring minimum size 450 mm x 450 mm, 18 to 20 mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing laid over and including 15 mm thick Screed bed or bedding layer in CM (1:6) complete.
All as per item No 69 above but in vertical surfaces such as skirting as directed at site including 10 mm thick rendering as backing coat in cement mortar (1:4) all as directed.
M&L for Makrana doogri Adanga Marble work 18 to 20 mm thick thick, machine cut, bedded, jointed and pointed with grey cement slurry including cutting and polishing complete laid over and including 15 mm thick Screed bed or bedding layer in CM (1:6) and including dismantling of existing floor, hearth or wall tiling including cement mortar bedding (but not backing), terrazo dado/wall tiling and skirting. etc on brick or stone walls etc including racking out joints hacking for key and scrubbing removing rubbish to a distance exceeding 1 km but not exceeding 2 km etc complete all as specified.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc; and cutting chases for concealed water tubing or concealed conduit wiring, etc, and making good, cutting exceeding 10cm but not exceeding 20cm girth in brick walls.
S&F PVC (SWR) 110mm bore pipes, single socketed, in any length with rubber ring joints, fixed to walls with and including MS clamps including taking down existing eaves gutters and rain water pipes (any size or pattern ), including all fittings, heads, shoes, bends, swan necks, etc. (measured overall as fixed along the centre line over fittings and accessories)
S&F 110 mm bore PVC (SWR) bends of any radius / shoe, fixed to PVC pipes as directed.
S & F 100 mm bore cast iron (spun) soil, waste and vent pipes, ISI marked in any length with or without ears, with cement joints, fixed in trenches or in walls/ fixed to walls with and including suitable size clamps including dismantling of existing drain pipes, jointed in cement mortar all as directed.
S&F in repairs 100 mm dia stainless steel floor trap with grating incluing jointing to waste pipe fixed in cement concrete (1:2:4) type B-1, complete all as specified.
S&F 100mm cast iron sanitary connection socket to fit WC out-let.
S & F in repairs 100 mm dia cast iron branch pieces, single (equal or un-equal), ordinary or inverted (spigot or socket type) or with parallel branches with oval access door complete.
S & F in repairs 100 mm bore cast iron bends (any radius), diminishing pieces or tapers (large bore measured) with oval access door.
M&L for rendering 15 mm thick in cement mortar (1:6) on internal wall surfaces of brick work or concrete surfaces and finishing the surface even & smooth without using extra cement including taking down old cement plaster including raking out joints hacking for key scrubbing down with water etc and removing rubbish to a distance exceeding 1 km but not exceeding 2 km etc complete all as specified.
M&L for rendering 15 mm thick in cement mortar (1:4) on external wall surfaces of brick work or concrete surfaces even and fair without using extra cement mixed with liquid water proofing material as per manufacturer's instruction including taking down old cement plaster including raking out joints hacking for key scrubbing down with water etc and removing rubbish to a distance exceeding 1 km but not exceeding 2 km etc complete all as specified. (WPC shall be measured and paid for separately.)
M&L for rendering 5 mm thick in cement mortar in (1:3) finishing the surfaces even and smooth on ceiling including taking down old cement plaster and removing rubbish to a distance exceeding 1 km but not exceeding 2 km etc complete all as specified.
M & L for Brick work using old size bricks, straight or curved on plan exceeding 6 metre mean radius built in cement mortar (1:6), including demolition of old brickwork or stone masonry of any type.
M&L for brick work using sub class ‘B’ old size bricks, straight or curved on plan to any radius in half brick thick walls, built in CM (1:4), including demolition of old brickwork or stone masonry of any type.
M&L for 75 mm thick PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in plinth protection finishing the surface even and smooth without using extra cement.
M & L for providing and injecting chemical emulsion for post constructional anti-termite treatment along external wall where the apron is not provided using chemical emulsion @ 7.5 litres per Sqm of the vertical surface of the sub structure to a depth of 300mm including excavating channel along the wall and rodding etc complete.
M & L for providing and injecting chemical emulsion for post constructional anti-termite treatment along external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc in apron.
M&L for providing and injecting chemical emulsion for post constructional anti-termite treatment of soil under existing floors using emulsion @ 1.00 litre per hole, 300mm apart including drilling and plugging 12mm dia holes with CM (1:2) (1 cement : 2 coarse sand) to match the existing floors.
M&L for providing and injecting chemical emulsion for post constructional anti-termite treatment of voids of masonry using chemical emulsion @ 1.00 litre per hole, 300mm intervals including drilling holes at 45 degree and replugging them with CM (1:2) (1cement : 2 coarse sand) to match the existing floors.
M&L for providing and injecting chemical emulsion for post constructional anti-termite treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same.
S&F 1000 litres capacity Rotational moulded polyethylene in white colour, three layered, water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including dismantling of old water tank of any size and any type and removing rubbish to a distance exceeding 1 km but not exceeding 2 km etc all as directed.
S&F ball valves high pressure of PTMT with epoxy coated Aluminium rod and high density plastic ball screwed for iron pipe of size 20 mm bore (minimum weight 210 gram).
S&F stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions for 20 mm bore dia of pipe.
M & L for preparation of newly plastered surfaces of internal walls and applying the following:- (i) Applying wall care putty in two coats on wall surfaces & smoothening the surface with sand papers/ mechanized sanding etc (preparatory to paint as directed) complete all as specified. (ii) Two coats of 100% acrylic emulsion paint by using airless spray/ roller over and including a coat of acylic internal primer. Note :- Contractor may use manual tools for surface preparation with prior approval of Engg- in- charge in writing in case use of mechanical equipments are not possible.
Complete removal of existing treatment on wall (any number of layears) by scrapping with steel wire brushes or any other means, including filling depressions of scrapped surfaces and M & L for preparation of old plastered surfaces of walls and applying the following:- (i) Applying wall care putty in two coats on wall surfaces & smoothening the surface with sand papers/ mechanized sanding etc (preparatory to paint as directed) complete all as specified. (ii) Two coats of 100% acrylic emulsion paint by using airless spray/ roller over and including a coat of acylic internal primer. Note :- Contractor may use manual tools for surface preparation with prior approval of Engg- in- charge in writing in case use of mechanical equipments are not possible.
M&L for one coat of cement base paint on old prepared surfaces of wall.
M&L for two coats of white wash including preparation of old surfaces of ceiling.
M&L for preparing newly plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer.
M&L for preparation of newly plastered or unplastered surface and applying three coats of white wash on ceilings.
M&L for preparation of old painted wooden surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint on wooden surfaces complete all as specifed.
All as per item No 100 above but on steel surface over 10 cm width or girth and applying two coats of synthetic enamel paint complete.
Internal Electrification
Taking down carefully existing unserviceable copper / aluminum point wiring (light, fan, socket) complete including removal of unserviceable fittings such as switches, switch-sockets, ceiling roses, light fittings etc and removing the retrieved materials from site including making good the disturbed surface of walls, floors, ceilings etc to match with the adjoining work complete all as specified and directed.
M & L for point wiring with multi stranded copper conductor FRLSH cable, 1100 volts grade PVC insulated and unsheathed of size 1.5 Sqmm single core in existing PVC concealed conduit and including new MS sunken box and 3 mm thick bakelite laminated sheet top cover for one fan / light controlled by one switch including provision of 1.5 Sqmm PVC insulated unsheathed with single core, multi stranded copper conductor FRLSH cable as earth wire to common earth & connecting to earth dolly all as specified and directed.
All as per item No 103 here in before but for socket outlet 5 pin, 6 Amp on independent board but not below the switch board complete all as specified .
All as per item No 103 here in before but for one socket outlet 6 pin, 6/16 Amp multipurpose 2 in 1 on independent board with cable of 2.5 Sq mm, multi stranded copper conductor FRLSH cable including provision of 2.5 Sq mm PVC insulated solid copper conductor FRLSH cable continuos as earth wire connected to earth dolly, conductor etc.
M & L for point wiring with multi stranded copper conductor FRLSH cable, 1100 volts grade PVC insulated and unsheathed of size 1.5 Sqmm single core in and including PVC concealed conduit not less than 20mm dia ( medium duty ISI marked) and conduit fittings with and including 3 mm thick bakelite laminated sheet top cover for one fan / light controlled by one switch including provision of 1.5 Sqmm PVC insulated & unsheathed with single core, multi stranded copper conductor FRLSH cable as earth wire to common earth & connecting to earth dolly all as specified and directed.
All as per item No 106 here in before but for socket outlet 5 pin, 6 Amp on same board complete all as specified.
All as per item No 106 here in before but for socket outlet 5 pin, 6 Amp on independent board but not below the switch board complete all as specified .
All as per item No 106 here in before but for one socket outlet 6 pin, 6/16 Amp multipurpose 2 in 1 on independent board with cable of 2.5 Sq mm, multi stranded copper conductor FRLSH cable including provision of 2.5 Sq mm PVC insulated solid copper conductor FRLSH cable continuos as earth wire connected to earth dolly, conductor etc.
All as per item No 106 above but for one light point controlled by two two way switches.
S & F Switch semi modular with frame, flush type, single pole, one way, 5/6 Amp .
S & F Switch semi modular with frame, flush type, single pole, one way, 15/ 16 Amp .
S & F Switch semi modular with frame, flush type, single pole, two way, 5/6 Amp .
S & F Semi modular socket, multipurpose, 2 in 1, 5 Pin, 6 Amp, flush type, including decorative frame cover. (Note: Switch and socket shall be of same make.)
S & F Semi modular socket outlet universal, multipurpose, 2 in 1, 3 Pin 6 Amp and 6 pin 16 Amp, flush type, including decorative frame cover. (Note: Switch and socket shall be of same make.)
S&F, fan regulator electronic step type (1-5), socket type 230-240 Volt, AC supply, complete all as specified and directed.
S&F ceiling rose, 3 plate, surface bakelite type, Polycorbonate body, 6 Amps, 250 Volts AC, 20x50 mm, two to three terminal (ISI marked) complete all as specified.
S & F, In repair, Lamp holder of PVC/Polycarbonate type with back plate suitable for batten fitting including 9 watt LED bulb.
Excavation in trenches not exceeding 1.5 mtr wide, and not exceeding 1.5 metre in depth in soft / loose soil for foundation, laying of cables or pipes (where provided) for protection of cable or fixing poles and stays and struts and including trimming of sides and forming bottom surfaces to required level complete all as directed.
Returning filling in, including spreading , levelling, watering and well ramming in layers each not exceeding 25cm thick in soil complete .
Removal of surplus excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete.
Supply and laying GI tubing, medium grade, 40mm bore complete with all fittings for cable and earth continuity strip protection laid in trenches/fixed to poles/along wall/under road/across the drain complete including taking down old pipe of any size/type. Note: Excavation and earth work shall be measured & paid separately under appropriate item of this BOQ.
Supply and laying Best quality, locally available, sub class 'B' bricks (Old size) for cable protection cover, laid flat and dry in trenches over the cable, perpendicular to the direction of cable complete.
M & L for local sand cushioning, with dry and clean sand, over and under the under ground cables in trenches, ducts for cable protection including consolidation, 80mm thick to the authorized width as per SSR-Part-1 before laying of cable and 150mm thick after laying of cable and punned down to 180mm after laying complete. Note:- Punned thickness shall be considered for payment purpose.
Supply, laying and testing of XLPE insulated, suitable for earthed system, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 3.5 core 35 sq mm complete. (Exacavation & earth work, cable cover & sand cushioning shall be measured and paid for separately under relevent item of this BOQ.)
S & F MCB, SP, 6 to 32 Amps, 'C' curve, 230 Volts, breaking capacity not less than 10 KA with over load and short circuit protection including taking down old unserviceable MCB SP complete all as specified.
S & F MCB, SPN, 40 Amps, 'C' curve , 230 Volts, 50 Hz, breaking capacity not less than 10 KA with over load and short circuit protection and including taking down old unserviceable MCB complete all as specified.
S & F MCB, SPN, 63 Amps, 'C' curve , 230 Volts, 50 Hz, breaking capacity not less than 10 KA with over load and short circuit protection and including taking down old unserviceable MCB complete all as specified.
S & F MCB, TPN, 63 Amps, 'C' curve , 415 Volts, 50 Hz, breaking capacity not less than 10 KA with over load and short circuit protection and including taking down old unserviceable MCB TPN complete all as specified.
S & F sheet metal enclosures double door made out of CRCA mild steel sheet, concealed, surface mounting, acrylic door, IP-43 protection, 4 way, DB SPN 230 Volts, with 200 Amp rated bus bar, dust and vermin proof suitable for fixing MCB's and Isolators etc including taking down old unserviceable DB.
S & F sheet metal enclosures double door made out of CRCA mild steel sheet, concealed, surface mounting, acrylic door, IP-43 protection, 12 way, DB SPN 230 Volts, with 200 Amp rated bus bar, dust and vermin proof suitable for fixing MCB's and Isolators etc including taking down old unserviceable DB.
S & F sheet metal enclosures double door made out of CRCA mild steel sheet, flush mounted, acrylic door, IP-43 protection, 4 way, DB TPN 415 Volts, with 200 Amp rated bus bar, dust and vermin proof suitable for fixing MCB's and Isolators etc including taking down old unserviceable DB.
S & F single pole and neutral enclosure with two pin and earth plug and metal top complete with one single pole MCB 20 Amps including taking down old unserviceable DB.
M&L for sub main wiring with 2 single core cable 6 sqmm, 1100 votls grade PVC insulated unsheathed of copper multi strandard conductor FRLSH cable with continuous copper earth conductor of size 6 sqmm, 1100 votls grade drawing through existing PVC concealed conduit including taking down old unserviceable sub main wiring complete all as specified. Note:- Two runs of cable and one run of earth wire shall be measured as one unit.
M & L for sub main wiring with 2 single core cable PVC insulated unsheathed of copper multi strandard conductor FRLSH cable of size 6 sqmm, 1100 votls grade drawing through in and including PVC concealed conduit 20 mm dia medium duty including acessories such as Tee, bend, Elbow etc, ISI marked with and including PVC insulated 6 sqmm unsheathed multistranded FRLSH copper conductor cable for earth continuity and connected to common earth dolly including cutting chasing of wall, if required and making good disturbed surface in CM (1:3) and finishig the surface to match with existing surface etc including taking down old unserviceable wiring 6 Sqmm complete all as specified. Note:- Two runs of cable, one run of earth wire and one run of PVC conduit shall be measured as one unit.
M & L for sub main wiring with 2 single core cable PVC insulated unsheathed of copper multi strandard conductor FRLSH cable of size 4 sqmm, 1100 votls grade drawing through in and including PVC concealed conduit 20 mm dia medium duty including acessories such as Tee, bend, Elbow etc, ISI marked with and including PVC insulated 4 sqmm unsheathed multistranded FRLSH copper conductor cable for earth continuity and connected to common earth dolly including cutting chasing of wall, if required and making good disturbed surface in CM (1:3) and finishig the surface to match with existing surface etc including taking down old unserviceable wiring 4 Sqmm complete all as specified. Note:- Two runs of cable, one run of earth wire and one run of PVC conduit shall be measured as one unit.
S & F 18/20 watt Retro LED tube light fitting, wall/surface mounted, IP 20 protection, conforming to IS 16106/IS 16107, minimum 6000K batten decorative type 4 feet long polycarbonate body, white, in built LED driver, power factor>0.95 , Make all as per Crompton Cat Part No. DMLN1LT8-16 (for batten) and Cat part No. LT8-20-865-2 (for tube light) including 18/20 watt tube rod or equivalent model of any make given in Appx 'B' connecting to electric point by using PVC insulated twin core copper conductor cable of suitable size including taking down old existing light fitting all as directed
S & F LED mirror light fitting of 07 watt, 6000K, linear & compact with decorative grey end caps, polycarbonate body and ribbed opal diffuser complete including 07 watt tube rod make all as Model No LCL- 7-CDL of Crompton or equivalent model of approved make from list of make attached in tender documents including connecting to electric point by using PVC insulated twin core copper conductor cable of suitable size including taking down old existing light fitting all as directed.
S & F wall mounted/surface mounted decorative wall light fixture in cylinderical profile made up of polycarbonate suitable for and including LED lamp of 7 watt B22 base complete fitting and all other fixing accessories including electric connection with flexible copper wire twin core including taking down old existing light fitting. Make:- Crompton Cat part No. DCWL 15 DF or equivalent model of approved make from list of make attached in tender documents Note:- The rate of LED lamp of 7 watt B22 base is deemed to be included in quoted rate.Nothing extra shall be paid on this account.
S & F energy efficient LED street light fitting of 25 Watt with PDC aluminium body and clear glass with lens for wide beam distribution, top maintainable type with IP 66 degree of protection, PF>0.95 with voltage range 140 to 270 Volt, fitting should be provided with inbuilt 5 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fitting including 25 watt LED lamp with GI brackrt-01 No, MS clamp-02 Nos suitable for walls/ columns and making electrical connection with providing of 1.50 metre long twin core round copper conductor cable of suitable size and testing complete all as per SYSKA cat part No. SSK-SLF-CF-25W-WL or equivalent model of any make given in Appx 'B', Cat Part No. as approved by GE complete all as specified including taking down old unserviceable existing street light fitting of any type and capacity from pole along with accessories.
M & L for 15mm bore GI pipe, light grade, ISI marked, with all fittings and fixed complete to walls and ceilings or laid in trenches or buried in ground for protection earthing lead wire complete all as specified.
M & L for earth continuity conductor or main earthing lead 4mm dia galvanised iron or steel fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for connecting to earthing lead between earthing and MCCB/MCB DB complete including taking down old unserviceable complete all as specified and directed.
M & L in replacement of earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick burried directly in ground to depth of pit not less than 2.25 m below normal ground level with top edge of the plate not less than 1.5 m below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal / coal dust and common salt filling in alternate layers and connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of GI or steel including GI protection pipe 15mm dia light grade upto the extent of 7.5 metre and connecting to earthing test point, main switch board including GI pipe 20 mm dia light grade for watering, MS funnel and bringing out the watering pipe upto 30 cm above the normal ground level plugged at top including all fitting including PCC earth pit with PCC 1:2:4 type B-1 using 20mm graded stone aggregate and RCC pit cover including necessary earthwork and excavation in any type of soil complete all as specified as shown in electrical plate No 3 of SSR Part-I and testing on completion. Note :- (a) PCC chamber shall be constructed at least 1.5 m away from earth pit. Pipe for watering shall be provided in slanting manner. (b) 4mm dia GI wire and 15mm dia light grade GI protection pipe upto 7.5 metre shall deemed to be included in quoted rate.
R K GOYAL & COMPANY
SAPNA BUILDERS
M/s GURFATEH BUILDERS
VISHAV CONSTRUCTIONS
M/s Balvinder Singh Engineer and Contractors
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .