| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.7 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹18.0 L+₹1.2 L (7.33%)Rejected-Finance A 47D RAM DUTT ENCLAVE UTTAM NAGAR NEW DELHI 110059 | WEST | DELHI | 110059 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹18.5 L+₹1.8 L (10.5%)Rejected-Finance RZF 498 MG MARG RAJ NAGAR II PALAM DELHI CANTT 110077 | NEW DELHI | DELHI | 110077 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹21.4 L+₹4.7 L (27.9%)Rejected-Finance B 101 3RD FLOOR JHILMI COLONY DELHI 110095 | DELHI | EAST DELHI | DELHI | 110095 | L4 | Rejected-Finance Other than lowest |
Tender Value
₹23 L
EMD Value
₹46,000
Closing Date
27 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE New Delhi
HQ CWE New Delhi, Rao Tula Ram Marg, Delhi Cantt-10
Provn of B/R work for installation of lift for specially abled children at NCS, Chanakyabagh, New Delhi under GE New Delhi Delhi Cantt
2021_MES_488691_1
CWE-ND/34/2021-22
Open Tender
Miscellaneous Works
Item Rate
120 days
Delhi Cantt
Please refer tender documents
9 documents required · 9 mandatory
₹500
GE New Delhi
₹46,000
Yes
23 Feb 2022
18 Nov 2021
29 Dec 2021
18 Nov 2021
27 Dec 2021
13 Dec 2021
60 days
Amount
M&L for excavating over area, n.exc 1.5 deep and getting out in hard/dense soil complete all as specified and directed.
All as per item no. 1.00 here-in-before but exc. 1.5 m depth and up to 3.0 metre complete all as specified and directed.
M&L for cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M&L for RCC M-25 (Design mix) in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for use & waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, well wall, sides and soffits of foundation and plinth beams and similar work: vertical or to batter complete all as specified and directed.
M&L for Reinforced cement concrete M-25 (design mix) in Columns, vertical band, pillars, piers, posts and struts complete all as specified and directed.
M&L for use & waste formwork to sides and soffits of floor or plinth beams, roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed.
M&L RCC M-25 (design mix) for Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and as directed.
M&L for use & waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) complete all as specified and directed.
S&F mild steel TMT bars of 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia or securing with clips , complete all as specified and directed
All as per item no 10.00 here-in- before but up to and including 10 mm dia in stirrups, spacers and binders as in columns and beams etc. as specified and directed
M&L for Brick work with sub-class `B' bricks, old sized, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for 15 mm thick rendering on other than fair faces of brick work or concrete surfaces in Cement mortar 1:6 finish even and smooth without using extra cement complete all as specified and directed.
M&L for 15 mm thick rendering on fair faces of brick work or concrete surfaces in Cement mortar 1:4 mixed with liquid water proofing compound as per manufacturer's instructions, finish even and smooth without using extra cement complete all as specified and directed. Note:- Liquid water proofing compound shall be measured and paid separately
M&L for 10 mm thick rendering on fair faces of brick work or concrete surfaces in Cement mortar 1:3 finish even and smooth without using extra cement complete all as specified and directed.
M&L for 5 mm thick rendering on fair faces of brick work or concrete surfaces in Cement mortar 1:3 finish even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of newly plastered surfaces and applying two coats of distemper oil emulsion over a coat of primer and wall care putty on walls complete all as specified and directed.
M&L preparation of new plastered surfaces of wall and applying two coats of exterior emulsion paint over a coat of primer including a coat of wall care putty on walls complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm in depth for hard/dense soil complete all as specified and directed.
Removing excavated material out of defence land and depositing where directed.
(a) M&L for cleaning the surface, remove dust dirt, loose particles and unsound substrate and providing 20 mm thick cement screed (1:4) mixed with liquid Water proofing compound 100 gram/Bag over bonding coat of SBR Latex. (b) M&L for APP membrane minimum 3 mm thick plain finish (for accessible roof) polyester reinforced, APP modified bitumen membrane plain finish to the primed substrate with staggered overlap seams of 75 mm (side) and 100 mm (end) a thickness 3 mm (-0.2 / + 0.3) (EN 1849-1) Weight of the membrane not less than 4 kg/Sqm, cold flexibility of - 2 degree Celsius (EN 1109) a tensile strength (long) of 600 N/Sqm (± 20 %) (EN 12311-1) an impact resistance of not less than 600 mm (EN 12001) and water tightness not less than 60 kPa (EN 1928 (B)), laid over Primer @ 0.25 - 0.30 Kg/m 2 The work for water proofing treatment on roofs shall be executed through original manufacturer or their authorised applicator. (c) M&L for Sealing edges well into grooves & protect with CM 1:2 complete all as specified and directed.
M&L for cement concrete 1:2:4 type B-0, (using 12.5 mm graded aggregate) in lintels up to 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed complete all as specified.
M&L for 18 - 20 mm thick (Jet black ) granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) including one number SS clamps (graded - 202) of flat 30 mm x 2 mm 150 mm long made to shape in each slab with drilling hole for hold fastener and 12 mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified.
M&L for 18-20 mm thick (Jet black or equivalent) granite (of any type) machine cut as in flooring, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing laid over 15 mm thick screed bed or bedding layer of cement mortar 1:6 complete all as specified.
Taking down cement plaster on brick walls, raking out joints hacking for key, scrubbing down with water etc. all as specified
Dismantling of floor , hearth or wall tiling including cement mortar bedding (but not backing) and removing rubbish outside MOD land complete all as specified and directed.
M&L for glazed ceramic coloured tiles in vertical surfaces such as skirting and dados of size 300x450x7-8 mm thick, set and jointed in neat cement slurry and pointed with white or coloured cement laid over 10 mm thick rendering of cement mortar 1:4. complete all as specified and directed.
M&L for cement concrete 1:2:4 type B-0, (using 12.5 mm graded aggregate) 25 mm thick as in sub floor/sub base for laying floor finishes/ tiles etc. complete all as specified and directed.
M&L for non skid ceramic tiles 7-8 mm thick coloured(square /rectangular) exc. 0.11 Sqm but not exc. 0.18 Sqm, in floors set and jointed in neat cement slurry and pointed with white or coloured cement laid over 20 mm thick screed bed or bedding layer of cement mortar 1:6 complete all as specified and directed.
M&L for vitrified ceramic dark coloured double charged tiles 10 mm thick (square /rectangular) area of each tiles not exceeding 0.36 Sqm, in floors set and jointed in neat cement slurry and pointed with white or coloured cement laid over 20 mm thick Screed bed or bedding layer of cement mortar 1:6 complete all as specified and directed.
M&L for complete removal of existing treatment from old surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M&L for complete removal of old decorated plastered surfaces of walls and applying one layer of wall care putty as per manufacture's instructions and including application of two coats of plastic emulsion paint over one coat of primer complete all as specified & directed.
M&L for complete removal of existing treatment from old surfaces of wall and applying two coats of Exterior Emulsion paint over one coat of primer over & including one coat of wall care putty all as specified and directed.
M&L for complete removal of existing treatment from old surfaces of wall and applying two coats of oil bound distemper over a coat of primer and over & including one coat of wall care putty complete all as specified and directed.
M&L for sand filling under floors in layers n.exc 25 cm thick and well ramming including watering as required complete all as specified and directed.
M&L for hard core of broken stone or boulders of gauge n.exc 63 mm deposited, spread and level in layers n. exc. 15 cm thick watered and rammed to true surface complete all as specified and directed.
M&L for 100 mm thick Cement Concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in sub-floors, sub- bases, floors & paving etc. complete all as specified and directed.
Demolition of brick work or stone/boulder masonry, built in cement or cement lime mortar including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
Demolition of cement concrete is reinforced (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for all as specified.
Demolition of cement concrete (un reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Dismantling structural steel work including doors, gates but excluding framed trusses complete all as specified and directed.
M&L for MS framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
M&L for Framed work and hung as gates including pintel hinge stops and hand sliding bolt with shouldered and or welded framed work and similar work confirming to Fe-209 Gde A 165 complete all as specified and directed.
S&F plate girder or single stanchions, built up of one beam or mild steel medium channels (ISMC-150) cut to length fixed in beams with binding and welding for hooks complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors/walls, aprons etc. laid bedded and pointed in any mortar complete all as specified and directed.
M&L for 25 mm thick Fibre reinforced heavy duty PU coated cement concrete tile of any pattern decided by GE as in floors/paving laid over 20 mm thick screed bed 1:6, laid and jointed with white cement slurry mixed with pigment to match the shade of tile complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed.
S&F PVC (SWR) pipes single socketed in any length, fixed to walls with clamps 110 mm bore of pipe complete all as specified and directed.
S&F PVC (SWR) bends any radius 110 mm bore equal or unequal with access door complete all as specified and directed.
Supply only water proofing compound liquid complete all as specified and directed.
Excavating in trenches, n.exc 1.5 m wide and n.exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc 10 Sqm on plan and n.exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
M&L for Preparation new steel surface of any description not other wise described over 10 cm width or girth and applying two coat of synthetic enamel paint over one coat of red oxide complete all as specified.
akhil enterprises
MRITUNJYA ASSOCIATES
BEHAL TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .